Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DISPLACEMENT GAGES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

121 records · Page 7

Computational Assessment of the Opening Mode Facesheet-to-Core Fracture Toughness of a Thin-Gage Facesheet Sandwich Structure

The single-cantilevered beam test (SCB) is currently being considered for standardization for measuring the opening mode fracture toughness of sandwich structures subjected to facesheet-to-core separation. At present, the Area method is considered the benchmark method for determining energy required to propagate the crack. This method is problematic since it requires periodic unloading and cannot be evaluated instantaneously. Therefore, a method is needed to accurately and instantaneously calculate opening mode fracture toughness. In previous work, SCB tests with thin-gauge facesheets were performed to compare the J-integral approach to data reduction methods including the Modified Beam Theory (MBT) and the Area method. Large deviations (over 10%) in the calculated fracture toughness were observed between the J-integral and MBT for large displacements. In this study, a simulated SCB experiment using a virtual crackclosure technique was performed to assess the previously observed discrepancies. The predicted load displacement response, the predicted angle at the load application point, and the predicted crack growth results are in good agreement (within 5%) with the corresponding experimental data. Using the predicted load and angles, the predicted J-integral is in good agreement (within 10%) with the experimentally obtained solution. Using the MBT approach, the previously observed deviations in the fracture toughness were determined to be associated with the empirical extrapolation procedure to estimate the crack-root rotation correction from nonlinear compliance curves. The nonlinear compliance is determined to be associated with large displacement effects observed within the predicted and experimental results.

Sandwich Composite↗

An Artificial-Intelligence and Machine-Learning-Based Methodology to Conduct Seemingly Strain-Controlled Fatigue Test in a Pressurized-Water-Reactor-Test-Loop-Autoclave, While Not Controlling the Strain

In general, low cycle fatigue analysis of pressurized water reactor (PWR) components, requires strain-controlled fatigue test data such as using strain versus life (ε–N) curves. Conducting strain-controlled fatigue tests under in-air conditions is not an issue. However, controlling strain in a PWR-test-loop-autoclave is a challenge, since an extensometer cannot be placed in a narrow autoclave (typically used in a high-temperature-pressure PWR-test-loop). This is due to lack of space inside an autoclave that houses the test specimen. In addition, installing a contact-type extensometer in the path of a high-pressure flow can be a challenge. These difficulties of using an extensometer inside an autoclave led us to use an outside-autoclave displacement sensor which measures the displacement of pull-rod-specimen assembly. However, in our study (based on in-air fatigue test data), we found that a pull-rod-controlled based fatigue test can lead to substantial cyclic hardening/softening resulting in substantially different cyclic strain amplitudes and their rates compared to the desired cyclic strain amplitudes and its rates. In this paper, we propose an Artificial-Intelligence and Machine-Learning based technique such as using k-means clustering technique to improve the pull-rod-control based fatigue test method, such that the gage-area strain amplitude and rates can reasonably be achieved. In support of this, we present the fatigue test results for both 316 SS base and 81/182 dissimilar-metal-weld specimens.

42 ENGINEERING↗

Back-Face Strain for Monitoring Stable Crack Extension in Precracked Flexure Specimens

Calibrations relating back-face strain to crack length in precracked flexure specimens were developed for different strain gage sizes. The functions were verified via experimental compliance measurements of notched and precracked ceramic beams. Good agreement between the functions and experiments occurred, and fracture toughness was calculated via several operational methods: maximum test load and optically measured precrack length; load at 2 percent crack extension and optical precrack length; maximum load and back-face strain crack length. All the methods gave vary comparable results. The initiation toughness, K(sub Ii) , was also estimated from the initial compliance and load.The results demonstrate that stability of precracked ceramics specimens tested in four-point flexure is a common occurrence, and that methods such as remotely-monitored load-point displacement are only adequate for detecting stable extension of relatively deep cracks.

