Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector Response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Comparison of Simulated and Experimentally Measured Detector Impulse Responses to Pulsed X-rays

The Gamma Array Simulation Toolkit (GAST) is a multi-physics software stack comprised of Geant4, MATLAB, and experimentally measured photomultiplier tube (PMT) impulse response waveforms that is used to model and inform the end-to-end performance of radiation detector systems. In order to validate the ability of GAST to predict the impulse response of a modeled detector configuration operated in current mode, experimental measurements using the Nevada National Security Site Transformational Diagnostics and Imaging 2 MeV endpoint energy electron linear accelerator (linac) with a tungsten target were performed. Seven different detector configurations consisting of unique combinations of scintillator material, size, reflectivity conditions, presence or absence of light guide, and PMT were evaluated. The resultant impulse response of each detector configuration was recorded and compared to a GAST simulation that emulated the respective linac experiment conditions. The comparison of the experimental and simulated detector impulse responses indicated that GAST can reliably predict detector impulse responses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulations of Events for the LUX-ZEPLIN (LZ) Dark Matter Experiment

The LUX-ZEPLIN dark matter search aims to achieve a sensitivity to the WIMP-nucleon spin-independent cross-section down to (1–2) ×10−12 pb at a WIMP mass of 40 GeV/ c 2 . This paper describes the simulations framework that, along with radioactivity measurements, was used to support this projection, and also to provide mock data for validating reconstruction and analysis software. Of particular note are the event generators, which allow us to model the background radiation, and the detector response physics used in the production of raw signals, which can be converted into digitized waveforms similar to data from the operational detector. Inclusion of the detector response allows us to process simulated data using the same analysis routines as developed to process the experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-548: An Extraction Method for Correction of Detector Volume Effect in Small Field Profile Measurement

Purpose: To investigate the appropriateness of Gaussian detector response function in SRS profile measurement. Methods: In-air profile data for a 6MV beam were collected by using ionization chambers and radiochromic film. Two ionization chambers (FC65-G(IBA) and PinPoint(PTWTW31009)) were used to scan the beam profile. Film was used to measure the beam penumbra. A half-blocked beam was acquired with stepping size of 0.2mm and gradient of the measured profile represents the detector response function. The field widths of 2cm and 3cm were measured at SAD. Two detector response functions were evaluated, i.e. a traditional single Gaussian and a three-Gaussian symmetric function. Two corresponding models were used to fit measured data. One was error functions with one shaping parameter. The other model was a symmetrical superposition of three sets of error functions with fixed separation and two different shaping parameters. In both fitting, resultant Gaussian kernels and corresponding σs could be calculated analytically. SNR of the fitted curves were obtained and compared. Results: Our measured data indicated that the ionization chambers had a three-peak response function. From the first modeling, SNR for FC65-G were 36.0dB and 38.3dB for 2cm and 3cm field respectively. The corresponding SNR for the PinPoint were 43.6dB and 42.5dB. From the second modeling, SNR for FC65-G were 42.5dB and 47.4dB for 2cm and 3cm field respectively. The corresponding SNR for the PinPoint were 44.0dB and 44.5 dB. Three-gaussian model had an observable improvement for FC65-G chamber. Film measured penumbra was 3–5 times smaller than that of ionization-chambers. Conclusion: Superposition of three Gaussian kernels resembles the detector response due to central electrode and chamber wall and results in a better fitting to the measurement data than a single Gaussian kernel. Our study indicated that the Three-Gaussian model was more suitable for the detector with sigma comparable to penumbra width.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-EF-207-11: Energy and Depth Response of Thermoluminescent Dosimeters and Ionization Chambers in Water for Kilovoltage X-Ray Beams

