Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electromagnetic calorimeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Measurement of ambient radon progeny decay rates and energy spectra in liquid argon using the MicroBooNE detector

We report measurements of radon progeny in liquid argon within the MicroBooNE time projection chamber (LArTPC). The presence of specific radon daughters in MicroBooNE’s 85 metric tons of active liquid argon bulk is probed with newly developed charge-based low-energy reconstruction tools and analysis techniques to detect correlated Bi 214 − Po 214 radioactive decays. Special datasets taken during periods of active radon doping enable new demonstrations of the calorimetric capabilities of single-phase neutrino LArTPCs for β and α particles with electron-equivalent energies ranging from 0.1 to 3.0 MeV. By applying Bi 214 − Po 214 detection algorithms to data recorded over a 46-day period, no statistically significant presence of radioactive Bi 214 is detected, and a limit on the activity is placed at < 0.35 mBq / kg at the 95% confidence level. This bulk Bi 214 radiopurity limit—the first ever reported for a liquid argon detector incorporating liquid-phase purification—is then further discussed in relation to the targeted upper limit of 1 mBq / kg on bulk Rn 222 activity for the DUNE neutrino detector. Published by the American Physical Society 2024

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Advanced, Radiation Resistant, Optical-based Detector Technology for Future Experiments.

The primary objective of this project has been to advance the design of high-performance electromagnetic (EM) calorimeters for future particle physics experiments, to identify and measure the timing, position and energy of electrons, positrons and gamma rays, particularly in high-luminosity environments with intense radiation and pileup conditions. To meet such challenges, the proposed research has focused on the development of ultra-compact, radiation-hard calorimeter modules, to provide excellent timing, spatial, and energy resolution. The work aligns with the DOE’s Basic Research Needs (BRN) for High Energy Physics (HEP) Instrumentation and the research team contributes actively to the Coordinating Panel on Advanced Detectors (CPAD) RDC9 calorimetry collaboration in the USA and the European Committee on Future Accelerators (ECFA) DRD-CALO calorimetry collaboration at CERN, the European Laboratory for Particle Physics located in Geneva, Switzerland. The research builds on the RADiCAL (radiation-hard, ultra-compact) modular sampling calorimeter approach, developed by the research team, which employs dense and very bright optical materials such as LYSO:Ce scintillator plates that are interleaved with very dense tungsten plates to minimize detector size while optimizing performance. The modules are comparable in size to a human index finger, dimensionally 14 mm x 14 mm in cross section and 135 mm in length. And despite the small size, the structure is capable of providing excellent timing and energy resolution. This is facilitated through the use of specialized quartz capillaries filled with wavelength-shifting filaments, positioned at various depths along the length of a module, to collect and guide light signals to silicon photomultipliers (SiPMs) which detect and convert the optical signals to electronic signals for analysis. The primary goals of this project have been: (1) Achieve a timing resolution to σ t ≤ 30 ps for high-energy electrons and photons, important for their association with specific events produced in colliding-beam experiments and for the detection of decays-in-flight of long-lived particles. The project has achieved this goal in beam tests of a single RADiCAL module at CERN, during which a timing resolution of σ t = 27 ps was measured for electrons of energy E = 150 GeV. Based upon a mathematical fit to the data measured over a broad energy range from low energy to high energy, a resolution of σ t ≤ 18 ps has been estimated for electrons of very high (TeV) energy. From these measurements and with further expected technical improvements, the timing resolution should reach σ t ≤ 10 ps, important for searches for discovery physics in upcoming and future experiments. (2) Achieve an energy resolution of σ E / E ≤ 10% / $\sqrt{E}$. The project has yet to achieve this goal, but is close to it, having measured a value of σ E / E ≤ 15.9% / $\sqrt{E}$ using a modular array. Ultimately, the resolution goal is expected to be reached by adjustments to material thicknesses within the modules, which will improve the sampling fraction to measure more precisely the shower energy for lower energy particles. The versatility of the modular RADiCAL approach enables the testing of advanced materials, photosensors and electronics, developed in collaboration with CPAD RDC and ECFA DRD-CALO groups. The structure can distinguish electrons, positrons and gamma rays from hadrons and muons and beam-induced backgrounds, making it a valuable tool in a variety of detector environments, including future circular colliders (FCC-ee, FCC-hh) proposed for the European Laboratory for Particle Physics (CERN), the muon-collider proposed for Fermi National Accelerator Laboratory (Fermilab), and searches for new physics in beam-dump, fixed target and forward-physics experiments. And, while designed with particle physics applications in mind, the technologies developed in this project have the potential for application more broadly in particle and nuclear physics, materials science, and medical physics, underscoring the far-reaching potential of this line of instrumentation research and development.

