Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Digital Materials”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

EDX ClaiMM: Digital Resources for the Critical Minerals and Materials Community

Securing critical mineral supply chains is essential for transitioning to a clean energy economy and for maintaining national security. Big-data analytics can serve as a cost-effective means of identifying new domestic critical mineral resources but only if data can be easily located and digested. Using ArcGIS Enterprise Sites, EDX ClaiMM was developed to increase the accessibility of critical minerals data, reducing time spent on data collection and integration. Hosted tools provide rapid visualization and exploration of key datasets, unlocking insights to support resource assessments.

Yesenchak, Rachel↗

Evaluation of Computed Tomography Techniques for Material Identification in Low Level and Intermediate Level Waste - 16648

Measures required to assure long term safe storage of Low-level and intermediate-level short-lived (LIL/SL) waste generated by the nuclear-power industry in France include the characterization of the waste and identification of materials within the waste. Digital Radiography (DR) techniques using x-ray at energies in the 6 MeV range have been shown to be effective for validation of the integrity of the concrete containers, and it was considered that the use of this technique together with the addition of Computed Tomography (CT) techniques could effectively identify materials within the waste. This paper describes the initial evaluation of two DR imaging techniques and two CT techniques using x-ray energy spectra up to 9 MeV to inspect a surrogate waste package, which comprised an outer concrete cylindrical container of 1400 mm diameter with 148 mm wall thickness, and an overall volume of 2 meters cubed, within which a 200 liter drum containing representative heterogeneous inactive waste, was placed in the center and the annulus between the 200 liter drum and the outer cylindrical package was filled with cement grout. The surrogate waste within the 200 liter drum comprised three separate layers of high density, medium density and low density mixed materials. The equipment used was a linear accelerator producing high energy spectra at either 6 MeV or 9 MeV and a high-precision CT manipulator with X, Y, Z and rotation motions, which were common to all techniques investigated. Two different digital detectors were used in the DR and CT performance evaluations, a Digital Detector Array (DDA) comprising a columnar Thallium-doped Cesium-Iodide scintillator screen in intimate contact with a 2 k by 2 k array of amorphous silicon detectors, 200 μm x 200 μm in area, and a Linear Diode Array (LDA) comprising a line of Cadmium-Tungstate columns, 1 cm thick and 400 μm x 400 μm in area. The work comprised evaluations of linear accelerator spectra and the attenuation effects of the waste container and contents, image acquisition performance of each detector, and CT techniques using area detector and linear detector. The results presented in this paper include mathematical evaluation of the two CT techniques, and analysis of measurement data, digital images, CT reconstruction images, and estimated material densities. The data was compared with recorded details and photographs of the actual configuration of materials within the surrogate waste. The Digital Detector Array can generate CT inspection volumes with considerable resolution and detail for the low-density and medium-density sections of the surrogate waste, however, the high-density sections were not imaged with sufficient detail and the images contained a large number of artifacts mainly due to the detectors lack of high energy photon stopping power. Materials identification with the Digital Detector Array, while possible for certain materials, for materials in the steel to plastic density range the attenuation values of the voxels in the reconstruction are too similar and difficult to resolve from the artifacts present. The Linear Diode Array can generate CT inspection volumes of regions of interest of the low-density and medium-density sections with considerable resolution and contrast, and potentially acceptable levels of resolution and contrast of the high-density section of the waste. While a few artifacts were present in the reconstructions, the majority are not due to the fundamental properties of the detector and are considered to be correctable. Materials identification with the LDA inspection data appear to be viable, with steel, copper, and higher-density metals being readily be distinguished from other materials on the basis of voxel value. Future work is needed to obtain a better definition of optimum spatial resolution and inspection speed, and to develop a system of 'calibration rods' which would consist of a series of 50 mm diameter cylinders of 7 materials; Plastic, Teflon, Concrete, Aluminum, Copper, Tungsten and Lead. The cylinders will be distributed at a certain radius in the surrogate waste and will be used as reference points in the evaluation and demonstration of the contrastive performance for the low, medium and high-density cases. The ability to identify the materials within a sealed waste container, by nondestructive examination, enables the verification of waste acceptance criteria without the need to open the waste containers. This eliminates the need for complex and expensive equipment to open and remotely handle the intermediate level waste, avoids potential hazards and risk of personnel dose uptake, and does not increase the volume of waste caused by repackaging of materials after examination and the decontamination or disposal of equipment used.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optical Density Analysis of X-Rays Utilizing Calibration Tooling to Estimate Thickness of Parts

