Optimizing Porous Transport Layer Porosity for Proton Exchange Membrane Water Electrolysis

An empirical model is presented that describes anode-side losses related to porous transport layer (PTL) morphology in proton exchange membrane water electrolysis (PEMWE). The model is based on an advanced voltage breakdown analysis that links various overpotentials to PTL morphology. Custom Ti PTLs, spanning uncommonly low porosities (22 - 31%), were fabricated and analyzed with X-ray CT to obtain pore and particle size distributions. Particle size distributions were consistent across samples with an average particle diameter of 12.0?..mu..m, whereas average pore diameters ranged from 6.0 to 7.0?..mu..m. The PTLs were tested in standard PEMWE cell assemblies with anode catalyst loadings of 0.1 mgIr cm-2 to obtain polarization curves, electrochemical impedance spectra, and augmented Tafel analysis. The PTL-dependent anode side losses were deconvoluted and assigned to excess utilization, concentration, ion transport resistance, and electrical contact resistance overpotentials. The data and model reveal an optimal 20 - 28% PTL porosity region where utilization and contact resistance overpotentials are minimized without triggering concentration and ion transport losses related to water deprivation. The optimal PTL porosity depends on the operating current density and is demonstrated at realistic PEMWE water flow rates to establish PTL design guidance for operation at scale.

08 HYDROGEN↗

Effect of Liquid Electrolyte Soaking on the Interfacial Resistance of Li 7 La 3 Zr 2 O 1 2 for All-Solid-State Lithium Batteries

In this work, the impact of liquid electrolyte soaking on the interfacial resistance between the garnet-structured Li 7 La 3 Zr 2 O 12 (LLZO) solid electrolyte and metallic lithium has been studied. Lithium carbonate (Li 2 CO 3 ) formed by inadvertent exposure of LLZO to ambient conditions is generally known to increase interfacial impedance and decrease lithium wettability. Soaking LLZO powders and pellets in the electrolyte containing lithium tetrafluoroborate (LiBF 4 ) shows a significantly reduced interfacial resistance and improved contact between lithium and LLZO. Raman spectroscopy, X-ray diffraction, and soft X-ray absorption spectroscopy reveal how Li 2 CO 3 is continuously removed with increasing soaking time. On-line mass spectrometry and free energy calculations show how LiBF 4 reacts with surface carbonate to form carbon dioxide. Using a very simple and scalable process that does not involve heat-treatment and expensive coating techniques, we show that the Li–LLZO interfacial resistance can be reduced by an order of magnitude.

25 ENERGY STORAGE↗

Increasing Ionic Conductivity of Poly(ethylene oxide) by Reaction with Metallic Li

Poly(ethylene oxide) (PEO) was the first lithium-ion conducting polymer developed 50 years ago and is still the most popular electrolyte matrix for solid-state lithium metal batteries. While many studies focus on increasing PEO ionic conductivity through doping with Li salts, little work has addressed using PEO and Li directly to generate Li + -conducting species in situ. Reaction between PEO and Li leads to ionic conductivity largely from Li + , in contrast to the case of added salts where the anion contribution dominates. Herein, electrochemical impedance spectroscopy shows the ionic conductivity of PEO thin films increases up to three orders of magnitude (from 10 –7 to 10 –4 S cm –1 ) when contacted with Li at elevated temperature. This is due to the reduction of ether bonds, which produces lithium alkoxides that are responsible for Li + transport. Density functional theory analysis confirms this mechanism as thermodynamically favorable. X-ray photoelectron spectroscopy also shows the presence of organolithium species and Li 2 O, which are responsible for propagating reactions with PEO and forming an electronically insulating layer at the PEO–Li interface that halts further reaction, respectively. The underlying mechanisms of Li–polymer electrolyte reactions is clarified and new pathways for in situ Li + doping of polymer electrolytes is presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Functionalization of Cathode–Electrolyte Interface with Ionic Liquids for High-Performance Quasi-Solid-State Lithium–Sulfur Batteries: A Low-Sulfur Loading Study

