Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cryogen”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Cryogenic temperatures promote the pressure-induced polymorphic transition in CoCrFeMnNi high entropy alloy

Pressure-induced polymorphism has recently been demonstrated in several high entropy alloys. This offers a new window into the much-debated issue of phase selection and stability in these systems. Here, we examine the effect of cryogenic temperatures on the pressure-induced transition from face centered cubic to hexagonal close-packed structures of the prototype CoCrFeMnNi (Cantor) alloy. We observe a reduction in the critical pressure for the onset of the polymorphic transition as the temperature decreases, confirming the progressive stabilization of the hexagonal phase with decreasing temperature previously predicted by ab initio calculations accounting for magnetic interactions. We argue that in situ high-pressure experiments at cryogenic temperatures, which suppress time-dependent transformation triggered at higher temperatures, present a unique opportunity to significantly improve our understanding of these complex alloys.

alloys↗

Cryogenic single-molecule fluorescence annotations for electron tomography reveal in situ organization of key proteins in Caulobacter

Superresolution fluorescence microscopy and cryogenic electron tomography (CET) are powerful imaging methods for exploring the subcellular organization of biomolecules. Superresolution fluorescence microscopy based on covalent labeling highlights specific proteins and has sufficient sensitivity to observe single fluorescent molecules, but the reconstructions lack detailed cellular context. CET has molecular-scale resolution but lacks specific and nonperturbative intracellular labeling techniques. Here, we describe an imaging scheme that correlates cryogenic single-molecule fluorescence localizations with CET reconstructions. Our approach achieves single-molecule localizations with an average lateral precision of 9 nm, and a relative registration error between the set of localizations and CET reconstruction of ∼30 nm. We illustrate the workflow by annotating the positions of three proteins in the bacterium Caulobacter crescentus : McpA, PopZ, and SpmX. McpA, which forms a part of the chemoreceptor array, acts as a validation structure by being visible under both imaging modalities. In contrast, PopZ and SpmX cannot be directly identified in CET. While not directly discernable, PopZ fills a region at the cell poles that is devoid of electron-dense ribosomes. We annotate the position of PopZ with single-molecule localizations and confirm its position within the ribosome excluded region. We further use the locations of PopZ to provide context for localizations of SpmX, a low-copy integral membrane protein sequestered by PopZ as part of a signaling pathway that leads to an asymmetric cell division. Our correlative approach reveals that SpmX localizes along one side of the cell pole and its extent closely matches that of the PopZ region.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Giant elastocaloric effect at low temperatures in TmVO 4 and implications for cryogenic cooling

Adiabatic decompression of paraquadrupolar materials has significant potential as a cryogenic cooling technology. We focus on TmVO 4 , an archetypal material that undergoes a continuous phase transition to a ferroquadrupole-ordered state at 2.15 K. Above the phase transition, each Tm ion contributes an entropy of k B ln 2 due to the degeneracy of the crystal electric field groundstate. Owing to the large magnetoelastic coupling, which is a prerequisite for a material to undergo a phase transition via the cooperative Jahn–Teller effect, this level splitting, and hence the entropy, can be readily tuned by externally induced strain. Using a dynamic technique in which the strain is rapidly oscillated, we measure the adiabatic elastocaloric response of single-crystal TmVO 4 , and thus experimentally obtain the entropy landscape as a function of strain and temperature. The measurement confirms the suitability of this class of materials for cryogenic cooling applications and provides insight into the dynamic quadrupole strain susceptibility.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Issues in Formation of Cryogenic Pellets for Fusion Applications

Cryogenic pellets are used for injection into fusion plasmas to add fuel to build up density and replace the ions lost from fusion reactions and imperfect confinement in the plasma. These pellets are formed at cryogenic temperatures with pure hydrogenic isotopes or mixtures of the isotopes. Technology to make these pellets and inject them into plasmas has been under development for many years, and various methods using freezing or desublimation have been shown to produce high-quality solid pellets suitable for injection. The throughput needed and possible impurity content from the necessary recirculation of fusion exhaust gases are two of the key issues to overcome for fusion pellet fueling systems in long-pulse burning plasmas. Here, we describe the technical challenges associated with these issues and the capability of pellet formation extruders to overcome them.Cryogenic pellets of deuterium, neon, and argon are also used in fusion tokamak devices for disruption mitigation in the form of large pellets that can be injected on demand to quickly dissipate the plasma thermal energy through radiation and add significant density in order to prevent runaway electron formation. Here, the issue is not throughput as with the fueling pellets but rather is the time it takes to form pellets of the size needed and the ability to dislodge them immediately on demand when needed to mitigate a disruption. The method used to make these pellets by desublimation is described, and examples related to how pellet size and input gas parameters affect the formation time are provided.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of a compact, cryogen-free superconducting solenoid for the electron lens of the Fermilab Integrable Optics Test Accelerator (IOTA)