Purpose: To assess the effects of changes in beam quality on detector response in the kilovoltage energy range by modulating the x-ray tube voltage and the measurement depth in water. Methods: Measurements were performed with TLD-100 and TLD-100H thermoluminescent dosimeters and an A12 farmer-type ionization chamber. To assess the energy response of the detectors, irradiations were performed at a depth of 3 cm in a custom-built thin-window water phantom using the moderately filtered x-ray beams at the UWADCL (20 kVp-250 kVp) and a Co-60 beam.The x-ray beams and detectors were modeled using the EGSnrc Monte Carlo code. The model was validated by simulating dose to the collecting volume of an A12 farmer chamber and comparing it with measured A12 signal as a function of depth. Dose was tallied to each detector and to water for comparison with measurements. Simulations were used to calculate the predicted energy response, which was compared to the measured response of each detector. Dose to each detector and dose to water as a function of depth were also simulated. Results: Detector output per dose to water was found to deviate by up to 15%, 20% and 30% as a function of energy relative to Co-60 for the A12, TLD-100H and TLD-100, respectively. The EGSnrc simulations produced results similar to the measurements for ionization chambers, but discrepancies of up to 30% were observed for TLD-100H. Simulated detector response as a function of depth was found to vary by up to 3%. Conclusion: These results suggest that changes in beam quality in kilovoltage x-ray beams can have a significant impact on detector response. In-water detector response was found to differ from the previously investigated in-air response. Deviations in detector response as a function of depth were less significant, but could potentially cause dosimetric errors if ignored.

60 APPLIED LIFE SCIENCES↗

Directional Unfolded Source Term (DUST) for Compton Cameras.

A Directional Unfolded Source Term (DUST) algorithm was developed to enable improved spectral analysis capabilities using data collected by Compton cameras. Achieving this objective required modification of the detector response function in the Gamma Detector Response and Analysis Software (GADRAS). Experimental data that were collected in support of this work include measurements of calibration sources at a range of separation distances and cylindrical depleted uranium castings.

47 OTHER INSTRUMENTATION↗

GADRAS-DRF Enhancements for Safeguards – Custom Peak Fitting to Enhance Model Fitting and Isotopics

One major software update was accomplished within the Gamma Detector Response and Analysis Software-Detector Response Function (GADRAS-DRF) package. This update allows users to adjust individual peak fits for use in subsequent analysis processes within GADRAS-DRF. A graphical user interface (GUI) was implemented so users can see the effect of their fit adjustments on the spectrum. This new feature will enhance the capability of the previously funded auto-enrichment and peak-based 1D model fit feature that was implemented in FY23 (Fiscal Year). Isotopic analysis was performed using M400 data obtained from uranium standards and the isotopic assessment is given with and without manual peak adjustments.

07 ISOTOPE AND RADIATION SOURCES↗

GADRAS-DRF Validation for Safeguards and Custom Peak Fit Enhancements

In previous years, SGTech funded enhancements to the isotopics routine in the software called Gamma Detector Response and Analysis Software-Detector Response Function (GADRAS-DRF), including the addition of peak fit customization capabilities. A project was also funded that focused on implementing a peak-based model fitting routine, allowing model fitting to be performed without dependence on export-controlled cross-sections. In FY25 significant improvements were made to the custom peak fitting interface, accompanied by several validation studies within GADRAS-DRF. These studies encompassed IsotopeID performance, distributed source analysis, isotopics validation, and activity estimation. Additionally, the peak-only model fitting option was validated using an HPGe measurement of a rotating drum with line sources.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dosimetric characterization of a microDiamond detector in clinical scanned carbon ion beams

Purpose: To investigate for the first time the dosimetric properties of a new commercial synthetic diamond detector (PTW microDiamond) in high-energy scanned clinical carbon ion beams generated by a synchrotron at the CNAO facility. Methods: The detector response was evaluated in a water phantom with actively scanned carbon ion beams ranging from 115 to 380 MeV/u (30–250 mm Bragg peak depth in water). Homogeneous square fields of 3 × 3 and 6 × 6 cm{sup 2} were used. Short- and medium-term (2 months) detector response stability, dependence on beam energy as well as ion type (carbon ions and protons), linearity with dose, and directional and dose-rate dependence were investigated. The depth dose curve of a 280 MeV/u carbon ion beam, scanned over a 3 × 3 cm{sup 2} area, was measured with the microDiamond detector and compared to that measured using a PTW Advanced Markus ionization chamber, and also simulated using FLUKA Monte Carlo code. The detector response in two spread-out-Bragg-peaks (SOBPs), respectively, centered at 9 and 21 cm depths in water and calculated using the treatment planning system (TPS) used at CNAO, was measured. Results: A negligible drift of detector sensitivity within the experimental session was seen, indicating that no detector preirradiation was needed. Short-term response reproducibility around 1% (1 standard deviation) was found. Only 2% maximum variation of microDiamond sensitivity was observed among all the evaluated proton and carbon ion beam energies. The detector response showed a good linear behavior. Detector sensitivity was found to be dose-rate independent, with a variation below 1.3% in the evaluated dose-rate range. A very good agreement between measured and simulated Bragg curves with both microDiamond and Advanced Markus chamber was found, showing a negligible LET dependence of the tested detector. A depth dose curve was also measured by positioning the microDiamond with its main axis oriented orthogonally to the beam direction. A strong distortion in Bragg peak measurement was observed, confirming manufacturer recommendation on avoiding such configuration. Very good results were obtained for SOBP measurements, with a difference below 1% between measured and TPS-calculated doses. The stability of detector sensitivity in the observation period was within the experimental uncertainty. Conclusions: Dosimetric characterization of a PTW microDiamond detector in high-energy scanned carbon ion beams was performed. The results of the present study showed that this detector is suitable for dosimetry of clinical carbon ion beams, with a negligible LET and dose-rate dependence.

