Pocket ECG electrode

A low noise electrode suited for sensing electrocardiograms when chronically and subcutaneously implanted in a free ranging subject is described. The electrode comprises a pocket shaped electrically conductive member with a single entrance adapted to receive body fluids. The exterior of the member and the entrance region is coated with electrical insulation so that the only electrolyte/electrode interface is within the member, remote from artifact-generating tissue. Cloth straps are bonded to the member to permit the electrode to be sutured to tissue and to provide electrical lead flexure relief.

Lund, G. F.↗

Subcutaneous electrode structure

A subcutaneous electrode structure suitable for a chronic implant and for taking a low noise electrocardiogram of an active animal, comprises a thin inflexible, smooth disc of stainless steel having a diameter as of 5 to 30 mm, which is sutured in place to the animal being monitored. The disc electrode includes a radially directed slot extending in from the periphery of the disc for approximately 1/3 of the diameter. Electrical connection is made to the disc by means of a flexible lead wire that extends longitudinally of the slot and is woven through apertures in the disc and held at the terminal end by means of a spot welded tab. Within the slot, an electrically insulative sleeve, such as silicone rubber, is placed over the wire. The wire with the sleeve mounted thereon is captured in the plane of the disc and within the slot by means of crimping tabs extending laterally of the slot and over the insulative wire. The marginal lip of the slot area is apertured and an electrically insulative potting material such as silicone rubber, is potted in place overlaying the wire slot region and through the apertures.

Lund, G. F.↗

Cabin fire simulator lavatory tests

All tests were conducted in the Douglas Cabin Fire Simulator under in-flight ventilation conditions. All tests were allowed to continue for a period of one hour. Data obtained during these tests included: heat flux and temperatures of the lavatory; cabin temperature variations; gas analyses for O2, CO2, CO, HF, HC1, and HCN; respiration and electrocardiogram data on instrumented animal subjects (rats) exposed in the cabin; and color motion pictures. All tests resulted in a survivable cabin condition; however, occupants of the cabin would have been subjected to noxious fumes.

Schutter, K. J.↗

Low-Noise Implantable Electrode

New implantable electrocardiogram electrode much less sensitive than previous designs to spurious biological potentials. Designed in novel "pocket" configuration, new electrode is intended as sensor for radiotelemetry of biological parameters in experiments on unrestrained subjects. Electrode is esentially squashed cylinder that admits body fluid into interior. Cylinder and electrical lead are made of stainless steel. Spot welding and crimping are used for assembly, rather than soldering.

Lund, G. F.↗

Portable medical status and treatment system

A portable medical status and treatment system is discussed. The vital signs monitor includes electrocardiogram, respiration, temperature, blood pressure, alarm, and power subsystems, which are described. A DC defibrillator module, a radio module, and their packaging are also described. These subsystems were evaluated and the results and recommendations are presented.

Source record↗

The diagnostic accuracy of exercise electrocardiography - A review

The cardiovascular 'stress test', and particularly the graded treadmill exercist test, has gained wide acceptance as a diagnostic aid in searching for ischemic heart disease and as a prognostic indicator for those with known coronary artery disease. Controversies still exist, however, in its use in mass screening and in interpreting equivocal tests. A review of the use and value of electrocardiographic exercise testing is presented. Topics such as its use in asymptomatic individuals, the adjuvant use of clinical examination, and the examination of ancillary treadmill parameters are presented. No attempt is made to detail the very significant contributions of radionuclide scanning. The positive exercise electrocardiogram in the asymptomatic subject is discussed and guidelines for clinical management are offered.

Johnson, R. L.↗

Development of engineering prototype of Life Support Module (LSM)

The development of an engineering prototype of a life support system is discussed. The module consists of an electrocardiogram, a defibrillator, a resuscitator, and an aspirator, as well as body temperature and blood pressure measuring instruments. A drug kit is included.

