NSIDC Data Center: Energy Reduction Strategies

The Green Data Center Project was a successful effort to significantly reduce the energy use of the National Snow and Ice Data Center (NSIDC). Through a full retrofit of a traditional air conditioning system, the cooling energy required to meet the data center’s constant load has been reduced by over 70% for summer months and over 90% for cooler winter months. This significant reduction is achievable through the use of airside economization and a new indirect evaporative cooling cycle. One of the goals of this project was to create awareness of simple and effective energy reduction strategies for data centers. Although this particular project was able to maximize the positive effects of airside economization and indirect evaporative cooling because of its geographic location, similar strategies may also be relevant for many other sites and data centers in the United States.

NSIDC, Data, Energy, Reduction, Strategies↗

Energy Performance Testing of Asetek's RackCDU System at NREL's High Performance Computing Data Center

In this study, we report on the first tests of Asetek's RackCDU direct-to-chip liquid cooling system for servers at NREL's ESIF data center. The system was simple to install on the existing servers and integrated directly into the data center's existing hydronics system. The focus of this study was to explore the total cooling energy savings and potential for waste-heat recovery of this warm-water liquid cooling system. RackCDU captured up to 64% of server heat into the liquid stream at an outlet temperature of 89 degrees F, and 48% at outlet temperatures approaching 100 degrees F. This system was designed to capture heat from the CPUs only, indicating a potential for increased heat capture if memory cooling was included. Reduced temperatures inside the servers caused all fans to reduce power to the lowest possible BIOS setting, indicating further energy savings potential if additional fan control is included. Preliminary studies manually reducing fan speed (and even removing fans) validated this potential savings but could not be optimized for these working servers. The Asetek direct-to-chip liquid cooling system has been in operation with users for 16 months with no necessary maintenance and no leaks.

97 MATHEMATICS AND COMPUTING↗

Wireless Sensor Network for Improving the Energy Efficiency of Data Centers

Data centers occupy less than 2% of the federally owned portfolio under the jurisdiction, custody or control of the U.S. General Services Administration (GSA), but represent nearly 5% of the agency’s overall energy budget. Assuming that energy use in GSA’s data centers tracks with industry averages, GSA can anticipate that data center energy use will grow at an annual rate of 15%, a doubling of energy use every five years.1 In fact, energy is the single largest operating expense for most data centers. Improving the energy performance of data center systems supports progress toward meeting federally mandated greenhouse gas emission-­reduction goals, while reducing operating and energy costs and allowing for greater flexibility in future expansion by eliminating the need to provide additional power and cooling. Studies sponsored by the U.S. Department of Energy (DOE) and the U.S. Environmental Protection Agency (EPA) have shown that energy use can be reduced by 25% through implementation of best practices and commercially available technologies. The present study evaluated the effectiveness of a strategy to cost- effectively improve the efficiency of data center cooling, which is the single largest non-­IT load. The technology that was evaluated consists of a network of wireless sensors—including branch circuit power monitors, temperature sensors, humidity sensors, and pressure sensors, along with an integrated software product to help analyze the collected data. The technology itself does not save energy; however, its information collection and analysis features enable users to understand operating conditions and identify problem areas. In addition, data obtained by this technology can be input into assessment tools that can identify additional best practice measures. Energy savings result from the implementation of the best practices. The study was conducted to validate the premise that providing data center operators with detailed, real- time measurement of environmental parameters and power consumption enables them to establish baseline performance, discover areas of sub-optimal performance, and identify concrete opportunities for improvement.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hybrid Cooling and Water Treatment for Resilient, Water-Self-Sufficient Data Centers

The continued growth of data center infrastructure is intensifying demand for freshwater resources, particularly in water-stressed regions, and is increasingly limiting sustainable capacity expansion. This work investigates a conceptual hybrid system that integrates freeze desalination with ultrasonic-assisted ice separation to enable on-site production of pure water from diverse sources, including seawater, brackish groundwater, and reclaimed industrial or agricultural wastewater. Simultaneously, the system produces low-temperature cooling streams that enhance heat removal in high power density computing environments. A process-level thermodynamic analysis is performed across a range of boundary and operating conditions, including variations in feed concentration, freezing temperature, and mass flow rate. The results are presented as performance curves relating feedwater concentration and target purified water output to the corresponding intake flow requirements, enabling estimation of source water demand per unit of Information Technology Equipment (ITE) energy consumption (kWh) across varying data center scales and operational scenarios. The corresponding electrical energy consumption for integrated cooling and water treatment is also evaluated as a function of system operating parameters and target water production levels. These results provide a basis for evaluating system feasibility across different conditions and for identifying parameter ranges in which integrated water treatment and cooling improve resource efficiency, thermal performance, and operational flexibility in data centers.