This process is designed to estimate the thickness change of a material through data analysis of a digitized version of an x-ray (or a digital x-ray) containing the material (with the thickness in question) and various tooling. Using this process, it is possible to estimate a material's thickness change in a region of the material or part that is thinner than the rest of the reference thickness. However, that same principle process can be used to determine the thickness change of material using a thinner region to determine thickening, or it can be used to develop contour plots of an entire part. Proper tooling must be used. An x-ray film with an S-shaped characteristic curve or a digital x-ray device with a product resulting in like characteristics is necessary. If a film exists with linear characteristics, this type of film would be ideal; however, at the time of this reporting, no such film has been known. Machined components (with known fractional thicknesses) of a like material (similar density) to that of the material to be measured are necessary. The machined components should have machined through-holes. For ease of use and better accuracy, the throughholes should be a size larger than 0.125 in. (.3 mm). Standard components for this use are known as penetrameters or image quality indicators. Also needed is standard x-ray equipment, if film is used in place of digital equipment, or x-ray digitization equipment with proven conversion properties. Typical x-ray digitization equipment is commonly used in the medical industry, and creates digital images of x-rays in DICOM format. It is recommended to scan the image in a 16-bit format. However, 12-bit and 8-bit resolutions are acceptable. Finally, x-ray analysis software that allows accurate digital image density calculations, such as Image-J freeware, is needed. The actual procedure requires the test article to be placed on the raw x-ray, ensuring the region of interest is aligned for perpendicular x-ray exposure capture. One or multiple machined components of like material/ density with known thicknesses are placed atop the part (preferably in a region of nominal and non-varying thickness) such that exposure of the combined part and machined component lay-up is captured on the x-ray. Depending on the accuracy required, the machined component fs thickness must be carefully chosen. Similarly, depending on the accuracy required, the lay-up must be exposed such that the regions of the x-ray to be analyzed have a density range between 1 and 4.5. After the exposure, the image is digitized, and the digital image can then be analyzed using the image analysis software.

Grau, David↗

FRAM v5.2 estimation of plutonium and uranium isotopics using digitized 3-D position-sensitive CdZnTe detectors

Gamma-ray spectroscopy is an important tool used in international safeguards to measure plutonium and uranium isotopics. Recently developed, digital, 3-D position-sensitive CdZnTe gamma-ray spectrometers are promising for safeguards, offering improved performance over commonly available CdZnTe systems, with energy resolutions approaching that of high-purity germanium. CdZnTe gamma-ray spectra from plutonium and uranium samples were processed using the commercially available software FRAM v5.2, a tool that estimates plutonium and uranium isotopics from high-purity germanium spectra, across a wide range of materials. Furthermore using digital CdZnTe systems 239 Pu/ 240 Pu isotopic composition and effective 240 Pu percentage are evaluated to within less than 3 sigma statistical measurement uncertainty across reactor to weapons-grade samples, while low and highly-enriched uranium are easily distinguished.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accelerating fissile material detection with a neutron source

A system discriminating fissile material from nonfissile material wherein a digital data acquisition unit collects data at high rate, and processes large volumes of data directly to count neutrons from the unknown source and detect excess grouped neutrons to identify fission. The system includes a Poisson neutron generator for in-beam interrogation of a possible fissile neutron source and inducing neutron emission therefrom, and a DC power supply that exhibits electrical ripple of less than one part per million. A neutron count histogram and Poisson count distribution are overlaid to provide a visual indication of the difference in correlation of natural and induced emitted neutrons from the radiation source to characterize the neutron source as fissile material or non-fissile material.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Accelerating fissile material detection with a neutron source

A method of discriminating fissile material from non-fissile material with a digital data acquisition system that collects data at high rate, and processes large volumes of data directly to count neutrons from the unknown source and detect excess grouped neutrons to identify fission. The system includes a Poisson neutron generator for in-beam interrogation of a possible fissile neutron source and inducing neutron emission therefrom, and a DC power supply that exhibits electrical ripple of less than one part per million. A neutron count histogram and Poisson count distribution are overlaid to provide a visual indication of the difference in correlation of natural and induced emitted neutrons from the radiation source to characterize the neutron source as fissile material or non-fissile material.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Grayscale Digital Light Processing Gradient Printing for Stress Concentration Reduction and Material Toughness Enhancement

