Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FEDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Additive Manufacturing of Cryogenic Austenitic Steel JK2LB via Wire-Fed Directed Energy Deposition (DED) for Fusion Energy Applications

This study explores the feasibility of fabricating cryogenic austenitic steel JK2LB via both laser-based directed energy deposition (laser-DED) and arc-based directed energy deposition (arc-DED) additive manufacturing processes for potential application in fusion reactors. JK2LB, a low-nickel, high-manganese stainless steel developed for ITER, offers excellent cryogenic toughness, radiation resistance, and decay-to-clearance characteristics. Although JK2LB was originally designed to endure cyclic stresses at cryogenic temperatures in tokamaks, its low-temperature mechanical integrity and radiation tolerance also make it a promising candidate for structural components, such as the coil case/support structure in nonplanar high-temperature superconducting magnet assemblies in stellarators. Directed energy deposition (DED) additive manufacturing was selected for this study due to its capability to fabricate large structures with complex geometries. Here, to address the long lead time and high cost associated with acquiring conventional JK2LB solid wire, JK2LB powder-cored wire was developed as the feedstock material. Testing blocks were then fabricated using both wire-fed laser-DED and arc-DED processes. Microstructural and compositional analyses revealed that both DED approaches yield fully austenitic phase and columnar grain structures. Mechanical testing at room temperature revealed that both DED routes achieved yield strength and elongation comparable to those of conventionally processed JK2LB via vacuum melting, electroslag remelting, extrusion, and drawing, though ultimate tensile strength was reduced due to Mn loss and large columnar grains. As a study mainly focusing on the additive manufacturing process, this work demonstrates the potential of additive manufacturing for fusion energy applications and provides a basis for optimization and future cryogenic mechanical evaluation.

Cryogenic steel↗

Greater vulnerability of snowmelt-fed river thermal regimes to a warming climate

While the advective flux from cool melt runoff can be a significant source of thermal energy to mountainous rivers, it has been a much less addressed process in river temperature modeling and thus our understanding is limited with respect to the spatiotemporal effect of melt on river temperatures at the watershed scale. In particular, the extent and magnitude of the melt cooling effect in the context of a warming climate are not yet well understood. To address this knowledge gap, we improved a coupled hydrology and stream temperature modeling system, Distributed Hydrology Soil Vegetation Model and River Basin Model (DHSVM-RBM), to account for the thermal effect of cool snowmelt runoff on river temperatures. The model was applied to a snow-fed river basin in the Pacific Northwest to evaluate the responses of snow, hydrology, stream temperatures, and potential fish growth to future climates. Historical simulations suggest that snowmelt can notably reduce the basin-wide peak summer temperatures particularly at high-elevation tributaries, while the thermal impacts of melt water can persist through the summer along the mainstem. Ensemble climate projections suggested that a warming climate will decrease basin mean peak snow and summer streamflow by 92% and 60% by the end of the century. Due to the compounded influences of warmer temperatures, lower flows and diminished cooling from melt, rivers reaches in high elevation snow-dominated areas were projected to be most vulnerable to future climate change, showing the largest increases in summer peak temperatures. As a result, thermal habitat used by anadromous Pacific salmon was projected to exhibit substantially lower growth potential during summer in future. These results have demonstrated the necessity of accounting for snowmelt influence on stream temperature modeling in mountainous watersheds.

54 ENVIRONMENTAL SCIENCES↗

BLACK HOLE GROWTH AND ACTIVE GALACTIC NUCLEI OBSCURATION BY INSTABILITY-DRIVEN INFLOWS IN HIGH-REDSHIFT DISK GALAXIES FED BY COLD STREAMS