Elhefny, Aly [ORNL] (ORCID:0000000284907923)↗

Data Center Facility Monitoring with Physics Aware Approach

U.S. Department of Energy's National Renewable Energy Laboratory (NREL) hosts one of the world's most energy-efficient HPC data centers; this system uses component-level warm-water liquid cooling to efficiently remove heat from the data center and capture it for reuse in the building or rejection to the atmosphere. Given the complexity of this system, building data-driven tools for holistically monitoring and operating the entire data center is a priority for ensuring maximal efficiency and resiliency. In this advanced smart facility, over one million metrics are recorded per minute using state-of-the-art streaming data architecture and software to capture and process the state of the system in real time. Here we detail two efforts to effectively analyze, visualize, and interpret this large volume streaming data. We have developed a novel, flexible system for identifying and visualizing individual metric anomalies and component performance across the data center through automatic metadata extraction and physically-motivated visualization for quick interpretation. Additionally, to directly connect system maintenance to data stream processing we explore a physics informed multi-metric drift and anomaly detection application to detect scale-build up in heat exchangers.

anomaly detection↗

The environmental footprint of data centers in the United States

Much of the world's data are stored, managed, and distributed by data centers. Data centers require a tremendous amount of energy to operate, accounting for around 1.8% of electricity use in the United States. Large amounts of water are also required to operate data centers, both directly for liquid cooling and indirectly to produce electricity. For the first time, we calculate spatially-detailed carbon and water footprints of data centers operating within the United States, which is home to around one-quarter of all data center servers globally. Our bottom-up approach reveals one-fifth of data center servers direct water footprint comes from moderately to highly water stressed watersheds, while nearly half of servers are fully or partially powered by power plants located within water stressed regions. Approximately 0.5% of total US greenhouse gas emissions are attributed to data centers. We investigate tradeoffs and synergies between data center's water and energy utilization by strategically locating data centers in areas of the country that will minimize one or more environmental footprints. Our study quantifies the environmental implications behind our data creation and storage and shows a path to decrease the environmental footprint of our increasing digital footprint.

54 ENVIRONMENTAL SCIENCES↗

Improving Thermal Management Strategies for Data Centers: A Physical Testbed Incorporating Small Modular Reactor and Microreactor Technology

This study aims to accelerate the demonstration of various thermal management systems for data centers using nuclear-generated heat to enhance energy and grid reliability. Utilizing mobile containerized and stationary test beds at INL's High Performance Computing (HPC) facility, this project integrates with various nuclear-related energy systems testing facilities. Key components include immersion cooling apparatus, absorption chillers, and adjustable thermal management simulators. Tasks involve acquiring necessary hardware, sensors, and cooling apparatus, engaging with data center industry stakeholders, and providing a testing platform for algorithms, models, tools, and software. The objective is to expedite the deployment of nuclear-powered data centers, thereby improving energy reliability and affordability.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Data Center Waste Heat as an Emerging Urban Thermal Hazard: First Field Measurements of Neighborhood-Scale Air Temperature Impacts

Data centers are among the fastest-growing sources of concentrated anthropogenic heat in urban environments. Despite heat flux densities that exceed peak solar irradiance by a factor of 2–6, their thermal impacts on adjacent communities have never been directly measured or reported in the peer-reviewed literature. This short communication addresses that gap by presenting the first vehicle-based traverse measurements of air temperature in residential neighborhoods downwind of operational data centers. Five traverses at four facilities in the Phoenix, Arizona metropolitan area, ranging from a 36 MW single-building data center in Mesa to a 169 MW colocation campus in Chandler, reveal downwind air temperature warming as high as 2.2 °C, with average downwind air temperatures 0.7–0.9 °C warmer than corresponding upwind areas. Thermal signatures were detectable at distances up to 500 m from facility perimeters. The 36 MW Mesa facility rejects waste heat equivalent to the electricity consumption of approximately 40,000 households, while the 169 MW Chandler campus is equivalent to over 180,000 households, both concentrated into footprints smaller than a single residential subdivision. With U.S. data center capacity projected to more than double by 2030, these findings establish data center anthropogenic waste heat as a previously undocumented urban thermal hazard demanding attention from the data center and urban planning communities.

