Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DOPPLER EFFECT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Coherent Laser Instrument Would Measure Range and Velocity

A proposed instrument would project a narrow laser beam that would be frequency-modulated with a pseudorandom noise (PN) code for simultaneous measurement of range and velocity along the beam. The instrument performs these functions in a low mass, power, and volume package using a novel combination of established techniques. Originally intended as a low resource- footprint guidance sensor for descent and landing of small spacecraft onto Mars or small bodies (e.g., asteroids), the basic instrument concept also lends itself well to a similar application guiding aircraft (especially, small unmanned aircraft), and to such other applications as ranging of topographical features and measuring velocities of airborne light-scattering particles as wind indicators. Several key features of the instrument s design contribute to its favorable performance and resource-consumption characteristics. A laser beam is intrinsically much narrower (for the same exit aperture telescope or antenna) than a radar beam, eliminating the need to correct for the effect of sloping terrain over the beam width, as is the case with radar. Furthermore, the use of continuous-wave (CW), erbium-doped fiber lasers with excellent spectral purity (narrow line width) permits greater velocity resolution, while reducing the laser s power requirement compared to a more typical pulsed solid-state laser. The use of CW also takes proper advantage of the increased sensitivity of coherent detection, necessary in the first place for direct measurement of velocity using the Doppler effect. However, measuring range with a CW beam requires modulation to "tag" portions of it for time-of-flight determination; typically, the modulation consists of a PN code. A novel element of the instrument s design is the use of frequency modulation (FM) to accomplish both the PN-modulation and the Doppler-bias frequency shift necessary for signed velocity measurements. This permits the use of a single low-power waveguide electrooptic phase modulator, while simultaneously mitigating the effects of speckle as a noise source in the coherent detection.

Chang, Daniel↗

New ion trap for atomic frequency standard applications

A novel linear ion trap that permits storage of a large number of ions with reduced susceptibility to the second-order Doppler effect caused by the radio frequency (RF) confining fields has been designed and built. This new trap should store about 20 times the number of ions a conventional RF trap stores with no corresponding increase in second-order Doppler shift from the confining field. In addition, the sensitivity of this shift to trapping parameters, i.e., RF voltage, RF frequency, and trap size, is greatly reduced.

Prestage, J. D.↗

Discovery of a periodic pulsating binary X-ray source in Hercules from Uhuru.

We have discovered a new pulsating X-ray source with a 1.24-sec period in the constellation Hercules. Analysis of 5 months of data has shown the existence of periodic variations in the intensity of the source and correlated sinusoidal variations in the period of the 1.24-sec pulsations. As in the case of the pulsating X-ray source Cen X-3, we interpret this effect as due to an occulting binary system, with the intensity changes due to occultation of the X-ray source by its companion and with the sinusoidal variations in the period of the 1.24-sec pulsations due to the Doppler effect. In addition, we have observed a longer-time scale cycle in which the source is bright and pulsing for approximately 9 days during which we can observe the 1.7-day occulting, followed by approximately 27 days during which the source is not detected above background on individual 20-sec scans.

Tananbaum, H.↗

Advanced research to qualify man for long term weightlessness.

NASA is in the process of conducting a broad program of research and development of technology to qualify, support, and permit the successful use of man in long-term space flight. The technological tasks include human engineering, extravehicular engineering, life support, and human research to assess the effect of space stresses on human physiology and psychology. Various testing techniques that are being used may have future relevance to world health. These include a biocybernetic approach to the study of cardiovascular stresses, measurement of blood flow by means of the Doppler effect, and a device for simulating radiation dosages similar to those produced in solar flares. The planned program includes a study of both humans and animals.

Jones, W. L.↗

Evidence for the binary nature of Centaurus X-3 from Uhuru X-ray observations.

