Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electronic Procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Development of a Method for Measurement of Photonuclear-Reaction Cross Sections with the Aid of Simulated Quasimonoenergetic-Photon Spectra

A procedure for measuring photonuclear-reaction cross sections by employing the method of quasimonochromatization of the bremsstrahlung photon spectrum is developed. This procedure permits determining reaction cross sections via measuring the reaction yield at three fixed values of the electron energy. The procedure is equivalent to measuring the cross section in question for quasimonochromatic photons. Bremsstrahlung-photon spectra are obtained using state-of-the-art simulation means involving the GEANT4 code as applied to a specific experiment with allowance for its geometry, target thicknesses, electron-beam parameters, etc. The results obtained by simulating quasimonochromatic distributions of bremsstrahlung photons are presented for experiments at the LUE-8-5 linear electron accelerator of Institute for Nuclear Research (Moscow, Russian Academy of Sciences). These results are found to be in good agreement with the experimental energy distribution of the cross section for the reaction {sup 111}Cd(γ, γ') in the energy range between 5 and 8 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A perturbative formalism for electronic transitions through conical intersections in a fully quadratic vibronic model

We consider a fully quadratic vibronic model Hamiltonian for studying photoinduced electronic transitions through conical intersections. Using a second order perturbative approximation for diabatic couplings, we derive an analytical expression for the time evolution of electronic populations at a given temperature. This formalism extends upon a previously developed perturbative technique for a linear vibronic coupling Hamiltonian. The advantage of the quadratic model Hamiltonian is that it allows one to use separate quadratic representations for potential energy surfaces of different electronic states and a more flexible representation of interstate couplings. We explore features introduced by the quadratic Hamiltonian in a series of 2D models, and then apply our formalism to the 2,6-bis(methylene) adamantyl cation and its dimethyl derivative. The Hamiltonian parameters for the molecular systems have been obtained from electronic structure calculations followed by a diabatization procedure. The evolution of electronic populations in the molecular systems using the perturbative formalism shows a good agreement with that from variational quantum dynamics.

74 ATOMIC AND MOLECULAR PHYSICS↗

Standardized Procedure Content And Data Structure Based On Human Factors Requirements For Computer-Based Procedures

Most activities that involve human interaction with systems in a nuclear power plant are guided by procedures. Traditionally, the use of procedures has been a paper-based process that supports safe operation of the nuclear power industry. However, the nuclear industry is constantly trying to find ways to decrease the human error rate, especially the human errors associated with procedure use. Advances in digital technology make computer-based procedures (CBPs) a valid option that provides further enhancement of safety by improving human performance related to procedure use. The transition from paper-based procedures (PBPs) to CBPs creates a need for a computer-based procedure system (CBPS). A CBPS needs to have the ability to perform logical operations in order to adjust to the inputs received from either users or real time data from plant status databases. Without the ability for logical operations the procedure is just an electronic copy of the paper-based procedure. In order to provide the CBPS with the information it needs to display the procedure steps to the user, special care is needed in the format used to deliver all data and instructions to create the steps. The procedure should be broken down into basic elements and formatted in a standard method for the CBPS. One way to build the underlying data architecture is to use an Extensible Markup Language (XML) schema, which utilizes basic elements to build each step in the smart procedure. The attributes of each step will determine the type of functionality that the system will generate for that step. The CBPS will provide the context for the step to deliver referential information, request a decision, or accept input from the user. The XML schema needs to provide all data necessary for the system to accurately perform each step without the need for the procedure writer to reprogram the CBPS. The research team at the Idaho National Laboratory has developed a prototype CBPS for field workers as well as the underlying data structure for such CBPS. The objective of the research effort is to develop guidance on how to design both the user interface and the underlying schema. This paper will describe the result and insights gained from the research activities conducted to date.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Time-Dependent, Three-Dimensional Simulation of Free-Electron-Laser Oscillators

We describe a procedure for the simulation of free-electron-laser (FEL) oscillators. The simulation uses a combination of the MEDUSA simulation code for the FEL interaction and the OPC code to model the resonator. The simulations are compared with recent observations of the oscillator at the Thomas Jefferson National Accelerator Facility and are in substantial agreement with the experiment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cryogenic Quenching Process for Electronic Part Screening

