Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Enthalpy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Enthalpy-Based Thermal Evolution of Loops: III. Comparison of Zero-Dimensional Models

Zero dimensional (0D) hydrodynamic models, provide a simple and quick way to study the thermal evolution of coronal loops subjected to time-dependent heating. This paper presents a comparison of a number of 0D models that have been published in the past and is intended to provide a guide for those interested in either using the old models or developing new ones. The principal difference between the models is the way the exchange of mass and energy between corona, transition region and chromosphere is treated, as plasma cycles into and out of a loop during a heating-cooling cycle. It is shown that models based on the principles of mass and energy conservation can give satisfactory results at some, or, in the case of the Enthalpy Based Thermal Evolution of Loops (EBTEL) model, all stages of the loop evolution. Empirical models can lead to low coronal densities, spurious delays between the peak density and temperature, and, for short heating pulses, overly short loop lifetimes.

Cargill, P. J.↗

Surface Catalysis and Oxidation on Stagnation Point Heat Flux Measurements in High Enthalpy Arc Jets

Heat flux sensors are routinely used in arc jet facilities to determine heat transfer rates from plasma plume. The goal of this study is to assess the impact of surface composition changes on these heat flux sensors. Surface compositions can change due to oxidation and material deposition from the arc jet. Systematic surface analyses of the sensors were conducted before and after exposure to plasma. Currently copper is commonly used as surface material. Other surface materials were studied including nickel, constantan gold, platinum and silicon dioxide. The surfaces were exposed to plasma between 0.3 seconds and 3 seconds. Surface changes due to oxidation as well as copper deposition from the arc jets were observed. Results from changes in measured heat flux as a function of surface catalycity is given, along with a first assessment of enthalpy for these measurements. The use of cupric oxide is recommended for future heat flux measurements, due to its consistent surface composition arc jets.

Nawaz, Anuscheh↗

Blunt-Body Aerothermodynamic Database from High-Enthalpy CO2 Testing in an Expansion Tunnel

An extensive database of heating, pressure, and flow field measurements on a 70-deg sphere-cone blunt body geometry in high-enthalpy, CO2 flow has been generated through testing in an expansion tunnel. This database is intended to support development and validation of computational tools and methods to be employed in the design of future Mars missions. The test was conducted in an expansion tunnel in order to avoid uncertainties in the definition of free stream conditions noted in previous studies performed in reflected shock tunnels. Data were obtained across a wide range of test velocity/density conditions that produced various physical phenomena of interest, including laminar and transitional/turbulent boundary layers, non-reacting to completely dissociated post-shock gas composition and shock-layer radiation. Flow field computations were performed at the test conditions and comparisons were made with the experimental data. Based on these comparisons, it is recommended that computational uncertainties on surface heating and pressure, for laminar, reacting-gas environments can be reduced to +/-10% and +/-5%, respectively. However, for flows with turbulence and shock-layer radiation, there were not sufficient validation-quality data obtained in this study to make any conclusions with respect to uncertainties, which highlights the need for further research in these areas.

Hollis, Brian R.↗

A Preliminary Theoretical Study of the Expansion Tube, a New Device for Producing High-Enthalpy Short-Duration Hypersonic Gas Flows

The device considered utilizes an unsteady expansion process for the purpose of total-enthalpy multiplication. Analyses were conducted for both perfect and real air in equilibrium, assuming idealized diaphragm bursts, centered expansion waves, and continuum flow. Results of the study showed the expansion tube capable of outperforming the conventional shock tunnel by a factor of approximately 2 in velocity for the same test-section ambient density and pressure. The degree of dissociation is low at all phases of the thermodynamic cycle in the expansion tube; thus the test-section air has a good possibility of being in equilibrium. Maximum pressures involved in the cycle for duplicating a typical reentry from a lunar mission are low enough for existing pressure-vessel techniques. Both the known and anticipated advantages and disadvantages of this new concept are also discussed.

Trimpi, Robert L.↗

High Enthalpy Testing

A description of High Enthalpy facilities at Ames and through the world, focusing on Arc Jets and Shock Tubes/Tunnels

Ernest Fretter↗

Flows in Enthalpy-based Thermal Evolution of Loops

Plasma-filled loop structures are common in the solar corona. Because detailed modeling of the dynamical evolution of these structures is computationally costly, an efficient method for computing approximate but quick physics-based solutions is to rely on space-integrated 0D simulations. The enthalpy-based thermal evolution of loops (EBTEL) framework is a commonly used method to study the exchange of mass and energy between the corona and transition region. EBTEL solves for density, temperature, and pressure, averaged over the coronal part of the loop, velocity at coronal base, and the instantaneous differential emission measure distribution in the transition region. The current single-fluid version of the code, EBTEL2, assumes that at all stages the flows are subsonic. However, sometimes the solutions show the presence of supersonic flows during the impulsive phase of heat input. It is thus necessary to account for this effect. Here, we upgrade EBTEL2 to EBTEL3 by including the kinetic energy term in the Navier–Stokes equation. We compare the solutions from EBTEL3 with those obtained using EBTEL2, as well as the state-of-the-art field-aligned hydrodynamics code HYDRAD. We find that the match in pressure between EBTEL3 and HYDRAD is better than that between EBTEL2 and HYDRAD. Additionally, the velocities predicted by EBTEL3 are in close agreement with those obtained with HYDRAD when the flows are subsonic. However, EBTEL3 solutions deviate substantially from HYDRAD’s when the latter predicts supersonic flows. Using the mismatches in the solution, we propose a criterion to determine the conditions under which EBTEL can be used to study flows in the system.