Analysis of data spanning a year of observations of the pulsating X-ray source Cen X-3 from Uhuru has revealed the existence of periodic variations in intensity of the source and correlated sinusoidal variations in the period of the 4.8-sec pulsations. We interpret this effect as due to an occulting binary system. The changes in intensity are then due to occultation of the X-ray source by a large massive companion, and the sinusoidal variations in the period of the 4.8-sec pulsations are due to Doppler effect. Physical parameters for the system are derived, and evidence for the existence and nature of an extended atmosphere surrounding the massive occulting object is discussed.

Schreier, E.↗

Visualizing ultrasound through computational modeling

The Doppler Ultrasound Hematocrit Project (DHP) hopes to find non-invasive methods of determining a person s blood characteristics. Because of the limits of microgravity and the space travel environment, it is important to find non-invasive methods of evaluating the health of persons in space. Presently, there is no well developed method of determining blood composition non-invasively. This projects hopes to use ultrasound and Doppler signals to evaluate the characteristic of hematocrit, the percentage by volume of red blood cells within whole blood. These non-invasive techniques may also be developed to be used on earth for trauma patients where invasive measure might be detrimental. Computational modeling is a useful tool for collecting preliminary information and predictions for the laboratory research. We hope to find and develop a computer program that will be able to simulate the ultrasound signals the project will work with. Simulated models of test conditions will more easily show what might be expected from laboratory results thus help the research group make informed decisions before and during experimentation. There are several existing Matlab based computer programs available, designed to interpret and simulate ultrasound signals. These programs will be evaluated to find which is best suited for the project needs. The criteria of evaluation that will be used are 1) the program must be able to specify transducer properties and specify transmitting and receiving signals, 2) the program must be able to simulate ultrasound signals through different attenuating mediums, 3) the program must be able to process moving targets in order to simulate the Doppler effects that are associated with blood flow, 4) the program should be user friendly and adaptable to various models. After a computer program is chosen, two simulation models will be constructed. These models will simulate and interpret an RF data signal and a Doppler signal.

Guo, Theresa W.↗

Ultra-stable Hg(+) trapped ion frequency standard

A fieldable trapped ion frequency standard based on Hg-199(+) ions confined in a hybrid rf/dc linear ion trap is developed. This trap permits storage of large numbers of ions with reduced susceptibility to the second-order Doppler effect caused by the rf confining fields. In preliminary measurements a stability of 2 to 3 x 10(exp -15) was obtained for 10000 second averaging times. These measurements were carried out with a 120 mHz wide atomic resonance line for the 40.5 GHz clock transition with a second order Doppler shift from the rf trapping field of 6 x 10(exp -13).

Prestage, John D.↗

A modified Lorentz theory as a test theory of special relativity

Attention has been given recently to a modified Lorentz theory (MLT) that is based on the generalized Galilean transformation. Some explicit formulas within the framework of MLT, dealing with the one-way velocity of light, slow-clock transport, and the Doppler effect are derived. A number of typical experiments are analyzed on this basis. Results indicate that the empirical equivalence between MLT and special relativity is still maintained to second order terms. The results of previous works that predict that the MLT might be distinguished from special relativity at the third order by Doppler centrifuge tests capable of a fractional frequency detection threshold of 10 to the -15th are confirmed.

Chang, T.↗

A study of reactivity biases and their dependence on spatial discretization in depleted TRIGA fuel

The impact of spatial discretization on reactivity biases in TRIGA fuel models was analyzed here. In particular, unit-cell analyses in 2-D and 3-D were performed using Serpent to understand how spatial discretization affects the accuracy with which the effects of material evolution and temperature feedback are resolved. For temperature-dependent cases, a simple, single-channel model was employed. Analysis of 2-D models showed that essentially no radial discretization resolution is needed to eliminate biases (i.e., to reduce biases to the level of stochastic uncertainties) due to material evolution but that more than eight, equal-area, radial regions are needed to resolve temperature-feedback effects. Analysis of 3-D models showed that at least seven, equal-volume, axial regions may be required to resolve material evolution with temperature feedback leading to insignificant additional bias. Because of memory constraints, a full-core model with radially- and axially-resolved fuel elements may be impractical, especially for production-level analyses. Consequently, an “effective Doppler temperature” was determined empirically as a function of the radially-averaged temperature and may be used for future, full-core analyses.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Laser Doppler And Range Systems For Spacecraft