Phoenix↗

SystemBurn: Principles of Design and Operation, Release 2.0

As high performance computing technology progresses toward the progressively more extreme scales required to address critical computational problems of both national and global interest, power and cooling for these extreme scale systems is becoming a growing concern. A standardized methodology for testing system requirements under maximal system load and validating system environmental capability to meet those requirements is critical to maintaining system stability and minimizing power and cooling risks for high end data centers. Moreover, accurate testing permits the high end data center to avoid issues of under- or over-provisioning power and cooling capacity saving resources and mitigating hazards. Previous approaches to such testing have employed an ad hoc collection of tools, which have been anecdotally perceived to produce a heavy system load. In this report, we present SystemBurn, a software tool engineered to allow a system user to methodically create a maximal system load on large scale systems for the purposes of testing and validation.

99 GENERAL AND MISCELLANEOUS↗

SystemBurn: Principles of Design and Operation Release 2.1

As high performance computing technology progresses toward the progressively more extreme scales required to address critical computational problems of both national and global interest, power and cooling for these extreme scale systems is becoming a growing concern. A standardized methodology for testing system requirements under maximal system load and validating system environmental capability to meet those requirements is critical to maintaining system stability and minimizing power and cooling risks for high end data centers. Moreover, accurate testing permits the high end data center to avoid issues of under- or over-provisioning power and cooling capacity saving resources and mitigating hazards. Previous approaches to such testing have employed an ad hoc collection of tools, which have been anecdotally perceived to produce a heavy system load. In this report, we present SystemBurn, a software tool engineered to allow a system user to methodically create a maximal system load on large scale systems for the purposes of testing and validation.

99 GENERAL AND MISCELLANEOUS↗

SystemBurn: Principles of Design and Operation Release 3.1

As high performance computing technology progresses toward the progressively more extreme scales required to address critical computational problems of both national and global interest, power and cooling for these extreme scale systems is becoming a growing concern. A standardized methodology for testing system requirements under maximal system load and validating system environmental capability to meet those requirements is critical to maintaining system stability and minimizing power and cooling risks for high end data centers. Moreover, accurate testing permits the high end data center to avoid issues of under- or over-provisioning power and cooling capacity saving resources and mitigating hazards. Previous approaches to such testing have employed an ad hoc collection of tools, which have been anecdotally perceived to produce a heavy system load. In this report, we present SystemBurn, a software tool engineered to allow a system user to methodically create a maximal system load on large scale systems for the purposes of testing and validation.

Benchmark↗

Demonstration of Data Center Energy Use Prediction Software

This report documents a demonstration of a software modeling tool from Romonet that was used to predict energy use and forecast energy use improvements in an operating data center. The demonstration was conducted in a conventional data center with a 15,500 square foot raised floor and an IT equipment load of 332 kilowatts. It was cooled using traditional computer room air handlers and a compressor-based chilled water system. The data center also utilized an uninterruptible power supply system for power conditioning and backup. Electrical energy monitoring was available at a number of locations within the data center. The software modeling tool predicted the energy use of the data center's cooling and electrical power distribution systems, as well as electrical energy use and heat removal for the site. The actual energy used by the computer equipment was recorded from power distribution devices located at each computer equipment row. The model simulated the total energy use in the data center and supporting infrastructure and predicted energy use at energy-consuming points throughout the power distribution system. The initial predicted power levels were compared to actual meter readings and were found to be within approximately 10 percent at a particular measurement point, resulting in a site overall variance of 4.7 percent. Some variances were investigated, and more accurate information was entered into the model. In this case the overall variance was reduced to approximately 1.2 percent. The model was then used to predict energy use for various modification opportunities to the data center in successive iterations. These included increasing the IT equipment load, adding computer room air handler fan speed controls, and adding a water-side economizer. The demonstration showed that the software can be used to simulate data center energy use and create a model that is useful for investigating energy efficiency design changes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pool boiling heat transfer evaluation of next-generation dielectric fluid: Opteon™ 2P50