07 ISOTOPE AND RADIATION SOURCES↗

TU-F-18A-04: Use of An Image-Based Material-Decomposition Algorithm for Multi-Energy CT to Determine Basis Material Densities

Purpose: Published methods for image-based material decomposition with multi-energy CT images have required the assumption of volume conservation or accurate knowledge of the x-ray spectra and detector response. The purpose of this work was to develop an image-based material-decomposition algorithm that can overcome these limitations. Methods: An image-based material decomposition algorithm was developed that requires only mass conservation (rather than volume conservation). With this method, using multi-energy CT measurements made with n=4 energy bins, the mass density of each basis material and of the mixture can be determined without knowledge of the tube spectra and detector response. A digital phantom containing 12 samples of mixtures from water, calcium, iron, and iodine was used in the simulation (Siemens DRASIM). The calibration was performed by using pure materials at each energy bin. The accuracy of the technique was evaluated in noise-free and noisy data under the assumption of an ideal photon-counting detector. Results: Basis material densities can be estimated accurately by either theoretic calculation or calibration with known pure materials. The calibration approach requires no prior information about the spectra and detector response. Regression analysis of theoretical values versus estimated values results in excellent agreement for both noise-free and noisy data. For the calibration approach, the R-square values are 0.9960+/−0.0025 and 0.9476+/−0.0363 for noise-free and noisy data, respectively. Conclusion: From multi-energy CT images with n=4 energy bins, the developed image-based material decomposition method accurately estimated 4 basis material density (3 without k-edge and 1 with in the range of the simulated energy bins) even without any prior information about spectra and detector response. This method is applicable to mixtures of solutions and dissolvable materials, where volume conservation assumptions do not apply. CHM receives research support from NIH and Siemens Healthcare.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ISO Key Project: Exploring the full range of QUASAR/AGN properties

The PIA (PHOT Interactive Analysis) software was upgraded as new releases were made available by VILSPA. We have continued to analyze our data but, given the large number of still outstanding problems with the calibration and analysis (listed below), we remain unable to move forward on our scientific program. We have concentrated on observations with long (256 sec) exposure times to avoid the most extreme detector responsivity drift problems which occur with a change in observed flux level, ie. as one begins to observe a new target. There remain a significant number of problems with analyzing these data including: (1) the default calibration source (FCS) observations early in the mission were too short and affected by strong detector responsivity drifts; (2) the calibration of the FCS sources is not yet well-understood, particularly for chopped observations (which includes most of ours); (3) the detector responsivity drift is not well-understood and models are only now becoming available for fitting chopped data; (4) charged particle hits on the detector cause transient responsivity drifts which need to be corrected; (5) the "flat-field" calibration of the long-wavelength (array) detectors: C1OO, C200 leaves significant residual structure and so needs to be improved;(6) the vignetting correction, which affects detected flux levels in the array detectors, is not yet available; (7) the intra-filter calibrations are not yet available; and (8) the background above 60 microns has a significant gradient which results in spurious positive and negative "detections" in chopped observations. ISO Observation planning, conferences and talks, ground based observing and other grant related activities are also briefly discussed.

