Acridine orange staining reaction as an index of physiological activity in Escherichia coli

The assumption that the acridine orange (AO) color reaction may be used as an index of physiological activity was investigated in laboratory grown Escherichia coli. Spectrofluorometric observations of purified nucleic acids, ribosomes and the microscopic color of bacteriophage-infected cells stained with AO confirmed the theory that single-stranded nucleic acids emit orange to red fluorescence while those that are double-stranded fluoresce green in vivo. Bacteria growing actively in a rich medium could be distinguished from cells in stationary phase by the AO reaction. Cells from log phase appeared red, whereas those in stationary phase were green. However, this differentiation was not seen when the bacteria were grown in a minimal medium or when a variation of the staining method was used. Also, shifting bacteria in stationary phase to starvation conditions rapidly changed their AO staining reaction. Boiling and exposure to lethal concentrations of azide and formalin resulted in stationary-phase cells that appeared red after staining but bacteria killed with chlorine remained green. These findings indicate that the AO staining reaction may be suggestive of physiological activity under defined conditions. However, variables in staining and fixation procedures as well as uncertainties associated with mixed bacterial populations in environmental samples may produce results that are not consistent with the classical interpretation of this reaction. The importance of validating the putative physiological implications of this staining reaction is stressed.

NASA Discipline Number 04-10↗

JSC Advanced Curation: Research and Development for Current Collections and Future Sample Return Mission Demands

Curation of NASA's astromaterials sample collections is a demanding and evolving activity that supports valuable science from NASA missions for generations, long after the samples are returned to Earth. For example, NASA continues to loan hundreds of Apollo program samples to investigators every year and those samples are often analyzed using instruments that did not exist at the time of the Apollo missions themselves. The samples are curated in a manner that minimizes overall contamination, enabling clean, new high-sensitivity measurements and new science results over 40 years after their return to Earth. As our exploration of the Solar System progresses, upcoming and future NASA sample return missions will return new samples with stringent contamination control, sample environmental control, and Planetary Protection requirements. Therefore, an essential element of a healthy astromaterials curation program is a research and development (R&D) effort that characterizes and employs new technologies to maintain current collections and enable new missions - an Advanced Curation effort. JSC's Astromaterials Acquisition & Curation Office is continually performing Advanced Curation research, identifying and defining knowledge gaps about research, development, and validation/verification topics that are critical to support current and future NASA astromaterials sample collections. The following are highlighted knowledge gaps and research opportunities.

Fries, M. D.↗

Background contamination by coplanar polychlorinated biphenyls (PCBs) in trace level high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS) analytical procedures

The addition of the "dioxin-like" polychlorinated biphenyl (PCB) congeners to the assessment of risk associated with the 2,3,7,8-chlorine substituted dioxins and furans has dramatically increased the number of laboratories worldwide that are developing analytical procedures for their detection and quantitation. Most of these procedures are based on established sample preparation and analytical techniques employing high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS), which are used for the analyses of dioxin/furans at low parts-per-trillion (ppt) levels. A significant and widespread problem that arises when using these sample preparation procedures for the analysis of coplanar PCBs is the presence of background levels of these congeners. Industrial processes, urban incineration, leaking electrical transformers, hazardous waste accidents, and improper waste disposal practices have released appreciable quantities of PCBs into the environment. This contamination has resulted in the global distribution of these compounds via the atmosphere and their ubiquitous presence in ambient air. The background presence of these compounds in method blanks must be addressed when determining the exact concentrations of these and other congeners in environmental samples. In this study reliable procedures were developed to accurately define these background levels and assess their variability over the course of the study. The background subtraction procedures developed and employed increase the probability that the values reported accurately represent the concentrations found in the samples and were not biased due to this background contamination.

Polychlorinated Biphenyls/analysis/metabolism↗

Determination of methane in ambient air by multiplex gas chromatography

A multiplex gas chromatographic technique for the determination of methane in ambient air over extended periods is reported. A modest gas chromatograph which uses air as the carrier gas was modified by adding a silver oxide sample modulator for multiplex operation. The modulator selectively catalyzes the decomposition of methane in air. The resulting analytical system requires no consumables beyond power. A profile of the methane concentration in this laboratory was obtained for an 8-day period. During this period, methane concentration varied with an approximately daily period from a low of 1.53 + or - 0.60 ppm to a high of 4.63 + or - 0.59 ppm over the entire 8 days. Some of the measured concentrations are higher than those reported elsewhere indicating the presence of some local source or sources for methane. This work has demonstrated the utility of a relatively simple multiplex gas chromatograph for the analysis of environmental samples. The technique should be applicable to other trace components in air through use of other selective modulators.