Avoiding stress concentrations is essential to achieve robust parts since failure tends to originate at such concentrations. With recent advances in multimaterial additive manufacturing, it is possible to alter the stress (or strain) distribution by adjusting the material properties in selected locations. Here, we investigate the use of grayscale digital light processing (g-DLP) 3D printing to create modulus gradients around areas of high stress. These gradients prevent failure by redistributing high stresses (or strains) to the neighboring material. The improved material distributions are calculated using finite element analysis. The much-enhanced properties are demonstrated experimentally for thin plates with circular, triangular, and elliptical holes. In conclusion, this work suggests that multimaterial additive manufacturing techniques like g-DLP printing provide a unique opportunity to create tougher engineering materials and parts.

36 MATERIALS SCIENCE↗

The Porous Microstructure Analysis (PuMA) software

The open-source Porous Microstructure Analysis (PuMA) software was implemented to offer an efficient framework for determining material characteristics from 3D microstructures. Its development was inspired by progress in X-ray microtomography, an imaging technology that captures the internal structure of materials in 3D, and even in a 4D temporal context. Over recent years, this method has transformed the domain of materials science due to its capability to non-destructively examine material microstructures while presenting digital data about their geometrical details. It has provided insights into materials relevant to several NASA missions, including heatshields, parachute fabrics, meteorites, and other advanced composites. PuMA, in its current version 3, delivers an array of features, spanning from basic geometric insights of a microstructure to intricate anisotropic thermo-elastic and chemical behavior. Specifically, the software evaluates morphological attributes (specific surface area, volume fractions, mean intercept lengths, orientation) and physical characteristics (conductivity, elasticity, permeability, and tortuosity). Additionally, it can model material degradation processes, such as oxidation and surface chemistry interactions. The software can generate synthetic microstructures, from straightforward geometrical designs to intricate woven and non-woven geometries. Coupling material generation and characterization enable parametric studies and sensitivity analysis to optimize the microstructural performance and inform design decisions and reliability assessment based on uncertainty quantification. A recent addition to PuMA includes the TomoSAM plugin, devised to incorporate the cutting-edge Segment Anything Model (SAM). SAM is a promptable deep learning model that can identify objects and create image masks in a zero-shot manner, based only on a few user clicks. The synergy between these tools aids in the segmentation of complex 3D datasets from tomography or other imaging techniques, which would otherwise require a laborious manual segmentation process.

Tomography↗

The Porous Microstructure Analysis (PuMA) software

The open-source Porous Microstructure Analysis (PuMA) software was created to offer an efficient framework for determining material properties from 3D microstructures. Its development was inspired by progress in X-ray microtomography, an imaging technology that captures the internal structure of materials in 3D, and even in a 4D temporal context. Over recent years, this method has transformed the domain of materials science due to its capability to non-destructively examine material microstructures while presenting digital data about their geometrical details. It has provided insights into materials relevant to several NASA missions, including heatshields, parachute fabrics, meteorites, and other advanced composites. PuMA, in its current version 3, delivers an array of features, spanning from basic geometric insights of a microstructure to intricate anisotropic thermo-elastic and chemical behavior. Specifically, the software evaluates morphological attributes (specific surface area, volume fractions, mean intercept lengths, orientation) and physical characteristics (conductivity, elasticity, permeability, and tortuosity). Additionally, it can model material degradation processes, such as oxidation and surface chemistry interactions. The software can generate synthetic microstructures, from straightforward geometrical designs to intricate woven and non-woven geometries. Coupling material generation and characterization enables parametric studies and sensitivity analysis to optimize the microstructural performance and inform design decisions and reliability assessment based on uncertainty quantification. A recent addition to PuMA includes the TomoSAM plugin, devised to incorporate the cutting-edge Segment Anything Model (SAM) into our image segmentation workflow. SAM is a promptable deep learning model that can identify objects and create image masks in a zero-shot manner, based only on a few user clicks. The synergy between these tools aids in the segmentation of complex 3D datasets from tomography and other imaging techniques, which would otherwise require a laborious manual segmentation process.

