Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EXHAUST SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Electrically heated particulate filter enhanced ignition strategy

An exhaust system that processes exhaust generated by an engine is provided. The system generally includes a particulate filter (PF) that filters particulates from the exhaust wherein an upstream end of the PF receives exhaust from the engine. A grid of electrically resistive material is applied to an exterior upstream surface of the PF and selectively heats exhaust passing through the grid to initiate combustion of particulates within the PF. A catalyst coating applied to at least one of the PF and the grid. A control module estimates a temperature of the grid and controls the engine to produce a desired exhaust product to increase the temperature of the grid.

42 ENGINEERING↗

Electrically heated particulate filter embedded heater design

An exhaust system that processes exhaust generated by an engine is provided. The system generally includes a particulate filter (PF) that filters particulates from the exhaust wherein an upstream end of the PF receives exhaust from the engine and wherein an upstream surface of the particulate filter includes machined grooves. A grid of electrically resistive material is inserted into the machined grooves of the exterior upstream surface of the PF and selectively heats exhaust passing through the grid to initiate combustion of particulates within the PF.

42 ENGINEERING↗

Turbo-generator control with variable valve actuation

An internal combustion engine incorporating a turbo-generator and one or more variably activated exhaust valves. The exhaust valves are adapted to variably release exhaust gases from a combustion cylinder during a combustion cycle to an exhaust system. The turbo-generator is adapted to receive exhaust gases from the exhaust system and rotationally harness energy therefrom to produce electrical power. A controller is adapted to command the exhaust valve to variably open in response to a desired output for the turbo-generator.

33 ADVANCED PROPULSION SYSTEMS↗

Mixer nozzle aeroacoustic characteristics for the energy efficient engine

Aeroacoustic tests are conducted on scale model mixer nozzle configurations, a separate flow nozzle, and a baseline conical nozzle in an anechoic chamber free-jet facility to investigate exhaust system designs. Far-field acoustic data and exhaust jet plume aerodynamic data are obtained for various combinations of exhaust jet velocity and simulated flight speed, with corrected microphone data at a constant 12.2 m arc distance, and scaled acoustic data at a sideline distance of 457 m. It is found that jet plume aerodynamic and acoustic characteristics of lobed mixer exhaust systems are similar to those of a conical nozzle operating at the same specific thrust, although differences occur at high frequencies, where the sound pressure level of the mixer nozzle is 1-5 dB higher than that of a conical nozzle. In addition, no direct correlation is found between exit plane turbulence levels and plume development or acoustic characteristics for mixer exhaust configurations.

Gliebe, P. R.↗

Zone heated inlet ignited diesel particulate filter regeneration

An exhaust system that processes exhaust generated by an engine is provided. The system includes: a particulate filter (PF) that is disposed downstream of the engine and that filters particulates from the exhaust; and a grid that includes electrically resistive material that is segmented by non-conductive material into a plurality of zones and wherein the grid is applied to an exterior upstream surface of the PF.

42 ENGINEERING↗

Aero-acoustic tests of duct-burning turbofan exhaust nozzles

The acoustic and aerodynamic characteristics of several exhaust systems suitable for duct burning turbofan engines are evaluated. Scale models representing unsuppressed coannular exhaust systems are examined statically under varying exhaust conditions. Ejectors with both hardwall and acoustically treated inserts are investigated.

Kozlowski, H.↗

White Paper for U.S. Army Rapid Equipping Force: Waste Heat Recovery with Thermoelectric and Lithium-Ion Hybrid Power System

By harvesting waste heat from engine exhaust and storing it in light-weight high-capacity modules, it is believed that the need for energy transport by convoys can be lowered significantly. By storing this power during operation, substantial electrical power can be provided during long periods of silent operation, while the engines are not operating. It is proposed to investigate the potential of installing efficient thermoelectric generators on the exhaust systems of trucks and other vehicles to generate electrical power from the waste heat contained in the exhaust and to store that power in advanced power packs comprised of polymer-gel lithium ion batteries. Efficient inexpensive methods for production of the thermoelectric generator are also proposed. The technology that exists at LLNL, as well as that which exists at industrial partners, all have high technology readiness level (TRL). Work is needed for integration and deployment.