Valentin, J. R.↗

Determination of the gram-positive bacterial content of soils and sediments by analysis of teichoic acid components

Many gram-positive bacteria form substituted polymers of glycerol and ribitol phosphate esters known as teichoic acids. Utilizing the relative specificity of cold concentrated hydrofluoric acid in the hydrolysis of polyphosphate esters it proved possible to quantitatively assay the teichoic acid-derived glycerol and ribitol from gram-positive bacteria added to various soils and sediments. The lipids are first removed from the soils or sediments with a one phase chloroform-methanol extraction and the lipid extracted residue is hydrolyzed with cold concentrated hydrofluoric acid. To achieve maximum recovery of the teichoic acid ribitol, a second acid hydrolysis of the aqueous extract is required. The glycerol and ribitol are then acetylated after neutralization and analyzed by capillary gas-liquid chromatography. This technique together with measures of the total phospholipid, the phospholipid fatty acid, the muramic acid and the hydroxy fatty acids of the lipopolysaccharide lipid A of the gram-negative bacteria makes it possible to describe the community structure environmental samples. The proportion of gram-positive bacteria measured as the teichoic acid glycerol and ribitol is higher in soils than in sediments and increases with depth in both.

Ribitol/analogs & derivatives↗

Virus-Like Particle: Evolving Meanings in Different Disciplines

Virus-like particle (VLP) is a term that has been in use for about 80 years. Usually, VLP has meant a particle that is like a virus, generally by appearance, but without either proven or actual virus functionality. Initially VLP referred to particles seen in electron microscope images of tissues. More recently, VLP has come to mean other things to other researchers. A key divergence has been use of VLP in association with vaccine and biotechnology applications versus use of VLP in enumeration of viruses in environmental samples. To these viral ecologists, a VLP is a particle that is virus sized, has nucleic acid, and could be a functional virus. But to vaccine developers and biotechnology researchers a VLP instead is a viral structure that intentionally lacks a viral genome. Here, we look at the history of use of VLP, following changes in meaning as the technology to study VLPs changed.

59 BASIC BIOLOGICAL SCIENCES↗

Psychrotolerant Anaerobes from Lake Podprudnoe, Antarctica and Penguin Spheniscus demersus Colony, South Africa

The study of a sample collected from a wind-made ice sculpture near Lake Podprudnoe, Antarctica led to the isolation of the psychrotolerant strain ISLP-3. Cells of the new isolate are vibrio-shaped that measure 0.5 x 1.0-3.0 micron in size. Growth occurs within the temperature range 5-35 C with the optimum at 22 C. Salinity range for growth is 0-2 % NaCl with the optimum at 0.25 %. The new isolate grows within a pH range from 6.0 to 9.5 with the optimum at 7.5. Strain ISLP-3 is saccharolytic, growing on the following substrates: D-glucose, D-ribose, D-fructose, D-arabinose, maltose, sucrose, D-trehalose, D-mannose, D-cellobiose, lactose, starch, chitin, triethylamine, N-acetylglucosamine, and urea. The best growth occurred on D-cellobiose. An environmental sample of pond water near a colony of the endemic species of African penguins, Spheniscus demersus, was collected in February 2008 and delivered directly to the Astrobiology laboratory at NSSTC. The microbiological study of this sample led to the isolation of two psychrotolerant strains ARHSd-7G and ARHSd-9G. Both strains are strictly anaerobic bacteria and are able to grow at high pH and low temperatures. The cells of strain ARHSd-7G are motile, vibrio-shaped, spore-forming cells. Optimal growth of this strain occurs at 30 C, 3 % NaCl, and pH 8.9. The isolate ARHSd-7G combines sugarlytic and proteolytic metabolisms, growing on some proteolysis products including peptone and yeast extract and a number of sugars. The second isolate, ARHSd-9G, exhibits thin, elongated rods that measure 0.4 x 3-5 micron. The cells are motile and spore-forming. Optimal growth of strain ARHSd-9G occurs at 30 C, 1.75 % NaCl, and pH 8.5. The strain ARHSd-9G is sugarlytic, growing well on substrates such as D-glucose, sucrose, D-cellobiose, maltose, fructose, D-mannose, and trehalose (the only exception is positive growth on yeast extract). In this report, the physiological and morphological characteristics of the novel psychrotolerant, alkaliphilic, and neutrophilic isolates from the Antarctica 2008 expedition will be discussed.

