Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Advanced Radiation Detectors and Detector Systems Research

Real‐time awareness of space radiation is critical for missions beyond LEO. Missions to the Moon, Mars, Near‐Earth‐Objects (NEOs), inner and outer planets, as well as other destinations in space, will require embedded instrumentation to provide feedback for “smart”, adaptive control systems. Precision instrumentation will also be needed to provide improved data for space radiation modeling and space weather forecasting and awareness. Compact instrumentation on small platforms such as CubeSats and other small space‐faring vehicles will provide a better understanding of the space radiation environment by supplying data from multiple locations in space where information is yet unknown. Compact integrable solid‐state detectors with low noise and high tolerance of operation in a radiation environment are enabled by the application of Wide Band Gap semiconductors as radiation detectors. NASA Glenn Research Center (GRC) is applying its expertise and facilities in harsh environment instrumentation to develop supporting technologies that enable improved instruments for space science missions. A variety of radiation detectors are under development, such as silicon carbide semiconductor detectors, for applications to space science, lunar prospecting, and fission power systems.

Field and particle detectors↗

Detector Characterization for Quantitative Spectral Radiography of Uranium Powder Samples

Pacific Northwest National Laboratory (PNNL) is developing a prototype spectral x-ray radiography (SpecX) non-destructive assay system for noninvasive material mass quantification of uranium-bearing powders. The SpecX system uses a custom material estimation algorithm, which requires a high-fidelity pixel-by-pixel detector response model for accurate quantification. We performed a detailed characterization and built a model of a High-Energy X-ray Imaging Technology (HEXITEC) CdTe pixelated spectral detector. Here we present the detector characterization which led to that model, including a determination of the pixel-wise energy calibration, the detection efficiency, the detector uniformity, the detector stability, and a comparison of methods to remove charge-shared events.

spectral X-ray radiography, pixelated detector, ca↗

Comparative study of ionization chamber detectors vis-a-vis a CCD detector for dispersive XAS measurement in transmission geometry

We have designed and fabricated parallel plate ionization chamber detectors and voltage vs. current characteristics (V-I curve) of the detectors were recorded with synchrotron radiation to qualify for use in X-ray Absorption Spectroscopy (XAS) measurements. After qualifying the ionization chambers, the detectors were used in the dispersive EXAFS beamline (BL-08) at INDUS-2 SRS in Turbo-XAS geometry. Using the same setup and under the same setting, XAS spectra were also recorded with a CCD detector and the observation on relative performance of the ionization chamber vis-a-vis the CCD detector is presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Present status of sensitive detector of reactor’s antineutrinos using scintillating detectors

In 2011, the reanalysis of the reactor antineutrinos spectra led to the formulation of the Reactor Antineutrino Anomaly (RAA) [1], which indicates the discrepancy between measured and expected antineutrino fluxes on short baselines. This discrepancy appears to favor the existence of the fourth “sterile” neutrino with |Δm{sup 2}|>1 eV{sup 2}. To confirm or reject this hypothesis a high sensitive antineutrino detector located close to the reactor is required. In addition to that such a detector could be used to online monitor the isotopic composition of the reactor core and to prevent illegal production and removal of{sup 239}Pu, which is the essential part of nuclear weapons. Detector DANSSino [2] already proved that even a compact antineutrino detector (∼ 1 m{sup 3}) based on polystyrene is capable of antineutrino detection in the close vicinity of a reactor core (∼ 10 m) with signal to background ratio about one. As a common activity between JINR Dubna and IEAP CTU a new prototype of detector (called S{sup 3}) has been proposed and is under construction. The construction design, selected results of Monte Carlo simulations and results of benchmark tests are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recovery of coincident frequency domain multiplexed detector pulses using sequential deconvolution