Disk galaxies at high redshift have been predicted to maintain high gas surface densities due to continuous feeding by intense cold streams leading to violent gravitational instability, transient features, and giant clumps. Gravitational torques between the perturbations drive angular momentum out and mass in, and the inflow provides the energy for keeping strong turbulence. We use analytic estimates of the inflow for a self-regulated unstable disk at a Toomre stability parameter Q {approx} 1, and isolated galaxy simulations capable of resolving the nuclear inflow down to the central parsec. We predict an average inflow rate {approx}10 M{sub Sun} yr{sup -1} through the disk of a 10{sup 11} M{sub Sun} galaxy, with conditions representative of z {approx} 2 stream-fed disks. The inflow rate scales with disk mass and (1 + z){sup 3/2}. It includes clump migration and inflow of the smoother component, valid even if clumps disrupt. This inflow grows the bulge, while only a fraction of {approx}> 10{sup -3} of it needs to accrete onto a central black hole (BH), in order to obey the observed BH-bulge relation. A galaxy of 10{sup 11} M{sub Sun} at z {approx} 2 is expected to host a BH of {approx}10{sup 8} M{sub Sun }, accreting on average with moderate sub-Eddington luminosity L{sub X} {approx} 10{sup 42}-10{sup 43} erg s{sup -1}, accompanied by brighter episodes when dense clumps coalesce. We note that in rare massive galaxies at z {approx} 6, the same process may feed {approx}10{sup 9} M{sub Sun} BH at the Eddington rate. High central gas column densities can severely obscure active galactic nuclei in high-redshift disks, possibly hindering their detection in deep X-ray surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Dynamic Phasor Modeling of Various Multipulse Rectifiers and a VSI Fed by 18-Pulse Asymmetrical Autotransformer Rectifier Unit for Fast Transient Analysis

To study the fast modelling of dynamic characteristics caused by power electronic switching, the dynamic phasor (DP) theory based on the time-varying Fourier decomposition and frequency shifting is firstly applied to the modelling of various multipulse rectifiers. The DP model for symmetrical 12-pulse phase-shifting reactor rectifier unit (PSR-RU) is derived with model order reduction, relations between ac and dc terminals, and Taylor series expansion. The DP model of asymmetrical 18-pulse autotransformer rectifier unit (AT-RU) is proposed based on the switching functions expressed in the DP domain. Meanwhile, the DP model of voltage source inverter (VSI) fed by asymmetrical 18-pulse AT-RU is built with the harmonic state-space (HSS) equations. Under both balanced and unbalanced conditions, the good calculation accuracy and rapid simulation speed of the developed DP models are validated by the detailed time-domain (TD) simulation.

42 ENGINEERING↗

Common-mode noise reduction with impedance balancing in DC-fed motor drives

Unlike conventional passive or active filters, an impedance balancing circuit reduces the common-mode (CM) electromagnetic interference (EMI) noise by establishing an impedance balancing bridge. The EMI noise can be significantly reduced when the impedance bridge is designed to be well balanced. This paper investigates impedance balancing circuits in Dc-fed motor drive systems where both DC input and AC output need to meet EMI standards and thus EMI filters are needed for both sides. An impedance balancing circuit is proposed to reduce both DC and AC side CM noise. Two auxiliary branches are added to the conventional passive filters to establish an impedance bridge and reduce CM noise. The design criteria are presented, and the impact of the proposed impedance balancing circuit on both sides CM noise are investigated. It shows that the proposed impedance balancing circuit can reduce DC side and AC side CM noise based on different mechanisms. The CM noise reduction performance of the proposed method does not depend on the motor and cable models. Experiment results are presented to demonstrate the feasibility and effectiveness of the proposed method.

Chen, Ruirui↗

Investigation of Fourth-leg for Common-mode Noise Reduction in Three-level Neutral Point Clamped Inverter Fed Motor Drive

The four-leg topology has been applied to two-level inverters for common-mode (CM) noise elimination. To achieve zero common-mode voltage (CMV), the zero vector typically used in the two-level inverter is not allowed. As a result, the reference cannot be synthesized by nearest three vectors, which introduces a penalty in dc voltage utilization and current THD. This paper applies the fourth-leg to three-level neutral point clamped (NPC) inverter fed motor drives. Unlike the case in the two-level inverter, the reference can be synthesized by the nearest three vectors while zero CMV can be achieved at the same time in a three-level inverter with the fourth-leg. The topology and modulation are presented. The fourth-leg filter structures are investigated, and a fourth-leg filter structure which decouples the fourth-leg from the main circuit power level is proposed for high power applications. The experiment results on a three-level NPC inverter show that with the fourth-leg and presented modulation applied, the CM noise has been significantly reduced, and around 25 dB attenuation can be observed at the first noise peak in the electromagnetic interference (EMI) frequency range.

