Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Double beta decay detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

CUPID: The Next-Generation Neutrinoless Double Beta Decay Experiment

We report CUPID is a next-generation tonne-scale bolometric neutrinoless double beta decay experiment that will probe the Majorana nature of neutrinos and discover lepton number violation in case of observation of this singular process. CUPID will be built on experience, expertise and lessons learned in CUORE and will be installed in the current CUORE infra-structure in the Gran Sasso underground laboratory. The CUPID detector technology, successfully tested in the CUPID-Mo experiment, is based on scintillating bolometers of Li 2 MoO 4 enriched in the isotope of interest 100 Mo. In order to achieve its ambitious science goals, the CUPID collaboration aims to reduce the backgrounds in the region of interest by a factor 100 with respect to CUORE. This performance will be achieved by introducing the high efficient α/β discrimination demonstrated by the CUPID-0 and CUPID-Mo experiments, and using a high transition energy double beta decay nucleus such as 100 Mo to minimize the impact of the gamma background. CUPID will consist of about 1500 hybrid heat-light detectors for a total isotope mass of 250 kg. The CUPID scientific reach is supported by a detailed and safe background model based on CUORE, CUPID-Mo and CUPID-0 results. The required performances have already been demonstrated and will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Mitigation of Backgrounds from Cosmogenic $^{137}$Xe in Xenon Gas Experiments using $^{3}$He Neutron Capture

\Xe{136} is used as the target medium for many experiments searching for \bbnonu. Despite underground operation, cosmic muons that reach the laboratory can produce spallation neutrons causing activation of detector materials. A potential background that is difficult to veto using muon tagging comes in the form of \Xe{137} created by the capture of neutrons on \Xe{136}. This isotope decays via beta decay with a half-life of 3.8 minutes and a \Qb\ of $\sim$4.16 MeV. This work proposes and explores the concept of adding a small percentage of \He{3} to xenon as a means to capture thermal neutrons and reduce the number of activations in the detector volume. When using this technique we find the contamination from \Xe{137} activation can be reduced to negligible levels in tonne and multi-tonne scale high pressure gas xenon neutrinoless double beta decay experiments running at any depth in an underground laboratory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results of the MAJORANA DEMONSTRATOR’s Search for Double-Beta Decay of 76 Ge to Excited States of 76 Se

The MAJORANA DEMONSTRATOR is searching for double-beta decay of 76 Ge to excited states (E.S.) in 76Se using a modular array of high purity Germanium detectors. 76 Ge can decay into three E.S.s of 76 Se. The E.S. decays have a clear event signature consisting of a ββ-decay with the prompt emission of one or two γ-rays, resulting in with high probability in a multi-site event. The granularity of the DEMONSTRATOR detector array enables powerful discrimination of this event signature from backgrounds. Using 21.3 kg-y of isotopic exposure, the DEMONSTRATOR has set world leading limits for each E.S. decay, with 90% CL lower half-life limits in the range of (0.56 – 2.1) • 10 24 y. In particular, for the 2v transition to the first 0 + E.S. of 76 Se, a lower half-life limit of 0.68 • 10 24 at 90% CL was achieved.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Towards a fiber barrel detector for next-generation high-pressure gaseous xenon TPCs

Abstract The NEXT (Neutrino Experiment with a Xenon TPC) project is an international collaboration aimed at finding evidence of neutrinoless double beta decay using gaseous xenon. The current phase of the project involves the construction and operation of NEXT-100, which is designed to hold 100 kg of xenon at 15 bar and is expected to start commissioning in the first quarter of 2024. NEXT-HD will be a tonne scale experiment following NEXT-100 and will incorporate a symmetric design, with one cathode and two anodes. For this detector, the collaboration is considering to implement a barrel of wavelength-shifting fibers read-out by silicon photomultipliers to measure the energy of the particles interacting in the gaseous xenon. In this document, we will discuss the characteristics of this approach and provide an update on the related R&D efforts.

Instruments & Instrumentation↗

Search for Fractionally Charged Particles with CUORE

The Cryogenic Underground Observatory for Rare Events (CUORE) is a detector array comprised by 988 5 cm × 5 cm × 5 cm TeO 2 crystals held below 20 mK, primarily searching for neutrinoless double-beta decay in 130 Te. Unprecedented in size among cryogenic calorimetric experiments, CUORE provides a promising setting for the study of exotic throughgoing particles. Using the first tonne year of CUORE’s exposure, we perform a search for hypothesized fractionally charged particles (FCPs), which are well-motivated by various standard model extensions and would have suppressed interactions with matter. Across the searched range of charges 𝑒/24−𝑒/2 no excess of FCP candidate tracks is observed over background, setting leading limits on the underground FCP flux with charges 𝑒/24 −𝑒/5 at 90% confidence level. Using the low background environment and segmented geometry of CUORE, we establish the sensitivity of tonne-scale subkelvin detectors to diverse signatures of new physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

