Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Dose Estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Interplanetary crew exposure estimates for the August 1972 and October 1989 solar particle events

Detailed exposure estimates for the bone marrow, ocular lens, and skin of astronauts on manned missions beyond the earth's magnetosphere have been made for the large solar particle events (SPE) of August 1972 and October 1989. The estimates were made using the coupled neutron-proton space radiation transport computer code BRYNTRN and the CAM model for the human body. It is found that at least 10 g/sq cm aluminum shielding is needed to keep estimated dose equivalent values below current space radiation exposure guidelines recommended for LEO missions. Space suits currently being designed will not provide adequate crew protection and may not even ensure crew survival in the event of exposure to a large SPE during extravehicular activity.

Townsend, Lawrence W.↗

Potential health risks from postulated accidents involving the Pu-238 RTG on the Ulysses solar exploration mission

Potential radiation impacts from launch of the Ulysses solar exploration experiment were evaluated using eight postulated accident scenarios. Lifetime individual dose estimates rarely exceeded 1 mrem. Most of the potential health effects would come from inhalation exposures immediately after an accident, rather than from ingestion of contaminated food or water, or from inhalation of resuspended plutonium from contaminated ground. For local Florida accidents (that is, during the first minute after launch), an average source term accident was estimated to cause a total added cancer risk of up to 0.2 deaths. For accidents at later time after launch, a worldwide cancer risk of up to three cases was calculated (with a four in a million probability). Upper bound estimates were calculated to be about 10 times higher.

Goldman, Marvin↗

Relative Efficiency of TLD-100 to High Linear Energy Transfer Radiation: Correction to Astronaut Absorbed Dose

Response of thermoluminescent detectors (TLD-100) to high linear energy transfer (LET) particles has been studied using helium, carbon, silicon, and iron ions from the Heavy Ion Medical Accelerator at Chiba (Japan), iron ions from the Brookhaven National Laboratory (NY) Alternate Gradient Synchrotron, and 53, 134, 185, and 232 MeV protons from the Loma Linda accelerator. Using the measured relative (to 137Cs) dose efficiency, and measured LET spectra from a tissue equivalent proportional counter (TEPC) on 20 Space Shuttle flights, and 7 Mir flights, the underestimation of absorbed dose by these detectors has been evaluated. The dose underestimation is between 15-20% depending upon the flight inclination and shielding location. This has been confirmed by direct correlation of measured dose by TEPC and TLD-100 at a low shielded location in the Shuttle mid-deck. A comparison of efficiency- LET data with a compilation of similar data from TLD-700, shows that shapes of the two curves are nearly identical, but that the TLD-100 curve is systematically lower by about 13%, and is the major cause of dose underestimation. These results strongly suggest that TLDs used for crew dose estimation be regularly calibrated using heavy ions.

Badhwar, G. D.↗

Relative Efficiency of TLD-100 to Linear Energy Transfer Radiation: Correction to Astronaut Absorbed Dose

Response of thermoluminescent detectors (TLD-100) to high linear energy transfer (LET) particles has been studied using helium, carbon, silicon, and iron ions from the Heavy Ion Medical Accelerator at Chiba (Japan), iron ions from the Brookhaven National Laboratory (NY) Alternate Gradient Synchrotron, and 53, 134, 185, and 232 MeV protons from the Loma Linda accelerator. Using the measured relative (to (137)Cs dose efficiency, and measured LET spectra from a tissue equivalent proportional counter (TEPC) on 20 Space Shuttle flights, and 7 Mir flights, the underestimation of absorbed dose by these detectors has been evaluated. The dose underestimation is between 15-20% depending upon the flight inclination and shielding location. This has been confirmed by direct correlation of measured dose by TEPC and TLD-100 at a low shielded location in the Shuttle mid-deck. A comparison of efficiency- LET data with a compilation of similar data from TLD-700, shows that shapes of the two curves are nearly identical, but that the TLD-100 curve is systematically lower by about 13%, and is the major cause of dose underestimation. These results strongly suggest that TLDs used for crew dose estimation be regularly calibrated using heavy ions.

