Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Recovery of coincident frequency domain multiplexed detector pulses using sequential deconvolution

Multiplexing of radiation detector signals into a single channel significantly reduces the need for a large number of digitizer channels, which reduces the cost and the power consumption of a data acquisition system. We previously demonstrated frequency domain multiplexing by convolution using a prototype system that multiplexed two EJ-309 organic scintillators signals into a single channel. Each detector pulse was converted to a damped sinusoid which was then combined into a single channel. The combined signal was digitized and the original detector signal was recovered from the damped sinusoid by deconvolution. In this paper, we demonstrate the recovery of multiple detector signals that arrive during the same digitized record via a new sequential deconvolution method. Here, when two detectors produce signals in the same digitized record and their pulses do not overlap in time, we found that the charge, arrival time, and particle type can be estimated fairly precisely for the first pulse, but the second pulse exhibits substantial degradation in the precision of the estimated charge and arrival time. When the pulses overlap in time, we demonstrate both theoretically and experimentally that the part of the first pulse that does not overlap with the second can be recovered accurately, so the arrival time and amplitude of the first pulse can be estimated fairly precisely, but not the charge or particle type. None of these quantities can be estimated precisely for the second pulse when the two pulses overlap.

47 OTHER INSTRUMENTATION↗

Setting the threshold for high throughput detectors: A mathematical approach for ensembles of dynamic, heterogeneous, probabilistic anomaly detectors

Cyber operations now manage a high volume of heterogeneous log data. Anomaly Detection (AD) in such operations involves multiple (e.g., per IP, per data type) ensembles of detectors modeling heterogeneous characteristics (e.g., rate, size, type) often with adaptive online models producing alerts in near real time. Because of the high data volume, setting the threshold for each detector in such a system is an essential yet underdeveloped configuration issue that, if slightly mistuned, can leave the system useless, either producing a myriad of alerts (and flooding downstream systems) or giving none. In this work, we build on the foundations of Ferragut et al. to provide a set of rigorous results for understanding the relationship between threshold values and alert quantities for probabilistic detectors. This informs an algorithm for setting the threshold of multiple, heterogeneous, possibly dynamic detectors completely a priori, in principle. Indeed, if the underlying distribution of the incoming data is known, the algorithm provides provably manageable thresholds. If the distribution is unknown (poorly estimated), our analysis gives insight into how the model distribution differs from the actual distribution, indicating refitting is necessary. We provide empirical experiments, regulating the alert rate of a system with ≈2,500 adaptive detectors scoring over 1.5M events in 5 hours of timestamps. Further, we demonstrate on real network data and detection framework of Harshaw et al. the alternative case, demonstrating that the inability to regulate alerts indicates how the detection model is not a good fit to the data.

Bridges, Robert↗

Novel Light Detectors for Directional MeV scale DM Detectors

The search for sub-GeV dark matter requires novel detector development due to the small expected ionization signal and large backgrounds, many of which still need to be well-modeled. For this reason, to unambiguously detect dark matter, a detector must be able to determine the directionality of the incoming particles so that the daily modulation of the rate can be used to confirm a dark matter signal. This can be accomplished by combining anisotropic scintillating crystals, such as trans-Stilbene, as a detector target, with an optically-sensitive Skipper CCD as a readout. I will present on my work over the past six months developing the first prototype of this detector, including optical testing of the trans-Stilbene and design of the detector. This work will lead to characterization of the CCDs and deployment of the first prototype later this year.

Hoch, Nora [MIT]↗

Charged Particle Induced Radiation damage of Germanium Detectors in Space: Two Mars Observer Gamma-Ray Detectors

The Mars Observer Gamma-Ray Spectrometer (MO GRS) was designed to measure gamma-rays emitted by the Martian surface. This gamma-ray emission is induced by energetic cosmic-ray particles penetrating the Martian surface and producing many secondary particles and gamma rays. The MO GRS consisted of an high-purity germanium (HPGe) detector with a passive cooler. Since radiation damage due to permanent bombardment of energetic cosmic ray particles (with energies up to several GeV) was expected for the MO GRS HPGe crystal, studies on radiation damage effects of HPGe crystals were carried on earth. One of the HPGe crystals (paradoxically called FLIGHT) was similar to the MO GRS crystal. Both detectors, MO GRS and FLIGHT, contained closed-end coaxial n-type HPGe crystals and had the same geometrical dimensions (5.6 x 5.6 cm). Many other parameters, such as HV and operation temperature, differed in space and on earth, which made it somewhat difficult to directly compare the performance of both detector systems. But among other detectors, detector FLIGHT provided many useful data to better understand radiation damage effects.