Chen, Ruirui↗

The Equilangular Spiral Fed by a Coplanar Microstrip Balun Covering the S, C, X, and K-Bands

There is a requirement to detect signals of interest in a variety of bandwidths over an extremely wide frequency range covering S, C, X, and K bands. In order to accomplish this, an array of antenna elements were designed and fabricated. Due to a span of nearly one decade from the lowest to the highest center frequency, an inherently wide-band cavity backed equiangular spiral antenna design was selected. To allow for miniaturization of the cavity, the spiral was center fed through a coplanar microstrip balun matching network. The antennas radiate right hand circularly polarized (RHCP) far field patterns to counteract cross-polarization effects of the incident electromagnetic field. Furthermore, the RHCP gain was simulated and measured at approximately 8 dBiC with a total 3 dB beam-width in the proximity of 60 degrees for each antenna.

74 ATOMIC AND MOLECULAR PHYSICS↗

Comparison of Doubly-Fed Induction Generator Machine Models for Real-Time Simulations

This work presents a detailed comparison among three implementations of the Doubly-Fed Induction Generator (DFIG) machine model. The alpha-beta-gamma, synchronous (dqo), and natural frame dynamic machine models were deployed on a Field-Programmable Gate Array (FPGA) and compared in terms of execution time and resource utilization. These machine models were also validated against a physical DFIG machine during balanced and unbalanced grid conditions. A benchmark is presented with the objective of selecting the machine model, orientation and state-space representation that is best suited for real-time simulations. The selected machine model is used to develop a real-time emulator of a Type-3 wind system. This emulator enables the study of wind turbine system in realtime using a validated platform while allowing controller testing without relying on expensive third-party solutions.

Ferrari Maglia, Max↗

Frequency Control Support of a Doubly-Fed Induction Generator Based on the Torque Limit

This paper proposes a torque limit-based inertial control scheme of a doubly-fed induction generator (DFIG) that supports the frequency control of a power system. If a frequency deviation occurs, the proposed scheme aims to release a large amount of kinetic energy (KE) stored in the rotating masses of a DFIG to raise the frequency nadir (FN). Upon detecting the event, the scheme instantly increases its output to the torque limit and then reduces the output with the rotor speed so that it converges to the stable operating range. To restore the rotor speed while causing a small second frequency dip (SFD), after the rotor speed converges the power reference is reduced by a small amount and maintained until it meets the reference for maximum power point tracking control. The test results demonstrate that the scheme can improve the FN and maximum rate of change of frequency while causing a small SFD in any wind conditions and in a power system that has a high penetration of wind power, and thus the scheme helps maintain the required level of system reliability. The scheme releases the KE from 2.9 times to 3.7 times the Hydro-Quebec requirement depending on the power reference.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stable Adaptive Inertial Control of a Doubly-Fed Induction Generator

This paper proposes a stable adaptive inertial control scheme of a doubly-fed induction generator. The proposed power reference is defined in two sections: the deceleration period and the acceleration period. The power reference in the deceleration period consists of a constant and the reference for maximum power point tracking (MPPT) operation. The latter contributes to preventing a second frequency dip (SFD) in this period because its reduction rate is large at the early stage of an event but quickly decreases with time. To improve the frequency nadir (FN), the constant value is set to be proportional to the rotor speed prior to an event. The reference ensures that the rotor speed converges to a stable operating region. To accelerate the rotor speed while causing a small SFD, when the rotor speed converges, the power reference is reduced by a small amount and maintained until it meets the MPPT reference. The results show that the scheme causes a small SFD while improving the FN and the rate of change of frequency in any wind conditions, even in a grid that has a high penetration of wind power.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Droop–Based Inertial Control of a Doubly-Fed Induction Generator

If a large disturbance occurs in a power grid, two auxiliary loops for the inertial control of a wind turbine generator have been used: droop loop and rate of change of frequency (ROCOF) loop. Because their gains are fixed, difficulties arise in determining them suitable for all grid and wind conditions. This paper proposes a dynamic droop-based inertial control scheme of a doubly-fed induction generator (DFIG). The scheme aims to improve the frequency nadir (FN) and ensure stable operation of a DFIG. To achieve the first goal, the scheme uses a droop loop, but it dynamically changes its gain based on the ROCOF to release a large amount of kinetic energy during the initial stage of a disturbance. To do this, a shaping function that relates the droop to the ROCOF is used. To achieve the second goal, different shaping functions, which depend on rotor speeds, are used to give a large contribution in high wind conditions and prevent over-deceleration in low wind conditions during inertial control. The performance of the proposed scheme was investigated under various wind conditions using an EMTP-RV simulator. The results indicate that the scheme improves the FN and ensures stable operation of a DFIG.

