Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Dynamic range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Dark matter from axion strings with adaptive mesh refinement

Abstract Axions are hypothetical particles that may explain the observed dark matter density and the non-observation of a neutron electric dipole moment. An increasing number of axion laboratory searches are underway worldwide, but these efforts are made difficult by the fact that the axion mass is largely unconstrained. If the axion is generated after inflation there is a unique mass that gives rise to the observed dark matter abundance; due to nonlinearities and topological defects known as strings, computing this mass accurately has been a challenge for four decades. Recent works, making use of large static lattice simulations, have led to largely disparate predictions for the axion mass, spanning the range from 25 microelectronvolts to over 500 microelectronvolts. In this work we show that adaptive mesh refinement simulations are better suited for axion cosmology than the previously-used static lattice simulations because only the string cores require high spatial resolution. Using dedicated adaptive mesh refinement simulations we obtain an over three order of magnitude leap in dynamic range and provide evidence that axion strings radiate their energy with a scale-invariant spectrum, to within ~5% precision, leading to a mass prediction in the range (40,180) microelectronvolts.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Targeted Quantification of Protein Phosphorylation and Its Contributions towards Mathematical Modeling of Signaling Pathways

Post-translational modifications (PTMs) are key regulatory mechanisms that can control protein function. Of these, phosphorylation is the most common and widely studied. Because of its importance in regulating cell signaling, precise and accurate measurements of protein phosphorylation across wide dynamic ranges are crucial to understanding how signaling pathways function. Although immunological assays are commonly used to detect phosphoproteins, their lack of sensitivity, specificity, and selectivity often make them unreliable for quantitative measurements of complex biological samples. Recent advances in Mass Spectrometry (MS)-based targeted proteomics have made it a more useful approach than immunoassays for studying the dynamics of protein phosphorylation. Selected reaction monitoring (SRM)—also known as multiple reaction monitoring (MRM)—and parallel reaction monitoring (PRM) can quantify relative and absolute abundances of protein phosphorylation in multiplexed fashions targeting specific pathways. In addition, the refinement of these tools by enrichment and fractionation strategies has improved measurement of phosphorylation of low-abundance proteins. The quantitative data generated are particularly useful for building and parameterizing mathematical models of complex phospho-signaling pathways. Potentially, these models can provide a framework for linking analytical measurements of clinical samples to better diagnosis and treatment of disease.

mathematical modeling↗

Microengineering Pressure Sensor Active Layers for Improved Performance

Abstract Pressure sensors play an integral role in a wide range of applications, such as soft robotics and health monitoring. In order to meet this demand, many groups microengineer the active layer—the layer that deforms under pressure and dictates changes in the output signal—of capacitive, resistive/piezoresistive, piezoelectric, and triboelectric pressure sensors in order to improve sensor performance. Geometric microengineering of the active layer has been shown to improve performance parameters such as sensitivity, dynamic range, limit of detection, and response and relaxation times. There are a wide range of implemented designs, including microdomes, micropyramids, lines or microridges, papillae, microspheres, micropores, and microcylinders, each offering different advantages for a particular application. It is important to compare the techniques by which the microengineered active layers are designed and fabricated as they may provide additional insights on compatibility and sensing range limits. To evaluate each fabrication method, it is critical to take into account the active layer uniformity, ease of fabrication, shape and size versatility and tunability, and scalability of both the device and the fabrication process. By better understanding how microengineering techniques and design compares, pressure sensors can be targetedly designed and implemented.

Ruth, Sara Rachel Arussy↗

An imaging refractometer for density fluctuation measurements in high energy density plasmas

In this work, we report on a recently developed laser-probing diagnostic which allows direct measurements of ray-deflection angles in one axis, whilst retaining imaging capabilities in the other axis. This allows us to measure the spectrum of angular deflections from a laser beam which passes though a turbulent high-energy-density plasma. This spectrum contains information about the density fluctuations within the plasma, which deflect the probing laser over a range of angles. We create synthetic diagnostics using ray-tracing to compare this new diagnostic with standard shadowgraphy and schlieren imaging approaches, which demonstrates the enhanced sensitivity of this new diagnostic over standard techniques. We present experimental data from turbulence behind a reverse shock in a plasma and demonstrate that this technique can measure angular deflections between 0.06 and 34 mrad, corresponding to a dynamic range of over 500.