Badhwar, Gautam D.↗

The effect of space radiation on the induction of chromosome damage

To obtain information on the cytogenetic damage caused by space radiation, chromosome exchanges in lymphocytes from crewmembers of long-term Mir missions, and a shorter duration shuttle mission, were examined using fluorescence in situ hybridization. A significant increase in chromosomal aberrations was observed after the long duration flights. The ratio of aberrations identified as complex was higher post-flight for some crewmembers, which is thought to be an indication of exposure to high-LET radiation. Ground-based studies have shown that the frequency of aberrations measured post-flight could be influenced by a mitotic delay in cells damaged by high-LET radiation and this effect could lower biological dose estimates. To counteract this effect, prematurely condensed chromosome (PCC) spreads were collected. Frequencies of aberrations in PCC were compared with those in metaphase spreads.

long duration↗

Examination Of IASCC In 304 Stainless Steel Core Shroud From A Commercial Boiling Water Reactor (BWR)

The 304 stainless steel core shroud and the accompanying weld material from a commercial boiling-water reactor (BWR) experienced an estimated dose of ~3.5 dpa neutron irradiation leading to irradiation-assisted stress corrosion cracking (IASCC). The resulting IASCC crack tips are examined with high-resolution analysis techniques, including scanning electron microscopy (SEM), scanning transmission electron microscopy (STEM), and atom probe tomography (APT), with select examples of directly correlated STEM/APT observations. Analytical observations reveal the crack morphology, composition, microstructure, and any associated corrosion-induced or radiation-induced segregation in the local metal grain boundaries ahead of the propagating SCC cracks. The observed oxide composition and structure were in-line with expectations, consisting of a Cr-rich inner oxide and a Fe-rich outer oxide, with the leading crack tip oxide being Cr-rich. In addition, the leading grain boundary exhibited typical radiation-induced segregation signatures that were largely unperturbed by the accompanying corrosion. Finally, the quantitative capabilities and limitations of STEM and APT in the context of corrosion fronts and grain boundary chemistry from the directly correlated measurements are discussed.

Olszta, Matthew J.↗

NUTRON NESHAPs Dashboard

My project aims to enhance the Nuclear Material Tracking Application (NUTRON) software by integrating a tool for the National Emission Standards for Hazardous Air Pollutants (NESHAP) emissions calculations and presenting this data on a dashboard. Inefficiencies in the current NESHAP calculation process were addressed, which will result in more timely regulatory compliance efforts. Key improvements include revising the transfer request system, incorporating effective dose calculations, and developing a data visualization dashboard into NUTRON. The project involved creating a wireframe, preparing an Engineering Calculations and Analysis Report (ECAR), stakeholder meetings, and providing supplemental documentation. Key findings indicate that the proposed modifications will streamline the NESHAP calculation process, reduce human error, and provide REC personnel with accurate and timely data for material use determinations and dose estimations. Future work focuses on completing the NUTRON modifications and fully integrating the new features, ensuring a more efficient and reliable system for tracking and reporting nuclear material transfers.

99 - GENERAL AND MISCELLANEOUS↗

Estimating the Noise Dose Range of the NASA X-59 Aircraft in Supersonic Cruise Using PCBoom Propagation Simulations

PCBoom propagation simulations of the NASA X-59 low-boom in supersonic cruise were conducted using near-field CFD pressure waveforms as inputs to estimate the noise dose range. Low-booms were propagated through realistic atmospheric profiles from the Climate Forecast System Version 2 across the USA, and loudness statistics of the low-booms are presented. The near-field waveforms correspond to aircraft configurations expected to produce minimum- and maximum-loudness levels on the ground. The simulations show that the practical Perceived Level noise dose range is 72 to 86.7 dB. Dose ranges for other single event and cumulative sonic boom metrics of interest are also provided.