Source record↗

Physiological assessment of task underload

The ultimate goal of research efforts directed at underload, boredom, or complacency in high-technology work environments is to detect conditions or states of the operator that can be demonstrated to lead to performance degradation, and then to intervene in the environment to restore acceptable system performance. Physiological measures may provide indices of changes in condition or state of the operator that may be of value in high-technology work environments. The focus of the present study was on the use of physiological measures in the assessment of operator condition or state in a task underload scenario. A fault acknowledgement task characterized by simple repetitive responses with minimal novelty, complexity, and uncertainty was employed to place subjects in a task underload situation. Physiological measures (electrocardiogram (ECG), electroencephalogram (EEG), and pupil diameter) were monitored during task performance over a one-hour test session for 12 subjects. Each of the physiological measures exhibited changes over the test session indicative of decrements in subject arousal level. While high correlations between physiological measures were found across subjects, individual differences between subjects support the use of profiling techniques to establish baselines unique to each subject.

Comstock, J. Raymond, Jr.↗

Electroencephalographic monitoring of complex mental tasks

Outlined here is the development of neurophysiological procedures to monitor operators during the performance of cognitive tasks. Our approach included the use of electroencepalographic (EEG) and rheoencephalographic (REG) techniques to determine changes in cortical function associated with cognition in the operator's state. A two channel tetrapolar REG, a single channel forearm impedance plethysmograph, a Lead I electrocardiogram (ECG) and a 21 channel EEG were used to measure subject responses to various visual-motor cognitive tasks. Testing, analytical, and display procedures for EEG and REG monitoring were developed that extend the state of the art and provide a valuable tool for the study of cerebral circulatory and neural activity during cognition.

Guisado, Raul↗

Investigation into the common mode rejection ratio of the physiological signal conditioner circuit

The common mode rejection ratio (CMRR) of the single operational amplifier (op amp) differential amplifier and of the three operational amplifier differential amplifier was investigated. The three op amp differential amplifier circuit is used in the signal conditioner circuit which amplifies signals such as the electromyograph or electrocardiogram. The investigation confirmed via SPICE modeling what has been observed by others in the recent literature that the CMRR for the circuit can be maximized without precision resistor values or precisely matched op amps. This can be done if one resistor in the final stage can be adjusted either by a potentiometer or by laser trimming in the case of hybrid circuit fabrication.

Obrien, Edward M.↗

The rhesus measurement system: A new instrument for space research

The Rhesus Research Facility (RRF) is a research environment designed to study the effects of microgravity using rhesus primates as human surrogates. This experimental model allows investigators to study numerous aspects of microgravity exposure without compromising crew member activities. Currently, the RRF is slated for two missions to collect its data, the first mission is SLS-3, due to fly in late 1995. The RRF is a joint effort between the United States and France. The science and hardware portions of the project are being shared between the National Aeronautics and Space Administration (NASA) and France's Centre National D'Etudes Spatiales (CNES). The RRF is composed of many different subsystems in order to acquire data, provide life support, environmental enrichment, computer facilities and measurement capabilities for two rhesus primates aboard a nominal sixteen day mission. One of these subsystems is the Rhesus Measurement System (RMS). The RMS is designed to obtain in-flight physiological measurements from sensors interfaced with the subject. The RMS will acquire, preprocess, and transfer the physiologic data to the Flight Data System (FDS) for relay to the ground during flight. The measurements which will be taken by the RMS during the first flight will be respiration, measured at two different sites; electromyogram (EMG) at three different sites; electroencephalogram (EEG); electrocardiogram (ECG); and body temperature. These measurements taken by the RMS will assist the research team in meeting the science objectives of the RRF project.