17 WIND ENERGY↗

A Prediction Method for Catchment Efficiency Loss due to Coaxial Nozzle Wear in Powder Fed Directed Energy Deposition Systems

Abstract Powder fed laser directed energy deposition systems show significant promise and their widespread adoption could greatly advance manufacturing technology; however, a significant amount of gas atomized metal powder is wasted during material deposition. As contaminated powder must be collected and disposed of as hazardous waste, this process is often criticized for its low catchment efficiency. This presents potential implementation and scaling issues, as widespread use of this technology would directly increase the amount of contaminated powder in need of safe disposal. A direct contribution to this waste issue was identified in past work as wearing exterior and interior surfaces on a replaceable nozzle component within the additive head of such a system integrated into a hybrid manufacturing machine tool. A computational fluid dynamics simulation is developed specifically for use within the manufacturing process by predicting catchment efficiency losses before a deposition operation is performed. The model is robust enough to calculate a catchment efficiency estimate within a reasonable transition time before deposition and is designed to replace visual estimation of nozzle deterioration by the machine operator. Both of two previously identified wear modes are represented in the simulation. Their effects on powder stream geometry are discussed in detail and the results are compared with in-situ measurements of powder stream geometry and concentrations. The resulting work contributes to the growing understanding of using prediction and prevention methods on catchment efficiency related part defects within these systems.

DeWitte, Lisa↗

Durable, pure water–fed, anion-exchange membrane electrolyzers through interphase engineering

Anion-exchange membrane water electrolyzers (AEMWEs) promise scalable, low-cost hydrogen production but are limited by the electrochemical instability of their anode ionomers. We report interphase engineering using inorganic-containing molecular additives that coassemble with ionomer, enabling pure water-fed AEMWEs to operate with a degradation rate <0.5 millivolt per hour at 2.0 amperes per square centimeter and 70°C-a >20-fold durability improvement. Analysis of different additives and ionomers shows that the stabilization mechanism involves cross-links between metal oxo/hydroxo oligomers and ionomers. Under operation, the inorganic additive enriches, forming an interphase near the water-oxidation catalyst that passivates the anode ionomer against continuous degradation while maintaining mechanical integrity and hydroxide conductivity. This additive-based interphase-engineering strategy provides a path to durable AEMWEs that operate without supporting electrolytes and is adaptable across diverse catalysts and ionomers for electrochemical technologies.

Hou, Shujin↗

Anodic Conversion of Cyclohexane, Methylcyclohexane, and 2-Propanol: Towards a Regenerable Liquid-Fed Fuel Cell

Liquid Organic Hydrogen Carriers (LOHCs) are promising for hydrogen and energy storage but require endothermic catalytic dehydrogenation. An alternative approach is a regenerable liquid-fed fuel cell which spontaneously converts an organic carrier from its hydrogen-rich to hydrogen-lean form while generating electrical power. The anodic electrooxidation of cyclohexane, methylcyclohexane and 2-propanol in a high temperature polybenzimidazole/phosphoric acid (PBI/PA) PEM fuel cell was investigated along with a quantitative analysis of reaction products. Cyclohexane and methylcyclohexane were predominantly converted to CO 2 with only a trace formation of the corresponding aromatic and cyclic olefin byproducts. This near-to-complete oxidation of the fuels is in sharp contrast to previous reports of a selective conversion of cyclohexane to benzene, with no CO 2 byproducts. In experiments with 2-propanol, acetone was produced, with diisopropylether, propylene and CO 2 as only minor side products. However, the extent of CO 2 formation greatly increased at higher current densities.

25 ENERGY STORAGE↗

Tolerance of engineered Rhodosporidium toruloides to sorghum hydrolysates during batch and fed-batch lipid production

Abstract Background Oleaginous yeasts are a promising candidate for the sustainable conversion of lignocellulosic feedstocks into fuels and chemicals, but their growth on these substrates can be inhibited as a result of upstream pretreatment and enzymatic hydrolysis conditions. Previous studies indicate a high citrate buffer concentration during hydrolysis inhibits downstream cell growth and ethanol fermentation in Saccharomyces cerevisiae . In this study, an engineered Rhodosporidium toruloides strain with enhanced lipid accumulation was grown on sorghum hydrolysate with high and low citrate buffer concentrations. Results Both hydrolysis conditions resulted in similar sugar recovery rates and concentrations. No significant differences in cell growth, sugar utilization rates, or lipid production rates were observed between the two citrate buffer conditions during batch fermentation of R. toruloides . Under fed-batch growth on low-citrate hydrolysate a lipid titer of 16.7 g/L was obtained. Conclusions Citrate buffer was not found to inhibit growth or lipid production in this engineered R. toruloides strain, nor did reducing the citrate buffer concentration negatively affect sugar yields in the hydrolysate. As this process is scaled-up, $131 per ton of hydrothermally pretreated biomass can be saved by use of the lower citrate buffer concentration during enzymatic hydrolysis. Graphical Abstract