Salem, Jonathan A.↗

Flow serration and shear-band propagation in bulk metallic glasses

Flow serration in bulk metallic glasses (BMGs) was analyzed using high-sensitivity strain gauges. Based on the displacement-time profile for one serration, shear-band propagating speed was determined and found to be insensitive to the applied strain rates. The disappearance of serration at high strain rates is a result that the signal of displacement burst was overwhelmed by the applied strain rate. In comparison with the ductile Pd-based and brittle Mg-based BMGs, the ductility of BMGs appears to be closely related to the dynamics during shear-band propagation.

36 MATERIALS SCIENCE↗

26th Space Simulation Conference Proceedings. Environmental Testing: The Path Forward

Topics covered include: A Multifunctional Space Environment Simulation Facility for Accelerated Spacecraft Materials Testing; Exposure of Spacecraft Surface Coatings in a Simulated GEO Radiation Environment; Gravity-Offloading System for Large-Displacement Ground Testing of Spacecraft Mechanisms; Microscopic Shutters Controlled by cRIO in Sounding Rocket; Application of a Physics-Based Stabilization Criterion to Flight System Thermal Testing; Upgrade of a Thermal Vacuum Chamber for 20 Kelvin Operations; A New Approach to Improve the Uniformity of Solar Simulator; A Perfect Space Simulation Storm; A Planetary Environmental Simulator/Test Facility; Collimation Mirror Segment Refurbishment inside ESA s Large Space; Space Simulation of the CBERS 3 and 4 Satellite Thermal Model in the New Brazilian 6x8m Thermal Vacuum Chamber; The Certification of Environmental Chambers for Testing Flight Hardware; Space Systems Environmental Test Facility Database (SSETFD), Website Development Status; Wallops Flight Facility: Current and Future Test Capabilities for Suborbital and Orbital Projects; Force Limited Vibration Testing of JWST NIRSpec Instrument Using Strain Gages; Investigation of Acoustic Field Uniformity in Direct Field Acoustic Testing; Recent Developments in Direct Field Acoustic Testing; Assembly, Integration and Test Centre in Malaysia: Integration between Building Construction Works and Equipment Installation; Complex Ground Support Equipment for Satellite Thermal Vacuum Test; Effect of Charging Electron Exposure on 1064nm Transmission through Bare Sapphire Optics and SiO2 over HfO2 AR-Coated Sapphire Optics; Environmental Testing Activities and Capabilities for Turkish Space Industry; Integrated Circuit Reliability Simulation in Space Environments; Micrometeoroid Impacts and Optical Scatter in Space Environment; Overcoming Unintended Consequences of Ambient Pressure Thermal Cycling Environmental Tests; Performance and Functionality Improvements to Next Generation Thermal Vacuum Control System; Robotic Lunar Lander Development Project: Three-Dimensional Dynamic Stability Testing and Analysis; Thermal Physical Properties of Thermal Coatings for Spacecraft in Wide Range of Environmental Conditions: Experimental and Theoretical Study; Molecular Contamination Generated in Thermal Vacuum Chambers; Preventing Cross Contamination of Hardware in Thermal Vacuum Chambers; Towards Validation of Particulate Transport Code; Updated Trends in Materials' Outgassing Technology; Electrical Power and Data Acquisition Setup for the CBER 3 and 4 Satellite TBT; Method of Obtaining High Resolution Intrinsic Wire Boom Damping Parameters for Multi-Body Dynamics Simulations; and Thermal Vacuum Testing with Scalable Software Developed In-House.

Packard, Edward A.↗

X-ray beam method for displacement measurement in hostile environments

A new method of extensometry using an X-ray beam was devised, and the results of current testing reveal it to be highly feasible. This technique has been shown to provide a non-contacting system that is immune to problems associated with density variations in gaseous environments, that plague currently available optical methods. This advantage is a result of the non-refracting penetrating nature of X-rays. The method is based on X-ray-induced X-ray fluorescence of targets, which subsequently serve as fudicial markers. Some target materials have melting points over 1600 degrees C which will facilitate measurement at extremely high temperatures. A highly focused intense X-ray beam, which is produced using a Johansen 'bent crystal', is then scanned across the target, which responds by fluorescing X-rays when stimulated by the incident beam. This secondary radiation is monitored using a detector. By carefully measuring beam orientation, change in target edge position can be determined. Many variations on this basic theme are now possible such as two targets demarcating a gage length, or a beam shadowing method using opaque targets.