The proposed electron lens for Fermilab's Integrable Optics Test Accelerator (IOTA) will broaden its capabilities by enabling new research in nonlinear integrable optics, space-charge compensation, proton beam cooling, and more. The electron lens is based on a 5–10 keV, 1–2 A electron beam, shaped using a 0.7 m long, 0.8 T solenoidal magnetic field. A cryogen-free superconducting solenoid has been designed to provide this solenoidal field, taking into consideration the constraints on space, utilities, and infrastructure in the IOTA experimental hall. The solenoid is made of copper stabilized niobium-titanium conductor, conduction-cooled using 4 K closed-cycle cryocoolers. This paper describes the overall design of the solenoid encompassing its mechanical construction, current leads optimization, cryogenic thermal modeling that provides estimates of cooldown time and static/dynamic heat loads, and quench analysis.

43 PARTICLE ACCELERATORS↗

An energy-dependent electro-thermal response model of CUORE cryogenic calorimeter

The Cryogenic Underground Observatory for Rare Events (CUORE) is the most sensitive experiment searching for neutrinoless double-beta decay (0νββ) in 130 Te. CUORE uses a cryogenic array of 988 TeO 2 calorimeters operated at ~10 mK with a total mass of 741 kg. To further increase the sensitivity, the detector response must be well understood. Here, we present a non-linear thermal model for the CUORE experiment on a detector-by-detector basis. We have examined both equilibrium and dynamic electro-thermal models of detectors by numerically fitting non-linear differential equations to the detector data of a subset of CUORE channels which are well characterized and representative of all channels. Further, we demonstrate that the hot-electron effect and electric-field dependence of resistance in NTD-Ge thermistors alone are inadequate to describe our detectors' energy-dependent pulse shapes. We introduce an empirical second-order correction factor in the exponential temperature dependence of the thermistor, which produces excellent agreement with energy-dependent pulse shape data up to 6 MeV. We also present a noise analysis using the fitted thermal parameters and show that the intrinsic thermal noise is negligible compared to the observed noise for our detectors.

47 OTHER INSTRUMENTATION↗

Cryogenics and purification systems of the ICARUS T600 detector installation at Fermilab

This paper describes the cryogenic and purification systems of the ICARUS T600 detector in its present implementation at the Fermi National Laboratory, Illinois, U.S.A. The ICARUS T600 detector is made of four large Time Projection Chambers, installed in two separate containers of about 275 m 3 each. The detector uses liquid argon both as target and as active medium. For the correct operation of the detector, the liquid argon must be kept in very stable thermal conditions and the contamination of electronegative impurities must be consistently kept at the level of small fractions of parts per billion. The detector was previously operated in Italy, at the INFN Gran Sasso Underground Laboratory (LNGS), in a three-year run on the CERN to LNGS Long Baseline Neutrino Beam. For its operation on the Booster and NuMI neutrino beams at Fermilab, for the search of sterile neutrinos and measurements of neutrino-argon cross sections, the detector was moved from Gran Sasso to CERN for the upgrades required for operation at shallow depth with high intensity neutrino beams. The liquid argon containers, the thermal insulation and all the cryogenic equipment have been completely re-designed and rebuilt, following the schemes of the previous installation in Gran Sasso. The detector and all the equipment have been transported to Fermilab, where they have been installed, tested and recently put into operation. The work described in this paper has been conducted as a joint responsibility of CERN and Fermilab with the supervision provided by the ICARUS Collaboration. Design, installation, testing, commissioning and operation are the result of a common effort of CERN, Fermilab and INFN groups.