Report discusses two types of proposed laser systems containing active transponders measuring distance (range) and line-of-sight velocity (via Doppler effect) between deep space vehicle and earth-orbiting satellite. Laser system offers diffraction advantage over microwave system. Delivers comparable power to distant receiver while using smaller transmitting and receiving antennas and less-powerful transmitter. Less subject to phase scintillations caused by passage through such inhomogeneous media as solar corona. One type of system called "incoherent" because range and Doppler measurements do not require coherence with laser carrier signals. Other type of system called "coherent" because successful operation requires coherent tracking of laser signals.

Kinman, P. W.↗

Time-lens photon Doppler velocimetry (TL-PDV)

Here, we describe a time lens (TL) to expand the dynamic range of photon Doppler velocimetry (PDV) systems. The principle and preliminary design of a TL-PDV system are explained and shown to be feasible through simulations. In a PDV system, an interferometer is used for measuring frequency shifts due to the Doppler effect from the target motion. However, the sampling rate of the electronics could limit the velocity range of a PDV system. A four-wave-mixing (FWM) TL applies a quadratic temporal phase to an optical signal within a nonlinear FWM medium (such as an integrated photonic waveguide or a highly nonlinear optical fiber). By spectrally isolating the mixing product, termed the idler, and with appropriate lengths of dispersion prior to and after this FWM TL, a temporally magnified version of the input signal is generated. Therefore, the frequency shifts of PDV can be “slowed down” with the magnification factor M of the TL. M = 1 corresponds to a regular PDV system without a TL. M = 10 has been shown to be feasible for a TL-PDV system. The use of this effect for PDV can expand the velocity measurement range and allow for the use of lower bandwidth electronics. TL-PDV will open up new avenues for various dynamic material experiments.

47 OTHER INSTRUMENTATION↗

Channel simulation to facilitate mobile-satellite communications research

The mobile-satellite-service channel simulator, which is a facility for an end-to-end hardware simulation of mobile satellite communications links is discussed. Propagation effects, Doppler, interference, band limiting, satellite nonlinearity, and thermal noise have been incorporated into the simulator. The propagation environment in which the simulator needs to operate and the architecture of the simulator are described. The simulator is composed of: a mobile/fixed transmitter, interference transmitters, a propagation path simulator, a spacecraft, and a fixed/mobile receiver. Data from application experiments conducted with the channel simulator are presented; the noise converison technique to evaluate interference effects, the error floor phenomenon of digital multipath fading links, and the fade margin associated with a noncoherent receiver are examined. Diagrams of the simulator are provided.

Davarian, Faramaz↗

Estimations of model parameters for gravity wave spectra observed by MST radar

The general theory of MST radar observations of gravity wave spectra is developed. This effort extends the previous results to include anisotropy and Doppler effects for the spectra, as well as the consequences for the multibeam configuration. The relationships between the observed one- or two-dimensional spectra for the line-of-sight velocity in the gravity wave spectra are derived. Expressions for cross spectra, as well as covariances between velocities observed on different beams, are computed. Using these results, studies are carried out to show how model parameters for gravity wave spectra can be estimated from the observed quantities. Model parameters include the variance, power law indices, anisotropy parameters, Doppler parameters, mean scale sizes, etc. Cases with different numbers of beams are investigated.

