Rolling-element fatigue and lubrication with fluorinated polyethers at cryogenic temperatures
Rolling-element fatigue and lubrication with fluorinated polyethers at cryogenic temperatures
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Rolling-element fatigue and lubrication with fluorinated polyethers at cryogenic temperatures
Cryogenic temperature effect on short life torsional fatigue properties of Ni-Cr-Mo steel, discussing cyclic strain range effects
Metal lined glass filament-wound pressure vessel performance at cryogenic temperatures, discussing fibers, resins and liners
Radiometric measurement of total normal emittances of real surfaces at cryogenic temperatures
Ambient and cryogenic temperature mechanical properties and the ambient temperature stress corrosion properties of annealed, straightened, and centerless ground Nitronic 60 stainless steel alloy bar material are presented. The mechanical properties of longitudinal specimens were evaluated at test temperatures from ambient to liquid hydrogen. The tensile test data indicated increasing strength with decreasing temperature to -196 C. Below liquid nitrogen temperature the smooth tensile and notched tensile strengths decreased slightly while the elongation and reduction of area decreased drastically. The Charpy V-notched impact energy decreased steadily with decreasing test temperature. Stress corrosion tests were performed on longitudinal tensile specimens and transverse C-ring specimens exposed to: alternate immersion in a 3.5% NaCl bath; humidity cabinet; and a 5% salt spray atmosphere. The longitudinal tensile specimens experienced no corrosive attack. Approximately 3/4 of the transverse C-rings exposed to alternate immersion and to salt spray experienced a pitting attack on the top and bottom ends. Additional stress corrosion tests were performed on transverse tensile specimens. No failures occurred in the 90% stressed specimens exposed for 90 days in the alternate immersion and salt spray environments
The mechanical properties are presented of solution treated and age hardened A-286 corrosion resistant steel bar stock. Material solution treated at 899 C or 982 C, each followed by an age hardening treatment of 718 C, was evaluated. Test specimens manufactured from 1.50 inch (3.81 cm) diameter bar stock were tested at temperatures from +649 C to -253 C. The test data indicated excellent tensile, yield, elongation and reduction-in-area properties at all testing temperatures for both solution treated and aged materials. Cryogenic temperature notched tensile, impact, and shear tests indicated excellent notch strength, ductility, and shear values. There was very little difference in the mechanical properties of the two solution treated and aged materials. The only exception was that the 962 C solution treated and aged material had superior stress rupture properties at 649 C.
The objective of this study is to evaluate the low temperature behavior of polymer composites down to the cryogenic temperature range. This would be accomplished by study of its behavior in several ways. First we would study the microfracture growth by observing the acoustic emission as the temperature is lowered. We would also note any damage growth by ultrasonic velocity testing applying the pulse echo method. Effects of such low temperature would then be studied by examining the shear properties by the short beam shear test, and also the fracture toughness properties over a wide range of strain rate and temperature. At present these studies are continuing. The limited data obtained from these studies are reported in this report.
Continuity gauge measurement of crack growth on flat and curved surfaces at cryogenic temperatures
An investigation was conducted at the National Transonic Facility (NTF) to document the change in sting-balance deflections from ambient to cryogenic temperatures. Space limitations in some NTF models do not allow the use of on-board angle of attack instrumentation. In order to obtain angle of attack data, pre-determined sting-balance bending data must be combined with arc sector angle measurements. Presently, obtaining pretest sting-balance data requires several cryogenic cycles and cold loadings over a period of several days. A method of reducing the calibration time required is to obtain only ambient temperature sting-balance bending data and correct for changes in material properties at cryogenic temperatures. To validate this method, two typical NTF sting-balance combinations were tested. The test results show excellent agreement with the predicted values and the repeatability of the data was 0.01 degree.
Cryostat with support structure for test specimen allows flexure fatigue testing of honeycomb composite sandwich structures at cryogenic temperatures. The cryostat consists of a cryogen container enclosing two pairs of yokes which support two rotating end clamps.
Nuclear radiation effects on aluminum, titanium, vanadium, and tin alloys at cryogenic temperature
Graphite fiber resin composites physical and mechanical properties at ambient and cryogenic temperatures, discussing unidirectional ring and bar specimens and filament wound pressure vessels
A mechanically resonant synchronous chopper mechanism is described for use at cryogenic temperatures. The mechanism is a critical optical component of the Diffuse Infrared Background Experiment (DIRBE) and has been operating on orbit without incident since Nov. 1989. The requirements, electromechanical design, and testing of the mechanism are described. A description of the problems encountered and solutions implemented during the development of the mechanism is provided. Finally, a modified chopper design, which incorporated lessons learned and that has several advantages over the flight chopper design, is offered.
The gain and noise figure performance of a GaAs amplifier at cryogenic temperatures has been studied. Results obtained indicate that a lower noise figure and a higher gain are induced by decreasing the temperature, while no significant change in the input 1-dB compression point is observed. Repeated temperature cycling had no adverse effect on the amplifier performance.
Structural reinforced plastic materials at cryogenic temperatures
Structural reinforced plastic composite materials for cryogenic temperature application evaluated noting tensile, compression, shear, flexural and bearing properties
Platinum resistance thermometers tested and evaluated in cryogenic temperature measurement
Texture strengthening and fracture toughness of titanium alloy sheet at room and cryogenic temperatures