Tomography↗

Example Work Domain Analysis for a Reference Sodium Fast Reactor

The nuclear industry is currently designing and building a new generation of reactors that will include different structural, functional, and environmental aspects, all of which are likely to have a significant impact on the way these plants are operated. In order to meet economic and safety objectives, these new reactors will all use advanced technologies to some extent, including new materials and advanced digital instrumentation and control systems. New technologies will affect not only operational strategies, but will also require a new approach to how functions are allocated to humans or machines to ensure optimal performance. Uncertainty about the effect of large scale changes in plant design will remain until sound technical bases are developed for new operational concepts and strategies. Up-to-date models and guidance are required for the development of operational concepts for complex socio-technical systems. This report describes how the classical Work Domain Analysis method was adapted to develop operational concept frameworks for new plants. This adaptation of the method is better able to deal with the uncertainty and incomplete information typical of first-of-a-kind designs. Practical examples are provided of the systematic application of the method in the operational analysis of sodium-cooled reactors. Insights from this application and its utility are reviewed and arguments for the formal adoption of Work Domain Analysis as a value-added part of the Systems Engineering process are presented.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Electronographic photometry of extended objects. I - Reduction procedures

Attention is given to the reduction of electronographic camera images obtained with the aid of the Kron camera. A description is given of the equipment used to digitize the plate material. The response of the camera-emulsion-microdensitometer system is discussed along with present system performance figures. An outline is presented of existing and future computer reduction techniques.

Benedict, G.↗

The critical satellite technical issues of future pervasive broadband low-cost communication networks

The critical technical issues of signal waveform design, projected spacecraft technology, satellite launch options, and satellite cost are discussed for future pervasive broadband communication networks. With DPCM video signal encoding, 32 Mb/s user-to-user data rate per channel, 10% overhead, two orthogonal polarizations, and crosstalk loss limited to 1 dB, TFM permits about 75 channels/GHz of frequency allocation. The BOM (beginning of mission) weight and power of a baseline 400-channel multibeam satellite is about 1800 kg and 5000 W. Each 35 Mb/s channel can support 1 to 10 video channels. The weight and power estimates assume hardened digital logic, composite materials for a multibeam antenna structure, high-efficiency solar cells, batteries, and amplifiers. Based on a cost model for large communication satellites, the total space segment cost of two active satellites and one spare would be about $485 M.

Harvey, R. L.↗

The outlook for advanced transport aircraft

The technological advances most likely to contribute to advanced aircraft designs and the efficiency, performance, and financial considerations driving the development directions for new aircraft are reviewed. Fuel-efficiency is perceived as the most critical factor for any new aircraft or component design, with most gains expected to come in areas of propulsion, aerodynamics, configurations, structural designs and materials, active controls, digital avionics, laminar flow control, and air-traffic control improvements. Any component area offers an efficiency improvement of 3-12%, with a maximum of 50% possible with a 4000 m range aircraft. Advanced turboprops have potential applications in short and medium haul subsonic aircraft, while a fuel efficient SST may be possible by the year 2000. Further discussion is devoted to the pivoted oblique wing aircraft, lightweight structures, and the necessity for short payback times.

Leavens, J. M., Jr.↗

Computer-Based Medical System

SYMED, Inc., developed a unique electronic medical records and information management system. The S2000 Medical Interactive Care System (MICS) incorporates both a comprehensive and interactive medical care support capability and an extensive array of digital medical reference materials in either text or high resolution graphic form. The system was designed, in cooperation with NASA, to improve the effectiveness and efficiency of physician practices. The S2000 is a MS (Microsoft) Windows based software product which combines electronic forms, medical documents, records management, and features a comprehensive medical information system for medical diagnostic support and treatment. SYMED, Inc. offers access to its medical systems to all companies seeking competitive advantages.

Source record↗

Accelerating fissile material detection with a neutron source

A neutron detector system for discriminating fissile material from non-fissile material wherein a digital data acquisition unit collects data at high rate, and in real-time processes large volumes of data directly to count neutrons from the unknown source and detecting excess grouped neutrons to identify fission in the unknown source. The system includes a Poisson neutron generator for in-beam interrogation of a possible fissile neutron source and a DC power supply that exhibits electrical ripple on the order of less than one part per million. Certain voltage multiplier circuits, such as Cockroft-Walton voltage multipliers, are used to enhance the effective of series resistor-inductor circuits components to reduce the ripple associated with traditional AC rectified, high voltage DC power supplies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accelerating fissile material detection with a neutron source