Scheffler, A. O.↗

On the radiation mechanism of a uniformly moving charge

The radiation mechanism of a uniformly moving charge is discussed in detail with attention to the description of the Vavilov-Cherenkov and transition radiation effects. A well-grounded proof is given that this mechanism is incorrect because it is in conflict with the energy and momentum conservation laws and Newton’s first law. A lucid explanation of the mechanism for the Vavilov-Cherenkov radiation and the transition radiation is suggested by considering the atomic structure of solids, which does not require violation of fundamental laws. It is shown that the Vavilov-Cherenkov radiation and the transition radiation are emitted by the atoms of the medium that are polarized by the moving particle, rather than by the particle itself moving through a medium. It is obvious that in this case neither the anomalous nor the normal Doppler effect is possible in the process of the Vavilov-Cherenkov radiation emission. It is shown that the Vavilov-Cherenkov radiation and the transition radiation cannot be emitted at frequencies higher than the inner shell frequency of the atom of the medium. Mistakes caused by using the radiation mechanism of a uniformly moving charge for describing the interaction of a moving charge with a solid are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Method and system of doppler correction for mobile communications systems

Doppler correction system and method comprising receiving a Doppler effected signal comprising a preamble signal (32). A delayed preamble signal (48) may be generated based on the preamble signal (32). The preamble signal (32) may be multiplied by the delayed preamble signal (48) to generate an in-phase preamble signal (60). The in-phase preamble signal (60) may be filtered to generate a substantially constant in-phase preamble signal (62). A plurality of samples of the substantially constant in-phase preamble signal (62) may be accumulated. A phase-shifted signal (76) may also be generated based on the preamble signal (32). The phase-shifted signal (76) may be multiplied by the delayed preamble signal (48) to generate an out-of-phase preamble signal (80). The out-of-phase preamble signal (80) may be filtered to generate a substantially constant out-of-phase preamble signal (82). A plurality of samples of the substantially constant out-of-phase signal (82) may be accumulated. A sum of the in-phase preamble samples and a sum of the out-of-phase preamble samples may be normalized relative to each other to generate an in-phase Doppler estimator (92) and an out-of-phase Doppler estimator (94).

Georghiades, Costas N.↗

Characteristics of Airplanes and Helicopters Recorded by a Dense Seismic Array Near Anza California

We observe frequent air traffic events in continuous seismic waveforms recorded for about 30 days by 1,108 vertical geophones in a tight array on the San Jacinto fault zone. The waveforms of the air traffic events resemble tremor or collections of small earthquakes. However, time-frequency analysis reveals clear Doppler effects that can be modeled with basic equations and fitted well with parameters corresponding to airplanes and helicopters. The flying traces can be inverted by fitting the parameters at each station across the entire array. About 31 air traffic events are detected per day in the relatively remote study area, with peak activity from about 8:00 to 18:00 and significantly fewer events between 23:00 and 4:00 local time. The average event duration is about 200 s, so they cover together>7% of the day. To estimate the total time covered by earthquakes, we derive a scaling relation logτ(M) = 0.41M + 0.89 between earthquake duration and magnitudes using data of 266 earthquakes in the magnitude range 0 ≤ M ≤ 3. The results indicate that in most places, the duration of air traffic events is likely to exceed considerably the total time covered by earthquakes.

58 GEOSCIENCES↗

Spatio-temporal ion temperature and velocity measurements in a Z pinch using fast-framing spectroscopy

Ion Doppler spectroscopy (IDS) is a diagnostic technique that measures plasma ion temperature and velocity without perturbing the plasma with a physical probe. The ZaP-HD Flow Z-Pinch Experiment at the University of Washington uses this technique to resolve radial temperature and velocity profiles of a Z-pinch plasma. The pinch lifetime is approximately 100 ms, therefore diagnostics capable of sub-microsecond resolution are required to measure the evolution of temperature and velocity profiles. The previous IDS diagnostic system was only capable of collecting a single measurement during a plasma pulse. Here, an improved system has been developed to measure radially-resolved ion temperature and velocity for the entire Z-pinch lifetime. A Kirana 05M ultra-fast framing camera and SIL ultraviolet intensifier are used to record up to 100 spectra per plasma pulse. The temperature is computed from Doppler broadening of the carbon-III (229.687 nm) impurity ion radiation and the velocity from the Doppler shift of carbon-III. Measurements are able to resolve the evolution of the ion temperature and velocity over the course of a plasma pulse. The diagnostic has significantly reduced the number of pulses required and provides a more coherent measurement of plasma dynamics than the previous system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