Guisler, Melissa↗

Sensing Techniques for Organochlorides through Intermolecular Interaction with Bicyclic Amidines

Toxic organochloride molecules are widely used in industry for various purposes. With their high volatility, the direct detection of organochlorides in environmental samples is challenging. Here, a new organochloride detection mechanism using 1,5-diazabicyclo[4.3.0]non-5-ene (DBN) is introduced to simplify a sensing method with higher detection sensitivity. Three types of organochloride compounds-trichloroethylene (TCE), dichloromethane (DCM), and dichlorodiphenyltrichloroethane (DDT)—were targeted to understand DCM conjugation chemistry by using nuclear magnetic resonance (NMR) and liquid chromatography with a mass spectrometer (LC-MS). 13C-NMR spectra and LC-MS data indicated that DBN can be labeled on these organochloride compounds by chlorine–nitrogen interaction. Furthermore, to demonstrate the organochloride sensing capability, the labeling yield and limit of detection were determined by a colorimetric assay as well as micellar electrokinetic chromatography (MEKC). The interaction with DBN was most appreciable for TCE, among other organochlorides. TCE was detected at picomolar levels, which is two orders of magnitude lower than the maximum contaminant level set by the United States Environmental Protection Agency. MEKC, in conjunction with this DBN-labeling method, enables us to develop a field-deployable sensing platform for detecting toxic organochlorides with high sensitivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Canary

CANARY is a wearable environmental sampling device that is small, lightweight, and low-power. CANARY integrates a novel mechanism that uses magnets rather than powered pumps to mimic human breathing. In its current form, CANARY breathes, but sensor integration can easily turn this into a standalone device for use in airborne detection of chemicals, biologicals, viruses, etc. CANARY has a small footprint and requires little power to operate enabling it to be used in various environments. Los Alamos researcher have developed a working prototype of the air intake system and are seeking licensees for the current air intake, validation outside the lab, or further development to integrate biosensors as desired.

47 OTHER INSTRUMENTATION↗

Comprehensive analysis of common polymers using hyphenated TGA-FTIR-GC/MS and Raman spectroscopy towards a database for micro- and nanoplastics identification, characterization, and quantitation

Environmental contamination by micro- and nanoplastics (MNPs) is well documented with potential for their increased accumulation globally. Growing public concern over environmental, ecological, and human exposure to MNPs has led to exponential increase in publications, news articles, and reports. Significant knowledge gap exists in standardized analytical methods for the identification and quantification of MNPs from real world environmental samples. Here, in this study, we report comprehensive datasets utilizing thermogravimetric analyzer (TGA) coupled to a Fourier transformed infrared spectrometer (FTIR) and a gas chromatography/mass spectrometer (GC/MS) with corresponding Raman spectral data for the most common polymers documented to be present in the environment (35 plastics of 12 polymer types), to serve as a base line reference for the identification and quantitation of MNPs. Various parameters for TGA-FTIR-GC/MS data acquisition were optimized. Commercial consumer plastic product compositions were identified using this analytical database. Case studies to showcase the utility of the method for polymer mixtures analysis is included. This dataset would serve towards the development of a collaborative, global, comprehensive, and curated public database for the identification of various MNPs and mixtures.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Position-specific carbon isotope analysis of serine by gas chromatography/Orbitrap mass spectrometry, and an application to plant metabolism