X-59↗

Preliminary Criticality and Radiation Shielding Analysis for the Storage and Transfer of MARVEL Reactor Spent Nuclear Fuel

This report documents the results of preliminary nuclear criticality and radiation shielding assessments during transfer and dry storage of irradiated Microreactor Applications Research Validation and Evaluation (MARVEL) reactor fuel at Idaho National Laboratory (INL). The assessments focus on transfer casks and storage canisters that are currently in use at INL, which may be compatible with the irradiated MARVEL reactor fuel. The criticality assessments were performed using the radiation transport code MCNP6 with 37 MARVEL reactor fuel elements in various configurations and scenarios. All transfer and storage configurations under dry conditions were below the assumed criticality safety limit of 0.93. Some storage and transfer configurations under wet conditions exceeded the criticality safety limit. This suggests that the appropriate administrative and engineering controls, in addition to reducing the number of MARVEL reactor fuel elements per transfer cask or storage canister, can be expected to ensure criticality safety under all scenarios. The radiation shielding assessments were performed by generating conservative neutron and photon source terms using the ORIGEN module in the SCALE suite of codes. These source spectra were used to estimate the dose equivalent rates using the radiation transport code MCNP6, both on contact and 1 m away from the fuel and transfer casks. The maximum estimated dose equivalent rate of 37 unshielded MARVEL reactor fuel elements on contact is approximately 42000 R/hr. The maximum estimated dose equivalent rates on contact to the ATR transfer cask, HFEF-5 transfer cask, and high load charger were approximately 233 mR/hr, 171 mR/hr, and 201 mR/hr, respectively. This suggests that with the appropriate administrative and engineering controls, all three transfer casks analyzed can be expected to provide sufficient radiation shielding to workers during transfer of irradiated MARVEL reactor fuel. These calculations are performed to support the planning and strategy for the MARVEL project and will demonstrate the technical viability of the different configurations discussed and help identify where engineered or administrative controls may be necessary. A complete criticality safety analysis and radiation shielding analysis, including validation and contingency and accident analysis must be completed by licensed and authorized personnel before any transfer or storage of MARVEL reactor nuclear fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Estimate of Gamma Dose Rates from Arrays of Fermi-1 Blanket Elements During the MEDE Process

The Enrico Fermi Atomic Power Plant Unit 1 (Fermi-1) was a sodium-cooled fast breeder reactor located in Monroe County, Michigan. The reactor was powered by a core of enriched uranium metal alloy driver fuel, which was enveloped by an axial and radial blanket material consisting of depleted uranium metal alloyed with 3 wt.% molybdenum. There are 406 axial and 559 radial irradiated sodium-bonded Fermi-1 blanket assemblies in storage at INL, totaling 34 metric tons of heavy metal. Disposal of the Fermi-1 blanket material directly into a geological repository is prohibited due to the reactive characteristic of its bond sodium. A melt drain evaporate (MEDE) process can effectively remove bond sodium from Fermi-1 blanket material. Consequently, planning is underway to apply a MEDE process to treat the 34 metric tons of heavy metal of irradiated Fermi-1 blanket material. Given the irradiated Fermi-1 blanket material’s relatively low power history and 50+ years of decay, it can be treated in a shielded glovebox. To assess the requisite shielding, the dose rates of the Fermi-1 blanket elements in various process configurations are needed. The method to perform the dose rate calculations is to first generate an average source term and associated photon source spectra for the Fermi-1 blanket material in SCALE and then use the associated photon spectra to calculate dose rates using MCNP6.2 in seven representative geometries. Dose rates in rem/h were calculated on contact (1 cm from outer geometry surface), 30 cm away from outer geometry surface, and 1 m from outer geometry surface at axial heights spanning the length of the blanket material within the geometry. The maximum average dose rate for the single Fermi-1 radial blanket element is ~0.60 rem/h, for the Fermi-1 radial blanket assembly ~1.10 rem/h, for the single Fermi-1 axial blanket element ~0.5 rem/h, for the Fermi-1 axial blanket assembly ~1.01 rem/h, for the MEDE can ~ 0.98 rem/h, for the Fermi Storage Canister ~ 0.83 rem/h, and for the MEDE cans in the DOE Standard Canister ~0.51 rem/h. Based on these maximum average values, the bounding dose rates are assumed to be 3× the average dose rates calculated for the axial blanket material and 7.6× the average dose rates calculated for the radial blanket material, based on the distribution of Fermi-1 blanket material assembly burnup.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Observation of the Radiation Environment and Solar Energetic Particle Events in Mars Orbit in May 2018- June 2022