47 OTHER INSTRUMENTATION↗

Secondary Ion Mass Spectral Imaging of Metals and Alloys

Secondary Ion Mass Spectrometry (SIMS) is an outstanding technique for Mass Spectral Imaging (MSI) due to its notable advantages, including high sensitivity, selectivity, and high dynamic range. As a result, SIMS has been employed across many domains of science. In this review, we provide an in-depth overview of the fundamental principles underlying SIMS, followed by an account of the recent development of SIMS instruments. The review encompasses various applications of specific SIMS instruments, notably static SIMS with time-of-flight SIMS (ToF-SIMS) as a widely used platform and dynamic SIMS with Nano SIMS and large geometry SIMS as successful instruments. We particularly focus on SIMS utility in microanalysis and imaging of metals and alloys as materials of interest. Additionally, we discuss the challenges in big SIMS data analysis and give examples of machine leaning (ML) and Artificial Intelligence (AI) for effective MSI data analysis. Finally, we recommend the outlook of SIMS development. It is anticipated that in situ and operando SIMS has the potential to significantly enhance the investigation of metals and alloys by enabling real-time examinations of material surfaces and interfaces during dynamic transformations.

36 MATERIALS SCIENCE↗

Nanoscale inhomogeneity of charge density waves dynamics in La 2-x Sr x NiO 4

While stripe phases with broken rotational symmetry of charge density are known to emerge in doped strongly correlated perovskites, the dynamics and heterogeneity of spatial ordering remain elusive. Here we shed light on the temperature dependent lattice motion and the spatial nanoscale phase separation of charge density wave order in the archetypal striped phase in La 2-x Sr x NiO 4+y (LSNO) perovskite using X-ray photon correlation spectroscopy (XPCS) joint with scanning micro X-ray diffraction (SµXRD). While it is known that the CDW in 1/8 doped cuprates shows a remarkable stability we report the CDW motion dynamics by XPCS in nickelates with an anomalous quantum glass regime at low temperature, T < 65 K, and the expected thermal melting at higher temperature 65 < T < 120 K. The nanoscale CDW puddles with a shorter correlation length are more mobile than CDW puddles with a longer correlation length. The direct imaging of nanoscale spatial inhomogeneity of CDW by scanning micro X-ray diffraction (SµXRD) shows a nanoscale landscape of percolating short range dynamic CDW puddles competing with large quasi-static CDW puddles giving rise to a novel form of nanoscale phase separation of the incommensurate stripes order landscape.

36 MATERIALS SCIENCE↗

Detection and imaging of chemicals and hidden explosives using terahertz time-domain spectroscopy and deep learning

Detecting concealed chemicals and explosives remains a critical challenge in global security. Terahertz time-domain spectroscopy (THz-TDS) offers a promising non-invasive and stand-off detection technique owing to its ability to penetrate optically opaque materials without causing ionization damage. While many chemicals exhibit distinct spectral features in the terahertz range, conventional terahertz-based detection methods often struggle in real-world environments, where variations in sample geometry, thickness, and packaging can lead to inconsistent spectral responses. In this study, we present a chemical imaging system that integrates THz-TDS with deep learning to enable accurate pixel-level identification and classification of different explosives. Operating in reflection mode and enhanced with plasmonic nanoantenna arrays, our THz-TDS system achieves a peak dynamic range of 96 dB and a detection bandwidth of 4.5 THz, supporting practical, stand-off operation. By analyzing individual time-domain pulses with deep neural networks, the system exhibits strong resilience to environmental variations and sample inconsistencies. Blind testing across eight chemicals—including pharmaceutical excipients and explosive compounds—resulted in an average classification accuracy of 99.42% at the pixel level. Notably, the system maintained an average accuracy of 88.83% when detecting explosives concealed under opaque paper coverings, demonstrating its robust generalization capability. These results highlight the potential of combining advanced terahertz spectroscopy with neural networks for highly sensitive and specific chemical and explosive detection in diverse and operationally relevant scenarios.

