Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Dose Threshold”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Phase decomposition and bubble evolution in Xe implanted U 3 Si 2 at 450°C

We report on the microstructure investigations of a U 3 Si 2 specimen implanted by 84 MeV Xe ions at 450°C. In the region that corresponds to the highest irradiation dose, U 3 Si 2 was found to decompose into a Si-enriched nanocrystalline USi matrix phase and a U-enriched amorphous inclusion phase. Density functional theory (DFT) calculations were used to help understand the decomposition mechanism. Xe bubbles of different morphologies were observed in USi nano-grains, on USi grain boundaries, and phase boundaries. Original U 3 Si 2 micro-grains were preserved on both sides of the irradiation damage peak region within the sample, implying a radiation dose threshold for decomposition of approximately 150 dpa at 450°C. In the preserved U 3 Si 2 region beneath the irradiation damage peak, where critical amount of Xe ions were deposited, a monomodal size distribution of intragranular Xe bubbles with an average size of 2.68 nm formed. In both decomposed and preserved U 3 Si 2 , the size of Xe bubbles was found to be lower than 50 nm. Based on this observation, the fission gas behavior of U 3 Si 2 is controllable and free of run-away swelling despite the occurrence of decomposition at this irradiation temperature. (C) 2019 Elsevier B.V. All rights reserved.

36 MATERIALS SCIENCE↗

Structure of the pellet-cladding interaction layer of a high-burnup Zr-Nb-O nuclear fuel cladding

Here, structure of the pellet/cladding-interaction (PCI) layer of a high-burnup nuclear fuel with niobium-bearing cladding was investigated using modern transmission electron microscopy (TEM) techniques. Morphology of the PCI consisted of uniform zirconia layer on the cladding side and finger-like features towards to the ceramic fuel. The PCI layer showed a complex microstructure that constitutes three distinct zirconia layers formed by two zirconia phases. From cladding to fuel, monoclinic, tetragonal, and another tetragonal phase were determined via TEM diffraction patterns and precession electron diffraction (PED) using ASTAR microscopy platform (AMP). Characterizations showed that monoclinic and tetragonal phases close to the cladding were crack-free, but the tetragonal layer adjacent to the fuel contained cracks and pores. Presence of the monoclinic layer suggested that its formation involved the gaseous diffusion of oxygen below threshold dose of fission product damage before the fuel/cladding contact occurred. Furthermore, high-resolution TEM revealed compound phase of (U,Zr)O 2 at fringes of zirconia fingers on the fuel side.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Direct in Situ Determination of the Mechanisms Controlling Nanoparticle Nucleation and Growth

Although nanocrystal morphology is controllable using conventional colloidal synthesis, multiple characterization techniques are typically needed to determine key properties like the nucleation rate, induction time, growth rate, and the resulting morphology. Recently, researchers have demonstrated growth of nanocrystals by in situ electron beam reduction, offering direct observations of single nanocrystals and eliminating the need for multiple characterization techniques; however, they found nanocrystal morphologies consistent with two different growth mechanisms for the same electron beam parameters. Here we show that the electron beam current plays a role analogous to the concentration of reducing agent in conventional synthesis, by controlling the growth mechanism and final morphology of silver nanocrystals grown via in situ electron beam reduction. We demonstrate that low beam currents encourage reaction limited growth that yield nanocrystals with faceted structures, while higher beam currents encourage diffusion limited growth that yield spherical nanocrystals. By isolating these two growth regimes, we demonstrate a new level of control over nanocrystal morphology, regulated by the fundamental growth mechanism. We find that the induction threshold dose for nucleation is independent of the beam current used for imaging, but is a function of the interaction volume size. Our results indicate that in situ electron microscopy data can be interpreted by classical models, by allowing simultaneous measurement of nucleation induction times, growth rates, and evolution of nanocrystal morphology. The results suggest that systematic dose experiments should be performed for all future in situ liquid studies to confirm the exact mechanisms underlying observations of nucleation and growth.