We introduce a quasi-solid-state electrolyte lithium-sulfur (Li–S) battery (QSSEB) based on a novel Li-argyrodite solid-state electrolyte (SSE), Super P–Sulfur cathode, and Li-anode. The cathode was prepared using a water-based carboxymethyl cellulose (CMC) solution and styrene butadiene rubber (SBR) as the binder while Li6PS5F0.5Cl0.5 SSE was synthesized using a solvent-based process, via the introduction of LiF into the argyrodite crystal structure, which enhances both the ionic conductivity and interface-stabilizing properties of the SSE. Ionic liquids (IL) were prepared using lithium bis(trifluoromethyl sulfonyl)imide (LiTFSI) as the salt, with pre-mixed pyrrolidinium bis(trifluoromethyl sulfonyl)imide (PYR) as solvent and 1,3-dioxolane (DOL) as diluent, and they were used to wet the SSE–electrode interfaces. The effect of IL dilution, the co-solvent amount, the LiTFSI concentration, the C rate at which the batteries are tested and the effect of the introduction of SSE in the cathode, were systematically studied and optimized to develop a QSSEB with higher capacity retention and cyclability. Interfacial reactions occurring at the cathode–SSE interface during cycling were also investigated using electrochemical impedance spectroscopy, cyclic voltammetry, and X-ray photoelectron spectroscopy supported by ab initio molecular dynamics simulations. This work offers a new insight into the intimate interfacial contacts between the SSE and carbon–sulfur cathodes, which are critical for improving the electrochemical performance of quasi-solid-state lithium–sulfur batteries.

25 ENERGY STORAGE↗

Results From the USML-2 Interface Configuration Experiment

Mathematical theory predicts that small changes in container shape or in contact angle can give rise to large shifts of liquid in a microgravity environment. For studying such shifts, container shapes are described that were flown on board the Space Shuttle USML-2 mission as part of the Glovebox Interface Configuration Experiment. These containers are in the form of a circular cylinder with two diametrically opposed "canonical proboscis" protrusions. The containers were designed with the goal of having two desirable properties -that sufficient liquid would participate in the shift to permit easy observation, and that the change would be abrupt enough to allow accurate determination of critical contact angle. The observed behavior for these vessels is depicted, along with behavior for a movable wedge vessel, which also formed part of the experiment. The experimental results support the validity of the concept of macroscopic contact angle, basic to the theory, and thereby its use in predicting fluid behavior under reduced gravity. The results indicate, as well, the role of hysteresis in impeding orientation to equilibrium.

Concus, Paul↗

Three-dimensional ballistocardiography and respiratory motion in sustained microgravity

BACKGROUND: We measured the three-dimensional ballistocardiogram (BCG) in a free-floating subject in sustained microgravity during spaceflight to test the usefulness of such measurements for future non-invasive monitoring of cardiac function, and to examine the effects of respiratory movement on the BCG in three axes. METHODS: Acceleration was measured using a three-axis accelerometer fastened to the lumbar region of the subject while simultaneous recordings of ECG, and respiratory motion via impedance plethysmography were also made. Data were recorded during a 146-s period of inactivity on the part of the subject during which time there was no contact with the spacecraft. RESULTS: Total body motion due to respiratory activity was consistent with that calculated from the known action of the diaphragm and conservation of momentum. The accelerations due to cardiac activity, ensemble averaged over the R-R interval, were greatest along the head-to-foot axis. Maximum amplitude of the HIJK complex of the BCG generated by ventricular ejection was greatest in the head to foot axis (approximately 70 x 10(-3) m x s(-2)), but there were also substantial accelerations along the dorsoventral axis of up to 43 10(-3) m x s(-2), that are not measured interrestrial two-dimensional studies. The amplitude of the BCG was strongly affected by lung volume, with accelerations being reduced 50 to 70% between end-inspiration and end-expiration. CONCLUSIONS: These data suggest a greatly reduced transmission of the cardiac motion to the body at end-expiration (FRC) than at higher lung volumes. The BCG might be further developed as a non-invasive means of monitoring parameters such as stroke volume in microgravity.

Flight Experiment↗

Copper iodide nanoparticles as a hole transport layer to CdTe photovoltaics: 5.5 % efficient back-illuminated bifacial CdTe solar cells

We report the role of copper iodide (CuI) nanoparticles (NPs) as a hole transport layer (HTL) in cadmium sulfide/cadmium telluride (CdS/CdTe) photovoltaics. These CuI NPs were prepared using solution processing at room temperature and used to fabricate monofacial and bifacial CdTe solar cells with different back contacts. Using CuI/Au as the back contact, the device efficiency reached to 14.8% with outstanding fill factor (FF) of 79.2%. Replacing the gold (Au) electrode with sputtered transparent indium tin oxide (ITO), a CuI/ITO back contact yielded photoconversion efficiencies (PCEs) of 11.6% and 5.5% under front and back illumination respectively. Bifacial devices (CdTe/ITO) without the CuI NP HTL have an efficiency of 7.0% and 1.0% for front and back illumination, respectively. For CuI/ITO, a current collection of 12.0 mAcm -2 was observed upon back illumination which significantly improved over an ITO-only back contact (5.0 mAcm -2 ). The PCE obtained from back illumination was enhanced when using CuI NPs as the HTL due to the reduced back barrier height, and improved back interface as determined by temperature dependent current vs. voltage characteristics and impedance spectroscopy analysis. The improvement in device performance of the bifacial configuration is a significant step forward toward realizing thin film photovoltaic modules which harvest energy incident on the rear of the module.