Solar coronal heating↗

The Design and Use of Calorimeters For Characterization of High-Enthalpy Flows in Arc-Heated Test Facilities

High-enthalpy, arc-heated flows used for aerothermal testing present a challenging environment for flow characterization. This paper describes the design and use of cooled dwell probes used for heat-transfer and pressure characterization of the NASA and United States Department of Defense (DoD) arc facilities located at Moffett Field, CA, and Arnold Air Force Base, TN. Dwell calorimeters designed, fabricated, and tested by Thermal Technologies, Inc. (TTI) in the NASA IHF and the USAF H1 and H2 arc test facilities provide heat flux and pressure data with excellent repeatability. These calorimeters use standard Gardon calorimeter gages and pressure ports with unique cooling systems enabling them to withstand the severe arc-heated environments for durations sufficient for acquisition of steady-state data. The TTI probes have proven very robust in the extreme aerothermal environments of these facilities. This paper provides an overview of calorimeter instruments typically used in arc facilities, discusses design features of the TTI dwell probes, presents selected data acquired by the TTI calorimeters, and provides comparisons with data acquired from using measurement techniques.

D Mark Smith↗

Active Thermochemical Tables: Enthalpies of Formation of Bromo- and Iodo-Methanes, Ethenes and Ethynes

Here, the thermochemistry of halocarbon species containing iodine and bromine is examined through an extensive interplay between new Feller–Peterson–Dixon (FPD) style composite methods and a detailed analysis of all available experimental and theoretical determinations using the thermochemical network that underlies the Active Thermochemical Tables (ATcT). From the computational viewpoint, a slower convergence of the components of composite thermochemistry methods is observed relative to species that solely contain first row elements, leading to a higher computational expense for achieving comparable levels of accuracy. Potential systematic sources of computational uncertainty are investigated, and, not surprisingly, spin-orbit coupling is found to be a critical component, particularly for iodine containing molecular species. The ATcT analysis of available experimental and theoretical determinations indicates that prior theoretical determinations have significantly larger uncertainties than originally reported, particularly in cases where molecular spin-orbit effects were ignored. Accurate and reliable heats of formation are reported for 38 halogen containing systems, based on combining the current computations with previous experimental and theoretical work via the ATcT approach.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-Enthalpy Testing to Validate Simulation of an Aerosol Capture Probe

AERACEPT (Aerosol Rapid Analysis Combined Entry Probe/sonde Technology) is a developing technology enabling in-situ aerosol particle sampling and analysis in a small spacecraft mission envelope. It integrates a passive aerosol sample collection system into a probe’s thermal protection system (TPS) to remove the need for heat shield separation and active descent control (parachutes, gliders, etc.). AERACEPT is being validated against the requirements of the Nephele mission concept, which targets the middle and lower Venus cloud layers. The proposed technology employs 3D Carbon-Carbon (3D-CC) at the probe’s nose to withstand the extreme environments encountered in a Venus entry without producing pyrolysis gases that would contaminate the mission sample collection. Any shape change of this 3D-CC sample inlet will affect airflow through the sampling system, thereby impacting aerosol sample collection bias and efficiency. Accurate prediction of the nose’s material response during entry is there-fore of fundamental importance to the development and practical use of this technology. As a result, the AERACEPT project is planning a test campaign in the newly built PlasmatronX facility with a novel “Open Iso-Q” test article to validate state-of-the-art material response tools for a simulated Venus entry. The PlasmatronX is a 350 kW inductively-coupled plasma facility developed and run by the Center for Hypersonics and Entry Systems Studies at the University of Illinois at Urbana-Champaign. The facility can support ground testing for a variety of planetary destinations by simulating entry conditions in Nitrogen, Air, and Carbon Dioxide. To best simulate the Venus atmosphere and match flight-like recession, the planned AERACEPT test campaign will use Carbon Dioxide as its test gas. AERACEPT has designed two test articles for this campaign: 1) a standard test article whose curved surface approximates a constant applied heat flux (“Closed Iso-Q” model) and 2) a novel inlet test article with a through-hole at the stagnation point (“Open Iso-Q” model). Both article types consist of a 3D-CC sample bonded to a graphite fixture. All articles will be laser scanned before and after testing to estimate shape change and recession, and the “Closed Iso-Q” articles will be instrumented with thermocouples to provide temperature histories. The test article temperatures and inlet shape change will be compared against simulations run with the Porous material Analysis Toolbox based on OpenFOAM (PATO) to validate the AERACEPT 3D-CC material response model. Due to the high thermal conductivity of 3D-CC, multidimensional effects have a large influence on the test article temperature and the standard 1-D material response tools are not sufficient for test planning. The test campaign features (e.g. article design, run duration, heat fluxes) are therefore informed by a series of 3-D simulations using state-of-the-art material response tools such as PATO. The test campaign is scheduled for spring of 2024. Expected results include 1) Key drivers of selected test conditions (e.g. matching mission flight atmosphere & recession), 2) Simulation results that informed test article design, 3) Acquired test data such as recession measurements, temperature histories, and photos, and 4) Comparisons between test results and simulation predictions.