Multiplexing of radiation detector signals into a single channel significantly reduces the need for a large number of digitizer channels, which reduces the cost and the power consumption of a data acquisition system. We previously demonstrated frequency domain multiplexing by convolution using a prototype system that multiplexed two EJ-309 organic scintillators signals into a single channel. Each detector pulse was converted to a damped sinusoid which was then combined into a single channel. The combined signal was digitized and the original detector signal was recovered from the damped sinusoid by deconvolution. In this paper, we demonstrate the recovery of multiple detector signals that arrive during the same digitized record via a new sequential deconvolution method. Here, when two detectors produce signals in the same digitized record and their pulses do not overlap in time, we found that the charge, arrival time, and particle type can be estimated fairly precisely for the first pulse, but the second pulse exhibits substantial degradation in the precision of the estimated charge and arrival time. When the pulses overlap in time, we demonstrate both theoretically and experimentally that the part of the first pulse that does not overlap with the second can be recovered accurately, so the arrival time and amplitude of the first pulse can be estimated fairly precisely, but not the charge or particle type. None of these quantities can be estimated precisely for the second pulse when the two pulses overlap.

47 OTHER INSTRUMENTATION↗

Setting the threshold for high throughput detectors: A mathematical approach for ensembles of dynamic, heterogeneous, probabilistic anomaly detectors

Cyber operations now manage a high volume of heterogeneous log data. Anomaly Detection (AD) in such operations involves multiple (e.g., per IP, per data type) ensembles of detectors modeling heterogeneous characteristics (e.g., rate, size, type) often with adaptive online models producing alerts in near real time. Because of the high data volume, setting the threshold for each detector in such a system is an essential yet underdeveloped configuration issue that, if slightly mistuned, can leave the system useless, either producing a myriad of alerts (and flooding downstream systems) or giving none. In this work, we build on the foundations of Ferragut et al. to provide a set of rigorous results for understanding the relationship between threshold values and alert quantities for probabilistic detectors. This informs an algorithm for setting the threshold of multiple, heterogeneous, possibly dynamic detectors completely a priori, in principle. Indeed, if the underlying distribution of the incoming data is known, the algorithm provides provably manageable thresholds. If the distribution is unknown (poorly estimated), our analysis gives insight into how the model distribution differs from the actual distribution, indicating refitting is necessary. We provide empirical experiments, regulating the alert rate of a system with ≈2,500 adaptive detectors scoring over 1.5M events in 5 hours of timestamps. Further, we demonstrate on real network data and detection framework of Harshaw et al. the alternative case, demonstrating that the inability to regulate alerts indicates how the detection model is not a good fit to the data.

Bridges, Robert↗

Novel Light Detectors for Directional MeV scale DM Detectors

The search for sub-GeV dark matter requires novel detector development due to the small expected ionization signal and large backgrounds, many of which still need to be well-modeled. For this reason, to unambiguously detect dark matter, a detector must be able to determine the directionality of the incoming particles so that the daily modulation of the rate can be used to confirm a dark matter signal. This can be accomplished by combining anisotropic scintillating crystals, such as trans-Stilbene, as a detector target, with an optically-sensitive Skipper CCD as a readout. I will present on my work over the past six months developing the first prototype of this detector, including optical testing of the trans-Stilbene and design of the detector. This work will lead to characterization of the CCDs and deployment of the first prototype later this year.

Hoch, Nora [MIT]↗

Charged Particle Induced Radiation damage of Germanium Detectors in Space: Two Mars Observer Gamma-Ray Detectors

The Mars Observer Gamma-Ray Spectrometer (MO GRS) was designed to measure gamma-rays emitted by the Martian surface. This gamma-ray emission is induced by energetic cosmic-ray particles penetrating the Martian surface and producing many secondary particles and gamma rays. The MO GRS consisted of an high-purity germanium (HPGe) detector with a passive cooler. Since radiation damage due to permanent bombardment of energetic cosmic ray particles (with energies up to several GeV) was expected for the MO GRS HPGe crystal, studies on radiation damage effects of HPGe crystals were carried on earth. One of the HPGe crystals (paradoxically called FLIGHT) was similar to the MO GRS crystal. Both detectors, MO GRS and FLIGHT, contained closed-end coaxial n-type HPGe crystals and had the same geometrical dimensions (5.6 x 5.6 cm). Many other parameters, such as HV and operation temperature, differed in space and on earth, which made it somewhat difficult to directly compare the performance of both detector systems. But among other detectors, detector FLIGHT provided many useful data to better understand radiation damage effects.

