Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DyEr”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Performance Assessment for the E-Area Low-Level Radioactive Waste Disposal Facility at the Savannah River Site: Appendix I

As stated in Section 9.1.2.2, a final inventory of parent radionuclides is projected for every DU at the time of facility operational closure in 2065. These final closure inventories are upper-bound estimates wherein each DU is assumed to reach its activity capacity. Composition vectors based on existing DU inventories are employed to estimate the final compositions of all existing and future DUs. Specifically, (1) the existing DU compositions are assumed to remain constant; (2) future DUs are assigned averaged existing compositions based on appropriately averaged DUs. This information is detailed in Appendix H, Section H.7. In addition, the variability in composition among existing DUs is used to generate log-normal distributions for uncertainty quantification, which is detailed in Section I.1.1.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dissolution of a Can Carrier Pin in Concentrated Nitric Acid

H=Canyon will be dissolving Fast Critical Assembly (FCA) fuel from the Japan Atomic Energy Agency (JAEA). The FCA fuel will be dissolved in the electrolytic dissolver in a solution that is a 50 wt.% nitric acid (HNO 3 ), 0.5 g/l gadolinium (Gd), and 0.05 M potassium fluoride (KF). The nitric acid concentration is expected to decrease during the batch process from 10.3 to 7 M. The temperature of the nitric acid solution may be as low as 15 °C. The fuel can will be placed in the dissolver basket insert utilizing a reusable charging device. The charging device is a coated stainless-steel rod with a clevis design. The charging device employs a linchpin to secure the FCA fuel can as it is being charged into the H-canyon dissolver. Prior to beginning the electrolytic dissolution process, the pin will be dissolved, the fuel can will remain in the dissolver basket insert and the charging device will be removed. Currently the time necessary for complete dissolution of the pin is unknown and thus the timing of the removal of the charging device cannot be planned. This process is to be performed remotely and therefore complete dissolution of the pin will not be able to be visually determined. The pin will be made of a material that dissolves in the concentrated nitric acid solution in the dissolver. The facility desired to know the time that the pin would be dissolved so that the charging device for the FCA can could be removed from the dissolver. In particular, the pin dissolution time as a function of the nitric acid concentration and the temperature was desired. The facility would like to ensure that the solution environment was such that the charging device could be removed within an operational shift (8-12 hours).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

2022 LaserNetUS Users' Meeting

Organized and funded in 2018 through the US Department of Energy, Office of Fusion Energy Sciences (FES), LaserNetUS was created to provide vastly improved access to unique lasers for researchers. LaserNetUS is a network of ten high-power laser facilities, both academic and national laboratories, across the United States and Canada. These labs operate many of the premier mid- to large-scale high-intensity laser facilities in the US and Canada that are designed to be used in pioneering experimental studies in high energy density plasma and high field optical science. The network’s principal goal is to provide access to these state-of-the-art laser facilities to a broad range of researchers in the US and abroad. In its over four years of operation, LaserNetUS has awarded beamtime for over 60 user experiments to researchers from 25 different institutions. Over 400 user scientists, many of whom are students and post-docs, have participated in experiments at LaserNetUS facilities so far. The network now has over 1250 members. The LaserNetUS institutions are Colorado State University, Lawrence Berkeley National Lab, Lawrence Livermore National Lab, SLAC National Lab, The Ohio State University, University of Michigan, University of Nebraska-Lincoln, Institut National de la Recherche Scientifique, University of Rochester, and University of Texas at Austin. LaserNetUS hosted its first in-person Annual Users’ Meeting at Colorado State University in Fort Collins, CO, Aug 16-18, 2022. The meeting had 158 attendees, including 39 sponsored students and post-docs whose attendance and travel to the meeting were covered by DOE funds. Attendees included the 2018 Nobel Laureate in Physics, Donna Strickland. The program consisted of 5 plenary talks and several invited and contributed talks, a user community forum, a poster session, and built-in time for networking. The event focused on students and early career professionals. The poster session was held in combination with a reception to facilitate discussions and maximize interactions between the participants. The 39 sponsored students each presented a poster at the poster session, giving them valuable practice in sharing their research with others in the field. Many students and postdocs also gave talks during the main programming. Lunch and coffee breaks were provided for attendees for the duration of the conference on CSU’s campus. This allowed for networking among all participants. The building used to host the conference also had plenty of seating outside the auditorium, which was conducive to smaller one-on-one meetings and discussions between participants. There was also a lab tour of CSU’s Advanced Beam Laboratory. The day before and after the conference also included satellite meetings for the lab PIs and the Scientific Advisory Board. DOE support was used for rental of the auditorium and supporting rooms, student participation, 50% of the food costs, and transportation to the Advanced Beam Lab.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Verification Testing of OLI Systems Mixed Solvent Electrolyte Model for the Na-K-Mg-Ca-H-Cl-SO 4 -OH-HCO 3 -CO 3 -CO 2 -H 2 ) System to High Ionic Strength at 25°C