Classical nucleation theory↗

Study of the Effects of Ultrasonic Waves on the Reproductive Integrity of Mammalian Cells Cultured in Vitro

The effects of monochromatic ultrasonic waves of 0.1, 0.5, 1.0, 2.0 and, 3.3 MHz frequency on the colony-forming ability of mammalian cells (M3-1,V79, Chang's and T-1) cultured in vitro have been studied to determine the nature of the action of ultrasonic energy on biological systems at the cellular level. The combined effect of ultrasound and X-rays has also been studied. It is concluded: (1) Ultrasonic irradiation causes both lethal and sublethal damage. (2) There is a threshold dose rate for lethal effects. (3) The effectiveness of ultrasonic waves in causing cell death probably depends on the frequency and the amplitude of the waves for a given cell line, indicating a possible resonance phenomenon.

Martins, B. I.↗

Effects Of Radiation On Insulators

Report presents data on responses of electrically insulating thermosetting and thermoplastic polymers to radiation. Lowest-threshold-dose (LTD) levels and 25-percent-change levels presented for such properties as tensile strength and electrical resistivity. Data on radiation-induced outgassing also given.

Bouquet, Frank L.↗

Late cataractogenesis caused by particulate radiations and photons in long-lived mammalian species

Radiation cataractogenesis induced by small acute doses of particulate radiations and photons in the New Zealand white rabbit (Oryctolagus cuniculus), the beagle dog (Canis familiaris) and the rhesus monkey (Macaca mulatta) is discussed in the context of the use of animal models to assess the radiation hazards faced by humans during lengthy sojourns in deep space. Attention is paid to (1) the importance of lifespan studies with long-lived species - the above animals have median lifespans in captivity of 5-7, 13-14 and 25 years, respectively; and (2) the magnitudes of possible dose thresholds for cataractogenesis from sparsely ionizing radiations and the modifications of those thresholds by the late degenerative phase of the phenomenon.

Lett, J. T.↗

Radiation protection issues in galactic cosmic ray risk assessment

Radiation protection involves the limitation of exposure to below threshold doses for direct (or deterministic) effects and a knowledge of the risk of stochastic effects after low doses. The principal stochastic risk associated with low dose rate galactic cosmic rays is the increased risk of cancer. Estimates of this risk depend on two factors (a) estimates of cancer risk for low-LET radiation and (b) values of the appropriate radiation weighting factors, WR, for the high-LET radiations of galactic cosmic rays. Both factors are subject to considerable uncertainty. The low-LET cancer risk derived from the late effects of the atomic bombs is vulnerable to a number of uncertainties including especially that from projection in time, and from extrapolation from high to low dose rate. Nevertheless, recent low dose studies of workers and others tend to confirm these estimates. WR, relies on biological effects studied mainly in non-human systems. Additional laboratory studies could reduce the uncertainties in WR and thus produce a more confident estimate of the overall risk of galactic cosmic rays.

NASA Program Radiation Health↗

Historical Study of Radiation Exposures and the Incidence of Cataracts in Astronauts

For over 35 years, astronauts in low Earth orbit or on missions to the moon have been exposed to space radiation comprised of high-energy protons, heavy ions, and secondary neutrons. We reviewed the radiation exposures received by astronauts in space and on Earth, and presented results from the first epidemiological study of cataract incidence in the astronauts. Our data suggested an increased risk for cataracts from space radiation exposures. Using parametric survival analysis and the maximum likelihood method, we estimated the dose-response and age distribution for cataract incidence in astronauts by space radiation. Considering the high-LET dose contributions on specific space missions as well as data from animal studies with neutrons and heavy ions, suggested a linear response with no dose-threshold for cataracts. However, there are unanswered questions related to the importance and the definition of clinically significant cataracts commonly used in radiation protection, especially in light of epidemiological data suggesting that the probability that sub-clinical cataracts will progress is highly dependent on the age at which cataracts appear. We briefly describe a new study that will address the measurement of cataract progression-rates in astronauts and a ground-based comparison group.

Cucinotta, F. A.↗

Historical Study of Radiation Exposures and the Incidence of Cataracts in Astronauts

For over 35 years, astronauts in low Earth orbit or on missions to the moon have been exposed to space radiation comprised of high-energy protons, heavy ions, and secondary neutrons. We reviewed the radiation exposures received by astronauts in space and on Earth, and presented results from the first epidemiological study of cataract incidence in the astronauts. Our data suggested an increased risk for cataracts from space radiation exposures*. Using parametric survival analysis and the maximum likelihood method, we estimated the dose-response and age distribution for cataract incidence in astronauts by space radiation. Considering the high-LET dose contributions on specific space missions as well as data from animal studies with neutrons and heavy ions, suggested a linear response with no dose-threshold for cataracts. However, there are unanswered questions related to the importance and the definition of "clinically significant" cataracts commonly used in radiation protection, especially in light of epidemiological data suggesting that the probability that "sub-clinical" cataracts will progress is highly dependent on the age at which cataracts appear. We briefly describe a new study that will address the measurement of cataract progression-rates in astronauts and a ground-based comparison group.