A neutron detector system for discriminating fissile material from non-fissile material wherein a digital data acquisition unit collects data at high rate, and in real-time processes large volumes of data directly to count neutrons from the unknown source and detecting excess grouped neutrons to identify fission in the unknown source. The system includes a Poisson neutron generator for in-beam interrogation of a possible fissile neutron source and a DC power supply that exhibits electrical ripple on the order of less than one part per million. Certain voltage multiplier circuits, such as Cockroft-Walton voltage multipliers, are used to enhance the effective of series resistor-inductor circuits components to reduce the ripple associated with traditional AC rectified, high voltage DC power supplies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ELASTOMERIC MICROVASCULAR SELF-HEALING MATERIALS

Damaged elastomeric diaphragms within pneumatic controllers used in the oil and gas industry lead to an unintended release of methane. Self-healing microvascular materials capable of healing various types of damage have been fabricated. These microvascular materials are designed to replace currently available commercial diaphragms found in pneumatic controllers and provide a solution to reduce unintended methane leaks. Poly(dimethylsiloxane) (PDMS) was used as the main matrix material, with additional testing conducted on polyurethane and flexibilised epoxy materials. Microvascular networks were implemented into the elastomeric membranes to act as ves- sels to deliver healing agents to the damaged areas. The complex, interdigitated channel networks were created using a 3D printed custom compounded filament composed of polylactic acid (PLA) and tin(II) oxalate. Two-part liquid casting polymers were poured around the channels into a mould to create samples with the scaffolding of the microvascular channels intact. Hollow microvascular networks were created by placing the samples within a vacuum oven at 250◦C which causes the thermal depolymerisation of PLA into its gaseous monomers. The manufactured materials were placed in test stands and pressurized using nitrogen gas to determine their healing and mechanical behaviour. Self-healing behaviour was demonstrated using PDMS matrix materials and healing chemistries within a pressure test cell. This test cell was designed to detect any damage to a sample by record- ing an outlet pressure. Damages including puncture holes, diagonal cuts and star-shaped central iv cuts were applied to the samples and a reduction in the outlet pressure was recorded for all sam- ples. A variation in channel spacing and diameter was studied to determine the optimal design of the microvascular network for self-healing performance. The mechanical performance of elastomeric membrane materials within a diaphragmatic pressurised stand was observed. Deformations and strains around the channels and channel inter- sections at the midplane of the materials were recorded using digital image correlation. Normal stresses were calculated using Hooke’s law and the material properties of the PDMS matrix. A reduction in leak rate, implying the success of self-healing, was recorded within manu- factured diaphragm samples tested within a commercial valve. PDMS is the favourable material when compared to polyurethane and flexibilised epoxy for creating

03 NATURAL GAS↗

Beyond Magic Barrels: Digital manufacturing for crystallization, process development and optimization of explosive materials: Part II Resveratrol Exemplar

This SAND report summarizes work supported by an Engineering Sciences Research Foundation (ESRF) Lab Directed Research and Development (LDRD) project entitled “Beyond Magic Barrels: Digital manufacturing for crystallization, process development and optimization of explosive materials.” This SAND report is written in two parts with Part 1 discusses recrystallization of our explosive exemplar and Part 2 summarizing our work with recrystallization of resveratrol. We have studied resveratrol recrystallization with a multiscale approach combining experiments, modeling and simulation. At the single crystal scale, microscopy experiments illuminate crystal time-dependent growth rates using advanced image analysis. Bench scale experiments were carried out to look at growth of multiple particles in a small reactor creating thousands of particles and analyzing the results with microscopy and μCT. For the modeling we combine kinetic Monte Carlo (kMC) models with subscale information from density functional theory (DFT) or molecular dynamics. This work is discussed in Part 1 and can also be found in a paper from the project discussing a coarse-grained kMC model specifically developed for resveratrol. For well-mixed systems, we have population balance equations (PBE) linked with species mass conservation forming a set of ordinary differential equations that can be solved quickly. For more complicated geometries, such as the vat crystallization used throughout the complex, a coupled computational fluid dynamic (CFD)/PBE method was developed to account for gradients in temperature and concentration and differences in crystallization rates throughout the domain. These simulations are more complex and require high performance computing. We present results for two cases: 5% seed fast cool with parameters fit to the well-mixed case and 5% seed slow cool using the same parameters. We show reasonable agreement with experiments though are particles are significantly larger than the experiments.

36 MATERIALS SCIENCE↗