This technical report summarizes model verification results and summary statistics for 41 evaporite mineral solubility cases evaluated by Savannah River National Laboratory using OLI Systems’ aqueous electrolyte thermodynamic modeling software. The 41 verification cases containing a total of 60 solubility curves comprise mineral solubility data from low to high ionic strength at 25°C for the eight-component system Na-K-Mg-Ca-H-Cl-SO 4 -OH-HCO 3 -CO 3 -CO 2 -H 2 O as reported by Harvie et al. (1984). Thermodynamic calculations were executed using OLI Systems’ Stream Analyzer computation module within the OLI Studio software platform (Ver. 11.0, Rev. 11.0.1.9). The Mixed Solvent Electrolyte (MSE) thermodynamic framework was chosen for this investigation because of its superiority in modeling high ionic-strength inorganic salt solutions and actinide redox chemistry and solubility, both of which are relevant to the geological repository conditions at the Waste Isolation Pilot Plant in Carlsbad, New Mexico. Mineral solubility data in various inorganic salt solutions were digitized and extracted from figures generated by Harvie et al. (1984). For each of the 60 solubility curves, a case-specific chemistry model and input file were generated in OLI Studio using OLI Stream Analyzer and the MSE (H 3 O + ion) public databank provided by OLI Systems. Model simulation results were exported to Microsoft Excel to calculate summary statistics and to generate graphs comparing the OLI model predictions to the solubility data. Summary statistics include residuals (model – data) and concordance (accuracy × precision, where precision is indicated by the Pearson correlation coefficient and accuracy accounts for bias and scale differential). Private databanks were not developed, and activity coefficient model regressions were not performed to improve OLI model fits to the data. Of the 41 model verification plots, 83% have a mean of the percent residuals less than or equal to 25%. Similarly, 75% display a concordance greater than or equal to 0.75. Only seven of the 41 verification plots fail to show good agreement between the model and data. Of these seven, three are relevant to the WIPP repository because they involve the Mg-OH-Cl-SO 4 -CO 3 aqueous system. The remaining four address salt solubilities at the pH extremes (strong acid and strong base). It should be noted that in two of the three Mg-OH-Cl-SO 4 -CO 3 system cases, the regressed Harvie et al. (1984) solubility curve also deviated from the data. Lack of agreement between the OLI model-predicted solubility curves and the data is attributable to one or more of the following: specific solid species are not included in the OLI MSE databank; there is significant variation among the different solubility datasets chosen by Harvie et al. (1984); the OLI MSE model’s thermodynamic parameters were determined using different solubility datasets; and the activity coefficient parameters for certain relevant ion-ion and ion-molecule pairs have not been optimized via data regression. Two recommendations for future work are to (1) evaluate solubility data for the Mg-OH-Cl-SO 4 -CO 3 system at high ionic strength and, if necessary, develop a private OLI MSE database that includes missing species and, where necessary, regressed standard state properties and interaction parameters; (2) perform similar verification testing of the OLI model for actinide solubility data.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Deploying a Publicly Available and Living National Oil and Gas Well Geodatabase: CO2-Locate: A Dynamic Database & Tool

Emission mitigation and safe geologic carbon storage require an understanding of local wellbore infrastructure, yet well data are siloed across many entities. Addressing this challenge, the National Energy Technology Laboratory published CO2-Locate, an integrated and dynamic national wellbore geodatabase. CO2-Locate offers up to date well data spanning more than 40 federal, state, and tribal entities, as well as spatially summarized insights designed to support commercial, regulatory, and research communities as they strive to curb climate change through a national energy transition.

