Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electron microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Volume changes upon heating of aerosol particles from biomass burning using transmission electron microscopy

The responses of aerosol particles to heating are important for measurements of their chemical, physical, and optical properties, classification, and determination of origin. However, the thermal behavior of organic aerosol particles is largely unknown. We provide a method to analyze such thermal behavior through heating from room temperature to >600°C by using a heating holder within a transmission electron microscope (TEM). Here we describe in-situ shape and size changes and variations in the compositions of individual particles before and after heating. We use ambient samples from wildland and agricultural biomass fires in North America collected during the 2013 Biomass Burn Observation Project (BBOP). The results indicate that individual tar balls (TB; spherical organic material) from biomass burning retained, on average, up to 30% of their volume when heated to 600°C. Chemical analysis reveals that K and Na remain in the residues, whereas S and O were lost. In contrast to bulk sample measurements of carbonaceous particles using thermal/optical carbon analyzers, our single-particle results imply that many individual organic particles consist of multiple types of organic matter having different thermal stabilities. Beyond TBs, our results suggest that because of their thermal stability some organic particles may not be detectable by using aerosol mass spectrometry or thermal/optical carbon analyzers. This result can lead to an underestimate of the abundance of TBs and other organic particles, and therefore biomass burning may have more influence than currently recognized in regional and global climate models.

Adachi, Kouji↗

Transmission Electron Microscopy Studies of Electron-Selective Titanium Oxide Contacts in Silicon Solar Cells

Abstract In this study, the cross-section of electron-selective titanium oxide (TiO 2 ) contacts for n -type crystalline silicon solar cells were investigated by transmission electron microscopy. It was revealed that the excellent cell efficiency of 21.6% obtained on n -type cells, featuring SiO 2 /TiO 2 /Al rear contacts and after forming gas annealing (FGA) at 350°C, is due to strong surface passivation of SiO 2 /TiO 2 stack as well as low contact resistivity at the Si/SiO 2 /TiO 2 heterojunction. This can be attributed to the transformation of amorphous TiO 2 to a conducting TiO 2- x phase. Conversely, the low efficiency (9.8%) obtained on cells featuring an a-Si:H/TiO 2 /Al rear contact is due to severe degradation of passivation of the a-Si:H upon FGA.

Materials Science↗

Gas mixing system for imaging of nanomaterials under dynamic environments by environmental transmission electron microscopy

A gas mixing manifold system that is capable of delivering a stable pressure stream of a desired composition of gases into an environmental transmission electron microscope has been developed. The system is designed to provide a stable imaging environment upon changes of either the composition of the gas mixture or upon switching from one gas to another. The design of the system is described and the response of the pressure inside the microscope, the sample temperature, and sample drift in response to flow and composition changes of the system are reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inactivation of Fluorescent Lipid Bilayers by Irradiation With 300 keV Electrons Using Liquid Cell Transmission Electron Microscopy

Liquid cell transmission electron microscopy allows for imaging of samples in a fully hydrated state at high resolution and has the potential for visualizing static or dynamic biological structures. However, the ionizing nature of the electron beam makes it difficult to discern real physiological dynamics from radiation induced artifacts within liquid cell samples. Electron flux thresholds for achieving high resolution structures from biological samples frozen in ice have been described extensively by the cryo-electron microscopy field, while electron flux thresholds which do not result in a functional change for biological samples within the hydrated environment of a transmission electron microscope liquid cell is less clear. Establishing these functional thresholds for biologically relevant samples is important for accurate interpretation of results from liquid cell experiments. Here we demonstrate the electron damage threshold of fluorescently tagged lipid bilayers by quantifying the change in fluorescence before and after electron exposure. We observe the reduction of fluorescent signal in bilayers by 25% after only 0.0005 e − /Å 2 and a reduction of over 90% after 0.01 e − /Å 2 . These results indicate that the loss of function occurs at irradiation thresholds far below a typical single high resolution (scanning) transmission electron microscopy image and orders of magnitude below fluxes used for preserving structural features with cryo-electron microscopy.

