SEARCH · Engineering Papers
Results for “DIAGNOSIS”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Burden of bacterial bloodstream infections and recent advances for diagnosis
Abstract Bloodstream infections (BSIs) and subsequent organ dysfunction (sepsis and septic shock) are conditions that rank among the top reasons for human mortality and have a great impact on healthcare systems. Their treatment mainly relies on the administration of broad-spectrum antimicrobials since the standard blood culture-based diagnostic methods remain time-consuming for the pathogen's identification. Consequently, the routine use of these antibiotics may lead to downstream antimicrobial resistance and failure in treatment outcomes. Recently, significant advances have been made in improving several methodologies for the identification of pathogens directly in whole blood especially regarding specificity and time to detection. Nevertheless, for the widespread implementation of these novel methods in healthcare facilities, further improvements are still needed concerning the sensitivity and cost-effectiveness to allow a faster and more appropriate antimicrobial therapy. This review is focused on the problem of BSIs and sepsis addressing several aspects like their origin, challenges, and causative agents. Also, it highlights current and emerging diagnostics technologies, discussing their strengths and weaknesses.
Strobed imaging as a method for the determination and diagnosis of local seeing
ABSTRACT The image quality budget of many telescopes can have substantial contributions from local seeing, both ‘mirror’ and ‘dome’, which arise from turbulence and temperature variations that are difficult to quantify, measure directly, and ameliorate. We describe a method to determine the ‘local’ seeing degradation due to wavefront perturbations within the final few metres of the optical path from celestial sources to the focal plane of a ground-based telescope, using the primary instrument and along the same path taken by light from celestial sources. The concept involves placing strobed emitters along the light path to produce images on the main focal plane that ‘freeze’ different realizations of index perturbations. This method has the advantage of measuring directly the image motion and scintillation imparted by the dynamic spatial and temporal structure of local perturbations in the index of refraction along the light path, with a clean separation from seeing induced in the atmosphere above the dome. The strobed-source approach allows for rapid image motion and scintillation to be measured directly on the focal plane, even for large-aperture telescopes with wide-field instruments and slow shutters, such as that being constructed for the Rubin Observatory. A conceptual design is presented that uses the ‘guider’ CCDs in the Rubin telescope focal plane to make local-seeing measurements on demand, perhaps even during science exposures.
Diagnosis of 3D magnetic field and mode composition in MHD turbulence with Y -parameter
ABSTRACT Magnetic fields are crucial in numerous astrophysical processes within the interstellar medium (ISM). However, the detailed determination of magnetic field geometry is notoriously challenging. Based on the modern magnetohydrodynamic (MHD) turbulence theory, we introduce a novel statistical technique, the ‘Y-parameter’, to decipher the magnetic field inclination in the ISM and identify dominant turbulence modes. The Y-parameter, calculated as the ratio of anisotropies of different Stokes parameter combinations, displays contrasting trends with the mean-field inclination angle in Alfvénic and compressible turbulence modes. A Y-parameter value around 1.5 ± 0.5 provide a statistical boundary to determine the dominant MHD turbulence modes. We have discovered specific correlations between the Y-parameter value and the inclination angle that unveil the dominant turbulence mode. This methodology, when applied to future radio polarization surveys such as LOFAR and SKA, promises to significantly enhance our knowledge of 3D magnetic field in the ISM and improve our understanding of interstellar turbulence.
Microscopic diagnosis of universal geometric responses in fractional quantum Hall liquids
Topological quantum liquids contain internal degrees of freedom that are coupled to geometric response. Yet, an explicit and microscopic identification of the geometric response remains difficult. Here, taking notable fractional quantum Hall (FQH) states as typical examples, we systematically investigate a promising protocol—the Dehn-twist deformation on the torus geometry—to probe the geometric response of correlated topological states and establish the relation between such response and universal properties of pertinent states. Based on analytical derivations and numerical simulations, we find that the geometry-induced Berry phase encodes features for a broad class of FQH states at the Laughlin, hierarchy, Halperin and non-Abelian Moore-Read fillings. Our findings conclusively demonstrate that the adiabatic Dehn-twist deformation can faithfully capture rich geometric and topological information, including the Hall viscosity and topological spin of the pertinent FQH state and the chiral central charge of the underlying edge conformal field theory. Our approach provides a powerful way to reveal topological orders of generic FQH states and address previously open questions.