Bruekner, J.↗

Calibration Improvements in the Detector-to-Detector Differences for the MODIS Ocean Color Bands

The Moderate Resolution Imaging Spectroradiometer (MODIS), a major instrument within NASAs Earth Observation System missions, has operated for over 16 and 14 years onboard the Terra and Aqua satellites, respectively. Its reflective solar bands (RSB) covering a spectral range from 0.4 to 2.1 micrometers are primarily calibrated using the on-board solar diffuser(SD), with its on-orbit degradation monitored using the Solar Diffuser Stability Monitor. RSB calibrations are supplemented by near-monthly lunar measurements acquired from the instruments space-view port. Nine bands (bands 8-16) in the visible to near infrared spectral range from 0.412 to 0.866 micrometers are primarily used for ocean color observations.During a recent reprocessing of ocean color products, performed by the NASA Ocean Biology Processing Group, detector-to-detector differences of up to 1.5% were observed in bands 13-16 of Terra MODIS. This paper provides an overview of the current approach to characterize the MODIS detector-to-detector differences. An alternative methodology was developed to mitigate the observed impacts for bands 13-16. The results indicated an improvement in the detector residuals and in turn are expected to improve the MODIS ocean color products. This paper also discusses the limitations,subsequent enhancements, and the improvements planned for future MODIS calibration collections.

Li, Yonghong↗

Fabrication of Detector Arrays for the SPT-3G Receiver

The South Pole Telescope third-generation (SPT-3G) receiver was installed during the austral summer of 2016–2017. It is designed to measure the cosmic microwave background across three frequency bands centered at 95, 150, and 220 GHz. The SPT-3G receiver has ten focal plane modules, each with 269 pixels. Each pixel features a broadband sinuous antenna coupled to a niobium microstrip transmission line. In-line filters define the desired band-passes before the signal is coupled to six bolometers with Ti/Au/Ti/Au transition edge sensors (three bands × two polarizations). In total, the SPT-3G receiver is composed of 16,000 detectors, which are read out using a 68 × frequency-domain multiplexing scheme. In this paper, we present the process employed in fabricating the detector arrays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Special Nuclear Material Characterization Using Digital 3-D Position Sensitive CdZnTe Detectors and High Purity Germanium Spectrometers

Special nuclear material (SNM) monitoring often requires high resolution gamma-ray spectroscopy for material characterization. Portable systems and rapid deployment are also highly valued for some applications. Deployable gamma-ray imaging spectrometers using pixelated CdZnTe semiconductor detectors have become commercially available within the past three years to meet these requirements. CdZnTe systems have demonstrated room-temperature energy resolutions below 0.5% FWHM at 662 keV using single pixel events and below 0.7% FWHM at 662 keV using all events. The systems are able to go from storage to measurement in less than two minutes. Special nuclear materials were measured at the Y-12 National Security Complex and at the Device Assembly Facility at the Nevada National Security Site. The use of a CdZnTe system to measure uranium enrichment was demonstrated and uranium spectral features were compared to a commercially available high purity germanium (HPGe) spectrometer. The use of passive gamma ray spectroscopy techniques to estimate plutonium grade using CdZnTe detectors was demonstrated for the first time.

CdZnTe detectors, gamma-ray imaging, gamma-ray spe↗

Muon Borehole Detector Design for Use in 4-D Density Overburden Monitoring

The increase of atmospheric CO2 concentrations has initiated research into carbon sequestration methods. One possibility is to store CO2 in subsurface porous reservoirs. The monitoring of the injected CO2 plume is vital because escaping CO2 poses health and environmental risks. Typically, seismic reflection methods are used to determine the change in density due to the replacement of brine by CO2 in the reservoir, but this is expensive and not continuous. A potential alternative is to use cosmic muon tomography to measure density changes in the reservoir as a function of time. This paper describes the development of a muon detector that will be capable of being deployed in boreholes. The detector has the required dimensions, an angular resolution of approximately 2 degrees, and is robust. The design is based on alternating layers of scintillating rods, which can provide 4-D tomographic data to detect small changes in density at depths up to approximately 2 km. Geant4, a Monte Carlo simulation code, is being used to develop models to guide the design of the physical configuration. Preliminary testing and measurements have been performed to validate the simulation predictions and optimize the performance of the system. The simulation and preliminary experimental results are presented here.