Jordan, Eric H.↗

Experimental Validation of FE/BEM Dynamic Strain Model Under Diffuse Acoustic Field Loading

Structural finite element (FE) models naturally output displacement or acceleration response data. However, they can also be used to compute stress, internal forces, and strain response. When coupled with a boundary element model (BEM) of the fluid surrounding the structure, a fully coupled analysis can be performed. Modeling a diffuse acoustic field in the BEM fluid provides an excitation like that found when the structure is placed in a reverberation chamber. Fully coupling the structural FE model to the acoustic BEM model provides a means to predict not only the acceleration response of the panel to diffuse field loading, but also the ability to predict the dynamic stress and strain response. This type of model has been available with current predictive tools, but experimental validation of the prediction of dynamic stress or strain is difficult to find. An aluminum panel was instrumented with accelerometers and strain gages and hung in a reverberation room and subjected to a diffuse acoustic field. This paper presents the comparison of the experimental and predicted results.

Tsoi, W. Ben↗

Fuel cladding post-quench LOCA embrittlement: mechanical test relevance

During a loss-of-coolant-accident (LOCA), the fuel cladding is submitted to a high temperature increase in a steam environment, along with an internal pressure increase which would eventually lead to ballooning and burst of the cladding. Steam could then penetrate through the burst opening and lead to inner surface oxidation and secondary-hydriding of the cladding. Post-quench cladding rupture can then occur either in two-sided oxidized area with wall thinning due to ballooning, or in single-sided oxidized area with large hydrogen content. Common tests involved in the evaluation of the post-quench ductility are Ring Compression Tests (RCT), Expansion Due to Compression Test (EDC) or Axial Tensile Tests (AT). Questions arise about these mechanical tests, as for instance, the influence on sample failure of the oxide layer thickness partitioning between inner and outer diameter. A systematic study was carried out to compare several mechanical tests on both single-sided and two-sided Zircaloy-4 oxidized samples. Five different mechanical tests were compared, including RCT: C-shaped ring Compression Test (CCT), Axial Tensile test (AT), Ring Tensile Test with well-defined machined gage section (RTT) and plain Ring Tensile Test (pRTT). All samples were taken from cladding tubes which had been oxidized in steam at 1200 Celsius degrees and then water-quenched. Mechanical tests were performed at room temperature and two to three samples were tested for each oxidation conditions and for every sample geometry to assess the reproducibility. Metallographic examinations were carried out to measure the ZrO{sub 2} and αZr(O) layer thicknesses and the ex-β/α(O) phase fraction. Mean hydrogen content measurements were also performed systematically on each sample. Results indicate that the different mechanical tests have not the same sensitivity to the oxide layer partitioning: RTT and pRTT load at failure seems to depend mainly on the cumulated oxide layer thickness rather than on its partitioning, whereas this parameter has an impact on CCT and AT test results. For all tensile tests, stresses at failure were derived from load-displacement curves. The failure of brittle samples was assumed to be governed by linear elastic fracture mechanics. Using conventional stress intensity factor solution, a value of the material fracture toughness controlling the sample failure was determined from experimental results and discussed. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Wind Tunnel Measurements of the Wake of a Full-Scale UH-60A Rotor in Forward Flight

