Burst diaphragm leak detector
New method replaces flowmeter approach with readily available burst diaphragm leak detector assembly mounted to all drain ports. This allows simultaneous leak detection of all flange seals under operating conditions.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
New method replaces flowmeter approach with readily available burst diaphragm leak detector assembly mounted to all drain ports. This allows simultaneous leak detection of all flange seals under operating conditions.
Image converter camera and astronomical telescope arrangement for photographing metal diaphragm openings in shock tube
Reinforcing beam system for highly flexible diaphragms in valves or pressure switches
Piezoelectric sensing diaphragm for detection of micrometeorites in space, noting vibration mode and effect of small beads contact time on calibration errors
Diffused diaphragm pressure sensors in impact probes used in wind tunnel tests of dynamic response of supersonic air induction systems
Self opening em-operated secondary and ternary mylar diaphragms for expansion tubes and tunnels
Vibrating diaphragm gas pressure measuring system based on membrane damping, applying to prototype atmospheric entry probes
Transducer measures gas pressure profiles in high temperature, short duration, gas flows usually found in devices where pressure pulses may have durations of few microseconds to several milliseconds. Assembly includes fluid delay line, delay chamber, and flow restrictor for equalizing steady state pressure on diaphragm's sides
Knife structure for controlling rupture of shock tube diaphragms
Burst diaphragm flow initiator for installation in short duration wind tunnels
Semitoroidal diaphragm cavitating flow control valve
Magnetically opened diaphragm design with camera shutter and expansion tube applications
Design and development of inertia diaphragm pressure transducer
A method of distributing fuel equally to a plurality of spray nozzles in a gas-turbine engine by means of balanced-diaphragm fuel distributors is presented. The experimental performance of three of eight possible distributor arrangements are discussed. An analysis of all eight arrangements is included. Criterions are given for choosing a fuel-distributor arrangement to meet specific fuel-system requirements of fuel-distribution accuracy, spray-nozzle pressure variations, and fuel-system pressures. Data obtained with a model of one distributor arrangement indicated a maximum deviation from perfect distribution of 3.3 percent for a 44 to 1 range (19.5 to 862 lb/hr) of fuel-flow rates. The maximum distributor pressure drop was 125 pounds per square inch. The method used to obtain the required wide range of flow control in the distributor valves consisted in varying the length of a constant-area flow path.
A general method is presented for solving problems encountered in the analysis of Iris diaphragm photometer (IDP) data. The method is used to derive the general shape of the calibration curve, allowing both a more accurate fit to the IDP data for comparison stars and extrapolation to magnitude ranges for which no comparison stars are measured. The profile of starlight incident and the characteristic curve of the plate are both assumed and then used to derive the profile of the star image. An IDP reading is then determined for each star image. A procedure for correcting the effects of a nonconstant background fog level on the plate is also demonstrated. Additional applications of the method are made in the appendix to determine the relation between the radius of a photographic star image and the star's magnitude, and to predict the IDP reading of the 'point of optimum density'.
The objective of this project was to develop high-temperature pressure sensors using non-metallic components and optical sensing methods. The sensors are to operate over a temperature range from room temperature approx. 20C to 540C, to respond to internal pressure up to 690 kPa, to respond to external pressure up to 690 kPa, and to withstand external overpressure of 2070 kPa. Project tasks include evaluating sensing techniques and sensor systems. These efforts include materials and sensing method selection, sensor design, sensor fabrication, and sensor testing. Sensors are tested as a function of temperature, pressure, overpressure, and vibration. The project results show that high-temperature pressure sensors based on glass components and optical sensing methods are feasible. The microbend optical diaphragm deflection sensor exhibits the required sensitivity and stability for use as a pressure sensor with temperature compensation. for the microbend sensor, the 95% confidence level deviation of input pressure from the pressure calculated from the overall temperature-compensated calibration equation is 3.7% of full scale. The limitations of the sensors evaluated are primarily due to the restricted temperature range of suitable commercially available optical fibers and the problems associated with glass-to-metal pressure sealing over the entire testing temperature range.
The extent of the region of the diaphragm around the esophagus that displays greatly reduced activity during the expulsive phase of vomiting was determined from electromyographic studies in cats to be about 0.75-1.0 cm from the esophagus. Horseradish peroxidase injected into this region retrogradely labeled motoneurons throughout most of the rostral-caudal extent of the phrenic nucleus, with the exception of caudal C6 and rostral C7. This widespread intermingling of motoneurons that innervate the region of reduced activity with other phrenic motoneurons creates a difficulty for needed follow-up studies of diaphragmatic control during vomiting.
This paper reports on the status of several ongoing development programs aimed at the demonstration of diaphragm Stirling cycle cryocooler performance. Key attributes of this technology focus on long reliable operating life and excellent efficiency, making it a candidate for cooling of satellite-borne long wavelength sensors for astrophysics and earth observing missions. Three programs are described, each leading to system or component test hardware: a 2 W 65 K single-stage Standard Spacecraft Cryocooler, a 300 mW 30 K two-stage cooler and a 200 mW 4-20 K single-stage cooler. Design features are described, and breadboard experimental data are presented.