Position-specific 13 C/ 12 C ratios within amino acids remain largely unexplored in environmental samples due to methodological limitations. We hypothesized that natural-abundance isotope patterns in serine may serve as a proxy for plant metabolic fluxes including photorespiration. Here we describe an Orbitrap method optimized for the position-specific carbon isotope analysis of serine to test our hypothesis and discuss the generalizability of this method to other amino acids. Position-specific carbon isotope ratios of serine were measured using a Thermo Scientific™ Q Exactive™ GC Orbitrap™. Amino acids were hydrolyzed from Arabidopsis biomass, purified from potential matrix interferences, and derivatized alongside standards. Derivatized serine (N,O-bis(trifluoroacetyl)methyl ester) was isolated using gas chromatography, trapped in a reservoir, and purged into the electron ionization source over tens of minutes, producing fragment ions containing different combinations of atoms from the serine-derivative molecule. The 13 C/ 12 C ratios of fragments with monoisotopic masses of 110.0217, 138.0166, and 165.0037 Da were monitored in the mass analyzer and used to calculate position-specific δ 13 C values relative to a working standard. This methodology constrains position-specific δ 13 C values for nanomole amounts of serine isolated from chemically complex mixtures. The δ 13 C values of fragment ions of serine were characterized with ≤1‰ precisions, leading to propagated standard errors of 0.7–5‰ for each carbon position. Position-specific δ 13 C values differed by up to ca 28 ± 5‰ between serine molecules hydrolyzed from plants grown under contrasting pCO 2 , selected to promote different fluxes through photosynthesis and photorespiration. The method was validated using pure serine standards characterized offline. Here this study presents the first Orbitrap-based measurements of natural-abundance, position-specific carbon isotope variation in an amino acid isolated from a biological matrix. We present a method for the precise characterization of isotope ratios in serine and propose applications probing metabolism in plants. We discuss the potential for extending these approaches to other amino acids, paving the way for novel applications.

59 BASIC BIOLOGICAL SCIENCES↗

Substrate, temperature, and geographical patterns among nearly 2000 natural yeast isolates

Yeasts have broad importance as industrially and clinically relevant microbes and as powerful models for fundamental research, but we are only beginning to understand the roles yeasts play in natural ecosystems. Yeast ecology is often more difficult to study compared to other, more abundant microbes, but growing collections of natural yeast isolates are beginning to shed light on fundamental ecological questions. In this work, we used environmental sampling and isolation to assemble a dataset of 1962 isolates collected from throughout the contiguous United States of America (USA) and Alaska, which were then used to uncover geographic patterns, along with substrate and temperature associations among yeast taxa. We found some taxa, including the common yeasts Torulaspora delbrueckii and Saccharomyces paradoxus, to be repeatedly isolated from multiple sampled regions of the USA, and we classify these as broadly distributed cosmopolitan yeasts. A number of yeast taxon-substrate associations were identified, some of which were novel and some of which support previously reported associations. Further, we found a strong effect of isolation temperature on the phyla of yeasts recovered, as well as for many species. We speculate that substrate and isolation temperature associations reflect the ecological diversity of and niche partitioning by yeast taxa.

59 BASIC BIOLOGICAL SCIENCES↗

High-gradient magnetic filtration of UO 2 colloids from aqueous suspensions

Environmental samples often contain innocuous components that make trace actinide analysis difficult and expensive. Therefore, it is expedient to separate these materials from actinide particles. One characteristic of many actinides is that they are paramagnetic. High-gradient magnetic filtration (HGMF) is a non-destructive technique that selectively captures magnetic constituents from a matrix containing non-magnetic species. Here, in this work, a novel HGMF device made of a permanent magnet array was used to effectively separate UO 2 particles from undesirable soil species. Up to 88% of the UO 2 particles present in suspensions were effectively captured by HGMF, resulting in their enrichment and a substantial reduction in the concentrations of other constituents.

Actinide separations↗

Uncertainty quantification for nuclear forensics with population analyses

Although neural networks offer cutting-edge predictive power, their deployment in high-consequence nuclear forensic applications is limited, partly because of their black-box nature. Incorporating robust uncertainty quantification methods into the predictive frameworks of neural networks is progress towards their future deployment in such scenarios. This work integrates uncertainty quantification into neural networks for nuclear reactor core-average burnup estimation from simulated environmental samples. We test two regimes (homogeneous and heterogeneous events) on DeepSets and Set Transformer architectures, we find both quantify predictive uncertainty effectively, but Set Transformer excels in partitioning latent events, offering superior predictive power and more informative uncertainty estimates.

