Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “End Use Load Profile”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Variations in lithospheric thickness on Venus

Recent analyses of Magellan data have indicated many regions exhibiting topograhic flexure. On Venus, flexure is associated predominantly with coronae and the chasmata with Aphrodite Terra. Modeling of these flexural signatures allows the elastic and mechanical thickness of the lithosphere to be estimated. In areas where the lithosphere is flexed beyond its elastic limit the saturation moment provides information on the strength of the lithosphere. Modeling of 12 flexural features on Venus has indicated lithospheric thicknesses comparable with terrestrial values. This has important implications for the venusian heat budget. Flexure of a thin elastic plate due simultaneously to a line load on a continuous plate and a bending moment applied to the end of a broken plate is considered. The mean radius and regional topographic gradient are also included in the model. Features with a large radius of curvature were selected so that a two-dimensional approximation could be used. Comparisons with an axisymmetric model were made for some features to check the validity of the two-dimensional assumption. The best-fit elastic thickness was found for each profile crossing a given flexural feature. In addition, the surface stress and bending moment at the first zero crossing of each profile were also calculated. Flexural amplitudes and elastic thicknesses obtained for 12 features vary significantly. Three examples of the model fitting procedures are discussed.

Johnson, C. L.↗

Demand Response Availability Profiles for California in the Year 2020

Demand response (DR) is being considered as a valuable resource for keeping the electrical grid stable and efficient, and deferring upgrades to generation, transmission, and distribution systems. However, simulations to determine how much infrastructure upgrades can be deferred are necessary in order to plan optimally. Production cost modeling is a technique, which simulates the dispatch of generators to meet demand and reserves in each hour of the year, at minimal cost. By integrating demand response resources into a production cost model (PCM), their value to the grid can be estimated and used to inform operations and infrastructure planning. DR availability profiles and constraints for 13 end-uses in California for the year 2020 were developed by Lawrence Berkeley National Laboratory (LBNL), and integrated into a production cost model by Lawrence Livermore National Laboratory (LLNL), for the California Energy Commission’s Value of Energy Storage and Demand Response for Renewable Integration in California Study. This report summarizes the process for developing the DR availability profiles for California, and their aggregate capabilities. While LBNL provided potential DR hourly profiles for regulation product in the ancillary services market and five-minute load following product in the energy market for LLNL’s study, additional results in contingency reserves and an assumed flexible product are also defined. These additional products are included in the analysis for managing high ramps associated with renewable generation and capacity products and they are also presented in this report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of low heat conductivity rf cables

New potential applications of superconducting radio-frequency can be envisioned with conduction cooling of the cavities using cryocoolers. In this case, the total heat load to the cryocoolers have to be carefully managed to assure sufficient margin to operate the cavity at an acceptable accelerating gradient. The static and dynamic heat load from rf cables connected to the cavity can be a significant contribution to the total heat load. In this contribution we report the results from measurements of the temperature profile at 1.3 GHz for two low heat conductivity rf cables, as a function of the rf power and with one end of the cable in thermal contact with a liquid helium bath at 4.3 K. A parametric model of the two cables was developed with ANSYS to match the temperature profiles and calculate the heat load at the cold end of the cable.

Cheng, G.↗

Mount Protects Thin-Walled Glass or Ceramic Tubes from Large Thermal and Vibration Loads

The design allows for the low-stress mounting of fragile objects, like thin walled glass, by using particular ways of compensating, isolating, or releasing the coefficient of thermal expansion (CTE) differences between the mounted object and the mount itself. This mount profile is lower than true full kinematic mounting. Also, this approach enables accurate positioning of the component for electrical and optical interfaces. It avoids the higher and unpredictable stress issues that often result from potting the object. The mount has been built and tested to space-flight specifications, and has been used for fiber-optic, optical, and electrical interfaces for a spaceflight mission. This mount design is often metal and is slightly larger than the object to be mounted. The objects are optical or optical/electrical, and optical and/or electrical interfaces are required from the top and bottom. This requires the mount to be open at both ends, and for the object s position to be controlled. Thin inside inserts at the top and bottom contact the housing at defined lips, or edges, and hold the fragile object in the mount. The inserts can be customized to mimic the outer surface of the object, which further reduces stress. The inserts have the opposite CTE of the housing material, partially compensating for the CTE difference that causes thermal stress. A spring washer is inserted at one end to compensate for more CTE difference and to hold the object against the location edge of the mount for any optical position requirements. The spring also ensures that any fiber-optic or optic interface, which often requires some pressure to ensure a good interface, does not overstress the fragile object. The insert thickness, material, and spring washer size can be traded against each other to optimize the mount and stresses for various thermal and vibration load ranges and other mounting requirements. The alternate design uses two separate, unique features to reduce stress and hold the object. A release agent is applied to the inside surface of the mount just before the binding potting material is injected in the mount. This prevents the potting material from bonding to the mount, and thus prevents stress from being applied, at very low temperatures, to the fragile object being mounted. The potting material mixing and curing is temperature- and humidity-controlled. The mount has radial grooves cut in it that the potting material fills, thus controlling the vertical position of the mounted object. The design can easily be used for long and thin objects, short and wide objects, and any shape in between. The design s advantages are amplified for long and thin fragile objects. The general testing range was 45 to +45 C, but multiple mounts were successfully tested down to 60 and up to 50 C and the design can be adjusted for larger ranges.