Schonfeld, Julie E.↗

Changes in left ventricular function as determined by the multi-wire gamma camera at near presyncopal levels of lower body negative pressure

At presyncopal levels of lower body negative pressure (LBNP), we have frequently observed electrocardiographic responses that may be due to changes in cardiac position and/or shape, but could be indicative of altered myocardial function. To further investigate this, we evaluated cardiac function using a nuclear imaging technique in 21 healthy subjects (17 men and 4 women) after 30 minutes of supine rest and near the end of a presyncopal-limited LBNP exposure (LBNP averaged 65 plus or minus 3 mmHg at injection). Cardiac first pass images were obtained with a Multi-Wire Gamma Camera following an intravenous bolus injection of 30-50 millicurries of Tantalum-178. Manual blood pressures and electrocardiograms were obtained throughout the 3 minute graded LBNP protocol. Between rest and injection during LBNP, heart rate increased (P less than 0.01) from 67 plus or minus 3 beats per minute to 99 plus or minus beats per minute, systolic blood pressure decreased (P less than 0.01) from 110 plus or minus 3 mmHg to 107 plus or minus 3 mmHg and left ventricular ejection fraction (EF) decreased (P less than 0.01) from 0.57 plus or minus 0.02 to 0.48 plus or minus 0.02. During LBNP, ST segment depression of at least 0.5 mm occurred in 7 subjects. Subjects with ST depression had greater reductions (P = 0.05) in EF than subjects without ST depression (0.15 plus or minus 0.07 versus 0.005 plus or minus 0.03), but also tolerated greater levels (P less than 0.05) of negative pressure (88 plus or minus mmHg versus 69 plus or minus 5 mmHg). There was a significant relationship between presyncopal LBNP level and EF (R(exp 2) = 0.50, P less than 0.05). Our findings suggest there may be a decrease in systolic myocardial function at high levels of LBNP.

Pintner, R.↗

Intrapericardial denervation: Responses to water immersion in rhesus monkeys

Eleven anesthetized rhesus monkeys were used to study cardiovascular, renal, and endocrine alterations associated with 120 min of head-out water immersion. Five animals underwent complete intrapericardial denervation using the Randall technique, while the remaining six monkeys served as intact controls. Each animal was chronically instrumented with an electromagnetic flow probe on the ascending aorta, a strain gauge pressure transducer implanted in the apex of the left ventricle (LV), and electrocardiogram leads anchored to the chest wall and LV. During immersion, LV end-diastolic pressure, urine flow, glomerular filtration rate, sodium excretion, and circulating atrial natriuretic peptide (ANP) each increased (P less than 0.05) for intact and denervated monkeys. There were no alterations in free water clearance in either group during immersion, yet fractional excretion of free water increased (P less than 0.05) in the intact monkeys. Plasma renin activity (PRA) decreased (P less than 0.05) during immersion in intact monkeys but not the denervated animals. Plasma vasopressin (PVP) concentration decreased (P less than 0.05) during the first 30 min of immersion in both groups but was not distinguishable from control by 60 min of immersion in denervated monkeys. These data demonstrate that complete cardiac denervation does not block the rise in plasma ANP or prevent the natriuresis associated with head-out water immersion. The suppression of PVP during the first minutes of immersion after complete cardiac denervation suggests that extracardiac sensing mechanisms associated with the induced fluid shifts may be responsible for the findings. water immersion; natriuresis; vasopressin; eardiae denervation; monkey