Hatton, Conner [ORNL] (ORCID:0009000804970959)↗

Evaluation of chromatographic resins for high efficacy separation of radium from chemical analogues

The separation of Radium (Ra) from interfering chemical analogues is of major importance for both the accurate measurement of Ra-226 in environmental samples and the preparation of radium targets destined for medical isotope production. The adsorption behavior of Ra, Barium (Ba), and Strontium (Sr) was investigated on multiple crown-ether-based proprietary extraction chromatographic resins developed by TrisKem Int. Among these, the TK101 resin, characterized by a novel room-temperature ionic liquid (RTIL) dual extractant–solvent system, demonstrated enhanced affinity and selectivity, particularly at low acid concentrations, achieving a D w of 3477 ± 73 for Ra in 0.04 M HNO₃, whereas the maximum Ra D w obtained with the traditional Sr resin in 8 M HNO 3 was only 12.33 ± 0.4. In 0.04 M HNO 3 , a Ra distribution ratio (D w ) of 776 was achieved within 1 min, indicating rapid uptake kinetics. The adsorption capacities were estimated at 19.6 ± 0.1 mg/g for Ba and 12.0 ± 0.2 mg/g for Sr. However, competing alkali metals significantly reduced alkaline earth metal uptake, indicating that the TK101 resin is best suited for radium purification following a preconcentration step to minimize matrix effects in high salinity samples. Dynamic column studies confirmed the strong chromatographic performance of the TK101 resin, with no significant Ba or Sr breakthrough in the Ra fraction and a Ra recovery of 87 ± 2.8%. These results demonstrate the potential of the TK101 resin for selective radium separation in analytical and radiochemical applications.

and nuclear chemistry↗

Visualizing metagenomic and metatranscriptomic data: A comprehensive review

The fields of Metagenomics and Metatranscriptomics involve the examination of complete nucleotide sequences, gene identification, and analysis of potential biological functions within diverse organisms or environmental samples. Despite the vast opportunities for discovery in metagenomics, the sheer volume and complexity of sequence data often present challenges in processing analysis and visualization. This article highlights the critical role of advanced visualization tools in enabling effective exploration, querying, and analysis of these complex datasets. Emphasizing the importance of accessibility, the article categorizes various visualizers based on their intended applications and highlights their utility in empowering bioinformaticians and non-bioinformaticians to interpret and derive insights from meta-omics data effectively.

59 BASIC BIOLOGICAL SCIENCES↗

Review of multi-faceted morphologic signatures of actinide process materials for nuclear forensic science

Particle morphology is an emerging signature that has the potential to identify the processing history of unknown nuclear materials. Using readily available scanning electron microscopes (SEM), the morphology of nearly any solid material can be measured within hours. Coupled with robust image analysis and classification methods, the morphological features can be quantified and support identification of the processing history of unknown nuclear materials. The viability of this signature depends on developing databases of morphological features, coupled with a rapid data analysis and accurate classification process. With developed reference methods, datasets, and throughputs, morphological analysis can be applied within days to (i) interdicted bulk nuclear materials (gram to kilogram quantities), and (ii) trace amounts of nuclear materials detected on swipes or environmental samples. In conclusion, this review aims to develop validated and verified analytical strategies for morphological analysis relevant to nuclear forensics.

36 MATERIALS SCIENCE↗

Conversion of the LLNL/CAMS 1 MV biomedical AMS system to a semi-automated natural abundance 14C spectrometer: system optimization and performance evaluation

The Lawrence Livermore National Laboratory – Center for Accelerator Mass Spectrometry compact 1 MV biomedical accelerator mass spectrometer was repurposed and optimized for the semi-automated radiocarbon measurement of natural abundance environmental samples. Here we present results from 15 months of routine system operation and evaluate the system performance based on 30 sample wheels measured with consistent operating conditions over 7 months from August 2019 to March 2020. Additionally, the average measurement precision was 2.7 ± 0.7‰. System accuracy was assessed with measurements of 14 C-free materials, standard materials with 14 C-content spanning 0.5 to 1.5 F 14 C, and by comparison to split samples measured with the 10 MV AMS system. Overall, this system can routinely measure samples as small as 300 µgC and less than 33000 years without the need for size-specific correction protocols.

43 PARTICLE ACCELERATORS↗