DIREXENO—an apparatus for measuring correlated scintillation signatures in liquid xenon

We present a detector apparatus, DIREXENO (DIREctional XENOn), designed to measure the spatial and temporal properties of scintillation in liquid xenon to very high accuracy. The properties of scintillation are of primary importance for dark matter and neutrinoless double beta decay experiments; however the complicated microphysics involved limits theoretical predictions. We will explore the possibility that scintillation emission exhibits spatial correlations such as super-radiance which manifests in temporal and spatial structure, depending on the interaction type. Such properties of scintillation light may open a new window for background rejection as well as directionality measurements. We present the apparatus' technical design and the concepts driving it. We demonstrate that for an energy deposition of ~2.5 keV (~7.5 keV) electron (nuclear) recoil the detector is sensitive to an anisotropy fraction of as little as ~ 20% of the total photons emitted over a solid angle of ~0.85 steradian or less. We show results from commissioning runs in which the detector operated with 17 PMTs for over 44 days in stable conditions. The time resolution for individual photons in different PMTs was measured to be ≲1.4 ns full-width at half-maximum

47 OTHER INSTRUMENTATION↗

nEXO: neutrinoless double beta decay search beyond 10 28 year half-life sensitivity

The nEXO neutrinoless double beta (0νββ) decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in 136 Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the half-life of 10 28 years. Specifically, improvements have been made in the understanding of production of scintillation photons and charge as well as of their transport and reconstruction in the detector. The more detailed knowledge of the detector construction has been paired with more assays for trace radioactivity in different materials. In particular, the use of custom electroformed copper is now incorporated in the design, leading to a substantial reduction in backgrounds from the intrinsic radioactivity of detector materials. Furthermore, a number of assumptions from previous sensitivity projections have gained further support from interim work validating the nEXO experiment concept. Together these improvements and updates suggest that the nEXO experiment will reach a half-life sensitivity of 1.35 × 10 28 yr at 90% confidence level in 10 years of data taking, covering the parameter space associated with the inverted neutrino mass ordering, along with a significant portion of the parameter space for the normal ordering scenario, for almost all nuclear matrix elements. Furthermore, the effects of backgrounds deviating from the nominal values used for the projections are also illustrated, concluding that the nEXO design is robust against a number of imperfections of the model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Rare multinucleon decays with the full data sets of the M AJORANA D EMONSTRATOR

The M AJORANA D EMONSTRATOR was an ultra-low-background experiment designed for neutrinoless double-beta decay (0⁢𝜈⁢𝛽⁢𝛽) investigation in 76 Ge . Located at the Sanford Underground Research Facility in Lead, South Dakota, the D EMONSTRATOR utilized modular high-purity Ge detector arrays within shielded vacuum cryostats, operating deep underground. The arrays, with a capacity of up to 40.4 kg (27.2 kg enriched to ∼88% in 76 Ge ), have accumulated the full data set, totaling 64.5 kg yr of enriched active exposure and 27.4 kg yr of exposure for natural detectors. Here, our updated search improves previously explored three-nucleon decay modes in Ge isotopes, setting new partial lifetime limits of 1.83 × 10 26 yr (90% confidence level) for 76 Ge (𝑝⁢𝑝⁢𝑝) → 73 Cu 𝑒 + ⁢𝜋 + ⁢𝜋 + and 76 Ge (𝑝⁢𝑝⁢𝑛) → 73 Zn 𝑒 + ⁢𝜋 + . The partial lifetime limit for the fully inclusive triproton decay mode of 76 Ge is found to be 2.1×10 25 yr. Furthermore, we have updated limits for corresponding multinucleon decays.

baryon & lepton number symmetries↗

A laserball calibration device for the SNO+ scintillator phase

Located 2 km underground in SNOLAB, Sudbury, Canada, SNO+ is a large scale liquid scintillator experiment that primarily aims to search for neutrinoless double beta decay. Whilst SNO+ has light and radioactive calibration sources external to the inner volume, an internally deployed optical source is necessary for the full characterization of the detector model. A laser diffuser ball developed for SNO has previously demonstrated to be an effective optical calibration device for both SNO and SNO+ water phase. Since the introduction of liquid scintillator for SNO+, the material compatibility, cleanliness, and radiopurity requirements of any materials in contact with the internal medium have increased. Improving on the original SNO laserball design, a new laserball calibration device has been developed for the SNO+ scintillator phase with the goal of measuring the optical properties of the detector and performing routine PMT gain and timing calibrations. Simulations have been written to model the diffusion properties to optimise optical and temporal performance for calibration. Prototype laserballs have been built and characterised, demonstrating sub-ns timing resolution and a quasi-isotropic light distribution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for a Sub-eV Sterile Neutrino Using Daya Bay’s Full Dataset