Moser, Trevor↗

Investigating phase transformation in the Li1.2Co0.1Mn0.55Ni0.15O2 lithium-ion battery cathode during high-voltage hold (4.5 V) via magnetic, X-ray diffraction and electron microscopy studies

This study is the first that provides evidence of phase transformation in a Li-rich Li1.2Co0.1Mn0.55Ni0.15O2 cathode material for lithium-ion batteries (LIBs) during constant voltage charging. Diffraction and magnetic measurement techniques were successfully implemented to investigate the structural transformation in this cathode material during holding a half-cell at 4.5 V in a charged state. The results from X-ray diffraction showed a decrease in c-lattice parameters during high-voltage hold. Magnetic data revealed an increase in average effective magnetic moments of transition metal (TM) ions at constant voltage corresponding to a change in electronic states of TM ions. Analysis showed the reduction of Ni4+ to Ni2+, which was attributed to charge compensation due to oxygen loss. The appearance of the strong {100} forbidden reflection in the single-crystal selected area electron diffraction (SAED) data was attributed to migration of transition metal ions to the octahedral vacancy sites in the lithium layer during high-voltage hold, which was in agreement with the magnetization results. After prolonged hold at 4.5 V, high-resolution transmission electron microscopy (TEM) images along with SAED results showed the presence of spinel phases in the particles, indicating a layered to spinel like phase transformation at constant voltage in agreement with the magnetic data. The results obtained from these magnetic and diffraction studies furnish the fundamental understanding of the structural transformation pathways in Li-rich cathodes at constant voltage and will be instrumental for modifying the parent structure to achieve greater stability.

Mohanty, Debasish↗

Combining nanocalorimetry and dynamic transmission electron microscopy for in situ characterization of materials processes under rapid heating and cooling

Nanocalorimetry is a chip-based thermal analysis technique capable of analyzing endothermic and exothermic reactions at very high heating and cooling rates. Here, we couple a nanocalorimeter with an extremely fast in situ microstructural characterization tool to identify the physical origin of rapid enthalpic signals. More specifically, we describe the development of a system to enable in situ nanocalorimetry experiments in the dynamic transmission electron microscope (DTEM), a time-resolved TEM capable of generating images and electron diffraction patterns with exposure times of 30 ns–500 ns. The full experimental system consists of a modified nanocalorimeter sensor, a custom-built in situ nanocalorimetry holder, a data acquisition system, and the DTEM itself, and is capable of thermodynamic and microstructural characterization of reactions over a range of heating rates (10{sup 2} K/s–10{sup 5} K/s) accessible by conventional (DC) nanocalorimetry. To establish its ability to capture synchronized calorimetric and microstructural data during rapid transformations, this work describes measurements on the melting of an aluminum thin film. We were able to identify the phase transformation in both the nanocalorimetry traces and in electron diffraction patterns taken by the DTEM. Potential applications for the newly developed system are described and future system improvements are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In situ transmission electron microscopy investigation of the interfacial reaction between Ni and Al during rapid heating in a nanocalorimeter

The Al/Ni formation reaction is highly exothermic and of both scientific and technological significance. In this report, we study the evolution of intermetallic phases in this reaction at a heating rate of 830 K/s. 100-nm-thick Al/Ni bilayers were deposited onto nanocalorimeter sensors that enable the measurement of temperature and heat flow during rapid heating. Time-resolved transmission electron diffraction patterns captured simultaneously with thermal measurements allow us to identify the intermetallic phases present and reconstruct the phase transformation sequence as a function of time and temperature. The results show a mostly unaltered phase transformation sequence compared to lower heating rates.

