Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detection.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Improving Non-Destructive Detection Technology Through SAVY Feature Detection

Surveillance of special nuclear material (SNM) storage containers is required by the DOE to assess their integrity across the Complex. This work aims to improve the task of container inspections by leveraging automation through machine learning (ML) tools to reduce the human-intensive effort and expert-level knowledge needed to assess container status. A field-deployable, non-destructive technology was designed using off-the-shelf components to collect multiple images from different perspectives of containers in storage to detect both spatial features of interest and anomalies of concern. Nine ML models were generated using unique training datasets and parameters. Learned features include SAVY surface regions including the body side wall, collar, lid, filter, and printed/etched information. Average Precision (AP) is used to calculate detection performance when both viewing previously seen environments and previously unseen environments. The application of image transformations and resolution scaling while training greatly improved the detection performance in unseen environments, and significantly increasing the number of computation iterations improved detection performance on previously seen environments. Additional capabilities were developed including the novel detection of procedural non-compliance and the ability to localize anomalies relative to SAVY surface features.

97 MATHEMATICS AND COMPUTING↗

Nucleic acid detection system and method for detecting influenza

The invention provides a rapid, sensitive and specific nucleic acid detection system which utilizes isothermal nucleic acid amplification in combination with a lateral flow chromatographic device, or DNA dipstick, for DNA-hybridization detection. The system of the invention requires no complex instrumentation or electronic hardware, and provides a low cost nucleic acid detection system suitable for highly sensitive pathogen detection. Hybridization to single-stranded DNA amplification products using the system of the invention provides a sensitive and specific means by which assays can be multiplexed for the detection of multiple target sequences.

59 BASIC BIOLOGICAL SCIENCES↗

A halo-independent lower bound on the dark matter capture rate in the Sun from a direct detection signal

We show that a positive signal in a dark matter (DM) direct detection experiment can be used to place a lower bound on the DM capture rate in the Sun, independent of the DM halo. For a given particle physics model and DM mass we obtain a lower bound on the capture rate independent of the local DM density, velocity distribution, galactic escape velocity, as well as the scattering cross section. We illustrate this lower bound on the capture rate by assuming that upcoming direct detection experiments will soon obtain a significant signal. When comparing the lower bound on the capture rate with limits on the high-energy neutrino flux from the Sun from neutrino telescopes, we can place upper limits on the branching fraction of DM annihilation channels leading to neutrinos. With current data from IceCube and Super-Kamiokande non-trivial limits can be obtained for spin-dependent interactions and direct annihilations into neutrinos. In some cases also annihilations into ττ or bb start getting constrained. For spin-independent interactions current constraints are weak, but they may become interesting for data from future neutrino telescopes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dark matter directional detection in non-relativistic effective theories

We extend the formalism of dark matter directional detection to arbitrary one-body dark matter-nucleon interactions. The new theoretical framework generalizes the one currently used, which is based on 2 types of dark matter-nucleon interaction only. It includes 14 dark matter-nucleon interaction operators, 8 isotope-dependent nuclear response functions, and the Radon transform of the first 2 moments of the dark matter velocity distribution. We calculate the recoil energy spectra at dark matter directional detectors made of CF{sub 4}, CS{sub 2} and {sup 3}He for the 14 dark matter-nucleon interactions, using nuclear response functions recently obtained through numerical nuclear structure calculations. We highlight the new features of the proposed theoretical framework, and present our results for a spherical dark matter halo and for a stream of dark matter particles. This study lays the foundations for model independent analyses of dark matter directional detection experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detecting electron neutrinos from solar dark matter annihilation by JUNO