A full-scale UH-60A rotor was tested in the National Full-Scale Aerodynamics Complex (NFAC) 40- by 80-Foot Wind Tunnel in May 2010. The test was designed to acquire a suite of measurements to validate state-of-the-art modeling tools. Measurements include blade airloads (from a single pressure-instrumented blade), blade structural loads (strain gages), rotor performance (rotor balance and torque measurements), blade deformation (stereo-photogrammetry), and rotor wake measurements (Particle Image Velocimetry (PIV) and Retro-reflective Backward Oriented Schlieren (RBOS)). During the test, PIV measurements of flow field velocities were acquired in a stationary cross-flow plane located on the advancing side of the rotor disk at approximately 90 deg rotor azimuth. At each test condition, blade position relative to the measurement plane was varied. The region of interest (ROI) was 4-ft high by 14-ft wide and covered the outer half of the blade radius. Although PIV measurements were acquired in only one plane, much information can be gleaned by studying the rotor wake trajectory in this plane, especially when such measurements are augmented by blade airloads and RBOS data. This paper will provide a comparison between PIV and RBOS measurements of tip vortex position and vortex filament orientation for multiple rotor test conditions. Blade displacement measurements over the complete rotor disk will also be presented documenting blade-to-blade differences in tip-path-plane and providing additional information for correlation with PIV and RBOS measurements of tip vortex location. In addition, PIV measurements of tip vortex core diameter and strength will be presented. Vortex strength will be compared with measurements of maximum bound circulation on the rotor blade determined from pressure distributions obtained from 235 pressure sensors distributed over 9 radial stations.

Wadcock, Alan J.↗

NASA Tech Briefs, November 2011

The topics include: 1) Flight Test Results from the Rake Airflow Gage Experiment on the F-15B; 2) Telemetry and Science Data Software System; 3) CropEx Web-Based Agricultural Monitoring and Decision Support; 4) High-Performance Data Analysis Tools for Sun-Earth Connection Missions; 5) Experiment in Onboard Synthetic Aperture Radar Data Processing; 6) Microfabrication of a High-Throughput Nanochannel Delivery/Filtration System; 7) Improved Design and Fabrication of Hydrated-Salt Pills; 8) Monolithic Flexure Pre-Stressed Ultrasonic Horns; 9) Cryogenic Quenching Process for Electronic Part Screening; 10) Broadband Via-Less Microwave Crossover Using Microstrip-CPW Transitions; 11) Wheel-Based Ice Sensors for Road Vehicles; 12) G-DYN Multibody Dynamics Engine; 13) Multibody Simulation Software Testbed for Small-Body Exploration and Sampling; 14) Propulsive Reaction Control System Model; 15) Licklider Transmission Protocol Implementation; 16) Core Recursive Hierarchical Image Segmentation; 17) Two-Stage Centrifugal Fan; 18) Combined Structural and Trajectory Control of Variable-Geometry Planetary Entry Systems; 19) Pressure Regulator With Internal Ejector Circulation Pump, Flow and Pressure Measurement Porting, and Fuel Cell System Integration Options; 20) Temperature-Sensitive Coating Sensor Based on Hematite; 21) Standardization of a Volumetric Displacement Measurement for Two-Body Abrasion Scratch Test Data Analysis; 22) Detection of Carbon Monoxide Using Polymer-Carbon Composite Films; 23) Substituted Quaternary Ammonium Salts Improve Low-Temperature Performance of Double-Layer Capacitors; 24) Sustainably Sourced, Thermally Resistant, Radiation Hard Biopolymer; 25) Integrated Lens Antennas for Multi-Pixel Receivers; 26) 180-GHz Interferometric Imager; 27) Maturation of Structural Health Management Systems for Solid Rocket Motors; 28) Validating Phasing and Geometry of Large Focal Plane Arrays; 29) Transverse Pupil Shifts for Adaptive Optics Non-Common Path Calibration; 30) Qualification of Fiber Optic Cables for Martian Extreme Temperature Environments; 31) Solid-State Spectral Light Source System; 32) Multiple-Event, Single-Photon Counting Imaging Sensor; 33) Surface Modeling to Support Small-Body Spacecraft Exploration and Proximity Operations; and 34) Achieving Exact and Constant Turnaround Ratio in a DDS-Based Coherent Transponder.