This Letter presents results of a search for the mixing of a sub-eV sterile neutrino with three active neutrinos based on the full data sample of the Daya Bay Reactor Neutrino Experiment, collected during 3158 days of detector operation, which contains 5.55 × 106 reactor $\overline{v}$ e candidates identified as inverse beta-decay interactions followed by neutron capture on gadolinium. The analysis benefits from a doubling of the statistics of our previous result and from improvements of several important systematic uncertainties. No significant oscillation due to mixing of a sub-eV sterile neutrino with active neutrinos was found. Exclusion limits are set by both Feldman-Cousins and CLs methods. Light sterile neutrino mixing with sin 2⁡ 2⁢θ 14 ≳ 0.01 can be excluded at 95% confidence level in the region of 0.01 eV 2 ≲ |Δ⁢$m$$^{2}_{41}$| ≲ 0.1 eV 2 . This result represents the world-leading constraints in the region of 2 × 10 –4 eV 2 ≲ |Δ⁢$m$$^{2}_{41}$| ≲ 0.2 eV 2 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

R&D for LAr + Xe + photosensitive dopants

LArTPCs are the technology of choice for current and future neutrino experiments, including those expected to make eagerly awaited measurements of accelerator neutrino oscillations in the coming decade. This technology provides a large active volume and sensitivity to GeV signals like accelerator neutrinos all the way down to 10s of MeV, covering part of the supernova neutrino spectrum.Expanding the reach of LArTPCs to below the 10 MeV range would substantially enhance the flagship analyses of experiments like DUNE, while potentially enabling the physics of solar neutrinos, dark matter searches, and neutrinoless double beta decay searches.We outline the R&D pathway for photosensitive dopants, whose introduction into the LAr active medium, has the potential to substantially increase ionization yields of LAr detectors and enable the detection of low energy signals in large LArTPCs. This R&D program will demonstrate the feasibility and impacts of introducing doped LAr into current and future neutrino detectors at the kTon scale including the Xenon + photosensitive doping strategy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First-Principles insights into group-V impurities and their impact on germanium detector performance

The outstanding properties of high-purity germanium (HPGe) detectors, such as excellent energy resolution, high energy sensitivity, and a low background-to-signal ratio, make them essential and ideal candidates for detecting particle signatures in nuclear processes such as neutrino-less double beta decay (0νββ). However, the presence of defects and impurities in HPGe crystals can lead to charge trapping, which affects carrier mobility and results in significant energy resolution degradation. In this work, we employ density functional theory with a hybrid functional to study the energetics of possible point defects in Ge. Our findings indicate that group-V impurities form more readily in Ge compared to vacancy and interstitial of Ge. Unlike N dopants, which yield deep trap states, P, As, and Sb create shallow traps close to the conduction band edge of Ge. Furthermore, we predict that group-V defects can condense into defect complexes with Ge vacancies. These vacancy-impurity complexes form deep traps in Ge, similar to Ge vacancies, suggesting that both vacancies and vacancy-impurity complexes contribute to charge trapping in these detectors, thereby diminishing their performance.

36 MATERIALS SCIENCE↗

Reflectivity and PDE of VUV4 Hamamatsu SiPMs in liquid xenon

Considering reflective properties of materials and photodetection efficiency (PDE) of photodetectors is important for optimizing energy resolution and sensitivity of the next generation neutrinoless double beta decay, direct detection dark matter, and neutrino oscillation experiments that will use noble liquid gases, such as nEXO, DARWIN, DarkSide-20k, and DUNE . Little information is currently available about reflectivity and PDE in liquid noble gases, because such measurements are difficult to conduct in a cryogenic environment and at short enough wavelengths. Here we report a measurement of specular reflectivity and relative PDE of Hamamatsu VUV4 silicon photomultipliers (SiPMs) with 50 μ m micro-cells conducted with xenon scintillation light ( ~ 175 nm) in liquid xenon. The specular reflectivity at 15 o incidence of three samples of VUV4 SiPMs is found to be 30.4 ± 1.4%, 28.6 ± 1.3%, and 28.0 ± 1.3%, respectively. The PDE at normal incidence differs by ± 8% (standard deviation) among the three devices. The angular dependence of the reflectivity and PDE was further measured for one of the SiPMs. Both the reflectivity and PDE decrease as the angle of incidence increases. This is the first measurement of an angular dependence of PDE and reflectivity of a SiPM in liquid xenon.