25 ENERGY STORAGE↗

Advanced Engine/Aftertreatment System R&D

Navistar and ORNL established this CRADA to develop diesel engine aftertreatment configurations and control strategies that could meet emissions regulations while maintaining or improving vehicle efficiency. The early years of the project focused on reducing the fuel penalty associated with lean NOx trap (LNT, also known as NOx adsorber catalyst) regeneration and desulfation. While Navistar pursued engine-based (in-cylinder) approaches to LNT regeneration, complementary experiments at ORNL focused on in-exhaust fuel injection. ORNL developed a PC-based controller for transient electronic control of EGR valve position, intake throttle position, and actuation of fuel injectors in the exhaust system of a Navistar engine installed at Oak Ridge. Aftertreatment systems consisting of different diesel oxidation catalysts (DOCs) in conjunction with a diesel particle filter and LNT were evaluated under quasi-steady-state conditions. Hydrocarbon (HC) species were measured at multiple locations in the exhaust system with Gas chromatograph mass spectrometry (GC-MS) and Fourier transform infrared (FTIR) spectroscopy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CRADA Final Report for CRADA Number ORNL00-0605: Advanced Engine/Aftertreatment System R&D

Navistar and ORNL established this CRADA to develop diesel engine aftertreatment configurations and control strategies that could meet emissions regulations while maintaining or improving vehicle efficiency. The early years of the project focused on reducing the fuel penalty associated with lean NOx trap (LNT), also known as NOx adsorber catalyst regeneration and desulfation. While Navistar pursued engine-based (in-cylinder) approaches to LNT regeneration, complementary experiments at ORNL focused on in-exhaust fuel injection. ORNL developed a PC-based controller for transient electronic control of EGR valve position, intake throttle position, and actuation of fuel injectors in the exhaust system of a Navistar engine installed at Oak Ridge. Aftertreatment systems consisting of different diesel oxidation catalysts (DOCs) in conjunction with a diesel particle filter and LNT were evaluated under quasi-steady-state conditions. Hydrocarbon (HC) species were measured at multiple locations in the exhaust system with Gas chromatograph mass spectrometry (GC-MS) and Fourier transform infrared (FTIR) spectroscopy. Under full-load, rated speed conditions, injection of fuel upstream of the DOC reduced the fuel penalty for a given level of NOx reduction by 10-20%. GC-MS showed that fuel compounds were 'cracked' into smaller hydrocarbon species over the DOC, particularly light alkenes. GC-MS analysis of HC species entering and exiting the LNT showed high utilization of light alkenes, followed by mono-aromatics; branched alkanes passed through the LNT largely unreacted. Follow-on experiments at a 'road load' condition were conducted, revealing that the NOx reduction was better without the DOC at lower temperatures. The improved performance was attributed to the large swings in the NOx adsorber core temperature. Split-injection experiments were conducted with ultra-low sulfur diesel fuel and three pure HC compounds: 1-pentene, toluene, and iso-octane. The pure compound experiments confirmed the previous results regarding hydrocarbon reactivity: 1-pentene was the most efficient LNT reductant, followed by toluene. Injection location had minimal impact on the reactivity of these two compounds. Iso-octane was an ineffective LNT reductant, requiring high doses (resulting in high HC emissions) to achieve reasonable NOx conversions. Diesel fuel reactivity was sensitive to injection location, with the best performance achieved through fuel injection downstream of the DOC. This configuration generated large LNT temperature excursions, which probably improved the efficiency of the NOx storage/reduction process, but also resulted in very high HC emissions. The ORNL team demonstrated an LNT desulfation under 'road load' conditions using throttling, EGR, and in-pipe injection of diesel fuel. Flow reactor characterization of core samples cut from the front and rear of the engine-aged LNT revealed complex spatially dependent degradation mechanisms. The front of the catalyst contained residual sulfates, which impacted NOx storage and conversion efficiencies at high temperatures. The rear of the catalyst showed significant sintering of the washcoat and precious metal particles, resulting in lower NOx conversion efficiencies at low temperatures. Further flow reactor characterization of engine-aged LNT core samples established that low temperature performance was limited by slow release and reduction of stored NOx during regeneration. Carbon monoxide was only effective at regenerating the LNT at temperatures above 200 C; propene was unreactive even at 250 C. Low temperature operation also resulted in unselective NOx reduction, resulting in high emissions of both N{sub 2}O and NH{sub 3}. During the latter years of the CRADA, the focus was shifted from LNTs to other aftertreatment devices. Two years of the CRADA were spent developing detailed ammonia SCR device models with sufficient accuracy and computational efficiency to be used in development of model-based ammonia injection control algorithms.ORNL, working closely with partners at Navistar and Mi