Wilkes, B.↗

DetSuM: Detector Surrogate Model for LArTPC

In large neutrino experiments such as the Deep Underground Neutrino Experiment (DUNE), estimating detector response uncertainties typically requires simulation samples that consume substantial computing resources and time. To mitigate this challenge, we present DetSuM, an uncertainty-aware surrogate model designed to capture the detector response variations with reduced computing load compared to full simulations. This poster describes the construction and evaluation of DetSuM using simulation and reconstruction datasets in a rare-event search at DUNE. We assess DetSuM's ability to predict key detector-response variations and their associated uncertainties, discuss current limitations, and outline improvements to extend its validity in systematics studies of DUNE physics.

Li, Aobo [UC, San Diego]↗

Sensitivity Analysis of Neutron Multiplicity Counting Statistics Using First-Order Perturbation Theory and Application to a Subcritical Plutonium Metal Benchmark

It is frequently important to estimate the uncertainty and sensitivity of measured and computed detector responses in subcritical experiments and simulations. These uncertainties arise from the physical construction of the experiment, uncertainties in the transport parameters, and counting uncertainties. Perturbation theory enables sensitivity analysis (SA) and uncertainty quantification on integral quantities like detector responses. Here the aim of our work is to apply SA to the statistics of subcritical neutron multiplicity counting distributions. Current SA methods have only been applied to mean detector responses and the keff eigenvalue. For multiplicity counting experiments, knowledge of the higher-order counting moments and their uncertainties are essential for a complete SA. We apply perturbation theory to compute the sensitivity of neutron multiplicity counting moments to arbitrarily high order. Each moment is determined by solving an adjoint transport equation with a source term that is a function of the adjoint solutions for lower-order moments. This enables moments of arbitrarily high order to be sequentially determined, and it shows that each moment is sensitive to the uncertainties of all lower-order moments. To close our SA of the moments, we derive forward transport equations that are functions of the forward flux and lower-order moment adjoint fluxes. We verify our calculations for the first three moments by comparison with multiplicity counting measurements of a subcritical plutonium metal sphere. For the first three moments, the most influential parameters are ranked, and the validity of first-order perturbation theory is demonstrated by examining the series truncation error. This enables a detailed SA of subcritical multiplicity counting measurements of fissionable material based on transport theory.

42 ENGINEERING↗

Neutron Fluence and Energy Reconstruction with the LNE-IRSN/MIMAC Recoil Detector MicroTPC at 27 keV

The French Institute for Radiation protection and Nuclear Safety (IRSN), designated by the French Metrology Institute (LNE) for neutron metrology, is developing a time projection chamber using a Micromegas anode: microTPC. This work is carried out in collaboration with the Laboratory of Subatomic Physics and Cosmology (LPSC). The aim is to characterize the energy distribution of neutron fluence in the energy range 8 keV - 5 MeV with a primary procedure. The time projection chambers are gaseous detectors able to measure charged particles energy and to reconstruct their track if a pixelated anode is used. In our case, the gas is used as a (n, p) converter in order to detect neutrons down to few keV. Coming from elastic collisions with neutrons, recoil protons lose a part of their kinetic energy by ionizing the gas. The ionization electrons are drifted toward a pixelated anode (2D projection), read at 50 MHz by a self-triggered electronic system to obtain the third track dimension. The neutron energy is reconstructed event by event thanks to proton scattering angle and proton energy measurements. The scattering angle is deduced from the 3D track. The proton energy is obtained by charge collection measurements, knowing the ionization quenching factor (i.e. the part of proton kinetic energy lost by ionizing the gas). The fluence is calculated thanks to the detected events number and the simulation of the detector response. The μTPC is a new reliable detector able to measure energy distribution of the neutron fluence without unfolding procedure or prior neutron calibration contrary to usual gaseous counters. The microTPC is still being developed and measurements have been carried out at the AMANDE facility, with neutrons energies going from 8 keV to 565 keV. After the context and the μ-TPC working principle presentation, measurements of the neutron energy and fluence at 27 keV and 144 keV are shown and compared to the complete detector response simulation. This work shows the first direct reconstruction of neutron energy and fluence, simultaneously, at 27.2 keV in a continuous irradiation mode. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and validation of a gamma-ray detection response model for neutron-diagnosed subcritical experiments