Cryogenic detectors↗

Material Effects on Electron-Capture Decay in Cryogenic Sensors

Several current searches for physics beyond the standard model are based on measuring the electron-capture (EC) decay of radionuclides implanted into cryogenic high-resolution sensors. The sensitivity of these experiments has already reached the level where systematic effects related to atomic state energy changes from the host material are a limiting factor. One example is a neutrino mass study based on the nuclear EC decay of 7 Be to 7 Li inside cryogenic Ta-based sensors. Here, to understand the material effects at the required level, we use density-functional theory to model the electronic structure of lithium atoms in different atomic environments of the polycrystalline Ta absorber film. The calculations reveal that the Li 1s binding energies can vary by more than 2 eV due to insertion at different lattice sites, at grain boundaries, in disordered Ta, and in the vicinity of various impurities. However, the total range of Li 1s shifts does not exceed 4 eV, even for extreme amorphous disorder. Furthermore, when investigating the effects on the Li 2s levels, we find broadening of more than 5 eV due to hybridization with the Ta band structure. Material effects are shown to contribute significantly to peak broadening in Ta-based sensors that are used to search for physics beyond the standard model in the EC decay of 7 Be, but they do not explain the full extent of observed broadening. Understanding these in-medium effects will be required for current- and future-generation experiments that observe low-energy radiation from the EC decay of implanted isotopes to evaluate potential limitations on the measurement sensitivity.

36 MATERIALS SCIENCE↗

Lessons from commissioning and operations of the ICARUS cryogenic system at Fermilab

Results and lessons from three years of commissioning and operations of the cryogenic and purificationsystems of the ICARUS neutrino detector installed at the Fermilab are described. The detector uses liquid argon stored in two separate containers of about 275 m 3 each. The liquid argon must be kept in very stable thermal conditions, and the contamination of electronegative impurities must be consistently kept at small fractions of parts per billion. Since its fill in early 2020, the detector has been commissioned and then operated in neutrino beams at Fermilab for the search of sterile neutrinos and measurements of neutrino-argon cross sections. The results of operating the cryogenic and purification systems and lessons learned, including challenges in reaching the design electron lifetime in argon bath, operating and servicing liquid nitrogen and argon circulation pumps, argon condensers and purifiers, are described. Plans for future operations and list of recommendations are presented.

43 PARTICLE ACCELERATORS↗

Energy-Storing Cryogenic Carbon Capture™ for Utility and Industrial-scale Processes (Final Report)

This project leverages work completed under funding from previous U.S. Department of Energy (DOE) projects and other sources of funding around the Cryogenic Carbon Capture Process™ (CCC). The purpose of this project is to further develop a perturbation of the CCC process that stores energy called the Cryogenic Carbon Capture™ Energy Storing (CCC-ES) process. The successful completion of the tasks in this project has prepared the CCC-ES process for scaling and developed initial plans and a feasibility analysis for an engineering-scale or small-commercial scale system that can store at least 10 MWh of energy. The specific areas of work in this project are: (1) Develop a conceptual, site-specific integrated process flow diagram: Sustainable Energy Solutions (SES) developed a conceptual, site-specific plan including a process flow diagram for integrating CCC-ES at a specific location. The proposed system was based on a typical engineering-scale CCC system designed to capture 30-50 metric tonnes of CO 2 per day (TPD), with modifications and additional changes and equipment put in place to add the energy storage element to the system. The 30-50 TPD scale corresponds to the required 10 MWh of stored energy. This task includes updating simulation software for transient analysis. SES also coordinated with the Jim Bridger Power Plant in Point of Rocks, Wyoming to get site-specific data. Using these data, SES completed site-specific preliminary process flow diagrams, estimated capital and operating costs for the CCC-ES system, and used the upgraded software package to estimate the primary figures of merit. (2) Complete a technoeconomic analysis (TEA): SES completed a full-scale TEA of the CCC-ES system to meet specific success criteria. This TEA used process information from the host site selected above. (3) Technology and data gap assessment for the CCC-ES process: As part of the technology gap assessment, SES performed an assessment of the best alternative energy storage solutions including figures of merit and operational strengths and weaknesses. SES then compared the proposed system with a discussion of how it addresses the weaknesses of alternative systems, showing for example a cost of stored energy at less than $50/MWh and with a roundtrip efficiency of greater than 95%. This assessment includes technical and other risk analyses and technology gaps with research and development needs to commercialize the process by 2030. Finally, work includes a commercialization roadmap/development pathway outlining the major milestones to move to a commercially operating CCC-ES system. (4) Phase II pre-FEED project plan: SES completed a project plan for the Phase II pre-FEED analysis using the same host site as in the Phase I conceptual study.