Amato, Michael↗

Solar plus: Optimization of distributed solar PV through battery storage and dispatchable load in residential buildings

As utility electricity rates evolve, pairing solar photovoltaic (PV) systems with battery storage has potential to ensure the value proposition of residential solar by mitigating economic uncertainty. In addition to batteries, load control technologies can reshape customer load profiles to optimize PV system use. The combination of PV, energy storage, and load control provides an integrated approach to PV deployment, which we call 'solar plus'. The U.S. National Renewable Energy Laboratory's Renewable Energy Optimization (REopt) model is utilized to evaluate cost-optimal technology selection, sizing, and dispatch in residential buildings under a variety of rate structures and locations. The REopt model is extended to include a controllable or 'smart' domestic hot water heater model and smart air conditioner model. We find that the solar plus approach improves end user economics across a variety of rate structures - especially those that are challenging for PV - including lower grid export rates, non-coincident time-of-use structures, and demand charges.

14 SOLAR ENERGY↗

Development and Implementation of a Hardware In-the-Loop Test Bed for Unmanned Aerial Vehicle Control Algorithms

Successful prediction and management of battery life using prognostic algorithms through ground and flight tests is important for performance evaluation of electrical systems. This paper details the design of test beds suitable for replicating loading profiles that would be encountered in deployed electrical systems. The test bed data will be used to develop and validate prognostic algorithms for predicting battery discharge time and battery failure time. Online battery prognostic algorithms will enable health management strategies. The platform used for algorithm demonstration is the EDGE 540T electric unmanned aerial vehicle (UAV). The fully designed test beds developed and detailed in this paper can be used to conduct battery life tests by controlling current and recording voltage and temperature to develop a model that makes a prediction of end-of-charge and end-of-life of the system based on rapid state of health (SOH) assessment.

Battery Testbed↗

Preparation for and Performance of a Pseudomonas aeruginosa Biofilm Experiment On Board the International Space Station

Biofilms are a problem on Earth given their ability to degrade the materials upon which they grow and due to their relevance to infections. Remarkably, 65% and 80% of infections and chronic diseases on Earth are associated with biofilms, respectively. In space, these problems' impact is higher because the crew's lives and mission success depend on nominal operation of mechanical systems. Furthermore, the isolated confined environment nature of spaceflight may increase the rates of disease transmission. In the case of the International Space Station (ISS), biofilms are an identified problem on the Environmental Control and Life Support System (ECLSS), namely on the water processor assembly (WPA). In late 2019, the Space Biofilms experiment launched towards ISS to (i) characterize the mass, thickness, morphology, and gene expression of biofilms formed in space with respect to matched Earth controls, (ii) interrogate the expression of antimicrobial resistance genes, and (iii) test novel materials as potential biofilm control strategies for future ECLSS components. For this, 288 bacterial samples were prepared prior to the launch of the Northrop Grumman CRS-12 mission from NASA's Wallops Flight Facility. The samples were integrated into the spaceflight hardware, BioServe's Fluid Processing Apparatus (FPA) packed in sets of eight in Group Activation Packs (GAP). Half of these samples were activated and terminated on orbit by NASA astronauts Jessica Meir and Christina Koch, while the remaining half were processed equivalently on Earth. The spaceflight bacterial samples of Space Biofilms returned on board SpaceX' CRS-19 Dragon spacecraft, in early 2020. We here describe the test campaign implemented to verify the experiment design and confirm it would enable us to achieve the project's scientific goals. This campaign ended with the Experiment Verification Test (EVT), from which we here present example morphology and transcriptomic results. We describe in detail the sample preparation prior to flight, including cleaning and sterilization of the coupons of six materials (SS316, passivated-SS316, lubricant impregnated surface, catheter-grade silicone with and without a nanotopography, and cellulose membrane), loading and integration of growth media, bacterial inoculum, fixative and preservative to enable experiment termination on orbit. Additionally, we describe the performance of the experiment on board the ISS, including crew activities, use of assets, temperature profile, and experiment timeline; all leading to a successful spaceflight experiment.