Borehole Detector, CO¬2 Sequestration, Geant4, Muo↗

Assessment of SNPP VIIRS RSB detector-to-detector differences using deep convective clouds and deserts

An accurate on-orbit characterization of the Visible Infrared Imaging Radiometer Suite (VIIRS) onboard the Suomi National Polar-orbiting Partnership satellite is essential to satisfy the requirements from NOAA, NASA, and the general research community for high-quality operational and research products. NASA’s Land Science Investigator-led Processing System (LSIPS) sensor data records (SDRs) are utilized to assess the stability of the calibrated top of atmosphere reflectance over the deep convective clouds (DCCs) and over the Libya-4desert site. The results from DCCs and desert show detector-to-detector (D2D) reflectance differences in the VIIRS reflective solar bands, 10 moderate-resolution bands (M-bands, M1to M5, M7 to M11), and three imagery resolution bands (I-bands, I1-I3). More importantly, the D2D differences exhibit an increase in magnitude over time for bands M1 to M5 and I1to I2, which induces noticeable striping and higher uncertainties in the downstream data products. The largest D2D difference is observed in bands M1 and M2, with magnitudes greater than1.8% in trends among the 16 detectors and standard deviations less than 0.12% over time. TheD2D stability assessment results over DCCs are consistent with those observed over the Libya-4desert site. To improve the quality of the calibrated SDR reflectance data, NASA’s VIIRS characterization support team has improved the calibration algorithm to incorporate corrections based on these DCC measurements to mitigate the striping (detector differences) observed in the current version of the SDR. These improvements are planned to be included in the next mission reprocessing of the LSIPS land products.

SNPP VIIRS↗

Cesium lead bromide semiconductor radiation detectors: crystal growth, detector performance and polarization

Cesium lead bromide (CsPbBr 3 ) is an upcoming semiconductor radiation detector that has the potential to match the detection properties of cadmium zinc telluride (CZT) and thallium bromide (TlBr). In this paper, we report on CsPbBr 3 gamma detectors with an uncorrected energy resolution of 2% at 662 keV with photopeak-to-Compton ratios as high as 14.3 and hole mobility-lifetime products (μτ h ) as high as 1.7 × 10 –2 cm 2 V –1 . Furthermore, we demonstrate that the processes employed for material purification and crystal growth of high-performing devices are scalable, and large (up to 65 mm in diameter) ultrahigh purity CsPbBr 3 crystals have been successfully grown. Furthermore by using optimized growth conditions and detector fabrication processes, we were able to mitigate the polarization problem where it was revealed that the polarization process is highly dependent on the crystal quality and the electric field direction with respect to the orientation of the crystal.

30 DIRECT ENERGY CONVERSION↗

Cryogenic gamma detectors enable direct detection of 236 U and minor actinides for non-destructive assay [Cryogenic gamma detectors enable direct detection of minor actinides for non-destructive assay]

Here, we demonstrate the utility of a superconducting transition edge sensor (TES) γ-ray detector with high energy resolution and low Compton background for non-destructive assay (NDA) of a uranium sample from reprocessed nuclear fuel. We show that TES γ-detectors can separate low energy actinide γ-emissions from the background and nearby lines, even from minor isotopes whose signals are often obscured in NDA with conventional Ge detectors. Superconducting γ detectors may therefore bridge the gap between high-accuracy destructive assay (DA) and easier to-use NDA.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cosmic-muon characterization and annual modulation measurement with Double Chooz detectors

A study on cosmic muons has been performed for the two identical near and far neutrino detectors of the Double Chooz experiment, placed at ∼120 and ∼300 m.w.e. underground respectively, including the corresponding simulations using the MUSIC simulation package. This characterization has allowed us to measure the muon flux reaching both detectors to be (3.64 ± 0.04) × 10{sup −4} cm{sup −2}s{sup −1} for the near detector and (7.00 ± 0.05) × 10{sup −5} cm{sup −2}s{sup −1} for the far one. The seasonal modulation of the signal has also been studied observing a positive correlation with the atmospheric temperature, leading to an effective temperature coefficient of α {sub T} = 0.212 ± 0.024 and 0.355 ± 0.019 for the near and far detectors respectively. These measurements, in good agreement with expectations based on theoretical models, represent one of the first measurements of this coefficient in shallow depth installations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pixelated transmission-mode diamond X-ray detector