We explore the electron neutrino signals from light dark matter (DM) annihilation in the Sun for the large liquid scintillator detector JUNO. In terms of the spectrum features of three typical DM annihilation channels χχ→νν-bar,τ{sup +}τ{sup −},bb-bar, we take two sets of selection conditions to calculate the expected signals and atmospheric neutrino backgrounds based on the Monte Carlo simulation data. Then the JUNO sensitivities to the spin independent DM-nucleon and spin dependent DM-proton cross sections are presented. It is found that the JUNO projected sensitivities are much better than the current spin dependent direct detection experimental limits for the νν-bar and τ{sup +}τ{sup −} channels. In the spin independent case, the JUNO will give the better sensitivity to the DM-nucleon cross section than the LUX and CDMSlite limits for the νν-bar channel with the DM mass lighter than 6.5 GeV. If the νν-bar or τ{sup +}τ{sup −} channel is dominant, the future JUNO results are very helpful for us to understand the tension between the DAMA annual modulation signal and other direct detection exclusions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Towards Real-Time Detection and Tracking of Spatio-Temporal Features: Blob-Filaments in Fusion Plasma [Spatio-Temporal Features in Large Irregular Data: Blob-Filaments in Fusion Plasma]

This work was originally motivated the need to identify and track blob filaments, a feature often associated with instability in magnetically confined fusion plasma. Understanding and mitigating such instability would improve fusion reactors and make fusion a truly inexhaustible source of clean energy. Similar spatio-temporal features are important in many other applications, for example, ignition kernels in combustion and tumor cells in a medical image. This work presents an approach for extracting these features by dividing the overall task into three steps: local identification of feature cells, grouping feature cells into extended feature, and tracking movement of feature through overlapping in space. Through our extensive work in parallelization, we demonstrate that this approach can effectively make use of a large number of compute nodes to detect and track blobs in fusion plasma. On a set of 4.3TB data, we observed linear speedup on 1024 processes and completed blob detection in less than three milliseconds using Edison, a Cray XC30 system at NERSC.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multiparticle Simulations of Quadrupolar Ion Detection in an Ion Cyclotron Resonance Cell with Four Narrow Aperture Detection Electrodes

The current paradigm in FT-ICR cell design is to approximate the ideal three-dimensional quadratic trapping potential as closely as possible to maintain ion cloud spatial coherence and achieve long transients, either with hyperbolically shaped electrodes, shimming electrodes, or by dynamic harmonization. In sharp contrast, the FT-ICR analyzer cell with four narrow aperture detection electrodes (NADEL) introduces significant anharmonic terms to the trapping potential. This analyzer cell is capable of quadrupolar detection by which one can measure a signal that is close to the unperturbed cyclotron frequency. This is far less sensitive to trapping potential and space charge shifts than the reduced cyclotron frequency measured in conventional ICR cells. The quadrupolar mode of ion detection in NADEL cells has been examined previously by SIMION simulations of ion clouds with up to 500 ions per simulation. Here, the behavior of the NADEL analyzer cell is examined through particle-in-cell (PIC) simulations, which allows us to examine the behavior of large populations (tens of thousands) of ions with space charge considerations, and to calculate the induced charge on the NADEL detection electrodes, and thus the transient signal. PIC simulations confirm a unique spatial distribution of the ions, with a coherent motion that results in long transient signals. Dependence of the ion cloud and image current signal on cell design, ion energy, and magnetron radius are examined. Coalescence effects are compared with those found in a dynamically harmonized cell. The insensitivity of the measured cyclotron frequency to space-charge is demonstrated both with simulations and experimentally. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparative Neutron Detection Efficiency in He-3 Proportional Counters and Liquid Scintillators

We present new results on the neutron detection efficiency of detection systems based on He-3 proportional counters compared to organic liquid scintillators. The experiments were conducted using a well-characterized Cf-252 neutron source, measured bare, and shielded with slabs of polyethylene. The results show that the intrinsic neutron detection efficiency for the bare source is approximately 25% for the He-3 system, and 67% for the liquid scintillator system. When polyethylene sheets were used to shield the source in 2.54 cm increments, the neutron detection efficiency of both systems decreased exponentially to approximately 10% for the case of 25.4 cm. Experimental results were simulated using MCNPX-PoliMi and good agreement was found between measurement and simulation results for all the cases considered here.