The use of electronic parts at cryogenic temperatures (less than 100 C) for extreme environments is not well controlled or developed from a product quality and reliability point of view. This is in contrast to the very rigorous and well-documented procedures to qualify electronic parts for mission use in the 55 to 125 C temperature range. A similarly rigorous methodology for screening and evaluating electronic parts needs to be developed so that mission planners can expect the same level of high reliability performance for parts operated at cryogenic temperatures. A formal methodology for screening and qualifying electronic parts at cryogenic temperatures has been proposed. The methodology focuses on the base physics of failure of the devices at cryogenic temperatures. All electronic part reliability is based on the bathtub curve, high amounts of initial failures (infant mortals), a long period of normal use (random failures), and then an increasing number of failures (end of life). Unique to this is the development of custom screening procedures to eliminate early failures at cold temperatures. The ability to screen out defects will specifically impact reliability at cold temperatures. Cryogenic reliability is limited by electron trap creation in the oxide and defect sites at conductor interfaces. Non-uniform conduction processes due to process marginalities will be magnified at cryogenic temperatures. Carrier mobilities change by orders of magnitude at cryogenic temperatures, significantly enhancing the effects of electric field. Marginal contacts, impurities in oxides, and defects in conductor/conductor interfaces can all be magnified at low temperatures. The novelty is the use of an ultra-low temperature, short-duration quenching process for defect screening. The quenching process is designed to identify those defects that will precisely (and negatively) affect long-term, cryogenic part operation. This quenching process occurs at a temperature that is at least 25 C colder than the coldest expected operating temperature. This quenching process is the opposite of the standard burn-in procedure. Normal burn-in raises the temperature (and voltage) to activate quickly any possible manufacturing defects remaining in the device that were not already rejected at a functional test step. The proposed inverse burn-in or quenching process is custom-tailored to the electronic device being used. The doping profiles, materials, minimum dimensions, interfaces, and thermal expansion coefficients are all taken into account in determining the ramp rate, dwell time, and temperature.

Sheldon, Douglas J.↗

Optimal Geometry for Focused Ion Beam-Milled Samples for Direct-Pull Micro-Tensile Testing Performed In Situ in a Scanning Electron Microscope

A thorough procedure was developed to efficiently manufacture dogbone samples using focused ion beam (FIB) milling for micro-tensile testing. A Bruker PI 89 PicoIndenter, Billerica, MA, USA, was used as a case study, although the analysis and results are applicable to other micro-mechanical testing systems capable of mounting a standard, Ø12.7 mm × Ø3.2 mm pin, scanning electron microscopy (SEM) pin stub (Ted Pella, Redding, CA, USA). Nine dogbones were made from an Fe-45Cu alloy additively manufactured using powder-fed laser-directed energy deposition (DED-LB). Testing showed that fracture was confined to the gauge section for all dogbones and that the fracture mode, ductile vs. brittle, was entirely dependent on the grain orientation relative to the loading direction. The analysis showed that the measured plastic strain to failure can vary from >11% (optimal geometry) to <1% (non-optimal geometry) in micro-tensile testing of high-tensile-strength (>1 GPa) metallic materials. Subsequently, a finite element analysis (FEA) was conducted to identify the improved dogbone geometries. A total of ten thousand dogbone geometries were tested, and their dimensions were defined by a set of four adjustable parameters (corner radius, load surface angle, load surface length, and dogbone head length). The gauge width and gauge length were fixed to 4 µm and 10 µm, respectively. Three-dimensional surface plots of the stress concentration as a function of two parameters were used to identify the optimal ranges of parameter values. The addition of maximum width and length constraints, measuring 25 µm and 30 µm, respectively, allowed us to identify an optimal geometry at load surface angles of 30° and 45°. Their respective dimensions (corner radius, load surface length, and dogbone head length) are, in µm, 12, 6, and 7 and 10, 7, and 7. Testing these two optimal geometries with a range of gauge lengths from 4 to 20 µm showed that smaller gauge lengths only slightly reduced the detrimental stress concentration outside the gauge section. However, smaller gauge lengths will notably improve the FIB surface polishing step as tapering is reduced with smaller dogbone lengths.

Chemistry↗

Voyager electronic parts radiation program. Volume 2: Test requirements and procedures

Documents are presented outlining the conditions and requirements of the test program. The Appendixes are as follows: appendix A -- Electron Simulation Radiation Test Specification for Voyager Electronic Parts and Devices, appendix B -- Electronic Piece-Part Testing Program for Voyager, appendix C -- Test Procedure for Radiation Screening of Voyager Piece Parts, appendix D -- Boeing In Situ Test Fixture, and appendix E -- Irradiate - Anneal (IRAN) Screening Documents.