47 OTHER INSTRUMENTATION↗

CMS High Granularity Calorimeter ECON-D ASIC overview and radiation testing results

The Compact Muon Solenoid (CMS) Experiment’s High Granularity Calorimeter (HGCAL) upgrade replaces the CMS electromagnetic and hadronic endcap calorimeters in preparation for the high-rate and high-radiation environment of the High Luminosity LHC. To effectively use the over 6 million channels of this highly-segmented “imaging” calorimeter, CMS is pioneering very front-end data compression with the Endcap Concentrator (ECON) ASICs – the ECON-T for the trigger path and the ECON-D for the data path. These 65 nm CMOS ASICs are radiation tolerant (200 Mrad) and low-power (< 2.5 mW/channel). In June 2023, we received the first full-functionality prototype of the data path concentrator ASIC, the ECON-D-P1. This talk will present an overview of the ECON-D-P1, summarize functionality and system testing, and present results from both Total Ionizing Dose (TID) and Single Event Effect (SEE) testing campaigns completed in summer 2023, validating the ECON-D radiation tolerant performance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Commissioning of the large-scale lead tungstate scintillating calorimeter

Here, we report on the installation and initial commissioning of a large-scale lead tungstate (PbWO4) scintillating crystal calorimeter developed for high-rate photon detection and precise energy measurement. The calorimeter comprises 1596 high-granularity, high-resolution scintillating crystals optimized for electromagnetic-shower detection over a wide energy range. Scintillation light from each crystal is read out by Hamamatsu R4125 photomultiplier tubes equipped with a custom voltage divider and front-end amplifier to ensure stable gain at high rates. All calorimeter modules were fabricated and characterized using a light-emitting diode–based optical test system prior to installation to verify uniformity and photodetector performance. After installation, the electromagnetic calorimeter was fully integrated into the experiment data acquisition and energy-based trigger systems. The optical response of the modules was equalized using the light-monitoring system, cosmic-ray muons, and photons from Compton-scattering events. Commissioning results demonstrate a reliably calibrated optical response and stable detector performance during the first run. These results validate the calorimeter design and commissioning methodology for large-scale scintillator-based photonic instrumentation.

Analog to digital converters↗

Performance of the CMS High Granularity Calorimeter prototype to charged pion beams of 20–300 GeV/c

The upgrade of the CMS experiment for the high luminosity operation of the LHC comprises the replacement of the current endcap calorimeter by a high granularity sampling calorimeter (HGCAL). The electromagnetic section of the HGCAL is based on silicon sensors interspersed between lead and copper (or copper tungsten) absorbers. The hadronic section uses layers of stainless steel as an absorbing medium and silicon sensors as an active medium in the regions of high radiation exposure, and scintillator tiles directly read out by silicon photomultipliers in the remaining regions. As part of the development of the detector and its readout electronic components, a section of a silicon-based HGCAL prototype detector along with a section of the CALICE AHCAL prototype was exposed to muons, electrons and charged pions in beam test experiments at the H2 beamline at the CERN SPS in October 2018. The AHCAL uses the same technology as foreseen for the HGCAL but with much finer longitudinal segmentation. The performance of the calorimeters in terms of energy response and resolution, longitudinal and transverse shower profiles is studied using negatively charged pions, and is compared to GEANT4 predictions. This is the first report summarizing results of hadronic showers measured by the HGCAL prototype using beam test data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision inclusive Higgs physics at e+e- colliders with tracking detectors and without calorimetry