The growing use of artificial intelligence has led to heavy thermal loads and high heat dissipation rates in data centers. Conventional air-cooled technologies are not able to fulfill these requirements. To overcome these challenges, two-phase immersion cooling (2PIC) has emerged as one of the leading technologies for high power-density chips. 2PIC increases the heat dissipation rate and efficiency of the system while reducing the footprint of the cooling equipment. A fluid with adequate dielectric properties, a suitable normal boiling temperature to maintain chip temperatures, and good material compatibility, is desired for 2PIC system. In this study, the pool boiling heat transfer of a new developmental dielectric fluid, Opteon™ 2P50, was experimentally investigated. The heat transfer coefficients at various heat fluxes (20–150 kW/m 2 ) and the critical heat flux were measured using a smooth aluminum surface. Compared with HFE-7100, Opteon™ 2P50 shows higher heat transfer coefficient (up to 59% higher) and a slightly lower value of critical heat flux (around 5.9% lower). The modified Cooper correlation with the optimized leading constant resulted in reliable prediction accuracy with a 5.3% mean absolute error percentage. Overall, these results indicate that the new dielectric fluid provides similar thermal performance to some legacy fluids.

2P50↗

ESnet/JLab FPGA Accelerated Transport

To increase the science rate for high data rates/volumes, Thomas Jefferson National Accelerator Facility (JLab) has partnered with Energy Sciences Network (ESnet) to define an edge to data center traffic shaping / steering transport capability featuring data event aware network shaping and forwarding. The keystone of this ESnet+JLab FPGA Accelerated Transport (EJFAT) is the joint development of an AI/ML directed dynamic compute work Load Balancer (LB) of UDP streamed data. The LB is a suite consisting of a Field Programmable Gate Array (FPGA) executing the dynamically configurable, low fixed latency LB data plane featuring real-time packet redirection and high throughput, and a control plane running on the FPGA host computer that monitors network and compute farm telemetry in order to make dynamic AI/ML guided decisions for destination compute host redirection/load balancing and destination resource provisioning. The LB provides for three-tier horizontal scaling across LB suites, core compute hosts, and CPUs within a host. The LB effectively provides seamless integration of edge/core computing to support direct experimental data processing for immediate use by JLab science programs and others such as the EIC as well as data centers of the future requiring high throughput and low latency for both hot and cooled data for both running experiment data acquisition systems and data center use cases.

97 MATHEMATICS AND COMPUTING↗

Scalable Data Center Capacity for DOE's AI Prototype: A Rapidly Available Gigawatt Data Center for DOE

The multilaboratory Gigawatt Data Center working group was commissioned to identify approaches to rapidly establish federal data centers with scalable capacities up to 1,000 MW. These state-of-the-art facilities will serve as hubs for interdisciplinary collaboration, industry partnerships, and transformative applications of artificial intelligence. The proposed strategic shift includes facilitating multilaboratory collaboration, prioritizing operational efficiency, expanding public–private partnerships, optimizing investments, ensuring long-term contractual flexibility, supporting open science and secure data enclaves, and exploiting high-speed national networks. Owing to their extensive experience and best practices, the US Department of Energy national laboratories are uniquely positioned to lead this initiative. We recommend conducting a feasibility analysis to rapidly identify the optimal sites for this initiative, and the effort will likely involve private industry for design, construction, financing, and operational integration. We also propose establishing multiple geographically diverse sites to ensure energy resilience, high operational reliability, and a diverse user base, thereby effectively addressing the nation’s critical needs.

42 ENGINEERING↗

Spatiotemporal modeling of node temperatures in supercomputers

Los Alamos National Laboratory (LANL) is home to many large supercomputing clusters. These clusters require an enormous amount of power (~500-2000 kW each), and most of this energy is converted into heat. Thus, cooling the components of the supercomputer becomes a critical and expensive endeavor. Recently a project was initiated to investigate the effect that changes to the cooling system in a machine room had on three large machines that were housed there. Coupled with this goal was the aim to develop a general good-practice for characterizing the effect of cooling changes and monitoring machine node temperatures in this and other machine rooms. This paper focuses on the statistical approach used to quantify the effect that several cooling changes to the room had on the temperatures of the individual nodes of the computers. The largest cluster in the room has 1,600 nodes that run a variety of jobs during general use. Since extremes temperatures are important, a Normal distribution plus generalized Pareto distribution for the upper tail is used to model the marginal distribution, along with a Gaussian process copula to account for spatio-temporal dependence. A Gaussian Markov random field (GMRF) model is used to model the spatial effects on the node temperatures as the cooling changes take place. This model is then used to assess the condition of the node temperatures after each change to the room. The analysis approach was used to uncover the cause of a problematic episode of overheating nodes on one of the supercomputing clusters. Lastly, this same approach can easily be applied to monitor and investigate cooling systems at other data centers, as well.

97 MATHEMATICS AND COMPUTING↗