In a neutron-diagnosed subcritical experiment, a highly sensitive and fast detector is required to accurately determine the true fission γ-ray emission rate from an object composed of special nuclear material under interrogation, in addition to a proper detector response model for use in forward modeling. We present the development of a detector response model that is based in GEANT4 and uses post-processing techniques to include photomultiplier tube time and pulse height response effects. We also define a set of detector performance evaluation metrics that emphasized our experimental objectives. A suite of time and pulse height response measurements for several diverse detector assemblies are described. These assemblies were simulated with this response model and benchmarked against the laboratory measurements. This response model reproduces the pulse height curve shapes and performance hierarchy of the measured detectors well. Additionally, the simulated time response curves exhibit reasonable agreement with counterpart measurements. These measurements and simulation results together suggest that a large volume EJ-299-49 plastic scintillator that is mated to an ultraviolet transmitting plastic light guide and relies on total internal reflection for light transport to the photocathode will provide significantly faster timing, increase pulse height by a factor of 3, and require 25% less γ rays to meet experimental needs, compared to the candidate detector design developed prior to the availability of this response model. Application of this response model and associated performance metrics in the context of large-scale design sensitivity studies is also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of the ATLAS RPC detector and Level-1 muon barrel trigger at √(s)=13 TeV

The ATLAS experiment at the Large Hadron Collider (LHC) employs a trigger system consisting of a first-level hardware trigger (L1) and a software-based high-level trigger. The L1 muon trigger system selects muon candidates, assigns them to the correct LHC bunch crossing and classifies them into one of six transverse-momentum threshold classes. The L1 muon trigger system uses resistive-plate chambers (RPCs) to generate the muon-induced trigger signals in the central (barrel) region of the ATLAS detector. The ATLAS RPCs are arranged in six concentric layers and operate in a toroidal magnetic field with a bending power of 1.5 to 5.5 Tm. The RPC detector consists of about 3700 gas volumes with a total surface area of more than 4000 m2. This paper reports on the performance of the RPC detector and L1 muon barrel trigger using 60.8 fb-1 of proton-proton collision data recorded by the ATLAS experiment in 2018 at a centre-of-mass energy of 13 TeV. Detector and trigger performance are studied using Z boson decays into a muon pair. Measurements of the RPC detector response, efficiency, and time resolution are reported. Measurements of the L1 muon barrel trigger efficiencies and rates are presented, along with measurements of the properties of the selected sample of muon candidates. Measurements of the RPC currents, counting rates and mean avalanche charge are performed using zero-bias collisions. Finally, RPC detector response and efficiency are studied at different high voltage and front-end discriminator threshold settings in order to extrapolate detector response to the higher luminosity expected for the High Luminosity LHC.

47 OTHER INSTRUMENTATION↗

On-Orbit Performance of MODIS Solar Diffuser Stability Monitor

Moderate Resolution Imaging Spectroradiometer (MODIS) is currently operated on both the Terra and Aqua spacecraft. It collects data in 20 reflective solar bands (RSB) and 16 thermal emissive bands. MODIS RSB calibration is reflectance based via an on-board solar diffuser (SD). On-orbit changes in the SD bidirectional reflectance factor are tracked by an onboard solar diffuser stability monitor (SDSM). The SDSM functions as an independent ratioing radiometer with nine filtered detectors, covering wavelengths in the visible (VIS) and near-infrared (NIR) spectral regions. A brief overview of SDSM design functions, on-orbit operations, and performance for both Terra and Aqua MODIS is provided. In addition to the SD on-orbit degradation at different wavelengths, the changes in SDSM detector responses and their potential impact on tracking SD on-orbit degradation are examined. After more than 12 years of on-orbit operation, Aqua MODIS SD has shown degradation varying from 0.6% at 0.94 microns to 19.0% at 0.41 microns. Due to more frequent solar exposure and longer operation time, the Terra MODIS SD has experienced a much larger degradation, varying from 2.3% at 0.94 microns to 48.0% at 0.41 microns. For both Terra and Aqua MODIS, the SD has experienced more degradation at shorter wavelengths. Meanwhile, the SDSM detector responses have also experienced wavelength-dependent degradation. The largest change in the SDSM detector responses, however, occurred at longer NIR wavelengths. Since launch, the SDSM systems on both Terra and Aqua MODIS have continued their nominal operations, enabling critical parameters to be derived in support of the RSB on-orbit calibration. The calibration strategies developed for and lessons learned from MODIS SDSM operations, and a preliminary performance comparison with the S-NPP VIIRS SDSM are discussed.

MODIS↗