A primary goal of a future e + e - collider program will be the precision measurement of Higgs boson properties. For practical reasons it is of interest to determine the minimal set of detector specifications required to reach this and other scientific goals. Here we investigate the precision obtainable for the e + e - Zh μ + μ - X inclusive cross section and the Higgs boson mass using the di-muon recoil method, considering a detector that has only an inner tracking system within a solenoidal magnetic field, surrounded by many nuclear interaction lengths of absorbing material, and an outer muon identification system. We find that the sensitivity achievable in these measurements with such a tracking detector is only marginally reduced compared to that expected for a general purpose detector with additional electromagnetic and hadronic calorimeter systems. The difference results mainly from multi-photon backgrounds that are not as easily rejected with tracking detectors. We also comment on the prospects for an analogous measurement of the e + e - → Zh → e + e - X inclusive cross section. Finally, we study searches for light scalars utilizing the di-muon recoil method, estimating the projected reach with a tracking or general purpose detector.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Lepton-nucleus cross section measurements for DUNE with the LDMX detector

We point out that the LDMX (Light Dark Matter eXperiment) detector design, conceived to search for sub-GeV dark matter, will also have very advantageous characteristics to pursue electron-nucleus scattering measurements of direct relevance to the neutrino program at DUNE and elsewhere. These characteristics include a 4-GeV electron beam, a precision tracker, electromagnetic and hadronic calorimeters with near 2 π azimuthal acceptance from the forward beam axis out to ~ 40 ° angle, and low reconstruction energy threshold. LDMX thus could provide (semi)exclusive cross section measurements, with detailed information about final-state electrons, pions, protons, and neutrons. We compare the predictions of two widely used neutrino generators ( genie , g i buu ) in the LDMX region of acceptance to illustrate the large modeling discrepancies in electron-nucleus interactions at DUNE-like kinematics. We argue that discriminating between these predictions is well within the capabilities of the LDMX detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Learning to identify electrons

In this report we investigate whether state-of-the-art classification features commonly used to distinguish electrons from jet backgrounds in collider experiments are overlooking valuable information. A deep convolutional neural network analysis of electromagnetic and hadronic calorimeter deposits is compared to the performance of typical features, revealing a ≈ 5% gap which indicates that these lower-level data do contain untapped classification power. To reveal the nature of this unused information, we use a recently developed technique to map the deep network into a space of physically interpretable observables. We identify two simple calorimeter observables which are not typically used for electron identification, but which mimic the decisions of the convolutional network and nearly close the performance gap.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Global polarization of hyperons and spin alignment of vector mesons in quark matters

Relativistic heavy ion collider (RHIC) as a dedicated nuclear facility has made a few major discoveries in physics. This year marks the 30th year STAR Collaboration formation and the 23th year of STAR detector operation and data collection at RHIC. In the last two decades, STAR has collected many datasets, exhibiting scientific versatility and flexibility of the RHIC facility. The total dataset in the first year is less than 1 million good events, and currently there are about 1 billion events per dataset. The Global Hyperon Polarization was proposed in 2004. This immediately prompted the STAR Collaboration to search for this phenomenon from the early datasets. The null results were presented at Quark Matter Conference in Shanghai in 2006 and subsequently published. Although there were peripheral and continuous efforts in the following decade, no positive result has been observed experimentally. This situation changed in the following decade with the upgrade of high data rate and time-of-flight (TOF) detector and the progress of the Beam Energy Scan Phase I (BES-I). The experimental discoveries of the global polarization of hyperons in 2017 and the spin alignment of vector mesons in 2023 at RHIC-STAR confirm the theory which was established nearly twenty years ago. The theory and these measurements open the way to studying the properties of the hot and dense nuclear matter created in high-energy heavy ion collisions from a new degree of freedom, spin. We briefly review these discoveries from the proposals of theory to the experimental measurements, and summarize the related measurements at the existing facilities and the theoretical explanations to the original proposal. The basic understanding and the original proposal are still valid and fundamental, that is, the angular momentum of system can transform into a spin effect observable in experiment. However, it appears that in each case a new model is needed to explain the new experimental observation. We need a more basic theory to help us unify all these spin related phenomena. Over the past five years, STAR has successfully installed 3 new detectors and we have begun to see the physical analysis results from datasets with those new functions. What makes the STAR detector viable after 20 years of operation is its continuous evolution through successful upgrades, with new scientific programs added year by year. The next big thing is to forward upgrade a tracking system (3 layers of silicon strips and 4 layers of sTGC chambers) and a calorimetry system (electromagnetic and hadronic calorimeters). In addition to studying the spin structure of protons by using the polarized proton beams at RHIC, the upgrades also provide a unique ability to investigate the origin of Λ Global Polarization as a function of rapidity and rapidity (de-)correlations in Au+Au collisions.