Pfander, Isabelle↗

Evaluating the Nation's Pipeline Infrastructure with NETL's Advanced Infrastructure Integrity Model (AIIM)

This poster is a part of BIL-EDX4CCS Task 36: Advanced Infrastructure Integrity Modeling to Evaluate Existing Energy Infrastructure Reusability and Risk, the goal of which is to produce a smart tool that will assess existing energy infrastructure reusability and risk using the Advanced Infrastructure Integrity Model (AIIM). This model forecasts lifespan and potential risk using a multitude of factors such as incidents reports, structural characteristics, and the surrounding environment. The project aims to provide scientific insights for a better understanding of carbon storage (CS), potential to support CS stakeholder needs, national decarbonization, and mitigating climate change. AIIM will utilize an energy infrastructure database as its input, developed by acquiring publicly available data as well as NETL derived products. These resources include incidents, geohazards, and infrastructure variables. Soil data in the form of rasters and pipeline incident reports were processed and a script was developed to count the number of times features such as roads, railroads, and rivers intersected with pipeline segments which were then converted to points. Distance to oil and natural gas wells, petroleum ports, intermodal freight facilities, and geologic structures were also calculated. After data preparation and quality control was completed, the data was integrated into the pipeline points. Once models are complete, a smart tool will be created in the form of an online dashboard.

Malay, Caleb↗

CO2-Locate: A Living National Well Database

This is a presentation on NETL's CO2-Locate Database, an integrated resource of standardized public well records focusing on oil and gas well data acquired from federal, state, and tribal entities. This presentation covers updates on the resource, the integration method, and how CO2-Locate is being used as a baseline to support cross-cutting infrastructure projects.

Romeo, Lucy↗

The Integration and Mapping of an Open-Source National Well Resource to Inform Geologic Carbon Storage Site Selection and Risk Prevention: The CO2-Locate Database

Geologic carbon storage (GCS) offers a way to capture and permanently store CO₂ from fossil fuel operations in underground geologic structures, aiding in the transition to a carbon-neutral energy economy. However, CO₂ injection sites can experience gas leakage through existing wells that penetrate storage reservoirs, making knowledge of well locations and characteristics crucial for permitting, infrastructure reusability, and risk assessment in GCS. Currently, public wellbore data from state, federal, and tribal entities are inconsistent and fragmented, with gaps and redundancies. To address this, the National Energy Technology Laboratory (NETL) developed CO2-Locate, an open-source, geospatial database and online application. CO2-Locate integrates over 50 data sources from federal, state, and tribal entities, creating a standardized national well database. Funded by the Bipartisan Infrastructure Law, the database is publicly available through the Energy Data eXchange (EDX) and viewable via the CO2-Locate web mapping application. This tool allows users to query, filter, and visualize well data to support GCS planning, permitting, and risk assessments. This presentation covers the methods used to create CO2-Locate, including data acquisition, processing, attribute mapping, and integration, much of which is automated for future updates. The web mapping application and its role in GCS site selection will also be discussed.

Tetteh, Daniel A.↗

Organic Evaporation, Oxidation, and Hydrolysis Testing in Support of Hanford Sample-and-Send

The Hanford site has approximately 54 to 56 million gallons of radioactive mixed waste stored in 156 unretrieved underground storage tanks. The Hanford Waste Treatment and Immobilization Plant (WTP) is being built to treat and immobilize the tank waste. The baseline method for immobilization of Low Activity Waste (LAW) through the WTP is vitrification, but additional immobilization capacity is needed to supplement the initial LAW melters. An alternative cementitious waste form is being investigated for that future immobilization method. However, one impediment to a cementitious waste form is the presence of Land Disposal Restricted (LDR) organic chemicals in tank waste, which are regulated on a concentration based standard in the final waste form. Hence, if the quantity of organics in LAW is high enough, they must be destroyed or removed to make a waste form compatible with disposal in a mixed low level waste landfill. This work evaluates potential avenues for treatment of LDR organics to eliminate the impediment and permit possible use of a cementitious waste form. Vacuum evaporation testing to remove LDR organics consisted of preparing a non-radioactive LAW simulant, spiking that simulant with organic chemicals, and evaporating the mixture via differential distillation. The apparatus was a laboratory-scale vacuum evaporator operated at 60 ±5 torr absolute (vacuum evaporation). The LAW simulant represented the liquid expected to be retrieved from the Hanford tank farms at approximately 4.0 M [Na+] total sodium ion concentration. The concentration of the organic chemicals added was significantly higher than typically found in the tank waste samples since the higher levels were necessary to assist in analytical measurement and tracking of the spiked species.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CO2-Locate: A Dynamic Database and Tool for Accessing National Oil and Gas Well Data to Inform Carbon Storage Projects