Bruekner, J.↗

Calibration Improvements in the Detector-to-Detector Differences for the MODIS Ocean Color Bands

The Moderate Resolution Imaging Spectroradiometer (MODIS), a major instrument within NASAs Earth Observation System missions, has operated for over 16 and 14 years onboard the Terra and Aqua satellites, respectively. Its reflective solar bands (RSB) covering a spectral range from 0.4 to 2.1 micrometers are primarily calibrated using the on-board solar diffuser(SD), with its on-orbit degradation monitored using the Solar Diffuser Stability Monitor. RSB calibrations are supplemented by near-monthly lunar measurements acquired from the instruments space-view port. Nine bands (bands 8-16) in the visible to near infrared spectral range from 0.412 to 0.866 micrometers are primarily used for ocean color observations.During a recent reprocessing of ocean color products, performed by the NASA Ocean Biology Processing Group, detector-to-detector differences of up to 1.5% were observed in bands 13-16 of Terra MODIS. This paper provides an overview of the current approach to characterize the MODIS detector-to-detector differences. An alternative methodology was developed to mitigate the observed impacts for bands 13-16. The results indicated an improvement in the detector residuals and in turn are expected to improve the MODIS ocean color products. This paper also discusses the limitations,subsequent enhancements, and the improvements planned for future MODIS calibration collections.

Li, Yonghong↗

Fabrication of Detector Arrays for the SPT-3G Receiver

The South Pole Telescope third-generation (SPT-3G) receiver was installed during the austral summer of 2016–2017. It is designed to measure the cosmic microwave background across three frequency bands centered at 95, 150, and 220 GHz. The SPT-3G receiver has ten focal plane modules, each with 269 pixels. Each pixel features a broadband sinuous antenna coupled to a niobium microstrip transmission line. In-line filters define the desired band-passes before the signal is coupled to six bolometers with Ti/Au/Ti/Au transition edge sensors (three bands × two polarizations). In total, the SPT-3G receiver is composed of 16,000 detectors, which are read out using a 68 × frequency-domain multiplexing scheme. In this paper, we present the process employed in fabricating the detector arrays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Special Nuclear Material Characterization Using Digital 3-D Position Sensitive CdZnTe Detectors and High Purity Germanium Spectrometers

Special nuclear material (SNM) monitoring often requires high resolution gamma-ray spectroscopy for material characterization. Portable systems and rapid deployment are also highly valued for some applications. Deployable gamma-ray imaging spectrometers using pixelated CdZnTe semiconductor detectors have become commercially available within the past three years to meet these requirements. CdZnTe systems have demonstrated room-temperature energy resolutions below 0.5% FWHM at 662 keV using single pixel events and below 0.7% FWHM at 662 keV using all events. The systems are able to go from storage to measurement in less than two minutes. Special nuclear materials were measured at the Y-12 National Security Complex and at the Device Assembly Facility at the Nevada National Security Site. The use of a CdZnTe system to measure uranium enrichment was demonstrated and uranium spectral features were compared to a commercially available high purity germanium (HPGe) spectrometer. The use of passive gamma ray spectroscopy techniques to estimate plutonium grade using CdZnTe detectors was demonstrated for the first time.