Epithermal Neutron Detector (FREND). Here we present results from measurements of the charged particle fluxes, dose rates and estimation of dose equivalent rates at ExoMars TGO Mars science orbit, provided by Liulin-MO from May 2018 to June 2022. The period of measurements covers the declining and minimum phases of the solar activity in 24th solar cycle and the rising phase of the 25th cycle. Compared are the radiation values of the galactic cosmic rays (GCR) obtained during the different phases of the solar activity. The highest values of the dose rate and flux from GCR are registered from March to August 2020. At the minimum of 24th and transition to 25th solar cycle the dose rate from GCR is 15.9 ± 1.6 µGy h−1, particle flux is 3.3 ± 0.17 cm−2 s−1, dose equivalent rate is 72.3 ± 14.4 µSv h−1. Since September 2020 the dose rate and flux of GCR decrease. Particular attention is drawn to the observation of the solar energetic particle (SEP) events in July, September and October 2021, February and March 2022 as well as their effects on the radiation environment on TGO during the corresponding periods. The SEP event during15–19 February 2022 is the most powerful event observed in our data. The SEP dose during this event is 13.8 ± 1.4 mGy (in Si), the SEP dose equivalent is 21.9 ± 4.4 mSv. SEP events recorded in Mars orbit are related to coronal mass ejections (CME) observed by SOHO and STEREO A coronagraphs. Compared are the time profiles of the count rates measured by Liulin-MO, the neutron detectors of FREND and neutron detectors of the High Energy Neutron Detector (HEND) aboard Mars Odyssey during 15–19 February 2022 event. The data obtained is important for the knowledge of the radiation environment around Mars, regarding future manned and robotic flights to the planet. The data for SEP events in Mars orbit during July 2021-March 2022 contribute to the details on the solar activity at a time when Mars is on the opposite side of the Sun from Earth.

Jordanka Semkova↗

Computer subroutines for the estimation of nuclear reaction effects in proton-tissue-dose calculations

Calculational methods for estimation of dose from external proton exposure of arbitrary convex bodies are briefly reviewed. All the necessary information for the estimation of dose in soft tissue is presented. Special emphasis is placed on retaining the effects of nuclear reaction, especially in relation to the dose equivalent. Computer subroutines to evaluate all of the relevant functions are discussed. Nuclear reaction contributions for standard space radiations are in most cases found to be significant. Many of the existing computer programs for estimating dose in which nuclear reaction effects are neglected can be readily converted to include nuclear reaction effects by use of the subroutines described herein.

Wilson, J. W.↗

Mortality among Tennessee Eastman Corporation (TEC) uranium processing workers, 1943–2019