Fabrication and testing of a prototype transmission-mode pixelated diamond X-ray detector (pitch size 60–100 µm), designed to simultaneously measure the flux, position and morphology of an X-ray beam in real time, are described. The pixel density is achieved by lithographically patterning vertical stripes on the front and horizontal stripes on the back of an electronic-grade chemical vapor deposition single-crystal diamond. The bias is rotated through the back horizontal stripes and the current is read out on the front vertical stripes at a rate of ~1 kHz, which leads to an image sampling rate of ~30 Hz. This novel signal readout scheme was tested at beamline X28C at the National Synchrotron Light Source (white beam, 5–15 keV) and at beamline G3 at the Cornell High Energy Synchrotron Source (monochromatic beam, 11.3 keV) with incident beam flux ranges from 1.8 × 10 -2 to 90 W mm -2 . Test results show that the novel detector provides precise beam position (positional noise within 1%) and morphology information (error within 2%), with an additional software-controlled single channel mode providing accurate flux measurement (fluctuation within 1%).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fielding the LANL Gas Cherenkov Detector (GCD-3) at the National Ignition Facility: The engineering challenges of designing, analyzing, fabricating, testing, and commissioning the next-generation GCD detector and WellDIM3.9m insertion manipulator for use at NIF

We report that fielding the LANL third-generation Gas Cherenkov Detector (GCD-3) at the National Ignition Facility (NIF) revealed an array of complex engineering challenges. Fielding the GCD-3 Detector in a 3.9 meter re-entrant Well on the NIF Target Chamber required the development of a specialized detector deployment system named the WellDIM3.9m Diagnostic Manipulator (WellDIM). The most stringent design requirement entailed a no-load/no-contact condition with the Well, which dictated that all seismic loads be transferred to the Target Chamber port flange. The WellDIM transports the GCD-3 into the Well at a distance of 3.9m from Target Chamber Center. Finally, the GCD-3 Detector, outfitted with additional shielding to mitigate higher NIF backgrounds, will serve as a prototype for the future, heavily shielded “Super-GCD”.

42 ENGINEERING↗

Heavy Flavor Physics at the EIC with the ECCE detector

The proposed Electron-Ion Collider (EIC) will operate high-energy high-luminosity electron+proton and electron+nucleus collisions to solve several unresolved fundamental questions. Due to their large masses (mc,b > ΛQCD), heavy quarks and their hadron products are ideal probes to study the nucleon/nuclear parton distribution functions in the high Bjorken-x (xBJ > 0.1) region and explore the hadronization process within the unconstrained kinematic region. Recently, the Electron-Ion Collider Comprehensive Chromodynamics Experiment (ECCE) consortium detector conceptual design has been selected as the reference design for the EIC project detector. The precise momentum and spatial resolutions provided by the ECCE tracking detector enable a series of open heavy flavor and quarkonia measurements. The physics projections of these proposed heavy flavor measurements in simulation studies using the ECCE detector design will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Complementary Barrier Infrared Detector (CBIRD) with Double Tunnel Junction Contact and Quantum Dot Barrier Infrared Detector (QD-BIRD)

The InAs/GaSb type-II superlattice based complementary barrier infrared detector (CBIRD) has already demonstrated very good performance in long-wavelength infrared (LWIR) detection. In this work, we describe results on a modified CBIRD device that incorporates a double tunnel junction contact designed for robust device and focal plane array processing. The new device also exhibited reduced turn-on voltage. We also report results on the quantum dot barrier infrared detector (QD-BIRD). By incorporating self-assembled InSb quantum dots into the InAsSb absorber of the standard nBn detector structure, the QD-BIRD extend the detector cutoff wavelength from approximately 4.2 micrometers to 6 micrometers, allowing the coverage of the mid-wavelength infrared (MWIR) transmission window. The device has been observed to show infrared response at 225 K.

antimonide↗

A neural network clustering algorithm for the ATLAS silicon pixel detector

A novel technique to identify and split clusters created by multiple charged particles in the ATLAS pixel detector using a set of artificial neural networks is presented. Such merged clusters are a common feature of tracks originating from highly energetic objects, such as jets. Neural networks are trained using Monte Carlo samples produced with a detailed detector simulation. This technique replaces the former clustering approach based on a connected component analysis and charge interpolation. The performance of the neural network splitting technique is quantified using data from proton-proton collisions at the LHC collected by the ATLAS detector in 2011 and from Monte Carlo simulations. This technique reduces the number of clusters shared between tracks in highly energetic jets by up to a factor of three. It also provides more precise position and error estimates of the clusters in both the transverse and longitudinal impact parameter resolution.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