The CO2-Locate Database is a growing compilation of publicly available wellbore resources that have been merged based on common attributes across data sources with an attribute schema developed to be consistent across disparate resources, reduce data gaps, and eliminate record redundancy. The first version of CO2-Locate has been published to Energy Data eXchange (EDX) and includes the integrated public wells dataset as well as additional geospatial summary layers of key wellbore characteristics to protect proprietary resources. Additionally, the CO2-Locate database has been deployed into a web application, enabling easy access, data filtering capabilities, and visualization of U.S. wellbore infrastructure by stakeholders to inform injection site selection and risk assessments.

Dyer, Alec S. [NETL Site Support Contractor, Natio↗

Effect of Anoxic Iron Corrosion on WIPP Brine Geochemistry FY23 Final Report (U)

A 280-day study was completed to evaluate the effect of zero-valent iron (Fe 0 ) on the Waste Isolation Pilot Plant (WIPP) brine geochemistry under anticipated reducing conditions. Hydrogen (H 2 ) gas is expected to be present in the repository after closure due to the anoxic corrosion of a vast quantity of iron contained in the waste forms disposed at WIPP; therefore, a background argon atmosphere containing H 2 was chosen for this study. WIPP groundwater brine pH and E h will impact the mobility and fate of plutonium within the repository. Modeling and laboratory results for Castile WIPP brine indicate that equilibrium E h values relative to the standard hydrogen electrode (SHE) are 40 mV more reducing (i.e., more negative) than those for Salado WIPP brine (-480 mV vs. -440 mV, respectively) because of the higher pH of the Castile brine (pH 9.3 for Castile vs. pH 8.8 for Salado). The E h and pH data were corrected for the effects of high ionic strength. The experimental results for both brines are consistent with thermodynamic predictions using OLI Systems' Mixed Solvent Electrolyte chemical equilibrium model. The measured and corrected pH and E h data from this study are provided in Table ES-1 and Table ES-2, respectively.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of Tank 15H Sample in Support of Preliminary Cease Waste Removal and Closure Mode Determination

The Savannah River National Laboratory (SRNL) was requested by Savannah River Mission Completion (SRMC) to provide sample preparation and analysis of Tank 15H characterization samples. These samples follow an interest in exploring avenues to condense the extensive sampling of the Tank Closure process. One such pathway would be to collect a sample during an earlier waste removal campaign for analysis to determine comparability to the later residual tank inventory determined through Residual Material sampling and characterization prior to grouting. Six Tank 15H samples (HTF-15-24-9, HTF- HTF-15-24-10, HTF-15-24-11, HTF-15-24-12, HTF15-24-13, and HTF-15-24-14) were delivered to SRNL in May of 2024. These six Tank 15H samples were taken as close as possible to the solids layer of the Tank 15H. These six Tank 15H samples were combined to form one composite sample for characterization due to the lack of sufficient solids fraction.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of Anoxic Iron Corrosion on WIPP Brine Geochemistry FY23 Final Report (U)