36 MATERIALS SCIENCE↗

Resolution enhancement in transmission electron microscopy with 60-kV monochromated electron source

Transmission electron microscopy (TEM) at low accelerating voltages is useful to obtain images with low irradiation damage. For a low accelerating voltage, linear information transfer, which determines the resolution for observation of single-layered materials, is largely limited by defocus spread, which improves when a narrow energy spread is used in the electron source. In this study, we have evaluated the resolution of images obtained at 60 kV by TEM performed with a monochromated electron source. The defocus spread has been evaluated by comparing diffractogram tableaux from TEM images obtained under nonmonochromated and monochromated illumination. The information limits for different energy spreads were precisely measured by using diffractograms with a large beam tilt. The result shows that the information limit reaches 0.1 nm with an energy width of 0.10 eV. With this monochromated source and a higher-order aberration corrector, we have obtained images of single carbon atoms in a graphene sheet by TEM at 60 kV.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The material dependence of temperature measurement resolution in thermal scanning electron microscopy

Thermal scanning electron microscopy is a recently developed temperature mapping technique based on thermal diffuse scattering in electron backscatter diffraction in a scanning electron microscope. It provides nano-scale and non-contact temperature mapping capabilities. Due to the specific temperature sensitive mechanism inherent to this technique, the temperature resolution is highly material dependent. A thorough investigation of what material properties affect the temperature resolution is important for realizing the inherent temperature resolution limit for each material. In this paper, three material dependent parameters-the Debye-Waller B-factor temperature sensitivity, backscatter yield, and lattice constant-are shown to control the temperature resolution.

36 MATERIALS SCIENCE↗

In Situ Transmission Electron Microscopy of High-Temperature Inconel-625 Corrosion by Molten Chloride Salts

This paper describes an approach to monitor high temperature molten chloride (MgCl 2 -NaCl-KCl) salt corrosion of Inconel-625 alloy in real time at high spatial resolution. The approach is based on a micro-environmental-cell assembly integrated into a transmission-electron-microscope goniometer to examine in situ the salt-alloy interface during corrosion, employing real time electron diffraction and imaging. It establishes procedures to minimize incorporation of H 2 O or O 2 from atmosphere in the chloride salts during sample fabrication and corrosion, which is critical to understanding the fundamental corrosion mechanisms. A clustering algorithm and a 2D Gaussian fit function are used to determine diffraction spot intensities in in situ diffraction patterns, to quantify alloy corrosion. This facilitates quantitative observation of the evolution of individual grains, in contrast to conventional macroscopic corrosion rate quantification. The isothermal corrosion rate of Inconel-625 in an anhydrous, unoxidized salt-stack is 220 ± 30 μm year -1 at 700 °C and 350 ± 20 μm year -1 at 800 °C. However, the corrosion rate at 700 °C increases five-fold to 1000 ± 170 μm year -1 when the salt stack is air-exposed, indicating the dominant effects of hydrated or oxidized impurities on corrosion acceleration. Furthermore, real time imaging of the microstructure evolution suggests that corrosion is initiated at grain boundaries.

14 SOLAR ENERGY↗

Growth Dynamics and Electron Reflectivity in Ultrathin Films of Chiral Heptahelicene on Metal (100) Surfaces Studied by Spin-Polarized Low Energy Electron Microscopy

Interaction of electrons with chiral matter gives rise to interesting phenomena such as the chirality-induced spin selectivity. The interdependence of reflectivity of spin-polarized low energy electrons and the absolute handedness of chiral molecules is investigated. First, the growth of homochiral films of helical aromatic hydrocarbons, so-called helicenes, on a Cu(100) surface is studied by means of low energy electron microscopy and scanning tunneling microscopy in ultrahigh vacuum. As soon as the coverage exceeds one monolayer, double-layer nucleation and growth is favored such that depletion in the first layer occurs. Spatially resolved work function measurements show that second-layer patches have a lower work function than first-layer areas. Reflectivity spectra of spin-polarized electrons do not show any asymmetry between homochiral films of the enantiomers. Laterally resolved work function measurements do not confirm work function differences such as those reported earlier for photoelectron studies of chiral peptide films on ferromagnetic substrates.

36 MATERIALS SCIENCE↗