Diagnosis of information scrambling from Hamiltonian evolution under decoherence
We apply a quantum teleportation protocol based on the Hayden-Preskill thought experiment to quantify how scrambling a given quantum evolution is. It has an advantage over the direct measurement of out-of time ordered correlators when used to diagnose the information scrambling in the presence of decoherence effects stemming from a noisy quantum device. We demonstrate the protocol by applying it to two physical systems: Ising spin chain and SU(2) lattice Yang-Mills theory. To this end, we numerically simulate the time evolution of the two theories in the Hamiltonian formalism. The lattice Yang-Mills theory is implemented with a suitable truncation of Hilbert space on the basis of the Kogut-Susskind formalism. On a two-leg ladder geometry and with the lowest nontrivial spin representations, it can be mapped to a spin chain, which we call Yang-Mills-Ising model and is also directly applicable to future digital quantum simulations. Here, we find that the Yang-Mills-Ising model shows the signal of information scrambling at late times.
Single-Shot Diagnosis of Electron Energy Evolution via Streaked Betatron X Rays in a Curved Laser Wakefield Accelerator
We report on an experimental observation of the streaking of betatron x rays in a curved laser wakefield accelerator. The streaking of the betatron x rays was realized by launching a laser pulse into a plasma with a transverse density gradient. By controlling the plasma density and the density gradient, we realized the steering of the laser driver, electron beam, and betatron x rays simultaneously. Furthermore, we observed an energy-angle correlation of the streaked betatron x rays and utilized it in diagnosing the electron acceleration process in a single-shot mode. Our work could also find applications in advanced control of laser beam and particle propagation. More importantly, the angular streaked betatron x ray has an intrinsic spatiotemporal correlation, which makes it a promising tool for single-shot pump-probe applications.
Total Unwrapped Phase-Based Diagnosis of Wall Thinning in Nuclear Power Plants Secondary Piping Structures
Not Available
ALBADross: Active Learning Based Anomaly Diagnosis for Production HPC Systems.
Abstract not provided.
LDMS Darshan Connector: For Run Time Diagnosis of HPC Application I/O Performance.
Abstract not provided.
Knowledge-Based Fault Diagnosis for a Distribution System with High PV Penetration.
Abstract not provided.
Diagnosis of PV Cell Antireflective Coating Degradation Resulting From Hot-Humid High-Voltage Potential Aging
Corrosion of the antireflective coating on a photovoltaic cell ("ARc corrosion") has previously been observed in studies using hot-humid test conditions with external high-voltage (HV) bias. This study primarily focuses on known vulnerable legacy aluminum back surface field cells in mini-modules (MiMos) put through comparative stepped stress tests. Each cell type had MiMos at +1500 V, -1500 V, or unbiased ("Voc") potential, which were sequentially subjected to test conditions of 60 degrees C/60% relative humidity (RH) for 96 h, as in International Electrotechnical Commission Technical Specification 62804-1; 70 degrees C/70% RH for 200 h; and 85 degrees C/85% RH for 200 h. Characterizations at each step included visual camera and electroluminescence (EL) imaging, colorimetry, and current-voltage curve tracing. Final characterizations included: Suns-Voc, spatial mapping of external quantum efficiency, high-resolution photoluminescence, EL, and dark lock-in thermography imaging. Forensics were performed on extracted cores, including scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy, and scanning Auger microscopy (SAM). Forensics were also conducted on MiMos from previous studies that underwent stepped HV aging and separate outdoor aged full-sized modules. ARc corrosion was specifically seen for the glass/encapsulant/cell side of the +1500 V (HV+) stressed MiMos and modules. Appearance, color, and reflectance were the most distinguishing characteristics relative to glass corrosion, gridline corrosion and delamination, and other concurrent degradation modes. SEM/EDS and SAM identified the conversion of silicon nitride to hydrated silica, hydrous silica, or hydrated amorphous silica, which preferentially occurred at the edges and tips of the pyramidal textured cell surface.
