Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ESS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Reserve Model of Energy Storage in Day-ahead Joint Energy and Reserve Markets: A Stochastic UC Solution

With many favorable advantages including fast response ability in particular, utility-level energy storage systems (ESS) are being integrated into energy and reserve markets to help mitigate uncertain renewable resources and fluctuant demands. This paper discusses a stochastic unit commitment (UC) model to explore capabilities of ESSs in providing valuable grid services by simultaneously joining energy and reserve markets. The proposed reserve model of ESSs presents the following features: (i) two constraints are proposed to formulate ESS’s reserve provision ability in each hour via six operation modes, namely increasing/reducing the level of charge, switching to discharge, increasing/reducing the level of discharge, switching to charge; (ii) as an energy-limited asset, constraints on ESS’s reserve deliverability across multiple hours is introduced to hold enough state of charge (SOC) headroom and floor room, guaranteeing that reserves cleared in individual hours are continuously deliverable over multiple successive hours without violating operation limits. Furthermore, a scenario-based UC model, which addresses uncertainties of renewables and demands, is adopted to evaluate reserves provided by ESSs and generators. To effectively solve the stochastic UC problem, the progressive hedging algorithm with heuristic approaches is discussed. A 6-bus system and a modified IEEE 118-bus system are used to illustrate effectiveness of the proposed approaches.

25 ENERGY STORAGE↗

Harnessing Redox-Active Molecules in Alkylammonium Halide-Based Eutectic Solvents for Redox Flow Batteries

Redox flow batteries (RFBs) are promising for large-scale energy storage, however, advancements in performance and cost-effectiveness are critical factors for adoption. Here we report on alkylammonium halide based eutectic solvents (ESs) and found that a ESs comprising of diethylammonium chloride or bromide, in ethylene glycol demonstrated exceptional stability and a wide electrochemical stability window, making it a promising candidate for RFB applications. The electrochemical stability and redox behavior of the alkylammonium halide-based ESs are significantly influenced by hydrogen-bonding interactions, modulated by the alkyl chain length of the cation and the nature of the anion. A redox-active eutectic electrolyte containing 0.45 M methyl viologen dichloride (MV 2+ ) paired with acetylferrocene exhibited reversible redox behavior with a maximum open-circuit voltage of ∼1.34 V. The first redox couple, representing the viologen dication to radical cation transition, exhibited remarkable stability with consistent performance, achieving an energy efficiency near 70% at charge-discharge current densities of 10 mA cm −2 over 160 cycles with about 3% loss of the initial capacity. This study highlights the potential of alkylammonium halide DES systems for implementing eutectic-based RFB technologies in the future.

25 ENERGY STORAGE↗

Management of tritium European Spallation Source

The European Spallation Source (ESS) will produce tritium via spallation and activation processes during operational activities. Within the location of ESS facility in Lund, Sweden site it is mandatory to demonstrate that the management strategy of the produced tritium ensures the compliance with the country regulation criteria. The aim of this paper is to give an overview of the different aspects of the tritium management in ESS facility. Besides the design parameter study of the helium coolant purification system of the target the consequences of the tritium releasing into the environment were also analyzed. Calculations show that the annual release of tritium during the normal operations represents a small fraction from the estimated total dose. However, more refined calculations of migration of activated-groundwater should be performed for higher hydraulic conductivities, with the availability of the results on soil examinations. With the assumption of 100% release of tritium to the atmosphere during the occurring of the extreme accidents, it was found as well that the total dose complies with the constraint. (authors)

43 PARTICLE ACCELERATORS↗

Overview of Development and Deployment of Codes, Standards and Regulations Affecting Energy Storage System Safety in the United States

This report acquaints stakeholders and interested parties involved in the development and/or deployment of energy storage systems (ESS) with the subject of safety-related codes, standards and regulations (CSRs). It is hoped that users of this document gain a more in depth and uniform understanding of safety-related CSR development and deployment that can foster improved communications among all ESS stakeholders and the collaboration needed to realize more timely acceptance and approval of safe ESS technology through appropriate CSR.