Stanley, A. G.↗

Electron-positron pair production by ultrarelativistic electrons in a soft photon field

The fully differential cross section for photon-electron pair production is integrated numerically over phase space. Results are obtained for the astrophysically interesting case in which the interaction between an ultrarelativistic electron and a soft photon results in electron-positron pair production. The positron spectrum is a function of the energies of both the photon and the electron, as well as the angle of interaction. It is found that the energy at which the positron distribution peaks is inversely proportional to the photon energy and independent of the electron energy. The positron spectrum is integrated once more over initial electron energies for a power-law energy distribution of primary electrons. The same procedure is repeated for the recoil particle; it is shown that the peak of the recoil energy distribution depends linearly on the energy of the primary electron. Finally, semianalytical expressions are obtained for the energy losses of the primary electrons.

Mastichiadis, A.↗

Surface applicator calibration and commissioning of an electronic brachytherapy system for nonmelanoma skin cancer treatment

Purpose: The Xoft Axxent x-ray source has been used for treating nonmelanoma skin cancer since the surface applicators became clinically available in 2009. The authors report comprehensive calibration procedures for the electronic brachytherapy (eBx) system with the surface applicators. Methods: The Xoft miniature tube (model S700) generates 50 kVp low-energy x rays. The new surface applicators are available in four sizes of 10, 20, 35, and 50 mm in diameter. The authors' tests include measurements of dose rate, air-gap factor, output stability, depth dose verification, beam flatness and symmetry, and treatment planning with patient specific cutout factors. The TG-61 in-air method was used as a guideline for acquiring nominal dose-rate output at the skin surface. A soft x-ray parallel-plate chamber (PTW T34013) and electrometer was used for the output commissioning. GafChromic EBT films were used for testing the properties of the treatment fields with the skin applicators. Solid water slabs were used to verify the depth dose and cutout factors. Patients with basal cell or squamous cell carcinoma were treated with eBx using a calibrated Xoft system with the low-energy x-ray source and the skin applicators. Results: The average nominal dose-rate output at the skin surface for the 35 mm applicator is 1.35 Gy/min with {+-}5% variation for 16 sources. The dose-rate output and stability (within {+-}5% variation) were also measured for the remaining three applicators. For the same source, the output variation is within 2%. The effective source-surface distance was calculated based on the air-gap measurements for four applicator sizes. The field flatness and symmetry are well within 5%. Percentage depth dose in water was provided by factory measurements and can be verified using solid water slabs. Treatment duration was calculated based on the nominal dose rate, the prescription fraction size, the depth dose percentage, and the cutout factor. The output factor needs to be measured for each case with varying shapes of cutouts. Conclusions: Together with TG-61, the authors' methodology provides comprehensive calibration procedures for medical physicists for using the Xoft eBx system and skin applicators for nonmelanoma skin cancer treatments.

60 APPLIED LIFE SCIENCES↗

The radiation protection principles model as a tool in the e-waste procedures

The electrical and electronic waste (e-waste) management is a global environmental problem dominated by the precautionary principle application, resulted to preliminary and ambiguous potential adverse effects, of extensive scientific uncertainty. In order to overcome the detected stochastic effects confusions in this field, we propose the inclusion of the principles of justification-optimization-limitation and of prudent avoidance. This model is already, established in radiation protection, so that toxicity as a result of the e-waste management would decrease, whilst the precious metals would be saved. We, further, resolve the classification of rejected items as reusable or as waste, so that the procedure of dismantling and recycling becomes easier, and the collecting-transporting-placement at an e-waste landfill would be safer. In conclusion, our proposing pattern in the e-waste management enforces the sustainable reducing-reusing-recycling, saves time/money and advances safety by including more sources of e-waste (military, medical etc) that were excluded previously.