Physics↗

An apparatus for the specific heat measurement of undercooled liquids

This paper describes a drop calorimeter with an electromagnetic levitator that was specifically built for enthalpy measurements of undercooled liquids, including high-melting-point metals. Design diagrams of this device and of a furnace for making a suspended drop are presented together with results of measurements on an aluminum sample.

Ohsaka, K.↗

Data Analysis for the Scintillating Optical Fiber Calorimeter (SOFCAL)

The scintillating optical fiber calorimeter is a hybrid instrument with both active and passive components for measuring the proton and helium cosmic ray spectra from 0.2 to IO TeV kinetic energy. A thin emulsion/x-ray film chamber is situated between a cerenkov counter and an imaging calorimeter. Scintillating optical fibers sample the electromagnetic showers that develop in the calorimeter and identify the trajectory of cosmic rays that interact in SOFCAL. The emulsion/x-ray film data provide an in flight calibration for SOFCAL. The data reduction techniques used will be discussed and interim results of the analysis from a 20 hour balloon flight will be presented.

Christl, Mark J.↗

Energy Calibration of the Scintillating Optical Fiber Calorimeter Chamber (SOFCAL)

The Scintillating Optical Fiber Calorimeter (SOFCAL) detector is designed to make direct measures of the primary cosmic ray spectrum from -200 GeV/amu - 20 TeV/amu. The primary particles are resolved into groups according to their charge (p, He, CNO, Medium Z, Heavy Z) using both active and passive components integrated into the detector. The principal part of SOFCAL is a thin ionization calorimeter that measures the electromagnetic cascades that result from these energetic particles interacting in the detector. The calorimeter is divided into two sections: a thin passive emulsion/x-ray film calorimeter, and a fiber calorimeter that uses crossing layers of small scintillating optical fibers to sample the energy deposition of the cascades. The energy determination is made by fitting the fiber data to transition curves generated by Monte Carlo simulations. The fiber data must first be calibrated using the electron counts from the emulsion plates in the calorimeter for a small number of events. The technique and results of this calibration will be presented together with samples of the data from a balloon flight.

Christl, M. C.↗

Calibration of the CMS hadron calorimeters using proton-proton collision data at √ s = 13 TeV

Methods are presented for calibrating the hadron calorimeter system of the CMS detector at the LHC. The hadron calorimeters of the CMS experiment are sampling calorimeters of brass and scintillator, and are in the form of one central detector and two endcaps. These calorimeters cover pseudorapidities |η| < 3 and are positioned inside the solenoidal magnet. An outer calorimeter, outside the magnet coil, covers |η| < 1.26, and a steel and quartz-fiber Cherenkov forward calorimeter extends the coverage to |η| < 5.19. The initial calibration of the calorimeters was based on results from test beams, augmented with the use of radioactive sources and lasers. The calibration was improved substantially using proton-proton collision data collected at √ s = 7 , 8, and 13 TeV, as well as cosmic ray muon data collected during the periods when the LHC beams were not present. The present calibration is performed using the 13 TeV data collected during 2016 corresponding to an integrated luminosity of 35.9 fb -1 . The intercalibration of channels exploits the approximate uniformity of energy collection over the azimuthal angle. The absolute energy scale of the central and endcap calorimeters is set using isolated charged hadrons. The energy scale for the electromagnetic portion of the forward calorimeters is set using Z→ ee data. The energy scale of the outer calorimeters has been determined with test beam data and is confirmed through data with high transverse momentum jets. In this paper, we present the details of the calibration methods and accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CMS Barrel Calorimeter Processor demonstrator (BCPv1) board evaluation

For the CERN LHC phase 2, the barrel region of the CMS electromagnetic (ECAL EB) and hadronic calorimeters (HCAL HB) require new back-end electronics for their readout. To this purpose, a first version of the ATCA-based blade, the Barrel Calorimeter Processor (BCPv1), has been developed. The performance of the optical links as well as clock distribution are also presented here. Here, the BCPv1 has been tested together with front-end and trigger boards, as well as with the new DAQ and TCDS Hub (DTH) [1], to demonstrate that the BCPv1 meets the required specifications.

47 OTHER INSTRUMENTATION↗