Conover, David R.↗

Extraction-Scrub-Strip test results from the interim Salt Disposition Program Macrobatch 9 Tank 21H qualification samples

Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 9 for the Interim Salt Disposition Program (ISDP). The Salt Batch 9 characterization results were previously reported. An Extraction-Scrub-Strip (ESS) test was performed to determine cesium distribution ratios (D (Cs) ) and cesium concentration in the strip effluent and decontaminated salt solution (DSS) streams; this data will be used by Tank Farm Engineering to project a cesium decontamination factor (DF). This test used actual Tank 21H material, and a blend solvent prepared by SRNL that mimics the solvent composition currently being used at the Modular Caustic-Side Solvent Extraction Unit (MCU). The ESS test showed acceptable performance with an extraction D (Cs) value of 52.4. This value is consistent with results from previous salt batch ESS tests using similar solvent formulations. This compares well against the predicted value of 56.5 from a recently created D (Cs) model

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage Systems

The Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage Systems (PNNL-22010) was first issued in November 2012 as a first step toward providing a foundational basis for developing an initial standard for the uniform measurement and expression of energy storage system (ESS) performance. Based on experiences with the application and use of that document, and to include additional ESS applications and associated duty cycles, test procedures and performance metrics, a first revision of the November 2012 Protocol was issued in June 2014 (PNNL 22010 Rev. 1). As an update of the 2014 revision 1 to the Protocol, this document (the March 2016 revision 2 to the Protocol) is intended to supersede the June 2014 revision 1 to the Protocol and provide a more user-friendly yet more robust and comprehensive basis for measuring and expressing ESS performance.

25 ENERGY STORAGE↗

Extraction, scrub, and strip test results for the salt waste processing facility caustic side solvent extraction solvent example

An Extraction, Scrub, and Strip (ESS) test was performed on a sample of Salt Waste Processing Facility (SWPF) Caustic-Side Solvent Extraction (CSSX) solvent and salt simulant to determine cesium distribution ratios (D(Cs)), and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams; this data will be used by Parsons to help determine if the solvent is qualified for use at the SWPF. The ESS test showed acceptable performance of the solvent for extraction, scrub, and strip operations. The extraction D(Cs) measured 12.9, exceeding the required value of 8. This value is consistent with results from previous ESS tests using similar solvent formulations. Similarly, scrub and strip cesium distribution ratios fell within acceptable ranges.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Extraction, scrub, and strip test results for the solvent transfer to salt waste processing facility

The Savannah River National Laboratory (SRNL) prepared approximately 240 gallons of Caustic-Side Solvent Extraction (CSSX) solvent for use at the Salt Waste Processing Facility (SWPF). An Extraction, Scrub, and Strip (ESS) test was performed on a sample of the prepared solvent using a salt solution prepared by Parsons to determine cesium distribution ratios (D(Cs)), and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams. This data will be used by Parsons to help qualify the solvent for use at the SWPF. The ESS test showed acceptable performance of the solvent for extraction, scrub, and strip operations. The extraction D(Cs) measured 15.5, exceeding the required value of 8. This value is consistent with results from previous ESS tests using similar solvent formulations. Similarly, scrub and strip cesium distribution ratios fell within acceptable ranges.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Extraction, Scrub, and Strip Test Results for the Salt Waste Processing Facility Caustic Side Solvent Extraction Solvent Sample

An Extraction, Scrub, and Strip (ESS) test was performed on a sample of Salt Waste Processing Facility (SWPF) Caustic-Side Solvent Extraction (CSSX) solvent and salt simulant to determine cesium distribution ratios (D( Cs )), and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams; this data will be used by Parsons to help determine if the solvent is qualified for use at the SWPF. The ESS test showed acceptable performance of the solvent for extraction, scrub, and strip operations. The extraction D( Cs ) measured 12.5, exceeding the required value of 8. This value is consistent with results from previous ESS tests using similar solvent formulations. Similarly, scrub and strip cesium distribution ratios fell within acceptable ranges. This revision was created to correct an error. The previous revision used an incorrect set of temperature correction coefficients which resulted in slight deviations from the correct D( Cs ) results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Extraction, Scrub, and Strip Test Results for the Second Solvent Lot Qualification Sample for the Salt Waste Processing Facility