McKeever, Kenneth H.↗

Intrapericardial Denervation: Responses to Water Immersion in Rhesus Monkeys

Eleven anesthetized rhesus monkeys were used to study cardiovascular, renal, and endocrine alterations associated with 120 min of head-out water immersion. Five animals underwent complete intrapericardial denervation using the Randall technique, while the remaining six monkeys served as intact controls. Each animal was chronically instrumented with an electromagnetic flow probe on the ascending aorta, a strain gauge pressure transducer implanted in the apex of the left ventricle (LV), and electrocardiogram leads anchored to the chest wall and LV. During immersion, LV end-diastolic pressure, urine flow, glomerular filtration rate, sodium excretion, and circulating atrial natriuretic peptide (ANP) each increased (P less than 0.05) for intact and denervated monkeys. There were no alterations in free water clearance in either group during immersion, yet fractional excretion of free water increased (P less than 0.05) in the intact monkeys. Plasma renin activity (PRA) decreased (P less than 0.05) during immersion in intact monkeys but not the denervated animals. Plasma vasopressin (PVP) concentration decreased (P less than 0.05) during the first 30 min of immersion in both groups but was not distinguishable from control by 60 min of immersion in denervated monkeys. These data demonstrate that complete cardiac denervation does not block the rise in plasma ANP or prevent the natriuresis associated with head-out water immersion. The suppression of PVP during the first minutes of immersion after complete cardiac denervation suggests that extracardiac sensing mechanisms associated with the induced fluid shifts may be responsible for the findings.

McKeever, Kenneth H.↗

A Head Start to a Healthy Heart

Cambridge Heart, Inc., has licensed the only U.S. Food and Drug Administration-cleared tool to identify those at risk for sudden cardiac death (SCD). The Microvolt T-Wave Alternans Test(TM) was invented by Dr. Richard J. Cohen, a professor at the Harvard-Massachusetts Institute of Technology (MIT) Division of Health Sciences and Technology, with developmental support and funding from NASA's Johnson Space Center and the National Space Biomedical Research Institute (NSBRI) in Houston, Texas. In 1993, MIT licensed the technology to Cambridge Heart, Inc., a start-up company that Dr. Cohen helped to establish. Cambridge Heart's non-invasive technology measures T-wave alternans, a change from one heartbeat to the next that is too minute to be detected by a standard electrocardiogram. Cardiac patients with such a change in heartbeat regulation are faced with a much greater risk of ventricular arrhythmia and SCD than those without it. The company's ability to measure electrical alternans on a microvolt level has been clinically proven to be just as accurate as - and in some studies, more accurate than - more costly and somewhat risky, invasive procedures, such as electrophysiological testing.

Source record↗

Slow Scan Telemedicine

Originally developed under contract for NASA by Ball Bros. Research Corporation for acquiring visual information from lunar and planetary spacecraft, system uses standard closed circuit camera connected to a device called a scan converter, which slows the stream of images to match an audio circuit, such as a telephone line. Transmitted to its destination, the image is reconverted by another scan converter and displayed on a monitor. In addition to assist scans, technique allows transmission of x-rays, nuclear scans, ultrasonic imagery, thermograms, electrocardiograms or live views of patient. Also allows conferencing and consultation among medical centers, general practitioners, specialists and disease control centers. Commercialized by Colorado Video, Inc., major employment is in business and industry for teleconferencing, cable TV news, transmission of scientific/engineering data, security, information retrieval, insurance claim adjustment, instructional programs, and remote viewing of advertising layouts, real estate, construction sites or products.

Source record↗

Emergency Medical Service

Lewis Research Center helped design the complex EMS Communication System, originating from space operated telemetry, including the telemetry link between ambulances and hospitals for advanced life support services. In emergency medical use telemetry links ambulances and hospitals for advanced life support services and allows transmission of physiological data -- an electrocardiogram from an ambulance to a hospital emergency room where a physician reads the telemetered message and prescribes emergency procedures to ambulance attendants.

Source record↗

Better Physician's 'Black Bags'

The "black bag" is outgrowth of astronaut monitoring technology from NASA's Johnson Space Center. Technically known as the portable medical status system, a highly advanced physician's "black bag" weighs less than 30 pounds, yet contains equipment for monitoring and recording vital signs, electrocardiograms, and electroencephalograms. Liquid crystal displays are used to present 15 digits of data simultaneously for long periods of time without excessive use of battery power. Single printed circuit card contains all circuitry required to measure and display vital signs such as heart and respiration rate, temperature, and blood pressure.

Source record↗