03 NATURAL GAS↗

A Portable Miniature Cryogenic Environment for In Situ Neutron Diffraction

Neutron diffraction instruments offer a platform for materials science and engineering studies at extended temperature ranges far from ambient. As one of the widely used neutron sample environment types, cryogenic furnaces are usually bulky and complex, and they may need hours of beamtime overhead for installation, configuration, cooling, and sample change, etc. To reduce the overhead time and expedite experiments at the state-of-the-art high-flux neutron source, we developed a low-cost, miniature, and easy-to-use cryogenic environment (77–473 K) for in situ neutron diffraction. A travel-size mug serves for the environment where the samples sit inside. Immediate cooling and an isothermal dwell at 77 K are realized on the sample by direct contact with liquid N 2 in the mug. The designed Al inserts serve as the holder of samples and heating elements, alleviate the thermal gradient, and clear neutron pathways. Both a single-sample continuous measurement and multi-sample high-throughput measurements are demonstrated in this environment. High-quality and refinable in situ neutron diffraction patterns are acquired on model materials. The results quantify the orthorhombic-to-cubic phase transformation process in LiMn 2 O 4 and differentiate the anisotropic lattice thermal expansions and bond length evolutions between rhombohedral perovskite oxides with composition variation.

47 OTHER INSTRUMENTATION↗

Numerical Simulations of Cryogenic Hydrogen Cooling in Vortex Tubes with Smooth Transitions

Improving efficiency of hydrogen cooling in cryogenic conditions is important for the wider applications of hydrogen energy systems. The approach investigated in this study is based on a Ranque-Hilsch vortex tube (RHVT) that generates temperature separation in a working fluid. The simplicity of RHVT is also a valuable characteristic for cryogenic systems. In the present work, novel shapes of RHVT are computationally investigated with the goal to raise efficiency of the cooling process. Specifically, a smooth transition is arranged between a vortex chamber, where compressed gas is injected, and the main tube with two exit ports at the tube ends. Flow simulations have been carried out using STAR-CCM+ software with the real-gas Redlich-Kwong model for hydrogen at temperatures near 70 K. It is determined that a vortex tube with a smooth transition of moderate size manifests about 7% improvement of the cooling efficiency when compared vortex tubes that use traditional vortex chambers with stepped transitions and a no-chamber setup with direct gas injection.

08 HYDROGEN↗

Colossal Cryogenic Electro‐Optic Response Through Metastability in Strained BaTiO 3 Thin Films

The search for thin film electro-optic materials that can retain superior performance under cryogenic conditions has become critical for quantum computing. Barium titanate thin films show large linear electro-optic coefficients in the tetragonal phase at room temperature, which is severely degraded down to ≈200 pm V −1 in the rhombohedral phase at cryogenic temperatures. There is immense interest in manipulating these phase transformations and retaining superior electro-optic properties down to liquid helium temperature. Utilizing the thermodynamic theory of optical properties, a large low-temperature electro-optic response is designed by engineering the energetic competition between different ferroelectric phases, leading to a low-symmetry monoclinic phase with a massive electro-optic response. The existence of this phase is demonstrated in a strain-tuned BaTiO 3 thin film that exhibits a linear electro-optic coefficient of 2516 ± 100 pm V −1 at 5 K, which is an order of magnitude higher than the best reported performance thus far. Importantly, the electro-optic coefficient increases by 100 × during cooling, unlike the conventional films, where it degrades. Further, at the lowest temperature, significant higher order electro-optic responses also emerge. These results represent a new framework for designing materials with property enhancements by stabilizing highly tunable metastable phases with strain.

barium titanate↗

Cryogenic Correlative Single‐Particle Photoluminescence Spectroscopy and Electron Tomography for Investigation of Nanomaterials

Abstract Cryogenic single‐particle photoluminescence (PL) spectroscopy has been used with great success to directly observe the heterogeneous photophysical states present in a population of luminescent particles. Cryogenic electron tomography provides complementary nanometer scale structural information to PL spectroscopy, but the two techniques have not been correlated due to technical challenges. Here, we present a method for correlating single‐particle information from these two powerful microscopy modalities. We simultaneously observe PL brightness, emission spectrum, and in‐plane excitation dipole orientation of CdSSe/ZnS quantum dots suspended in vitreous ice. Stable and fluctuating emitters were observed, as well as a surprising splitting of the PL spectrum into two bands with an average energy separation of 80 meV. In some cases, the onset of the splitting corresponded to changes in the in‐plane excitation dipole orientation. These dynamics were assigned to structures of individual quantum dots and the excitation dipoles were visualized in the context of structural features.