54 ENVIRONMENTAL SCIENCES↗

Determination of g-tensors of low-symmetry Nd{sup 3+} centers in LiNbO{sub 3} by rectification of angular dependence of electron paramagnetic resonance spectra

Two procedures for facilitation of line tracing and deciphering of complicated spectra of electron paramagnetic resonance (EPR) were developed: a correction of microwave frequencies for every orientation of external magnetic field on the base of known values of g-tensor components for a reference paramagnetic center and followed rectification of measured angular dependences using plots of effective deviation of g{sup 2}-factors of observed lines from effective g{sup 2}-factors of the reference center versus angles or squared cosines of angles describing magnetic field orientations. Their application to EPR spectra of nearly stoichiometric lithium niobate crystals doped with neodymium allowed identifying two axial and six different low-symmetry Nd{sup 3+} centers, to determine all components of their g-tensors, and to propose common divacancy models for a whole family of Nd{sup 3+} centers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design and Testing of a Prototype Beam Absorber for the PXIE MEBT

One of the goals of the PXIE at Fermilab is to demonstrate the capability to form an arbitrary bunch pattern from an initially CW 162.5 MHz H- bunch train coming out of an RFQ. The bunch-by-bunch selection will take place in the 2.1 MeV Medium Energy Beam Transport (MEBT) by directing the undesired bunches onto an absorber that needs to withstand a beam power of up to 21 kW, focused onto a spot with a ~2 mm rms radius. A design was developed to respond to the driving requirements: high surface power density of 17W/mm 2 and resistance to ion-induced surface blistering. A ¼ - size prototype of the absorber was manufactured, and its thermal properties were tested with an electron beam generating a peak power density similar to the one expected during normal operation of the PXIE beam line. The note describes the absorber concept, the prototype, the testing procedure with the electron beam, and the results of testing.

Baffes, Curtis M.↗

The NASA Constellation Program Procedure System

NASA has used procedures to describe activities to be performed onboard vehicles by astronaut crew and on the ground by flight controllers since Apollo. Starting with later Space Shuttle missions and the International Space Station, NASA moved forward to electronic presentation of procedures. For the Constellation Program, another large step forward is being taken - to make procedures more interactive with the vehicle and to assist the crew in controlling the vehicle more efficiently and with less error. The overall name for the project is the Constellation Procedure Applications Software System (CxPASS). This paper describes some of the history behind this effort, the key concepts and operational paradigms that the work is based upon, and the actual products being developed to implement procedures for Constellation

Phillips, Robert G.↗

Microstructure and 77K mechanical properties of electron beam welded Cu101- Inconel 625 joints

In developing large-scale next-generation superconducting radio frequency (SRF) linear accelerators using superconducting films on Cu, the design and development of dissimilar welding and joining metals, such as Cu to Inconel, stainless steel, and Nb, are essential. In this talk, we present the development of procedures for electron-beam welding of Cu¿Inconel 625 and evaluation of the microstructure and 77K mechanical properties of the weld and base material in the welded condition and heat treatments in the 750°C ¿950°C heat treatment range. The results will be presented in the context of developing joining techniques for low-temperature applications where high conductivity and strength, vacuum hygiene, and magnetic properties of the material need consideration. The methods presented here are being deployed to thin film SRF Cu cavities at Jefferson Lab. Acknowledgment: This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Nuclear

Khanal, Bashu↗

Measurement of the total spectrum of electrons and positrons in the energy range of 300–1500 GeV in the PAMELA experiment with the aid of a sampling calorimeter and a neutron detector

A method based on the use of a sampling calorimeter was developed for measuring the total energy spectrum of electrons and positrons from high-energy cosmic rays in the PAMELA satellite-borne experiment. This made it possible to extend the range of energies accessible to measurements by the magnetic system of the PAMELA spectrometer. Themethod involves a procedure for selecting electrons on the basis of features of a secondary-particle shower in the calorimeter. The results obtained by measuring the total spectrum of cosmic-ray electrons and positrons in the energy range of 300–1500 GeV by the method in question are presented on the basis of data accumulated over a period spanning 2006 and 2013.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A simple correction for the Born approximation for electron impact excitation of hydrogenic ions

An analytic procedure is developed for obtaining the electron impact excitation cross sections for hydrogenic ions. A simple modification of the Born approximation, in order to include Coulomb focusing of the continuum wave functions, produces the correct energy dependence of the cross section near excitation threshold. This procedure is used to compute the 1s yields 2s and 1s yields 2p excitation cross sections for hydrogenic ions (Z approaches infinity), and compare these modified-Born cross sections with numerical Colomb-Born calculations. The modified-Born cross sections agree well with the Coulomb-Born cross sections and thus provide a reliable generalized analytic expression for electron impact excitation of hydrogenic ions. By treating effective charges, the results in this work can be extended to nonhydrogenic target systems.

Jung, Young-Dae↗