Cucinotta, F. A.↗

Space Radiation Heart Disease Risk Estimates for Lunar and Mars Missions

The NASA Space Radiation Program performs research on the risks of late effects from space radiation for cancer, neurological disorders, cataracts, and heart disease. For mortality risks, an aggregate over all risks should be considered as well as projection of the life loss per radiation induced death. We report on a triple detriment life-table approach to combine cancer and heart disease risks. Epidemiology results show extensive heterogeneity between populations for distinct components of the overall heart disease risks including hypertension, ischaemic heart disease, stroke, and cerebrovascular diseases. We report on an update to our previous heart disease estimates for Heart disease (ICD9 390-429) and Stroke (ICD9 430-438), and other sub-groups using recent meta-analysis results for various exposed radiation cohorts to low LET radiation. Results for multiplicative and additive risk transfer models are considered using baseline rates for US males and female. Uncertainty analysis indicated heart mortality risks as low as zero, assuming a threshold dose for deterministic effects, and projections approaching one-third of the overall cancer risk. Medan life-loss per death estimates were significantly less than that of solid cancer and leukemias. Critical research questions to improve risks estimates for heart disease are distinctions in mechanisms at high doses (>2 Gy) and low to moderate doses (<2 Gy), and data and basic understanding of radiation doserate and quality effects, and individual sensitivity.

Cucinotta, Francis A.↗

Integration of the Cardiovascular Clinical Risk Prediction Model Astro-CHARM Into the NASA Radiation Risk Model

Space radiation poses an increased risk for cardiovascular diseases (CVD) during and after spaceflight, that should be quantified to plan future space missions such as the flight to Mars. The radiation-induced CVD risk is evaluated using a linear no-threshold dose response excess relative risk (ERR) model, so that the risk is function of the radiation dose and of the background (i.e., non-exposed) incidence rate. The background CVD risk can be evaluated using clinical prediction models (CPMs). The first CPMs developed in the 1960’s have identified CVD risk factors such as blood pressure, diabetes, cholesterol, and smoking. In this work, the steps used to integrate the CVD risk provided by a CPM into the NASA Radiation Risk Model are described. Simulation results calculated using available data for relevant mission scenarios are also shown, and the challenges in CVD risk predictions are discussed.

I Plante↗

Integration of the Cardiovascular Risk Model Astro-CHARM in the NASA Radiation Risk Model

Space radiation poses an increased risk for cardiovascular diseases (CVD) during and after spaceflight, that should be quantified to plan future space missions such as the flight to Mars. The radiation-induced CVD risk is evaluated using a linear no-threshold dose response excess relative risk (ERR) model, so that the risk is function of the radiation dose and of the background (i.e., non-exposed) incidence rate. The background CVD risk can be evaluated using clinical prediction models (CPMs). The first CPMs developed in the 1960’s have identified CVD risk factors such as blood pressure, diabetes, cholesterol, and smoking. In this work, the steps used to integrate the CVD risk provided by a CPM into the NASA Radiation Risk Model are described. Simulation results calculated using available data for relevant mission scenarios are also shown, and the challenges in CVD risk predictions are discussed.