Imaging and sensing↗

Electro-optic sampling of classical and quantum light

Full characterization of electric-field waveforms in amplitude and phase is achieved across the terahertz to visible spectral range through interaction with an optical pulse shorter than a half-cycle period via the Pockels (linear electro-optic) effect. This technique of electro-optic sampling has become an indispensable tool in various areas, including ultrafast pump-probe, time-domain and frequency-comb spectroscopies, quantum optics, high-harmonic generation, and attosecond science, and holds great promise for further advances. Not only does it enable spectroscopic measurements with record dynamic range and temporal resolution, along with massively parallel real-time spectral data acquisition, but its remarkable sensitivity also allows the detection of vacuum fluctuations, i.e., “zero-point motion” of electric fields, profoundly impacting our understanding of the fundamental laws of nature.

Benea-Chelmus, Ileana-Cristina (ORCID:000000024814↗

AstroPix: A pixelated HVCMOS sensor for space-based gamma-ray measurement

A next-generation medium-energy gamma-ray telescope targeting the MeV range would address open questions in astrophysics regarding how extreme conditions accelerate cosmic-ray particles, produce relativistic jet outflows, and more. One concept, AMEGO-X, relies upon the mission-enabling CMOS Monolithic Active Pixel Sensor silicon chip AstroPix. AstroPix is designed for space-based use, featuring low noise, low power consumption, and high scalability. Desired performance of the device include an energy resolution of 5 keV (or 10% FWHM) at 122 keV and a dynamic range per-pixel of 25–700 keV, enabled by the addition of a high-voltage bias to each pixel which supports a depletion depth of 500 μ m. This work reports on the status of the AstroPix development process with emphasis on the current version under test, version three (v3), and highlights of version two (v2). Version 3 achieves energy resolution of 10.4 ± 3.2% at 59.5 keV and 94 ± 6 μ m depletion in a low-resistivity test silicon substrate.

Astrophysics instrumentation↗

Spectrometer-free quantitative vapor sensing and classification via spatiotemporal imaging of porous silicon metasurfaces

Metasurfaces offer a compact platform for optical vapor sensing, but their practical deployment has been limited by weak evanescent light–matter interactions and reliance on spectrally resolved instrumentation. Here, we report porous silicon (pSi) metasurfaces for spectrometer-free quantitative detection of volatile organic compounds (VOCs) with strongly enhanced light–matter interaction. The engineered porosity increases sensitivity by >100× relative to non-porous dielectric metasurfaces, enabling limits of detection of 1.65 ppm for methanol and 9.1 ppm for ethanol across a broad dynamic range (<10 ppm to >103 ppm). Imaging-based readout provides a lightweight, spectrometer-free pathway for real-time quantitative sensing. Beyond quantitative detection, the mesoporous architecture introduces adsorption–desorption kinetics as an additional information channel. Analysis of the resulting spatiotemporal signatures enables kinetic fingerprinting without reliance on infrared spectral features or surface functionalization, and a lightweight machine-learning classifier differentiates acetone, methanol, ethanol, and isopropanol with 91.6% accuracy. These results establish porous metasurfaces as spatiotemporal sensing elements that couple quantitative vapor detection with kinetic fingerprinting through real-time dynamical responses, enabling low-cost, high-performance optical sensors.

Dash, Tomoshree [Clemson University]↗

Spectroscopic features of dissolved iodine in pristine and gamma-irradiated nitric acid solutions