36 MATERIALS SCIENCE↗

Autocrine and paracrine interferon signalling as ‘ring vaccination’ and ‘contact tracing’ strategies to suppress virus infection in a host

The innate immune response, particularly the interferon response, represents a first line of defence against viral infections. The interferon molecules produced from infected cells act through autocrine and paracrine signalling to turn host cells into an antiviral state. Although the molecular mechanisms of IFN signalling have been well characterized, how the interferon response collectively contribute to the regulation of host cells to stop or suppress viral infection during early infection remain unclear. Here, we use mathematical models to delineate the roles of the autocrine and the paracrine signalling, and show that their impacts on viral spread are dependent on how infection proceeds. In particular, we found that when infection is well-mixed, the paracrine signalling is not as effective; by contrast, when infection spreads in a spatial manner, a likely scenario during initial infection in tissue, the paracrine signalling can impede the spread of infection by decreasing the number of susceptible cells close to the site of infection. Furthermore, we argue that the interferon response can be seen as a parallel to population-level epidemic prevention strategies such as ‘contact tracing’ or ‘ring vaccination’. Thus, our results here may have implications for the outbreak control at the population scale more broadly.

59 BASIC BIOLOGICAL SCIENCES↗

Fabrication of a Cryogenic Terahertz Emitter for Bolometer Focal Plane Calibrations

A fabrication process is reported for prototype emitters of THz radiation, which operate cryogenically, and should provide a fast, stable blackbody source suitable for characterization of THz devices. The fabrication has been demonstrated and, at the time of this reporting, testing was underway. The emitter is similar to a monolithic silicon bolometer in design, using both a low-noise thermometer and a heater element on a thermally isolated stage. An impedance-matched, high-emissivity coat ing is also integrated to tune the blackbody properties. This emitter is designed to emit a precise amount of power as a blackbody spectrum centered on terahertz frequencies. The emission is a function of the blackbody temperature. An integrated resistive heater and thermometer system can control the temperature of the blackbody with greater precision than previous incarnations of calibration sources that relied on blackbody emission. The emitter is fabricated using a silicon- on-insulator substrate wafer. The buried oxide is chosen to be less than 1 micron thick, and the silicon device thickness is 1-2 microns. Layers of phosphorus compensated with boron are implanted into and diffused throughout the full thickness of the silicon device layer to create the thermometer and heater components. Degenerately doped wiring is implanted to connect the devices to wire-bondable contact pads at the edge of the emitter chip. Then the device is micromachined to remove the thick-handle silicon behind the thermometer and heater components, and to thermally isolate it on a silicon membrane. An impedance- matched emissive coating (ion assisted evaporated Bi) is applied to the back of the membrane to enable high-efficiency emission of the blackbody spectrum.

Chervenak, James↗

Development of lithium ion conducting interface between lithium metal and a lithium ion conducting ceramic using block polymers

The lithium-air (Li-air) technology developed by EDF uses an air electrode which works with an aqueous electrolyte, which prevent the use of unprotected lithium metal electrode. A Li+ ionic conductor glass ceramic is used to separate the aqueous electrolyte compartment from the negative lithium electrode. However, this glass-ceramic is not stable in contact with lithium, it is thus necessary to add a protective buffer layer. In another hand, this protection should ideally resist to lithium dendritic growth. It is in this context that this research project which has as goal the development of a protective buffer layer based on block copolymer electrolytes (BCE) between the lithium metal and the lithium ionic conductor ceramic, for lithium-air battery. In a first part, the BCE is studied in lithium-lithium symmetric cells, in order to determine their electrochemical properties such as ionic conductivity, steady state transference number, and finally their resistance to dendritic growth during cycling. Several characterization techniques were employed and especially hard X-ray micro-tomography to analyze the lithium morphology before and after cycling. For single-ion BCE, we expect to suppress dendritic growth, however, we report here for the first time, the visualization of a homogeneous growth of lithium but the formation of dense lithium objects. In another part, the composite BCE-ceramic is studied by electrochemical impedance spectroscopy (EIS). The cycling of lithium-composite-lithium symmetric cells and the analysis of the EIS measurement after each cycle permit to determine if the dendrites have cross the protective layer and are in contact with the ceramic. Besides, the quantification of the polarization loss at the interface polymer-ceramic is evaluated by polarization experiments. This contribution is found to be small.