Organic scintillator, He-3, neutron detection, det↗

An integrated portable Raman sensor with nanofabricated gold bowtie array substrates for energetics detection

An integrated field-portable surface enhaned Raman scattering (SERS) sensing system has been developed and evaluated for quantitative analysis of energetics such as perchlorate (ClO4-) and trinitrotoluene (TNT) at environmentally-relevant concentrations and conditions. The detection system consists of a portable Raman spectrometer equipped with an optical fiber probe that is coupled with novel elevated gold bowtie nanostructural arrays as a sensitive and reproducible SERS substrate. Using the standard addition technique, we show that ClO4- and TNT can be quantified at concentrations as low as 0.66 mg/L (or ~6.6 M) and 0.20 mg/L (~0.9 M), respectively, in groundwater samples collected from selected military sites. This research represents the first step toward the development of a field SERS sensor which may permit rapid, in-situ screening and analysis for various applications including national security, chemical, biological and environmental detection.

Abu Hatab, Nahla A↗

Charge exchange recombination detection of low-Z and medium-Z impurities in the extreme UV using a digital lock-in technique

More sensitive detection of charge exchange recombination lines from low-Z elements, and first-time detection from the medium-Z elements nickel and copper, has been achieved in DIII-D plasmas with a digital lock-in technique. That portion of the extreme UV spectrum varying synchronously in time with the square-wave modulation of a high energy, neutral heating beam is extracted by forming a scalar product of a correlation function with the data record of each pixel in the linear array detector. The usual, dense array of collisionally excited, metallic lines from the tokamak plasma is strongly suppressed, leaving only a sparse spectrum of lines dominated by charge exchange recombination transitions from fully stripped, low-Z elements. In plasmas with high metal content, charge exchange recombination lines from the Li-like ions of nickel and copper have been positively identified.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

FERMI LAT PULSED DETECTION OF PSR J0737-3039A IN THE DOUBLE PULSAR SYSTEM

We report the Fermi Large Area Telescope discovery of {gamma}-ray pulsations from the 22.7 ms pulsar A in the double pulsar system J0737-3039A/B. This is the first mildly recycled millisecond pulsar (MSP) detected in the GeV domain. The 2.7 s companion object PSR J0737-3039B is not detected in {gamma} rays. PSR J0737-3039A is a faint {gamma}-ray emitter, so that its spectral properties are only weakly constrained; however, its measured efficiency is typical of other MSPs. The two peaks of the {gamma}-ray light curve are separated by roughly half a rotation and are well offset from the radio and X-ray emission, suggesting that the GeV radiation originates in a distinct part of the magnetosphere from the other types of emission. From the modeling of the radio and the {gamma}-ray emission profiles and the analysis of radio polarization data, we constrain the magnetic inclination {alpha} and the viewing angle {zeta} to be close to 90 Degree-Sign , which is consistent with independent studies of the radio emission from PSR J0737-3039A. A small misalignment angle between the pulsar's spin axis and the system's orbital axis is therefore favored, supporting the hypothesis that pulsar B was formed in a nearly symmetric supernova explosion as has been discussed in the literature already.

79 ASTRONOMY AND ASTROPHYSICS↗

High-energy gamma-ray emission from solar flares: Summary of Fermi large area telescope detections and analysis of two M-class flares