While iodine speciation is important for a wide range of nuclear activities, understanding the mechanisms of the transformations of iodine between chemical forms and the sensitivity of these transitions to solution conditions and exposure to radiation remains an active area of research. This work curates spectroscopic data from several experimental techniques and establishes their sensitivity and limitations in detecting changes in iodine speciation in both neutral and acidic regimes. The techniques include Raman spectroscopy, Fourier Transform Infrared (FTIR) spectroscopy, 127 I NMR spectroscopy, and ultraviolet-visible (UV-Vis) spectroscopy. Analysis of these data indicates that these commonly accessible spectroscopies often have dynamic ranges of measurable concentrations that do not always overlap between all techniques. The experimental techniques are disparately sensitive to iodide (I - ), molecular iodine (I 2 ), iodate (IO 3 - ), and periodate (IO 4 - ) species. Raman, FTIR, and NMR spectra were subsequentially analyzed using two-dimensional correlation analyses to generate high-resolution autocorrelation spectra. Here, the use of these spectroscopies is then extended to tracking acidification-induced and gamma irradiation-induced transformations of dissolved sodium iodate in deionized water and concentrated nitric acid. Both dissolution into nitric acid and irradiation with a gamma source are demonstrated to perturb the iodine speciation promoting their assembly into molecular iodine (I 2 ) and/or triiodide (I 3 - ). While I 2 and I 3 - species are undetectable with FTIR spectroscopy and 127 I NMR spectroscopy, the species can be detected with UV-Vis spectroscopy, and in some instances, I 3 - can be detected with Raman spectroscopy in the low wavenumber region. Ultimately, the results of this work provide a path to designing optimal combinations of techniques to detect forms of iodine across a wide range of concentrations and conditions.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Small molecule biosensors

Biosensors for small molecules can be used in applications that range from metabolic engineering to orthogonal control of transcription. Biosensors are produced based on a ligand-binding domain (LBD) using a method that, in principle, can be applied for any target molecule. The LBD is fused to either a fluorescent protein or a transcriptional activator and is destabilized by mutation such that the fusion accumulates only in cells containing the target ligand. The power of this method is illustrated by developing biosensors for digoxin and progesterone. Addition of ligand to cells expressing a biosensor activates transcription in yeast, mammalian cells and plants, with a dynamic range of up to about 100-fold or more. The biosensors are used to improve the biotransformation of pregnenolone to progesterone in yeast and to regulate CRISPR activity in mammalian cells. This work provides a general methodology to develop biosensors for a broad range of molecules.

Mandell, Daniel J.↗

Linear Viscoelastic Properties of Putative Cyclic Polymers Synthesized by Reversible Radical Recombination Polymerization (R3P)

Linear viscoelastic properties in both melt and solution states are reported for a series of poly(3,6-dioxa-1,8-octanedithiol) (polyDODT) made by reversible radical recombination polymerization (R 3 P) under conditions designed to produce linear (LDODT), cyclic (RDODT) and linear-cyclic mixtures (LRDODT). PolyDODT is amorphous (T g < -50 °C) and highly flexible (entanglement molecular weight M e,lin ≈ 1850 g/mol for LDODT). PolyDODT’s low T g and low M e,lin enable characterization over a wide dynamic range and a wide range of dimensionless weight-average molecular weight Z w = M w /M e,lin . Measurements at temperatures from -57 °C to 100 °C provide up to 18 deades of reduced frequency, which is necessary to characterize RDODT melts with Z w from 23 to 300. The two highest molecular weight polymers in the present RDODT series have such high M w (406k and 556k g/mol) that mass spectrometry, NMR spectroscopy, and even chemical assays for chain ends are unable to rule out up to 2 mol% linear contaminant. By studying the samples in solution (using dilution to reduce Z w ) we could compare their dynamics with those of previously established high-purity polystyrene (PS) rings (limited to Z w ≤ 13.6). RDODT solutions with Z w < 15 (concentrations <5wt% for RDODT-406k and 556k) have dynamic moduli G^* that accord with LCCC-purified PS rings in terms of the frequency dependence (including the absence of a plateau), the progression of shapes of G* as a function of Z w , and the linear scaling of their zero-shear viscosity η0 with M w . The shape of G* as a function of Z w for solutions of RDODT-406k and -556k also accord with lower M w RDODT melts (which have ≤ 1.3mol% linear contaminant). Thus, measurement of the linear viscoelastic properties of appropriate concentrations of high M w (>200k g/mol) putative cyclic polymers, in which linear chains evade spectroscopic detection, may provide an alternative means (though not fully proven) of validation of sample purity. When Z w > 15 (including all seven RDODT melts and eight of their solutions), G* has a rubbery plateau. This suggests that the onset of entanglement-like behavior in rings requires 4-5-fold greater Z w than is required for linear chains. Further, the plateau moduli of RDODT samples are indistinguishable from G N o of the corresponding LDODT (melt or matched-concentration solutions). In entangled linear polymers, the observation that G N o is independent of Z w follows from limitations on lateral fluctuations due to neighboring chains becoming independent of position along a given chain. The present results for RDODT suggest that this holds for sufficiently long endless chains, too. While the RDODT have the same G N o as entangled LDODT, when Z w > 60 the terminal relaxation, if reached at all, of RDODT extends to orders of magnitude lower frequency than an entangled linear polymer of the same Z w . Consequently, the viscosity of RDODT with Z w > 60 increases with Z w much more strongly than the 3.4-power observed for entangled linear polymers. Lastly, these novel polymers, with disulfide-linked backbone and broad relaxation time distribution may prove important in relation to biodegradable elastomers and materials with exceptional low-frequency dissipation, extending at least 12 decades below the onset of the rubbery plateau.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Momentum-Space Observation of Optically Excited Nonthermal Electrons in Graphene with Persistent Pseudospin Polarization