36 MATERIALS SCIENCE↗

Dependence of Linker Length and Composition on Ionic Conductivity and Lithium Deposition in Single-Ion Conducting Network Polymers

In this report, single-ion conducting electrolytes stand as promising alternatives to state-of-the-Art electrolytes in lithium batteries, although a single-ion conducting material with high Li + conductivity, stability in contact with lithium, and suitable mechanical properties has been slow to emerge. Here, we describe the synthesis of a series of single-ion conducting network polymers from the reaction of tetrakis(4-(chloromethyl)-2,3,5,6-Tetrafluorophenyl)borate with oligoethylene glycoxide linkers Li 2 O[(CH 2 CH 2 )O] n (n = 1, 2, 3, 9, and 22). Polymers with the longest linkers (n = 9 and 22; ANP-9 and ANP-10, respectively) form materials with conductivities of ~ 10 -6 S cm -1 at 100 °C. With the addition of 65 wt % propylene carbonate (PC), all the network polymers in the series exhibit high conductivities at ambient temperatures, with the n = 1 material (ANP-6) achieving a bulk ionic conductivity of 2.5 x 10 -4 S cm -1 at 25 °C. More conductive single-ion conducting gels could be prepared by using the less coordinating pentanediol dilithium salt as a linker (ANP-11; σ = 3.5 x 10 -4 S cm -1 at 25 °C), although this material exhibited a surprisingly high interfacial resistance in contact with a lithium electrode. In contrast, the gel formed with ANP-6 is notably stable in contact with metallic lithium electrodes, displays a lithium-ion transference number of unity, and boasts a wide electrochemical stability window of greater than 4.5 V. Temperature-dependent ac impedance analysis reveals that the ionic conductivity of this material-and likely the other gels in the series-matches closely to a Vogel-Tamman-Fulcher temperature model.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fabrication of high-performance gas-diffusion-electrode based membrane-electrode assemblies

This paper demonstrates the fabrication and processing steps required to produce high performance fuel cell membrane electrode assemblies (MEAs) based on spray-coated gas-diffusion electrodes (GDEs). It is demonstrated that coating the catalyst layer with a thin layer of ionomer and then hot pressing the GDEs to the membrane is required to achieve comparable catalyst activity and air performance to catalyst-coated-membrane MEAs. We show that there is a critical amount of ionomer required to achieve maximized performance. Using electron microscopy, we show that the combination of the ionomer overlayer and hot-pressing bonds the catalyst layer to the membrane, increasing the interfacial contact area and quality of this interface. We also find that the ionomer overlayer smooths the surface of the GDE and provides increased contact area between the GDE and the membrane. Additionally, we demonstrate that much less ionomer is required for high-performance than has been previously reported. Through model fitting of electrochemical impedance spectroscopy, we show that this improvement in the catalyst layer - membrane interface reduces the effective catalyst layer resistance, which reduces Ohmic losses and increases catalyst utilization.

33 ADVANCED PROPULSION SYSTEMS↗

Identification of Small-Molecule Inhibitors of Fibroblast Growth Factor 23 Signaling via In Silico Hot Spot Prediction and Molecular Docking to α-Klotho