A 280-day study was completed to evaluate the effect of zero-valent iron (Fe 0 ) on the Waste Isolation Pilot Plant (WIPP) brine geochemistry under anticipated reducing conditions. Hydrogen (H 2 ) gas is expected to be present in the repository after closure due to the anoxic corrosion of a vast quantity of iron contained in the waste forms disposed at WIPP; therefore, a background argon atmosphere containing H 2 was chosen for this study. WIPP groundwater brine pH and E h will impact the mobility and fate of plutonium within the repository. Modeling and laboratory results for Castile WIPP brine indicate that equilibrium fa values relative to the standard hydrogen electrode (SHE) are 40 mV more reducing (i.e., more negative) than those for Salado WIPP brine (-480 mV vs. -440 mV, respectively) because of the higher pH of the Castile brine (pH 9 .3 for Castile vs. pH 8.8 for Salado). The E h and pH data were corrected for the effects of high ionic strength. The experimental results for both brines are consistent with thermodynamic predictions using OLI Systems' Mixed Solvent Electrolyte chemical equilibrium model. The measured and corrected pH and E h data from this study are provided in Table ES-I and Table ES-2, respectively. The experimental study, with four test conditions in triplicate, was performed in a dual glovebox with a nominally 3 vol.% H 2 in argon atmosphere (target H 2 range: 3 ± I vol.%). Simulants containing MgO only ( experimental control) and MgO+Fe 0 (WIPP base case) were prepared for both the Salado and Castile brines. MgO was included in all simulants to account for the use of bulk magnesium oxide in the WIPP repository. Fe 0 was included in some simulants to incorporate the effects of the anoxic corrosion of iron and in-situ hydrogen generation in the study. The brine compositions were developed by Sandia National Laboratory (SNL; Xiong, 2008) and have been used in previous WIPP evaluations. The test method (agitation, etc.) is partially based on ASTM D3987-12. Twelve rounds of periodic measurements of pH and E h were performed over the course of the study. Chemical analysis results for liquids and solids (ICP-MS, ICP-ES, IC Anion, TIC, SEM-EDX) are consistent with the pH, E h , and thermodynamic modeling results. This study included the following conditions that deviate from anticipated post-closure conditions following brine intrusion, but were selected to facilitate bench-scale testing to validate modeling of pH and E h for the post-closure WIP P repository: an anoxic glove box atmosphere containing ≤ 4 vol. % H 2 vs. substantially higher H 2 gas concentrations assumed in the WIPP Performance Assessment (PA); a significantly higher liquid-to-solid test ratio compared to the much lower phase ratio anticipated in the WIP P repository; agitation of the simulant bottles to maximize mass transfer; and finally the use of Fe 0 reagents having a much greater surface area than expected in the WIP P repository. Non-representative conditions were chosen for various reasons such as: to provide bounding conservative results, to provide a margin of safety for testing, or to facilitate simulant sub-sampling and analysis. In a parallel effort, aqueous electrolyte thermodynamic models were developed for the synthetic Salado and Castile brines to inform the experimental design, facilitate laboratory data interpretation, and allow extension of evaluations beyond the parameters tested. Thermodynamic modeling simulations including the MgO and Fe 0 additives that are directly relevant to the experimental measurements (e.g., pH calibration curve, ORP corrections) are included in this report. The measured fa of the simulants was close to the OLI model predictions for both brines and was largely controlled by the background H 2 partial pressure in the vapor phase as well as H 2 generated in situ in the aqueous phase by the Fe 0 corrosion. The H 2 gas-phase concentration tested and thermodynamically evaluated was much lower than is assumed in the WIPP PA; however, H 2 (g) concentrations significantly below this level are still predicted to result in very reducing conditions. In conclusion: • The experimental results are consistent with thermodynamic model predictions for fa, pH, and the effects of high ionic strength. • Evidence to date suggests that the H2 concentration in the glovebox atmosphere ultimately determined the final E h values of the simulants and resulted in highly reducing conditions. As a result, little difference was observed between the control simulants containing only MgO and the WIPP base-case simulants that contained MgO and Fe 0 . • This test methodology is recommended for future studies evaluating WIPP repository conditions. The methodology includes: (1) background H 2 in argon with agitation ( or could alternatively include in-situ-generated H 2 in sealed bottles); (2) carefully measured and corrected ORP data ( with much effort focused on allowing the probes to fully stabilize); and (3) ionic-strength-corrected pH data. Other best practices, such as simulant sparging/handling, ORP probe replacement, etc., should also be considered. • The coupling of experimental studies and thermodynamic modeling is also highly recommended because these methods inform and direct one another leading to greater confidence in and understanding of the results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