The unique optical properties of graphene, with broadband absorption and ultrafast response, make it a critical component of optoelectronic and spintronic devices. Using time-resolved momentum microscopy with high data rate and high dynamic range, we report momentum-space measurements of electrons promoted to the graphene conduction band with visible light and their subsequent relaxation. Here, we observe a pronounced nonthermal distribution of nascent photoexcited electrons with lattice pseudospin polarization in remarkable agreement with results of simple tight-binding theory. By varying the excitation fluence, we vary the relative importance of electron-electron vs electron-phonon scattering in the relaxation of the initial distribution. Increasing the excitation fluence results in increased noncollinear electron-electron scattering and reduced pseudospin polarization, although up-scattered electrons retain a degree of polarization. These detailed momentum-resolved electron dynamics in graphene demonstrate the capabilities of high-performance time-resolved momentum microscopy in the study of 2D materials and can inform the design of graphene devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of Shadowgraphy and X-Ray Phase Contrast Methods for Characterizing a DT Ice Layer in an Inertial Confinement Fusion Target

Shadowgraphy and x-ray phase contrast (XPC) imaging are two techniques that are used for characterizing the deuterium-tritium ice layer in Inertial Confinement Fusion targets. Each technique has limitations that affect how accurately they can characterize small crystalline defects and measure the ice-thickness non-uniformities that may be only a few micrometers in height. The concern is that shadowgraphy may be overly sensitive to the shape and depth of defects in the surface and insufficiently sensitive to the shape of longer-wavelength roughness, while x-ray phase contrast may be too insensitive to defects in the ice surface. Multiple ice layers with different thicknesses (40 to 63 μm), thickness uniformities (peak-valley variations that range from <2- to 12 μm), and crystal defects were analyzed using shadowgraphy and x-ray phase contrast techniques. The results from each method agree when the ice layer is uniformly thick and the crystal lacks defects. That agreement worsens as the number of defects in the surface of the ice layer increases and the roughness that is determined from a shadowgram image of the target’s limb is greater than can be justified by the number of defects that are seen in the target’s front and rear surfaces. The XPC technique is considerably less sensitive to surface defects, in part due to the poorer dynamic range and image resolution compared to shadowgraphy. Localized regions of the ice layer that are thicker or thinner than the average thickness of the layer are reported by shadowgraphy to be smaller in height and footprint (by up to 30%) than by XPC. As a result, the two techniques report different ice layer thicknesses that can vary by up to 10%. Shadowgraphy results from two caustics that trace different paths through the target, and, in theory, image the same ice-vapor surface (but reflect from either the vapor or ice side of the interface) did not consistently characterize the size or shape of ice features to be the same magnitude. Here, the XPC technique provides the best assessment of low-mode (l < 7) roughness in the ice layer. Shadowgraphy results using the strongest caustic is best for detecting the presence of grooves in the ice, though not for quantifying the size of them. If multiple grooves are present it is best to discard and reform the ice layer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