Pamela Flores↗

Simulation of a Single Rotor and a Quadrotor Hovering in Full and Partial Ground Effect

With the development of urban air mobility, the safety of multirotor vehicle operations in proximity to vertiports must be assessed. This paper examines high-fidelity blade-resolved OVERFLOW simulations and medium-fidelity vortex particle–mesh simulations that capture the aerodynamics of a rotorcraft in full and partial ground effect. Results obtained with each CFD method are compared to verify the consistency of the models introduced in the latter, which include an immersed lifting line for the blade aerodynamics and various boundary conditions to account for solid surfaces such as ground and walls. Satisfactory agreement is obtained for the blade loads and rotorwash velocity profiles in the case of a single rotor, except for small discrepancies at the blade tip. Finally, a quadrotor air taxi is simulated to quantify the load imbalance when the vehicle hovers above a rooftop edge. The combined use of high- and medium-fidelity methods is envisioned to accelerate the workflow when a large number of configurations need to be tested.

HEC↗

A Dynamic Pricing Method to Manage the Impact of EV Charging on the Grid Using RL

This work addresses the challenge of managing electrical vehicle (EV) charging loads on distribution feeders with the increase in deployment of fast charging stations. To mitigate the adverse impacts on feeder health, a novel dynamic grid-informed pricing approach is proposed. This approach leverages reinforcement learning (RL) to determine hourly charging prices based on real-time grid conditions. A synthetic environment was developed to train the reinforcement learning agent. A model of an IEEE 34-bus distribution feeder with EV charging stations has been developed in OpenDSS utilizing Caldera for realistic EV charging profiles. Test cases demonstrate that the dynamic pricing strategy achieves higher energy delivery to the EV end user at a lower cost compared to constant pricing methods, while lowering voltage deviations and congestion. This approach offers more granular price adjustments, responding dynamically to feeder conditions and potentially improving grid stability and efficiency. The communication architecture to implement this dynamic pricing method is described. This research contributes to the development of smart grid-informed charging solutions that can reduce the cost of charging to the end user while also helping the grid.

EV charging, dynamic pricing, grid-informed chargi↗

A dynamic pricing method to manage the impact of EV charging on the grid using RL

This work addresses the challenge of managing electrical vehicle (EV) charging loads on distribution feeders with the increase in deployment of fast charging stations. To mitigate the adverse impacts on feeder health, a novel dynamic grid-informed pricing approach is proposed. This approach leverages reinforcement learning (RL) to determine hourly charging prices based on real-time grid conditions. A synthetic environment was developed to train the reinforcement learning agent. A model of an IEEE 34-bus distribution feeder with EV charging stations has been developed in OpenDSS utilizing Caldera for realistic EV charging profiles. Test cases demonstrate that the dynamic pricing strategy achieves higher energy delivery to the EV end user at a lower cost compared to constant pricing methods, while lowering voltage deviations and congestion. This approach offers more granular price adjustments, responding dynamically to feeder conditions and potentially improving grid stability and efficiency. The communication architecture to implement this dynamic pricing method is described. This research contributes to the development of smart grid-informed charging solutions that can reduce the cost of charging to the end user while also helping the grid.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

OCHRE: The Object-oriented, Controllable, High-resolution Residential Energy Model for Dynamic Integration Studies