We present the detections of 18 solar flares detected in high-energy γ-rays (above 100 MeV) with the Fermi Large Area Telescope (LAT) during its first 4 yr of operation. This work suggests that particle acceleration up to very high energies in solar flares is more common than previously thought, occurring even in modest flares, and for longer durations. Interestingly, all these flares are associated with fairly fast coronal mass ejections (CMEs). We then describe the detailed temporal, spatial, and spectral characteristics of the first two long-lasting events: the 2011 March 7 flare, a moderate (M3.7) impulsive flare followed by slowly varying γ-ray emission over 13 hr, and the 2011 June 7 M2.5 flare, which was followed by γ-ray emission lasting for 2 hr. We compare the Fermi LAT data with X-ray and proton data measurements from GOES and RHESSI. We argue that the γ-rays are more likely produced through pion decay than electron bremsstrahlung, and we find that the energy spectrum of the proton distribution softens during the extended emission of the 2011 March 7 flare. This would disfavor a trapping scenario for particles accelerated during the impulsive phase of the flare and point to a continuous acceleration process at play for the duration of the flares. CME shocks are known for accelerating the solar energetic particles (SEPs) observed in situ on similar timescales, but it might be challenging to explain the production of γ-rays at the surface of the Sun while the CME is halfway to the Earth. A stochastic turbulence acceleration process occurring in the solar corona is another likely scenario. Detailed comparison of characteristics of SEPs and γ-ray-emitting particles for several flares will be helpful to distinguish between these two possibilities.

79 ASTRONOMY AND ASTROPHYSICS↗

Indirect Detection Analysis: Wino Dark Matter Case Study

We perform a multichannel analysis of the indirect signals for the Wino Dark Matter, including one-loop electroweak and Sommerfeld enhancement corrections. We derive limits from cosmic ray antiprotons and positrons, from continuum galactic and extragalactic diffuse γ-ray spectra, from the absence of γ-ray line features at the galactic center above 500 GeV in energy, from γ-rays toward nearby dwarf spheroidal galaxies and galaxy clusters, and from CMB power-spectra. Additionally, we show the future prospects for neutrino observations toward the inner Galaxy and from antideuteron searches. For each of these indirect detection probes we include and discuss the relevance of the most important astrophysical uncertainties that can impact the strength of the derived limits. We find that the Wino as a dark matter candidate is excluded in the mass range bellow simeq 800 GeV from antiprotons and between 1.8 and 3.5 TeV from the absence of a γ-ray line feature toward the galactic center. Limits from other indirect detection probes confirm the main bulk of the excluded mass ranges.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Complementary test of the dark matter self-interaction in dark U(1) model by direct and indirect dark matter detection

The halo dark matter (DM) can be captured by the Sun if its final velocity after the collision with a nucleus in the Sun is less than the escape velocity. We consider a selfinteracting dark matter (SIDM) model where U(1) gauge symmetry is introduced to account for the DM self-interaction. Such a model naturally leads to isospin violating DM-nucleon interaction, although isospin symmetric interaction is still allowed as a special case. We present the IceCube-PINGU 2σ sensitivity to the parameter range of the above model with 5 years of search for neutrino signature from DM annihilation in the Sun. This indirect detection complements the direct detection by probing those SIDM parameter ranges which are either the region for very small m{sub χ} or the region opened up due to isospin violations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Prospects for axion detection in natural SUSY with mixed axion-higgsino dark matter: back to invisible?

Under the expectation that nature is natural, we extend the Standard Model to include SUSY to stabilize the electroweak sector and PQ symmetry to stabilize the QCD sector. Then natural SUSY arises from a Kim-Nilles solution to the SUSY μ problem which allows for a little hierarchy where μ~ $f$ $^{2}_{a}$/M P~ 100-300 GeV while the SUSY particle mass scale m SUSY~ 1-10 TeV >> μ. Dark matter then consists of two particles: a higgsino-like WIMP and a SUSY DFSZ axion. The range of allowed axion mass values m a depends on the mixed axion-higgsino relic density. Here, the range of m a is actually restricted in this case by limits on WIMPs from direct and indirect detection experiments. We plot the expected axion detection rate at microwave cavity experiments. The axion-photon-photon coupling is severely diminished by charged higgsino contributions to the anomalous coupling. In this case, the axion may retreat, at least temporarily, back into the regime of near invisibility. From our results, we urge new ideas for techniques which probe both deeper and more broadly into axion coupling versus axion mass parameter space.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