AERACEPT↗

High-Enthalpy Testing to Validate Simulation of an Aerosol Capture Probe

AERACEPT (Aerosol Rapid Analysis Combined Entry Probe/sonde Technology) is a developing technology enabling in-situ aerosol particle sampling and analysis in a small spacecraft mission envelope. It integrates a passive aerosol sample collection system into a probe’s thermal protection system (TPS) to remove the need for heat shield separation and active descent control (parachutes, gliders, etc.). AERACEPT is being validated against the requirements of the Nephele mission concept, which targets the middle and lower Venus cloud layers. The proposed technology employs 3D Carbon-Carbon (3D-CC) at the probe’s nose to withstand the extreme environments encountered in a Venus entry without producing pyrolysis gases that would contaminate the mission sample collection. Any shape change of this 3D-CC sample inlet will affect airflow through the sampling system, thereby impacting aerosol sample collection bias and efficiency. Accurate prediction of the nose’s material response during entry is there-fore of fundamental importance to the development and practical use of this technology. As a result, the AERACEPT project is planning a test campaign in the newly built PlasmatronX facility with a novel “Open Iso-Q” test article to validate state-of-the-art material response tools for a simulated Venus entry. The PlasmatronX is a 350 kW inductively-coupled plasma facility developed and run by the Center for Hypersonics and Entry Systems Studies at the University of Illinois at Urbana-Champaign. The facility can support ground testing for a variety of planetary destinations by simulating entry conditions in Nitrogen, Air, and Carbon Dioxide. To best simulate the Venus atmosphere and match flight-like recession, the planned AERACEPT test campaign will use Carbon Dioxide as its test gas. AERACEPT has designed two test articles for this campaign: 1) a standard test article whose curved surface approximates a constant applied heat flux (“Closed Iso-Q” model) and 2) a novel inlet test article with a through-hole at the stagnation point (“Open Iso-Q” model). Both article types consist of a 3D-CC sample bonded to a graphite fixture. All articles will be laser scanned before and after testing to estimate shape change and recession, and the “Closed Iso-Q” articles will be instrumented with thermocouples to provide temperature histories. The test article temperatures and inlet shape change will be compared against simulations run with the Porous material Analysis Toolbox based on OpenFOAM (PATO) to validate the AERACEPT 3D-CC material response model. Due to the high thermal conductivity of 3D-CC, multidimensional effects have a large influence on the test article temperature and the standard 1-D material response tools are not sufficient for test planning. The test campaign features (e.g. article design, run duration, heat fluxes) are therefore informed by a series of 3-D simulations using state-of-the-art material response tools such as PATO. The test campaign is scheduled for spring of 2024. Expected results include 1) Key drivers of selected test conditions (e.g. matching mission flight atmosphere & recession), 2) Simulation results that informed test article design, 3) Acquired test data such as recession measurements, temperature histories, and photos, and 4) Comparisons between test results and simulation predictions.

AERACEPT↗

Extracting meaningful standard enthalpies and entropies of activation for surface reactions from kinetic rates

While analyses based on the Arrhenius kinetic model have been successfully applied since its introduction, the Arrhenius model neglects to describe pre-exponential factor in a scientifically meaningful fashion. Since the 1930s, transition-state theory (TST), has met with success in interpreting the pre-exponential factor’s value, allowing a standard entropy of activation to be estimated. However, analyses based on TST’s assumptions have been applied inconsistently in the literature, particularly in corrosion science, leading to difficulty in comparison of standard entropy of activations from different studies. In this work, the foundational principles of TST and standard states are discussed and a standard method to apply TST in analyzing rates of surface reactions is recommended. When full details are not available, reacting species’ concentrations should be normalized to the concentration of active surface sites. For corrosion reactions, conversion relationships are given to convert from units of corrosion rate to surface reaction rate, consistent with TST. This method is dubbed a surface reactant equi-density approximation. Application of this standard to reported data results in adjustments of the standard entropy of activation between - 65 and +50 J/mol K and brings reported entropies into a narrower range of values.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