Electrification and the growth of distributed energy resources (DERs), including flexible loads, are changing the energy landscape of electric distribution systems and creating new challenges and opportunities for electric utilities. Changes in demand profiles require improvements in distribution system load models, which have not historically accounted for device controllability or impacts on customer comfort. Although building modeling research has focused on these features, there is a need to incorporate them into distribution load models that include DERs and can be used to study grid-interactive buildings. In this paper, we present the Object-oriented, Controllable, High-resolution Residential Energy (OCHRE) model. OCHRE is a controllable thermal-electric residential energy model that captures building thermal dynamics, integrates grid-dependent electrical behavior, contains models for common DERs and end-use loads, and simulates at a time resolution down to 1 minute. It includes models for space heaters, air conditioners, water heaters, electric vehicles, photovoltaics, and batteries that are externally controllable and integrated in a co-simulation framework. Using a proposed zero energy ready community in Colorado, we co-simulate a distribution grid and 498 all-electric homes with a diverse set of efficiency levels and equipment properties. We show that controllable devices can reduce peak demand within a neighborhood by up to 73% during a critical peak period without sacrificing occupant comfort. We also demonstrate the importance of modeling load diversity at a high time resolution when quantifying power and voltage fluctuations across a distribution system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Large-scale simulation-based parametric analysis of an optimal precooling strategy for demand flexibility in a commercial office building

Achieving success with grid-interactive efficient buildings (GEBs) is closely tied to the utilization of flexible loads. A valuable strategy involves the implementation of precooling techniques before high-demand events, such as peak hours, by adjusting zone air temperature setpoints. This leads to a reduction in thermal loads and peak electricity demand during these times, as the building’s thermal mass stores and subsequently releases thermal energy. However, the effectiveness of the pre-cooling optimization is highly contingent on specific conditions such as building thermal properties, weather conditions, utility rate structure, HVAC equipment sizing, etc. Therefore, investigating the impacts of these condition-specific factors is crucial, especially when considering precooling strategies that utilize thermal mass in commercial buildings. In this paper, we first devised a novel heuristic control approach that incorporates parameterized optimal precooling thermostat schedules to enhance demand flexibility in a commercial office building. Subsequently, we conducted a thorough performance evaluation of this control strategy. Here, the optimal thermostat schedule was parameterized using three optimization variables: the precooling start time, the precooling end time, and the precooling temperature setpoint. Utilizing the DOE medium-sized office building as the virtual testbed, we showed that the parameterized schedule effectively approximates model predictive control and requires drastically reduced computational overhead. In addition, we investigated the impact of different influencing factors on the optimal precooling strategy. These factors include building thermal mass, outdoor air conditions, and energy price profiles. Using high-performance computing, we simulated a total of 225 scenarios, consisting of three levels of thermal mass, five typical outdoor air temperature profiles, and fifteen time-of-use price plans. The results demonstrate that optimal thermostat scheduling could save substantial energy cost in medium-sized office buildings with heavy thermal mass but with some energy penalty. Although the potential for cost savings is lower in buildings with low and medium thermal mass, the energy penalty remains consistent in all three thermal mass scenarios. The study also highlights the need to account for zone diversity and recognize that a one-size-fits-all-zone setpoint schedule may not be suitable for all zones and can lead to unnecessary energy wastage. Furthermore, the results highlight that while outdoor air conditions play a role in cost and energy performance, the cooling load exerts a more immediate and substantial influence on cost savings in precooling strategies. Although cost savings are comparable under certain conditions with the same cooling load, observed deviations in energy penalty indicate potential disparities in the efficiency of the HVAC system during the load-shifting process. In addition, the duration of peak pricing and the ratio between peak and off-peak times exhibit clear correlations with cost savings and energy consumption, aligning with intuitive expectations. These findings offer valuable insights for optimizing precooling strategies in office buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Do ambient shear and thermal stratification impact wind turbine tip-vortex breakdown?

Modern wind turbines experience uneven inflow conditions across the rotor, due to the ambient flow’s shear and thermal stratification. Such conditions alter the shape and length of turbine wakes and thus impact the loads and power generation of downstream turbines. To this end, understanding the spatial evolution of the individual wakes under different atmospheric conditions is key to controlling and optimising turbine arrays. With this numerical study we aim to obtain a better understanding of the fundamental physics governing the near-wake dynamics of wind turbines under shear and thermal stability, by examining their tip-vortex breakup mechanisms. Our approach considers scale-resolving simulations of a single turbine wake under a linear shear profile as well as the application of harmonic tip perturbations to trigger flow instabilities. For the subsequent analysis we use the proper orthogonal decomposition (POD) method to extract coherent structures from the flow, and we also calculate mean kinetic energy fluxes to quantify each coherent structure’s contribution to wake recovery. The wake’s helical spiral is found to hinder wake recovery for all studied ambient flow conditions, whereas the mutual inductance instability has positive MKE flux leading to an enhanced wake recovery. Finally, the ambient shear has the largest impact on the local MKE flux with respect to downstream location by changing the shape of the curve and location of extrema, whereas thermal stratification has only a minimal impact on the magnitude of the near-wake local MKE flux distribution.