Source record↗

Out-of-Plane Restraint under Tension In-Plane Loading

The development and description of a test fixture designed to restrict out-of-plane motion in the center region of tension-loaded carbon-epoxy panels are presented herein. The test fixture was used to impose displacement conditions consistent with those in an analytical tool being developed to predict panel behavior in the vicinity of a central notch, which included the assumption that there would be no out-of-plane displacement and no buckling. However, pretest analysis using finite element models for a panel loaded without any out-of-plane restraint in the region of the notch indicated that with an imperfection magnitude equal to 20 percent of the thickness of the thin-skin panel, an unacceptable amount of out-of-plane deformation would occur as Poisson effects induced compression loads in the region of the notch. Therefore, to validate this tool in a test program, a restraint fixture which would suppress out-of-plane motion was required. The panel could not be encased in restraining plates because instrumentation and visibility were required in the vicinity of the notch. Therefore, a fixture that would restrict out-of-plane motion while still allowing access to the surface of the panel at the notch edges for instrumentation and line-of-sight access for cameras was required. To satisfy these requirements, a fixture was designed to restrict only out-of-plane motion near the center of the notch. Two 1.78-m-long test panels were loaded in tension to failure using this fixture. Out-of-plane deformations were not directly measured during testing, so back-to-back strain gages were used to obtain an indication of buckling. Strain results indicated that the restraint fixture performed as designed and buckling did not occur.

Fixtures↗

Out-of-Plane Restraint under Tension In-Plane Loading

The development and description of a test fixture designed to restrict out-of-plane motion in the center region of tension-loaded carbon-epoxy panels are presented herein. The test fixture was used to impose displacement conditions consistent with those in an analytical tool being developed to predict panel behavior in the vicinity of a central notch, which included the assumption that there would be no out-of-plane displacement and no buckling. However, pretest analysis using finite element models for a panel loaded without any out-of-plane restraint in the region of the notch indicated that with an imperfection magnitude equal to 20 percent of the thickness of the thin-skin panel, an unacceptable amount of out-of-plane deformation would occur as Poisson effects induced compression loads in the region of the notch. Therefore, to validate this tool in a test program, a restraint fixture which would suppress out-of-plane motion was required. The panel could not be encased in restraining plates because instrumentation and visibility were required in the vicinity of the notch. Therefore, a fixture that would restrict out-of-plane motion while still allowing access to the surface of the panel at the notch edges for instrumentation and line-of-sight access for cameras was required. To satisfy these requirements, a fixture was designed to restrict only out-of-plane motion near the center of the notch. Two 1.78-m-long test panels were loaded in tension to failure using this fixture. Out-of-plane deformations were not directly measured during testing, so back-to-back strain gages were used to obtain an indication of buckling. Strain results indicated that the restraint fixture performed as designed and buckling did not occur.

Composite structures↗

Damage Detection of CFRP Plates by Full-Spectral Analysis of a Fibre Bragg Grating Sensor Signal

This paper describes the measurement of average strain, strain distribution and vibration of cantilever beam made of Carbon Fiber Reinforced Plastics (CFRP), using a single Fibre Bragg Grating (FBG) sensor mounted on the beam surface. Average strain is determined from the displacement of the peak wavelength of reflected light from the FBG sensor. Unstrained reference FBG sensors were used to compensate for temperature drift and the photoelastic coefficient (P{sub e}), which was used to calculate the gauge factor. Measured strains agree with those measured by a resistance foil strain gauge attached to the sample. Stress distributions are measured by monitoring the variation in the full width half maximum (FWHM) values of the reflected spectrum, using a proposed optical analytical model, described in the paper. FWHM values were measured for both the cantilever test beam and a for a reference beam, loaded using a four-point bending rig. The trend of the stress distribution for the test beam matches with our analytical model, however with a relatively large noise present in the experimentally determined data. The vibration of cantilever beam was measured by temporal analysis of the peak reflection wavelength. This technique is very stable as measurements are not affected by variations in the signal amplitude. Finally an application of FBG sensors for damage detection of CFRP plates is demonstrated, by measuring the average strain and natural frequency. With small defects of different sizes applied to the CFRP plate, average strains were seen to increase with damage size and the natural frequency decreased with damage size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