An Extraction, Scrub, and Strip (ESS) test was performed on the qualification sample from the second lot of Caustic-Side Solvent Extraction (CSSX) solvent for the Salt Waste Processing Facility (SWPF). Testing used simulated salt solution to determine cesium distribution ratios (D( Cs )), and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams. This data will be used by Parsons to help determine if the solvent is qualified for use at the SWPF. The ESS test showed acceptable performance of the solvent for extraction, scrub, and strip operations. The extraction D( Cs ) measured 14.4, exceeding the required value of 8. This value is consistent with results from previous ESS tests using similar solvent formulations. Similarly, scrub and strip cesium distribution ratios fell within acceptable ranges.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Energy Storage System Safety Documenting and Validating Compliance with Codes and Standards

Energy, environmental, and economic challenges are spurring more widespread consideration and use of energy storage systems (ESSs), which in turn are driving increased development of new ways to store energy electrochemically, mechanically, and thermally. These new methods necessitate an increased focus on ensuring that public health, safety, and welfare are not adversely affected—something that has been addressed for many years through codes, standards, and regulations (CSR5)1. CSRs provide requirements that establish a basis for determining if an ESS is safe, whether electrochemical, mechanical, or thermal and regardless of the range of ESS applications, energy capacities, physical sizes, location, or number installed at any given site. The key to achieving desired safety goals, as memorialized through CSRs, is through documenting and validating compliance with applicable CSRs. The process of documenting and validating compliance, which is a key component to the initial approval as well as continuing acceptance of an ESS installation, is generally called conformity assessment.

25 ENERGY STORAGE↗

Benefit Analysis of Energy Storage for Cordova Electric Cooperative

This report is a follow on to a previous study performed by Sandia National Labs and Alaska Center for Energy and Power which investigated the use of an energy storage system (ESS) providing spinning reserve within the Cordova Electric Cooperative (CEC) grid. The study provided the savings using the ESS as spinning reserve through reduced fossil fuel consumption and runtime on the diesel generators. In this report, the saving values are used from the previous study to determine the benefit-to-cost ratio for various ratings of ESS performing spinning reserve and quantifying other applications that are applicable to CEC.

25 ENERGY STORAGE↗

Extraction, Scrub, and Strip Test Results from The Interim Salt Disposition Program Macrobatch 11 Tank 21H Qualification Samples

Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 11 for the Interim Salt Disposition Program (ISDP). The Salt Batch 11 characterization results were previously reported. An Extraction, Scrub, and Strip (ESS) test was performed to determine cesium distribution ratios (D(Cs)) and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams; this data will be used by Tank Farm Engineering to project a cesium decontamination factor (DF). This test used actual Tank 21H material, and a sample of the Next Generation Solvent (NGS) Blend solvent currently being used at the Modular Caustic-Side Solvent Extraction Unit (MCU). The ESS test showed acceptable performance with an extraction D(Cs) value of 117. This value is consistent with results from previous salt batch ESS tests using similar solvent formulations. This cesium removal efficiency is better than the predicted value of 50.8 from a recently created D (Cs) model.

Peters, T.↗

Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage Systems

The Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage Systems (PNNL-22010) was first issued in November 2012 as a first step toward providing a foundational basis for developing an initial standard for the uniform measurement and expression of energy storage system (ESS) performance. Based on experiences with the application and use of that document, and to include additional ESS applications and associated duty cycles, test procedures and performance metrics, a first revision of the November 2012 Protocol was issued in June 2014 (PNNL-22010 Rev. 1). As an update of the 2014 revision 1 to the Protocol, this document (the March 2016 revision 2 to the Protocol) is intended to supersede the June 2014 revision 1 to the Protocol and provide a more user-friendly yet more robust and comprehensive basis for measuring and expressing ESS performance. This foreword1 provides general and specific details about what additions, revisions, and enhancements have been made to the June 2014 Protocol and the rationale for them in arriving at this March 2016 Protocol (PNNL-22010 Rev. 2).