Background: There are few occupational studies of women exposed to ionizing radiation. During World War II, the Tennessee Eastman Corporation (TEC) operated an electromagnetic field separation facility of 1152 calutrons to obtain enriched uranium (235U) used for the Hiroshima atomic bomb. Thousands of women were involved in these operations. Materials and methods: We report a new study was conducted of 13,951 women and 12,699 men employed at TEC between 1943 and 1947 for at least 90 days. Comprehensive dose reconstruction techniques were used to estimate lung doses from the inhalation of uranium dust based on airborne measurements. Vital status through 2018/2019 was obtained from the National Death Index, Social Security Death Index, Tennessee death records and online public record databases. Analyses included standardized mortality ratios (SMRs) and Cox proportional hazards models. Results: Most workers were hourly (77.7%), white (95.6%), born before 1920 (58.3%), worked in dusty environments (57.0%), and had died (94.9%). Vital status was confirmed for 97.4% of the workers. Women were younger than men when first employed: mean ages 25.0 years and 33.0 years, respectively. The estimated mean absorbed dose to the lung was 32.7 mGy (max 1048 mGy) for women and 18.9 mGy (max 501 mGy) for men. The mean dose to thoracic lymph nodes (TLNs) was 127 mGy. Statistically significant SMRs were observed for lung cancer (SMR 1.25; 95% CI 1.19, 1.31; n = 1654), nonmalignant respiratory diseases (NMRDs) (1.23; 95% CI 1.19, 1.28; n = 2585), and cerebrovascular disease (CeVD) (1.13; 95% CI 1.08, 1.18; n = 1945). For lung cancer, the excess relative rate (ERR) at 100 mGy (95% CI) was 0.01 (–0.10, 0.12; n = 652) among women, and –0.15 (–0.38, 0.07; n = 1002) among men based on a preferred model for men with lung doses <300 mGy. NMRD and non-Hodgkin lymphoma were not associated with estimated absorbed dose to the lung or TLN. Conclusions: There was little evidence that radiation increased the risk of lung cancer, suggesting that inhalation of uranium dust and the associated high-LET alpha particle exposure to lung tissue experienced over a few years is less effective in causing lung cancer than other types of exposures. There was no statistically significant difference in the lung cancer risk estimates between men and women. The elevation of certain causes of death such as CeVD is unexplained and will require additional scrutiny of workplace or lifestyle factors given that radiation is an unlikely contributor since only the lung and lymph nodes received appreciable dose.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Effects of Dose Error and Sample Size on Sonic Boom Dose-response Curves

NASA will soon be collecting noise-annoyance community survey data as the X-59 aircraft flies supersonically over several communities in the USA. Sparse measurements of the X-59 sonic thumps will be used together with physics-based simulations to estimate noise doses at survey participant locations. These dose estimates have associated error that affects the accuracy of modeled dose-response curves, which can result in misestimation of annoyance. The precision in dose-response curves is also a consideration in selecting the number of survey participants. To enable pretest studies of dose error and precision, simulated dose-response data were generated based on NASA’s Quiet Supersonic Flights 2018 test. The data included various degrees of dose error and sample size. Frequentist multilevel logistic regression models were fit to the true and perturbed dose-response data. Simple proportional relationships were identified between the model parameters and the perturbation standard deviation. The summary dose-response curves illustrate the impact on accuracy if dose error is not accounted for in the model. The precision in the dose-response curves is also shown as the number of participants and degree of participation is varied. Finally, sampling variability is illustrated by showing the dose-response curves for several replicates with random draws of participants and errors.

X-59↗

Effects of Dose Error and Sample Size on Sonic Boom Dose-Response Curves

NASA will soon be collecting noise-annoyance community survey data as the X-59 aircraft flies supersonically over several communities in the USA. Sparse measurements of the X-59 sonic thumps will be used together with physics-based simulations to estimate noise doses at survey participant locations. These dose estimates have associated error that affects the accuracy of modeled dose-response curves, which can result in misestimation of annoyance. The precision in dose-response curves is also a consideration in selecting the number of survey participants. To enable pretest studies of dose error and precision, simulated dose-response data were generated based on NASA’s Quiet Supersonic Flights 2018 test. The data included various degrees of dose error and sample size. Frequentist multilevel logistic regression models were fit to the true and perturbed dose-response data. Simple proportional relationships were identified between the model parameters and the perturbation standard deviation. The summary dose-response curves illustrate the impact on accuracy if dose error is not accounted for in the model. The precision in the dose-response curves is also shown as the number of participants and degree of participation is varied. Finally, sampling variability is illustrated by showing the dose-response curves for several replicates with random draws of participants and errors.

X-59↗