Diagnosis of PV Cell Passivation Degradation Resulting from Hot-Humid, High Voltage Potential Aging
Corrosion of the antireflective coating on the cell ("AR c corrosion") was previously observed in studies using hot-humid test conditions with external high voltage (HV) bias. Because AR c corrosion is not well understood, mini-modules (MiMos) were examined in a comparative experiment using PERC and PERT as well as legacy Al-BSF cells. For separate MiMos with the cell circuit electrical at +1500 V, -1500 V, or unbiased "V oc", test conditions in the comparative study included 60degrees C/60% RH for 96 h, as in IEC TS 62804-1; 70degrees C/70%RH for 200 h; and 85degrees C/85% RH for 200 h. Characterizations at each read point included: camera and electroluminescence (EL) imaging, colorimetry, and I-V curve tracing. Characterizations at the final read point included: SunsVoc; spatially mapping external quantum efficiency (EQE); high resolution: photoluminescence (PL), EL, and dark lock-in thermographic (DLIT) imaging. Forensics were performed on extracted cores, including scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS) and scanning Auger microscopy (SAM). Forensics were also conducted on MiMos (stepped HV aging) and full-sized modules (outdoor aging) from previous studies. AR c corrosion was specifically observed for the glass/encapsulant/cell side of +1500 V (HV+) stressed MiMos, where appearance, color, and reflectance were the characteristics most distinguished relative to simultaneously occurring degradation modes. SEM/EDS and SAM identified conversion of silicon nitride to silicon oxide or hydrous silica, preferentially occurring at the edges and tips of the pyramidal textured cell surface.
Imperceptible Attacks on Fault Detection and Diagnosis Systems in Smart Buildings
Not provided.
Perturbation-Based Diagnosis of False Data Injection Attack Using Distributed Energy Resources
Modern smart grid relies on various sensor measurements for its operational control. In a successful false data injection attack, the attacker manipulates the measurements from the grid sensors such that undetected errors are introduced into the estimates of the system parameters leading to catastrophic situations. This paper proposes a novel perturbation based false data injection attack detection mechanism that utilizes inverter based distributed energy resources (DERs) to create low magnitude perturbation signal in the distribution system voltage that is inconsequential to the normal grid operation. Two voltage sensitivity analysis based algorithms are designed to identify the optimal set of DERs that can create the voltage perturbation signal of desired magnitude. An analytical method of voltage sensitivity analysis is used to compute the magnitude of voltage perturbation signal at each node in a computationally efficient manner. Then, a detection mechanism is developed that checks for the presence of the perturbation sequence in each sensor measurement. A sensor measurement is deemed authentic if the voltage perturbation signal is present in the data. In case of sensor malfunction or cyber-attack, the perturbation signal will not be present in the measurement data. Performance of the proposed attack detection mechanism is validated via simulation of the IEEE 69 bus test system.
Evaluation of a laboratory-developed multiplex real-time PCR assay for diagnosis of syphilis, herpes and chancroid genital ulcers in four public health laboratories in the USA
Objective To evaluate the field performance of a multiplex PCR (M-PCR) assay for detection of herpes simplex virus (HSV)-1 and HSV-2, Treponema pallidum ( T. pallidum ) and Haemophilus ducreyi ( H. ducreyi ) in genital ulcer disease (GUD) specimens. Methods GUD M-PCR was performed on 186 remnant specimens, previously collected for HSV testing, by four public health laboratories (PHLs) and the Laboratory Reference and Research Branch (LRRB) at the Centers for Disease Control and Prevention. The results from the PHLs were compared with those of LRRB, which served as the reference testing method, and percentage agreement was calculated. Results HSV was detected in 31 of 52 (59.6%), 20 of 40 (50%), 43 of 44 (97.7%) and 19 of 50 (38.0%) specimens from PHL1, PHL2, PHL3 and PHL4, respectively. There were seven discrepant results for HSV, and the overall percent agreement between the PHLs and the LRRB was 94%–100%, with a kappa value of 0.922, which demonstrates high agreement. T. pallidum was identified in 7 of 51 (13.7%) specimens from PHL1 with 94.1% agreement and in 2 of 40 (5.0%) specimens from PHL2 with 100% agreement. The LRRB identified three additional T. pallidum -positive specimens from PHL1. The kappa value (0.849) for T. pallidum testing suggests good agreement. Consistent with the LRRB results, no T. pallidum was detected in specimens from PHL3 and PHL4, and H. ducreyi was not detected at any of the study sites. Conclusions The GUD M-PCR assay performed well in four independent PHLs and 12 suspected syphilis cases were identified in this study. The M-PCR assay could provide improved diagnostic options for GUD infections in state and local PHLs.