25 ENERGY STORAGE↗

Smarter Grid Solutions | National Renewable Energy Laboratory: Active Management Integration: June 2015 - November 2016

This report presents the project results for the NREL INTEGRATE demonstration project: Active Network Management (ANM) Integration. Consistent with the INTEGRATE program's objective of increasing the grid's clean energy hosting capacity and providing grid services in a holistic manner, the project demonstrated the use of ANM to enable very high penetrations of solar PV and wind energy systems. Results obtained using a representative North American distribution system showed ANM's autonomous distributed control doubled the interconnected wind and solar systems by managing thermal and voltage constraints in real-time. These generators flexibly interconnected to the grid via ANM's end-to-end control architecture, and were managed and coordinated with other smart distributed energy resources (DER; e.g. EVs, battery ESS, controllable load) to unlock the grid's dynamic hosting capacity. As a smart grid application to standardize grid integration of diverse renewable generation sources, ANM provides the industry with a scalable, cost-effective alternative to traditional transmission and distribution (T&D) reinforcements. This project considered three use cases of the application of ANM: a Smart Home demonstration of ANM control of residential scale devices (PV, EV, and battery ESS); a Smart Campus demonstration of high penetration megawatt-scale DER (PV, EVs, battery ESS, and controllable load) behind a single point-of-common-coupling (PCC), and a Smart Distribution demonstration that combined prior use cases along with additional community/utility-scale DER at very high aggregate penetration levels. The Smart Distribution use case provided an integrated perspective of ANM across all distribution grid DER device scales (incorporating aggregated Smart Homes and the Smart Campus) in order to showcase how these devices can support smart grid services to manage DER related constraints in a safe and reliable manner; and likewise how ANM integrates with grid modernization initiatives. The ANM system was deployed in NREL's Energy Systems Integration Facility (ESIF), and project industry advisors attended an on-site demonstration and a set of workshops in order to review project outcomes and evaluate the relevance of ANM for increasing the grid hosting capacity. The outcomes of this effort include an assessment of opportunities for field deployment of ANM to address existing interconnection challenges, as well as consolidating project advisor suggestions for investment in ANM and potential future pilots for more advanced schemes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Extraction, Scrub, and Strip Test Results for the Salt Waste Processing Facility Caustic Side Solvent Extraction Solvent Sample

An Extraction, Scrub, and Strip (ESS) test was performed on a sample of Salt Waste Processing Facility (SWPF) Caustic-Side Solvent Extraction (CSSX) solvent and salt simulant to determine cesium distribution ratios (D (Cs) ), and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams; this data will be used by Parsons to help determine if the solvent is qualified for use at the SWPF. The ESS test showed acceptable performance of the solvent for extraction, scrub, and strip operations. The extraction D (Cs) measured 13.2, exceeding the required value of 8. This value is consistent with results from previous ESS tests using similar solvent formulations. Similarly, scrub and strip cesium distribution ratios fell within acceptable ranges

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Determination of Duty Cycles for Energy Storage Systems Providing Frequency Regulation and Peak Shaving Services with var Support

This report supplements the report, “Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage Systems,” PNNL-22010 Rev. 2 / SAND2016-3078 (2016 Protocol). It provides the background and documentation associated with the development of a duty cycle to be applied to an energy storage system (ESS) for any of the two applications (Frequency Regulation with VAr and Peak Shaving with VAr applications) for the purpose of measuring and expressing ESS performance in accordance with the 2016 Protocol for measuring and expressing ESS performance.

25 ENERGY STORAGE↗

Extraction, Scrub, and Strip Test Results for the Salt Waste Processing Facility Sample Tank 202

An Extraction, Scrub, and Strip (ESS) test was performed on a sample from Tank-202. The purpose of testing this sample is to determine if the solvent is displaying the correct extraction and stripping behavior with cesium. The ESS test showed acceptable performance of the solvent for extraction, scrub, and strip operations. The extraction D(Cs) measured 14.2, exceeding the required value of 8. This value is consistent with results from previous ESS tests using similar solvent formulations. Similarly, the strip cesium distribution ratios fell within acceptable ranges.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