33 ADVANCED PROPULSION SYSTEMS↗

Pulse Detonation Engines for High Speed Flight

Revolutionary concepts in propulsion are required in order to achieve high-speed cruise capability in the atmosphere and for low cost reliable systems for earth to orbit missions. One of the advanced concepts under study is the air-breathing pulse detonation engine. Additional work remains in order to establish the role and performance of a PDE in flight applications, either as a stand-alone device or as part of a combined cycle system. In this paper, we shall offer a few remarks on some of these remaining issues, i.e., combined cycle systems, nozzles and exhaust systems and thrust per unit frontal area limitations. Currently, an intensive experimental and numerical effort is underway in order to quantify the propulsion performance characteristics of this device. In this paper, we shall highlight our recent efforts to elucidate the propulsion potential of pulse detonation engines and their possible application to high-speed or hypersonic systems.

Povinelli, Louis A.↗

Electrically heated DPF start-up strategy

An exhaust system that processes exhaust generated by an engine has a diesel particulate filter (DPF) that is disposed downstream of the engine and that filters particulates in the exhaust. An electrical heater is disposed upstream of the DPF and selectively heats the exhaust to initiate combustion of the particulates. Heat generated by combustion of particulates in the heater induces combustion of particulates within the DPF. A control module selectively enables current flow to the electrical heater for an initial period of a DPF regeneration cycle, and limits exhaust flow while the electrical heater is heating to a predetermined soot combustion temperature.

42 ENGINEERING↗

Electrical diesel particulate filter (DPF) regeneration

An exhaust system that processes exhaust generated by an engine includes a diesel particulate filter (DPF) that is disposed downstream of the engine and that filters particulates from the exhaust. An electrical heater is disposed upstream of the DPF and selectively heats the exhaust to initiate combustion of the particulates within the exhaust as it passes therethrough. Heat generated by combustion of the particulates induces combustion of particulates within the DPF.

42 ENGINEERING↗

Diesel particulate filter (DPF) regeneration by electrical heating of resistive coatings

An exhaust system that processes exhaust generated by an engine includes a diesel particulate filter (DPF) that is disposed downstream of the engine and that filters particulates from the exhaust. An electrical heater is integrally formed in an upstream end of the DPF and selectively heats the exhaust to initiate combustion of the particulates within the exhaust as it passes therethrough. Heat generated by combustion of the particulates induces combustion of particulates within the DPF.

42 ENGINEERING↗

WIPP Safety Significant Confinement Ventilation System (SSCVS) HEPA Filtration System - 20165

Construction and major equipment fabrication are underway for a new ventilation exhaust system at the Waste Isolation Pilot Plant (WIPP). The new system will provide continuous High Efficiency Particulate Air (HEPA) filtration of the exhaust from the WIPP underground while meeting the ventilation demands for expanded waste emplacement and mining operations over the next 40 years. The integrated system design provides for reducing the salt, clay and diesel particulates from the exhaust airflow from the mine, prior to full filtration using Nuclear Safety Significant HEPA filters. The SSCVS design and equipment provides for continuous HEPA filtration over a wide range of operating and environmental conditions. The new exhaust system connects to the existing underground exhaust shaft, and the exhaust air flows from the underground through Salt Reduction Units (SRUs) to protect the final filter banks from excessive moisture and rapid salt/dust buildup. Each of the six (6) SRUs consists of a demister to remove entrained moisture, a dry salt remover unit to filter approximately 90% of the entrained salt/dust, and an automated water treatment system to periodically clean the demisters and to remove salt from the SRU filters. At the maximum expected exhaust flowrate of 540,000 Cubic Feet per Minute (CFM) / 255 Cubic Meters per Second (m{sup 3}/s), five (5) salt removal units will be in operation with one unit in standby or maintenance. An in-line variable frequency drive booster fan will offset pressure losses through each SRU and reduce the relative humidity of the air exiting the SRUs. In the event of a high radiation alarm from the underground Continuous Air Monitors (CAMs), the SRUs will be automatically bypassed, which places the SRS and building outside of the Safety Significant confinement boundary. From the SRUs, the exhaust is directed to the HEPA filter banks located in the New Filter Building. The exhaust system is designed to provide continuous HEPA filtration prior to release to the exhaust stack. There are 22 HEPA filter banks rated at 27,000 CFM / 12.75 m{sup 3}/s each. Each filter bank has two stages of pre-filters and two stages of HEPA filters. The filtered air from each of the 22 filter banks discharges into a common concrete plenum, which is maintained under a negative pressure by the main exhaust fans. Six 1,000 HP variable frequency drive exhaust fans are provided on the south side of the plenum. At the maximum expected exhaust flow of 540,000 CFM, four exhaust fans and twenty filter banks will be in operation. The fans discharge vertically to a separate concrete exhaust plenum. The filtered exhaust is routed from the exhaust plenum to a 125-foot-tall exhaust stack via a 13-foot diameter duct. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Static and transient performance of YF-102 engine with up to 14 percent core airbleed for the quiet short-haul research aircraft