VERY HIGH ENERGY γ-RAYS FROM THE UNIVERSE’S MIDDLE AGE: DETECTION OF THE z = 0.940 BLAZAR PKS 1441+25 WITH MAGIC

The flat-spectrum radio quasar PKS 1441+25 at a redshift of z = 0.940 is detected between 40 and 250 GeV with a significance of 25.5σ using the MAGIC telescopes. Together with the gravitationally lensed blazar QSO B0218+357 (z = 0.944), PKS 1441+25 is the most distant very high energy (VHE) blazar detected to date. The observations were triggered by an outburst in 2015 April seen at GeV energies with the Large Area Telescope on board Fermi. Multi-wavelength observations suggest a subdivision of the high state into two distinct flux states. In the band covered by MAGIC, the variability timescale is estimated to be 6.4 ± 1.9 days. Modeling the broadband spectral energy distribution with an external Compton model, the location of the emitting region is understood as originating in the jet outside the broad-line region (BLR) during the period of high activity, while being partially within the BLR during the period of low (typical) activity. The observed VHE spectrum during the highest activity is used to probe the extragalactic background light at an unprecedented distance scale for ground-based gamma-ray astronomy.

79 ASTRONOMY AND ASTROPHYSICS↗

Prospects for detecting dark matter with GLAST in light of the WMAP haze

Observations by the Wilkinson Microwave Anisotropy Probe (WMAP) experiment have identified an excess of microwave emission from the center of the Milky Way. It has previously been shown that this 'WMAP haze' could be synchrotron emission from relativistic electrons and positrons produced in the annihilations of dark matter particles. In particular, the intensity, spectrum, and angular distribution of the WMAP haze is consistent with an electroweak scale dark matter particle (such as a supersymmetric neutralino or Kaluza-Klein dark matter in models with universal extra dimensions) annihilating with a cross section on the order of {sigma}v{approx}3x10{sup -26} cm{sup 3}/s and distributed with a cusped halo profile. No further exotic astrophysical or annihilation boost factors are required. If dark matter annihilations are in fact responsible for the observed haze, then other annihilation products will also be produced, including gamma rays. In this article, we study the prospects for the GLAST satellite to detect gamma rays from dark matter annihilations in the Galactic Center region in this scenario. We find that by studying only the inner 0.1 deg. around the Galactic Center, GLAST will be able to detect dark matter annihilating to heavy quarks, gauge bosons, or tau leptons over astrophysical backgrounds with 5{sigma} (3{sigma}) significance if they are lighter than approximately 320-500 GeV (500-750 GeV). If the angular window is broadened to study the dark matter halo profile's angular extension (while simultaneously reducing the astrophysical backgrounds), weakly interacting, massive particles (WIMPs) as heavy as several TeV can be identified by GLAST with high significance. Only if the dark matter particles annihilate mostly to electrons or muons will GLAST be unable to identify the gamma ray spectrum associated with the WMAP haze.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Microbial agent detection using near-IR electrophoretic and spectral signatures (MADNESS) for rapid identification in detect-to-warn applications.

Rapid identification of aerosolized biological agents following an alarm by particle triggering systems is needed to enable response actions that save lives and protect assets. Rapid identifiers must achieve species level specificity, as this is required to distinguish disease-causing organisms (e.g., Bacillus anthracis) from benign neighbors (e.g., Bacillus subtilis). We have developed a rapid (1-5 minute), novel identification methodology that sorts intact organisms from each other and particulates using capillary electrophoresis (CE), and detects using near-infrared (NIR) absorbance and scattering. We have successfully demonstrated CE resolution of Bacillus spores and vegetative bacteria at the species level. To achieve sufficient sensitivity for detection needs ({approx}10{sup 4} cfu/mL for bacteria), we have developed fiber-coupled cavity-enhanced absorbance techniques. Using this method, we have demonstrated {approx}two orders of magnitude greater sensitivity than published results for absorbing dyes, and single particle (spore) detection through primarily scattering effects. Results of the integrated CE-NIR system for spore detection are presented.

59 BASIC BIOLOGICAL SCIENCES↗