17 WIND ENERGY↗

SU-F-P-39: End-To-End Validation of a 6 MV High Dose Rate Photon Beam, Configured for Eclipse AAA Algorithm Using Golden Beam Data, for SBRT Treatments Using RapidArc

Purpose: To use end-to-end testing to validate a 6 MV high dose rate photon beam, configured for Eclipse AAA algorithm using Golden Beam Data (GBD), for SBRT treatments using RapidArc. Methods: Beam data was configured for Varian Eclipse AAA algorithm using the GBD provided by the vendor. Transverse and diagonals dose profiles, PDDs and output factors down to a field size of 2×2 cm2 were measured on a Varian Trilogy Linac and compared with GBD library using 2% 2mm 1D gamma analysis. The MLC transmission factor and dosimetric leaf gap were determined to characterize the MLC in Eclipse. Mechanical and dosimetric tests were performed combining different gantry rotation speeds, dose rates and leaf speeds to evaluate the delivery system performance according to VMAT accuracy requirements. An end-to-end test was implemented planning several SBRT RapidArc treatments on a CIRS 002LFC IMRT Thorax Phantom. The CT scanner calibration curve was acquired and loaded in Eclipse. PTW 31013 ionization chamber was used with Keithley 35617EBS electrometer for absolute point dose measurements in water and lung equivalent inserts. TPS calculated planar dose distributions were compared to those measured using EPID and MapCheck, as an independent verification method. Results were evaluated with gamma criteria of 2% dose difference and 2mm DTA for 95% of points. Results: GBD set vs. measured data passed 2% 2mm 1D gamma analysis even for small fields. Machine performance tests show results are independent of machine delivery configuration, as expected. Absolute point dosimetry comparison resulted within 4% for the worst case scenario in lung. Over 97% of the points evaluated in dose distributions passed gamma index analysis. Conclusion: Eclipse AAA algorithm configuration of the 6 MV high dose rate photon beam using GBD proved efficient. End-to-end test dose calculation results indicate it can be used clinically for SBRT using RapidArc.

60 APPLIED LIFE SCIENCES↗

Evaluation of Canisterized Foams and Evaluation of Radiation Hardened Foams for D&D Activities

The introduction of polyurethane foams has previously been examined elsewhere within the DOE complex with regards to decontamination and decommissioning (D&D) activities, though its use has been prohibited as a result of excessive heat generation and flammability concerns per the safety basis. Should these foams be found compatible with respect to the facility safety basis requirements, D&D work involving large void containing structures such as gloveboxes could be eased through the fixation of residual contamination after decontamination efforts have concluded. To this end, SRNL embarked on a characterization of commercial epoxy foams to identify the characteristics that would be most important to safety basis requirements. Through SRNL’s efforts, the performance of commercial two-part epoxy foams was evaluated for their foaming characteristics, temperature profiles, loading capability with high-Z (high density) additives, and applicability for shielding gamma emission from isotopes including; Am-241, Cs-137, and Co-60. It was found that these foams are capable of encapsulation of a desired volume, though the ideal and experimental expansion coefficients were found to differ. While heat is generated during the reaction, no samples generated heat above 70 °C. Of the down–selected materials, heating was on the order of 40 °C for the flexible foam and 60 °C for the rigid foam. Both were found to return to room temperature after 20 minutes regardless of the volume of foam cast. It was also found that the direct introduction of high-Z additives were capable of attenuating 98% of Am-241 gamma signal, 16% of Cs-137 signal, and 9.5% of Co-60 signal at 1:1 loading capacities of total liquid constituent weight to additive weight. These efforts are currently being reviewed for the ASTM January 2017 subcommittee discussions to address the lack of test methods and standards regarding these materials with respect to D&D environments.