An outdoor static test stand was used to measure the steady-state and transient performance of the YF-102 turbofan engine with core airbleed. The test configuration included a bellmouth inlet and a confluent-flow exhaust system similar in size to the quiet short-haul research aircraft (QSRA) exhaust system. For the steady-state tests, the engine operated satisfactorily with core bleed up to 14 percent of the core inlet flow. For the transient tests the engine accelerated and decelerated satisfactorily with no core bleed and with core bleed up to 11 percent of the core inlet flow (maximum tested). For some of the tests the core-bleed flow rate was scheduled to vary with fan discharge pressure, to simulate the QSRA bleed requirements. No stability, surge, stall, overtemperature, combustor flameout, or other operating problems were encountered in any of the tests. Steady-state and transient engine performance data are presented in graphs, and fuel-control trajectories for typical transient tests are shown.

Mcardle, J. G.↗

Potential Indoor Worker Exposure From Handling Area Leakage: Example Event Sequence Frequency Analysis

The U.S. Department of Energy (DOE) is currently considering design options for the facilities that will handle spent nuclear fuel and high-level radioactive waste at the potential nuclear waste repository at Yucca Mountain, Nevada. The license application must demonstrate compliance with the performance objectives of 10 CFR Part 63, which include occupational dose limits from 10 CFR Part 20. If DOE submits a license application under 10 CFR Part 63, the U.S. Nuclear Regulatory Commission (NRC) will conduct a risk-informed, performance-based review of the DOE license application and its preclosure safety analysis, in which in-depth technical evaluations are focused on technical areas that are significant to preclosure safety and risk. As part of pre-licensing activities, the Center for Nuclear Waste Regulatory Analyses (CNWRA) developed the Preclosure Safety Analysis Tool software to aid in the regulatory review of a DOE license application and support any independent confirmatory assessments that may be needed. Recent DOE information indicates a primarily canister-based handling approach that includes the wet transfer of individual assemblies where Heating, Ventilation, and Air Conditioning (HVAC) systems may be relied on to provide confinement and limit the spread of any airborne radioactive material from handling operations. Workers may be involved in manual and remote operations in handling transportation casks, canisters, waste packages, or bare spent nuclear fuel assemblies inside facility buildings. As part of routine operations within these facilities, radioactive material may potentially become airborne if canisters are opened or bare fuel assemblies are handled. Leakage of contaminated air from the handling area into adjacent occupied areas, therefore, represents a potential radiological exposure pathway for indoor workers. The objective of this paper is to demonstrate modeling capabilities that can be used by the regulator to estimate frequencies of potential event sequences. A hypothetical case is presented for failure of the HVAC exhaust system to provide confinement for contaminated air from otherwise normal operations. This paper presents an example calculation of frequencies for a potential event sequence involving HVAC system failure during otherwise routine wet transfer operations of spent nuclear fuel assemblies from an open container. For the simplified HVAC exhaust system model, the calculation indicated that the potential event sequence may or may not be a Category 1 event sequence, in light of current uncertainties (e.g., final HVAC system design and duration of facility operations). Categorization of potential event sequences is important because different regulatory requirements and performance objectives are specified based on the categorization of event sequences. A companion paper presents a dose calculation methodology and example calculations of indoor worker consequences for the posed example event sequence. Together, the two companion papers demonstrate capabilities for performing confirmatory calculations of frequency and consequence, which may assist the assessment of worker safety during a risk-informed regulatory review of a potential DOE license application.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimental aerodynamic and acoustic model testing of the Variable Cycle Engine (VCE) testbed coannular exhaust nozzle system: Comprehensive data report

The component detail design drawings of the one sixth scale model of the variable cycle engine testbed demonstrator exhaust syatem tested are presented. Also provided are the basic acoustic and aerodynamic data acquired during the experimental model tests. The model drawings, an index to the acoustic data, an index to the aerodynamic data, tabulated and graphical acoustic data, and the tabulated aerodynamic data and graphs are discussed.

Nelson, D. P.↗