Space radiation↗

Nuclear radiation-warning detector that measures impedance

This invention is a nuclear radiation-warning detector that measures impedance of silver-silver halide on an interdigitated electrode to detect light or radiation comprised of alpha particles, beta particles, gamma rays, X rays, and/or neutrons. The detector is comprised of an interdigitated electrode covered by a layer of silver halide. After exposure to alpha particles, beta particles, X rays, gamma rays, neutron radiation, or light, the silver halide is reduced to silver in the presence of a reducing solution. The change from the high electrical resistance (impedance) of silver halide to the low resistance of silver provides the radiation warning that detected radiation levels exceed a predetermined radiation dose threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The threshold vs LNT showdown: Dose rate findings exposed flaws in the LNT model part 1. The Russell-Muller debate

This paper assesses the discovery of the dose-rate effect in radiation genetics and how it challenged fundamental tenets of the linear non-threshold (LNT) dose response model, including the assumptions that all mutational damage is cumulative and irreversible and that the dose-response is linear at low doses. Newly uncovered historical information also describes how a key 1964 report by the International Commission for Radiological Protection (ICRP) addressed the effects of dose rate in the assessment of genetic risk. This unique story involves assessments by two leading radiation geneticists, Hermann J. Muller and William L. Russell, who independently argued that the report's Genetic Summary Section on dose rate was incorrect while simultaneously offering vastly different views as to what the report's summary should have contained. This paper reveals occurrences of scientific disagreements, how conflicts were resolved, which view(s) prevailed and why. During this process the Nobel Laureate, Muller, provided incorrect information to the ICRP in what appears to have been an attempt to manipulate the decision-making process and to prevent the dose-rate concept from being adopted into risk assessment practices. - Highlights: • The discovery of radiation dose rate challenged the scientific basis of LNT. • Radiation dose rate occurred in males and females. • The dose rate concept supported a threshold dose-response for radiation.

54 ENVIRONMENTAL SCIENCES↗

Tomotherapy treatment plan quality assurance: The impact of applied criteria on passing rate in gamma index method

Purpose: Pretreatment patient plan verification with gamma index (GI) metric analysis is standard procedure for intensity modulated radiation therapy (IMRT) treatment. The aim of this paper is to evaluate the variability of the local and global gamma index obtained during standard pretreatment quality assurance (QA) measurements for plans performed with Tomotherapy unit. The QA measurements were performed with a 3D diode array, using variable passing criteria: 3%/3 mm, 2%/2 mm, 1%/1 mm, each with both local and global normalization.Methods: The authors analyzed the pretreatment QA results for 73 verifications; 37 were prostate cancer plans, 16 were head and neck plans, and 20 were other clinical sites. All plans were treated using the Tomotherapy Hi-Art System. Pretreatment QA plans were performed with the commercially available 3D diode array ArcCHECK™. This device has 1386 diodes arranged in a helical geometry spaced 1 cm apart. The dose measurements were acquired on the ArcCHECK™ and then compared with the calculated dose using the standard gamma analysis method. The gamma passing rate (%GP), defined as the percentage of points satisfying the condition GI < 1, was calculated for different criteria (3%/3 mm, 2%/2 mm, 1%/1 mm) and for both global and local normalization. In the case of local normalization method, the authors set three dose difference threshold (DDT) values of 2, 3, and 5 cGy. Dose difference threshold is defined as the minimum absolute dose error considered in the analysis when using local normalization. Low-dose thresholds (TH) of 5% and 10% were also applied and analyzed.Results: Performing a paired-t-test, the authors determined that the gamma passing rate is independent of the threshold values for all of the adopted criteria (5%TH vs 10%TH, p > 0.1). Our findings showed that mean %GPs for local (or global) normalization for the entire study group were 93% (98%), 84% (92%), and 66% (61%) for 3%/3 mm, 2%/2 mm, and 1%/1 mm criteria, respectively. DDT was equal to 2 cGy for the local normalization analysis cases. The authors observed great variability in the resulting %GP. With 3%/3 mm gamma criteria, the overall passing rate with local normalization was 4.6% less on the average than with global one, as expected. The wide difference between %GP calculated with global or local approach is also confirmed by an unpaired t-test statistical analysis.Conclusions: The variability of %GP obtained confirmed the necessity to establish defined agreement criteria that could be universal and comparable between institutions. In particular, while the gamma passing rate does not depend on the choice of threshold, the choice of DDT strongly influences the gamma passing rate for local calculations. The difference between global and local %GP was statistically significant for prostate and other treatment sites when DDT was changed from 2 to 3 cGy.