47 OTHER INSTRUMENTATION↗

Readout Noise of Digital Frequency Multiplexed TES Detectors for CUPID

The superconducting transition-edge sensor (TES) detectors have been the standard in cosmic microwave background (CMB) experiments for almost two decades and are now being adapted for use in nuclear physics, such as neutrinoless double beta decay searches. In this article, we focus on a new high-bandwidth frequency multiplexed TES readout system developed for CUPID, a neutrinoless double beta decay experiment that will replace CUORE. In order to achieve the high energy resolution requirements for CUPID, the readout noise of the system must be kept to a minimum. Low TES operating resistance and long wiring between the readout SQUID and the warm electronics are needed for CUPID, prompting a careful consideration of the design parameters of this application of frequency multiplexing. In this work, we characterize the readout noise of the newly designed frequency multiplexed TES readout system for CUPID and construct a noise model to understand it. Here, we find that current sharing between the SQUID coil impedance and other branches of the circuit, as well as the long output wiring, worsen the readout noise of the system. To meet noise requirements, a SQUID with a low input inductance, high transimpedance, and/or low dynamic impedance is needed, and the wiring capacitance should be kept as small as possible. Alternatively, the option of adding a cryogenic low-noise amplifier at the output of the SQUID should be explored.

CUPID↗

Report from the Workshop on Xenon Detector $0\nu\beta\beta$ Searches: Steps Towards the Kilotonne Scale

These proceedings summarize the program and discussions of the ``Workshop on Xenon Detector $0\nu\beta\beta$ Searches: Steps Towards the Kilotonne Scale'' held on October 25-27 2023 at SLAC National Accelerator Laboratory. This workshop brought together experts from the communities of neutrinoless double-beta decay and dark matter detection, to discuss paths forward for the realization of monolithic experiments with xenon approaching the kilotonne scale.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Calibration sources for the LEGEND-200 experiment

In the search for a monochromatic peak as the signature of neutrinoless double beta decay an excellent energy resolution and an ultra-low background around the Q-value of the decay are essential. The LEGEND-200 experiment performs such a search with high-purity germanium detectors enriched in 76 Ge immersed in liquid argon. To determine and monitor the stability of the energy scale and resolution of the germanium diodes, custom-made, low-neutron emission 228 Th sources are regularly deployed in the vicinity of the crystals. Here we describe the production process of the 17 sources available for installation in the experiment, the measurements of their alpha- and gamma- activities, as well as the determination of the neutron emission rates with a low-background LiI(Eu) detector operated deep underground. With a flux of ( 4.27 ± 0.60 stat ± 0.92 syst ) × 10 -4 n / (kBq·s), approximately one order of magnitude below that of commercial sources, the neutron-induced background rate, mainly from the activation of 76 Ge, is negligible compared to other background sources in LEGEND-200.

47 OTHER INSTRUMENTATION↗

Topological background discrimination in the PandaX-III neutrinoless double beta decay experiment

The PandaX-III experiment plans to search for neutrinoless double beta decay (0ν ββ ) of 136 Xe in the China JinPing underground Laboratory (CJPL). The experiment will use a high pressure gaseous time projection chamber (TPC) to register both the energy and the electron track topology of an event. This article is devoted to demonstrate our particular detector setup capabilities for the identification of 0ν ββ and the consequent background reduction. As software tool we use REST, a framework developed for the reconstruction and simulation of TPC-based detector systems. We study the potential for background reduction by introducing appropriate parameters based on the properties of 0ν ββ events. We exploit for the first time not only the energy density of the electron track-ends, but also the electron scattering angles produced by an electron near the end of its trajectory. To implement this, we have added new algorithms for detector signal and track processing inside REST. Their assessment shows that background can be reduced by about 7 orders of magnitude while keeping 0ν ββ efficiency above 20% for the PandaX-III baseline readout scheme, a two-dimensional 3 mm pitch stripped readout. More generally, we use the potential of REST to handle 2D/3D data to assess the impact on signal-to-background significance at different detector granularities, and to validate the PandaX-III baseline choice. Finally, we demonstrate the additional potential to discriminate surface background events generated at the readout plane in the absence of to, by making use of event parameters related with the diffusion of electrons.

Majorana↗

Design improvements to cables and connectors in the Majorana Demonstrator

The Majorana Demonstrator is an experiment constructed to search for neutrinoless double-beta decays in germanium-76 and to demonstrate the feasibility to deploy a ton-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and 76 Ge-enriched germanium p-type point contact detectors totaling 44.1 kg, located at the 4850 level of the Sanford Underground Research Facility in Lead, South Dakota, USA. The Demonstrator uses custom high voltage cables to bias the detectors, as well as custom signal cables and connectors to read out the charge deposited at the point contact of each detector. These low-mass cables and connectors must meet stringent radio purity requirements while being subjected to thermal and mechanical stress. A number of issues have been identified with the currently installed cables and connectors. An improved set of cables and connectors for the Majorana Demonstrator are being developed with the aim of increasing their overall reliability and connectivity. In conclusion, we will discuss some of the issues encountered with the current cables and connectors as well as our improved designs and their initial performance.

42 ENGINEERING↗