Dahlberg, Peter D.↗

Toward a standardization of cryostructure and cryogenic soil structure terminology for the field description of permafrost‐affected soils

This paper establishes standardized terminology and field documentation protocols for cryostructures and cryogenic soil structures in permafrost‐affected soils and provides brief guidance on descriptions of ground ice morphology and ice volume estimates. We consolidate permafrost terminology from Russian and North American literature, clarify long‐standing ambiguities, and provide explicit guidelines that align with US Department of Agriculture‐Natural Resources Conservation Service soil description standards. Our scheme makes critical distinctions between cryostructure, the distribution of ice within soil, and cryogenic soil structure, the morphological structure of soil resulting from ice formation. The scheme organizes cryostructures into three main categories: non‐segregated ice, visible segregated ice, and ice matrices. We introduce standardized codes and parameters for field descriptions of ice and soil that enable machine‐readable data collection compatible with existing soil information systems. This standardization will significantly enhance the integration of field observations into landscape‐scale assessments of permafrost stability, infrastructure vulnerability, and ecosystem response to permafrost thaw, addressing an urgent need for quantitative data to inform modeling and decision‐making in rapidly changing Arctic and subarctic environments.

Andersen, Megan L. [University of Minnesota, Saint↗

Simons Observatory Microwave SQUID Multiplexing Readout: Cryogenic RF Amplifier and Coaxial Chain Design

The Simons Observatory (SO) is an upcoming polarization-sensitive cosmic microwave background experiment on the Cerro Toco Plateau (Chile) with large overlap with other optical and infrared surveys (e.g., DESI, LSST, HSC). To enable the readout of O(10,000) detectors in each of the four telescopes of SO, we will employ the microwave SQUID multiplexing technology. With a targeted multiplexing factor of O(1000), microwave SQUID multiplexing has never been deployed on the scale needed for SO. Here we present the design of the cryogenic coaxial cable and RF component chain that connects room temperature readout electronics to superconducting resonators that are coupled to transition edge sensor bolometers operating at sub-Kelvin temperatures. We describe design considerations including cryogenic RF component selection, system linearity, noise, and thermal power dissipation.

47 OTHER INSTRUMENTATION↗

Two-Stage Cryogenic HEMT-Based Amplifier for Low-Temperature Detectors

To search for dark matter candidates with masses below $\mathcal{O}$ (MeV), the SPLENDOR (Search for Particles of Light dark mattEr with Narrow-gap semiconDuctORs) experiment is developing novel narrow-bandgap semiconductors with electronic bandgaps on the order of 1–100 meV. In order to detect the charge signal produced by scattering or absorption events, SPLENDOR has designed a two-stage cryogenic HEMT-based amplifier with an estimated charge resolution approaching the single-electron level. A low-capacitance (~ 1.6 pF) HEMT is used as a buffer stage at T = 10 mK to mitigate effects of stray capacitance at the input. The buffered signal is then amplified by a higher-capacitance (~ 200 pF) HEMT amplifier stage at T = 4 K. Importantly, the design of this amplifier makes it usable with any insulating material—allowing for rapid prototyping of a variety of novel detector materials. Here, we present the two-stage cryogenic amplifier design, preliminary voltage noise performance, and estimated charge resolution of 7.2 electrons.

47 OTHER INSTRUMENTATION↗

Monte Carlo calculations of the extraction of scintillation light from cryogenic $N$-type GaAs

We report the high scintillation luminosity of n-type GaAs at 10 °K is surprising because (1) with a refractive index of 3.5, escape is inhibited by total internal reflection and (2) narrow-beam experiments at 90 °K report infrared absorption coefficients of several per cm. This paper presents Monte Carlo calculations showing that the high luminosity at 10 °K can be explained if (1) the narrow-beam absorption is almost all optical scattering and (2) the absolute absorption coefficient is below 0.1 per cm. Sixteen surface reflector configurations are simulated for a range of internal scattering and absolute absorption coefficients, and these can guide the design of cryogenic scintillating GaAs targets for the direct detection of dark matter. The discussion section presents a possible infrared scattering mechanism based on the metallic nature of n-type GaAs. A supplement file describes (1) the Monte Carlo program steps in detail and (2) how narrow-beam and integrating sphere experiments can measure the cryogenic optical scattering and absolute absorption coefficients.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