61 RADIATION PROTECTION AND DOSIMETRY↗

The threshold vs LNT showdown: Dose rate findings exposed flaws in the LNT model part 2. How a mistake led BEIR I to adopt LNT

This paper reveals that nearly 25 years after the used Russell's dose-rate data to support the adoption of the linear-no-threshold (LNT) dose response model for genetic and cancer risk assessment, Russell acknowledged a significant under-reporting of the mutation rate of the historical control group. This error, which was unknown to BEIR I, had profound implications, leading it to incorrectly adopt the LNT model, which was a decision that profoundly changed the course of risk assessment for radiation and chemicals to the present. -- Highlights: • The BEAR I Genetics Panel made an error in denying dose rate for mutation. • The BEIR I Genetics Subcommittee attempted to correct this dose rate error. • The control group used for risk assessment by BEIR I is now known to be in error. • Correcting this error contradicts the LNT, supporting a threshold model.

54 ENVIRONMENTAL SCIENCES↗

Clinical Response of Pelvic and Para-aortic Lymphadenopathy to a Radiation Boost in the Definitive Management of Locally Advanced Cervical Cancer

Purpose: Optimal treatment with radiation for metastatic lymphadenopathy in locally advanced cervical cancer remains controversial. We investigated the clinical dose response threshold for pelvic and para-aortic lymph node boost using radiographic imaging and clinical outcomes. Methods and Materials: Between 2007 and 2011, 68 patients were treated for locally advanced cervical cancer; 40 patients had clinically involved pelvic and/or para-aortic lymph nodes. Computed tomography (CT) or 18F-labeled fluorodeoxyglucose-positron emission tomography scans obtained pre- and postchemoradiation for 18 patients were reviewed to assess therapeutic radiographic response of individual lymph nodes. External beam boost doses to involved nodes were compared to treatment response, assessed by change in size of lymph nodes by short axis and change in standard uptake value (SUV). Patterns of failure, time to recurrence, overall survival (OS), and disease-free survival (DFS) were determined. Results: Sixty-four lymph nodes suspicious for metastatic involvement were identified. Radiation boost doses ranged from 0 to 15 Gy, with a mean total dose of 52.3 Gy. Pelvic lymph nodes were treated with a slightly higher dose than para-aortic lymph nodes: mean 55.3 Gy versus 51.7 Gy, respectively. There was no correlation between dose delivered and change in size of lymph nodes along the short axis. All lymph nodes underwent a decrease in SUV with a complete resolution of abnormal uptake observed in 68%. Decrease in SUV was significantly greater for lymph nodes treated with ≥54 Gy compared to those treated with <54 Gy (P=.006). Median follow-up was 18.7 months. At 2 years, OS and DFS for the entire cohort were 78% and 50%, respectively. Locoregional control at 2 years was 84%. Conclusions: A biologic response, as measured by the change in SUV for metastatic lymph nodes, was observed at a dose threshold of 54 Gy. We recommend that involved lymph nodes be treated to this minimum dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gravitropic responses of the Avena coleoptile in space and on clinostats. II. Is reciprocity valid?

Experiments were undertaken to determine if the reciprocity rule is valid for gravitropic responses of oat coleoptiles in the acceleration region below 1 g. The rule predicts that the gravitropic response should be proportional to the product of the applied acceleration and the stimulation time. Seedlings were cultivated on 1 g centrifuges and transferred to test centrifuges to apply a transverse g-stimulation. Since responses occurred in microgravity, the uncertainties about the validity of clinostat simulation of weightlessness was avoided. Plants at two stages of coleoptile development were tested. Plant responses were obtained using time-lapse video recordings that were analyzed after the flight. Stimulus intensities and durations were varied and ranged from 0.1 to 1.0 g and from 2 to 130 min, respectively. For threshold g-doses the reciprocity rule was obeyed. The threshold dose was of the order of 55 g s and 120 g s, respectively, for two groups of plants investigated. Reciprocity was studied also at bending responses which are from just above the detectable level to about 10 degrees. The validity of the rule could not be confirmed for higher g-doses, chiefly because the data were more variable. It was investigated whether the uniformity of the overall response data increased when the gravitropic dose was defined as (gm x t) with m-values different from unity. This was not the case and the reciprocity concept is, therefore, valid also in the hypogravity region. The concept of gravitropic dose, the product of the transverse acceleration and the stimulation time, is also well-defined in the acceleration region studied. With the same hardware, tests were done on earth where responses occurred on clinostats. The results did not contradict the reciprocity rule but scatter in the data was large.

Flight Experiment↗