09 BIOMASS FUELS↗

Data for Tolerance of Engineered Rhodosporidium toruloides to Sorghum Hydrolysates During Batch and Fed-Batch Lipid Production

Oleaginous yeasts are a promising candidate for the sustainable conversion of lignocellulosic feedstocks into fuels and chemicals, but their growth on these substrates can be inhibited as a result of upstream pretreatment and enzymatic hydrolysis conditions. Previous studies indicate a high citrate buffer concentration during hydrolysis inhibits downstream cell growth and ethanol fermentation in Saccharomyces cerevisiae . In this study, an engineered Rhodosporidium toruloides strain with enhanced lipid accumulation was grown on sorghum hydrolysate with high and low citrate buffer concentrations. Both hydrolysis conditions resulted in similar sugar recovery rates and concentrations. No significant differences in cell growth, sugar utilization rates, or lipid production rates were observed between the two citrate buffer conditions during batch fermentation of R. toruloides . Under fed-batch growth on low-citrate hydrolysate a lipid titer of 16.7 g/L was obtained. Citrate buffer was not found to inhibit growth or lipid production in this engineered R. toruloides strain, nor did reducing the citrate buffer concentration negatively affect sugar yields in the hydrolysate. As this process is scaled-up, $131 per ton of hydrothermally pretreated biomass can be saved by use of the lower citrate buffer concentration during enzymatic hydrolysis.

Conversion↗

Modeling Adjustable Speed Pumped Storage Hydro Units Employing Doubly-Fed Induction Machines

This report is a part of a series of documents to be issued in the course of a U.S. Department of Energy (DOE) project titled “Modeling and Analysis of Value of Advanced Pumped Storage Hydropower in the U.S.” The purpose of this report is to propose a model structure for an adjustable speed pumped storage hydro (PSH) unit employing a doubly-fed induction machine (DFIM). The use of a DFIM with its rotor windings controlled by a power converter is the present state-of-the-art design for adjustable speed hydro pumped storage units. Although the theoretical basis for the analysis of DFIMs was developed at least 70 years ago (a paper by Charles Concordia et al. in 1942 describes the mathematical modeling and dynamic response of DFIM and refers to even earlier publications), it seems appropriate to provide the fundamental equations governing their dynamic behavior so that the following discussions on modeling these devices for stability studies are more meaningful.

Koritarov, Vladimir↗

Nitric-glycolic flowsheet evaluation with the slurry-fed melt rate furnace

The Savannah River National Laboratory (SRNL) was tasked to support validation of the Defense Waste Processing Facility (DWPF) melter offgas flammability model for the nitric-glycolic (NG) flowsheet. The work supports Deliverable 4 of the DWPF & Saltstone Facility Engineering Technical Task Request (TTR)1 and is supplemental to the Cold Cap Evaluation Furnace (CEF) testing conducted in 2014.2 The Slurry-fed Melt Rate Furnace (SMRF) was selected for the supplemental testing as it requires significantly less resources than the CEF and could provide a tool for more rapid analysis of melter feeds in the future. The SMRF platform has been used previously to evaluate melt rate behavior of DWPF glasses, but was modified to accommodate analysis of the offgas stream. Additionally, the Melt Rate Furnace (MRF) and Quartz Melt Rate Furnace (QMRF) were utilized for evaluations. MRF data was used exclusively for melt behavior observations and REDuction/OXidation (REDOX) prediction comparisons and will be briefly discussed in conjunction with its support of the SMRF testing. The QMRF was operated similarly to the SMRF for the same TTR task, but will be discussed in a separate future report. The overall objectives of the SMRF testing were to; 1) Evaluate the efficacy of the SMRF as a platform for steady state melter testing with continuous feeding and offgas analysis; and 2) Generate supplemental melter offgas flammability data to support the melter offgas flammability modelling effort for DWPF implementation of the NG flowsheet.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