36 MATERIALS SCIENCE↗

California Price Response Potential Study

California's energy landscape is undergoing a significant transformation, driven by the increasing integration of renewable energy sources, the increased adoption of distributed energy resources, the electrification of end-use loads, and the growing need for grid efficiency. To address these challenges, recent revisions to the State’s Load Management Standards (LMS) require all of California’s large utilities and community choice aggregators (CCAs) to offer dynamic electricity pricing options to customers by 2027. Dynamic pricing, which involves varying electricity rates based on real-time supply and demand conditions, offers a promising solution for optimizing grid operations, reducing costs, and incentivizing efficient use of grid capacity. Effective implementation of dynamic pricing requires understanding the potential impacts on customer bills, system load, and the cost-effectiveness of automation technologies. This study aims to evaluate the load response of various end-use devices to hourly dynamic prices. The end-uses studied here are space cooling, space heating, water heating, crop irrigation, pool and spa pumps, and electric vehicle (EV) charging, all for both residential and commercial applications, except for crop irrigation. In 2030, these end uses are forecasted to account for 18% of annual electricity demand in the state, but 40% of demand in the peak net load hour. By modeling possible price-responsive load dispatch algorithms and assessing the resulting impacts on both individual bills and the overall grid, we seek to inform policymakers and utilities about the potential benefits and challenges associated with dynamic pricing, and considerations for the design of dynamic pricing tariffs. Additionally, we will explore the cost effectiveness of adopting automation technologies to enable devices to respond more effectively to real-time price signals. This study considers a range of price profiles, accounting for differences across utilities and customer classes, and presents scenarios for dynamic price design via variation in the percentage of total customer electric costs that are allocated dynamically (versus constituting a fixed portion of the hourly volumetric price). We present results focused primarily on 2030, forecasting electricity prices under both low and high-cost scenarios, to inform longer-term tariff design considerations. We design tariffs by starting with 2019 prices that were calculated according to CalFUSE guidance (CPUC, 2022) and that have been used in recent studies; these prices are all-in volumetric rates that vary by utility and are revenue-neutral to each customer class. They are developed by considering six electricity cost components that are allocated hourly based on system load indicators (gross and net load, and wholesale prices). These prices are forecasted to 2030 for low and high cost scenarios, considering recent trends in total electricity costs with and without years of substantial wildfire mitigation investments. These tariffs, which allocate all costs on an hourly basis, are considered our “Full” dynamic tariff design scenario, while two additional scenarios explore allocating a portion of costs as a flat volumetric charge: the “Medium” scenario allocates 50% of revenue dynamically (and keeps 50% flat), while the “Mild” scenario allocates 20% of revenue dynamically. The 20% dynamic allocation on the Mild scenario aims to represent a case where only the marginal operating costs of the grid are included in the dynamic price.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Transport and Retention of Concentrated Oil-in-Water Emulsions in Porous Media

Oil-in-water emulsions are routinely used in subsurface remediation. In these applications, high oil loadings present a challenge to remedial design as mechanistic insights into transport and retention of concentrated emulsions is limited. In this paper, column experiments were designed to examine emulsion transport and retention over a range of input concentrations (1.3–23% wt). Droplet breakthrough and retention data from low concentration experiments were successfully described by existing particle transport models. These models, however, failed to capture droplet transport in more concentrated systems. At high oil fraction, breakthrough curves exhibited an early fall at the end of the emulsion pulse and extending tailing. Irrespective of input concentration, all retention profiles displayed hyper-exponential behavior. Here, we extended existing model formulations to include the additional mixing processes occurring when at high oil concentrations—with focus on the influence of deposited mass and viscous instabilities. The resulting model was parametrized with low concentration data and can successfully predict concentrated emulsion transport and retention. Finally, the role of retained mass and viscous instabilities on mixing conditions can also be applied more broadly to systems with temporal or spatially variant water saturation or when viscosity contrasts exist between fluids.

54 ENVIRONMENTAL SCIENCES↗

Simultaneous Thermal Analysis of Anion and Cation Exchange Resins

The decomposition reactions of one anion exchange resin (Bio-Rad AG MP-1) and one cerium-loaded cation exchange resin (DOWEX 50W-X8), both in nitrate form, were analyzed using simultaneous thermal analysis methods. Thermogravimetric analysis, dynamic scanning calorimetry, and evolved gas analysis were deployed in combination to probe the temperature profiles, reaction enthalpies, and off-gases from these resins under process-relevant temperature ranges. Analysis indicates that both resins undergo three clear phases during heating. The first is a dehydration step with prominent off-gassing of water, the second is a decomposition step with evolution of several gaseous species, and lastly is a combustion step with a large release of CO 2 . The temperature at which combustion ends varies slightly between AG MP-1 and DOWEX 50W: combustion completed at ~690°C and ~810°C, respectively. For the DOWEX cation resin, the combustion reaction showed greater sensitivity to the availability of oxygen under the test conditions. Both resins displayed broad exotherms during the combustion step of the decomposition, but the DOWEX cation resin demonstrated a 4.5 times higher specific enthalpy than that of the AG MP-1.

36 MATERIALS SCIENCE↗