CdZnTe detectors, gamma-ray imaging, gamma-ray spe↗

Muon Borehole Detector Design for Use in 4-D Density Overburden Monitoring

The increase of atmospheric CO2 concentrations has initiated research into carbon sequestration methods. One possibility is to store CO2 in subsurface porous reservoirs. The monitoring of the injected CO2 plume is vital because escaping CO2 poses health and environmental risks. Typically, seismic reflection methods are used to determine the change in density due to the replacement of brine by CO2 in the reservoir, but this is expensive and not continuous. A potential alternative is to use cosmic muon tomography to measure density changes in the reservoir as a function of time. This paper describes the development of a muon detector that will be capable of being deployed in boreholes. The detector has the required dimensions, an angular resolution of approximately 2 degrees, and is robust. The design is based on alternating layers of scintillating rods, which can provide 4-D tomographic data to detect small changes in density at depths up to approximately 2 km. Geant4, a Monte Carlo simulation code, is being used to develop models to guide the design of the physical configuration. Preliminary testing and measurements have been performed to validate the simulation predictions and optimize the performance of the system. The simulation and preliminary experimental results are presented here.

Borehole Detector, CO¬2 Sequestration, Geant4, Muo↗

Assessment of SNPP VIIRS RSB detector-to-detector differences using deep convective clouds and deserts

An accurate on-orbit characterization of the Visible Infrared Imaging Radiometer Suite (VIIRS) onboard the Suomi National Polar-orbiting Partnership satellite is essential to satisfy the requirements from NOAA, NASA, and the general research community for high-quality operational and research products. NASA’s Land Science Investigator-led Processing System (LSIPS) sensor data records (SDRs) are utilized to assess the stability of the calibrated top of atmosphere reflectance over the deep convective clouds (DCCs) and over the Libya-4desert site. The results from DCCs and desert show detector-to-detector (D2D) reflectance differences in the VIIRS reflective solar bands, 10 moderate-resolution bands (M-bands, M1to M5, M7 to M11), and three imagery resolution bands (I-bands, I1-I3). More importantly, the D2D differences exhibit an increase in magnitude over time for bands M1 to M5 and I1to I2, which induces noticeable striping and higher uncertainties in the downstream data products. The largest D2D difference is observed in bands M1 and M2, with magnitudes greater than1.8% in trends among the 16 detectors and standard deviations less than 0.12% over time. TheD2D stability assessment results over DCCs are consistent with those observed over the Libya-4desert site. To improve the quality of the calibrated SDR reflectance data, NASA’s VIIRS characterization support team has improved the calibration algorithm to incorporate corrections based on these DCC measurements to mitigate the striping (detector differences) observed in the current version of the SDR. These improvements are planned to be included in the next mission reprocessing of the LSIPS land products.

SNPP VIIRS↗

Cesium lead bromide semiconductor radiation detectors: crystal growth, detector performance and polarization

Cesium lead bromide (CsPbBr 3 ) is an upcoming semiconductor radiation detector that has the potential to match the detection properties of cadmium zinc telluride (CZT) and thallium bromide (TlBr). In this paper, we report on CsPbBr 3 gamma detectors with an uncorrected energy resolution of 2% at 662 keV with photopeak-to-Compton ratios as high as 14.3 and hole mobility-lifetime products (μτ h ) as high as 1.7 × 10 –2 cm 2 V –1 . Furthermore, we demonstrate that the processes employed for material purification and crystal growth of high-performing devices are scalable, and large (up to 65 mm in diameter) ultrahigh purity CsPbBr 3 crystals have been successfully grown. Furthermore by using optimized growth conditions and detector fabrication processes, we were able to mitigate the polarization problem where it was revealed that the polarization process is highly dependent on the crystal quality and the electric field direction with respect to the orientation of the crystal.

30 DIRECT ENERGY CONVERSION↗

Cryogenic gamma detectors enable direct detection of 236 U and minor actinides for non-destructive assay [Cryogenic gamma detectors enable direct detection of minor actinides for non-destructive assay]

Here, we demonstrate the utility of a superconducting transition edge sensor (TES) γ-ray detector with high energy resolution and low Compton background for non-destructive assay (NDA) of a uranium sample from reprocessed nuclear fuel. We show that TES γ-detectors can separate low energy actinide γ-emissions from the background and nearby lines, even from minor isotopes whose signals are often obscured in NDA with conventional Ge detectors. Superconducting γ detectors may therefore bridge the gap between high-accuracy destructive assay (DA) and easier to-use NDA.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