Fibroblast growth factor 23 (FGF23) is a therapeutic target for treating hereditary and acquired hypophosphatemic disorders, such as X-linked hypophosphatemic (XLH) rickets and tumor-induced osteomalacia (TIO), respectively. FGF23-induced hypophosphatemia is mediated by signaling through a ternary complex formed by FGF23, the FGF receptor (FGFR), and α-Klotho. Currently, disorders of excess FGF23 are treated with an FGF23-blocking antibody, burosumab. Small-molecule drugs that disrupt protein/protein interactions necessary for the ternary complex formation offer an alternative to disrupting FGF23 signaling. In this study, the FGF23:α-Klotho interface was targeted to identify small-molecule protein/protein interaction inhibitors since it was computationally predicted to have a large fraction of hot spots and two druggable residues on α-Klotho. We further identified Tyr433 on the KL1 domain of α-Klotho as a promising hot spot and α-Klotho as an appropriate drug-binding target at this interface. Subsequently, we performed in silico docking of ~5.5 million compounds from the ZINC database to the interface region of α-Klotho from the ternary crystal structure. Following docking, 24 and 20 compounds were in the final list based on the lowest binding free energies to α-Klotho and the largest number of contacts with Tyr433, respectively. Herein, five compounds were assessed experimentally by their FGF23-mediated extracellular signal-regulated kinase (ERK) activities in vitro, and two of these reduced activities significantly. Both these compounds were predicted to have favorable binding affinities to α-Klotho but not have a large number of contacts with the hot spot Tyr433. ZINC12409120 was found experimentally to disrupt FGF23:α-Klotho interaction to reduce FGF23-mediated ERK activities by 70% and have a half maximal inhibitory concentration (IC50) of 5.0 ± 0.23 μM. Molecular dynamics (MD) simulations of the ZINC12409120:α-Klotho complex starting from in silico docking poses reveal that the ligand exhibits contacts with residues on the KL1 domain, the KL1–KL2 linker, and the KL2 domain of α-Klotho simultaneously, thereby possibly disrupting the regular function of α-Klotho and impeding FGF23:α-Klotho interaction. ZINC12409120 is a candidate for lead optimization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detecting the presence of microorganisms

The presence of microorganisms in a sample is determined by culturing microorganisms in a growth medium which is in contact with a measuring electrode and a reference electrode and detecting a change in potential between the electrodes caused by the presence of the microorganisms in the medium with a high impedance potentiometer.

Wilkins, Judd R.↗

Hand-Held Units for Short-Range Wireless Biotelemetry

Special-purpose hand-held radiotransceiver units have been proposed as means of short-range radio powering and interrogation of surgically implanted microelectromechanical sensors and actuators. These units are based partly on the same principles as those of the units described in "Printed Multi- Turn Loop Antennas for RF Biotelemetry" (LEW-17879-1), NASA Tech Briefs, Vol. 31, No. 6 (June 2007), page 48. Like the previously reported units, these units would make it unnecessary to have wire connections between the implanted devices and the external equipment used to activate and interrogate them. Like a unit of the previously reported type, a unit of the type now proposed would include a printed-circuit antenna on a dielectric substrate. The antenna circuitry would include integrated surface-mount inductors for impedance tuning. Circuits for processing the signals transmitted and received by the antenna would be included on the substrate. During operation, the unit would be positioned near (but not in electrical contact with) a human subject, in proximity to a microelectromechanical sensor or actuator that has been surgically implanted in the subject. It has been demonstrated that significant electromagnetic coupling with an implanted device could be established at a distance of as much as 4 in. (.10 cm). During operation in the interrogation mode, the antenna of the unit would receive a radio telemetry signal transmitted by the surgically implanted device. The antenna substrate would have dimensions of approximately 3.25 by 3.75 inches (approximately 8.3 by 9.5 cm). The substrate would have a thickness of the order of 30 mils (of the order of a somewhat less than a millimeter). The substrate would be made of low-radiofrequency- loss dielectric material that could be, for example, fused quartz, alumina, or any of a number of commercially available radio-frequency dielectric composite materials. The antenna conductors would typically be made of copper or a combination of chromium and gold. The choice of metal and the thickness of the metal layer(s) would depend on the choice of substrate material. For example, on a quartz or alumina substrate, one would typically use a layer of chromium 150 A thick and a layer of gold 2 m thick. The proposed units and the implanted devices that they would interrogate or activate would be inherently safe to use. They would operate at low radiated-power levels for short interrogation times (typically, milliseconds). Hence, there would be little local heating of tissues surrounding the implanted devices and little absorption of radio energy by such sensitive body parts as the eyes and the brain. Because the implanted devices would not depend on battery power and would be activated only during short interrogation intervals and would otherwise be in the goff h state most of the time, the useful lifetimes of the implanted devices would be greater than those of comparable battery-powered implanted devices. The compactness of the hand-held transceiver units would facilitate transport and storage and would facilitate self-diagnosis by patients able to handle the units while away from medical facilities.

Miranda, Felix A.↗

Electroanalytical Measurement of Interphase Formation at a Li Metal–Solid Electrolyte Interface

The interphase between Li metal and solid electrolytes dictates performance in Li metal batteries. For the solid electrolyte Lipon, in this study we electroanalytically measure a capacity loss of 1.03 ± 0.16 μAh/cm 2 when Lipon first contacts Li metal. Assuming this capacity is all lost to interphase formation, this corresponds to a maximum Li consumption of 5.0 ± 0.8 nm to form an interphase ~4.7 nm thick. From dynamic electrochemical impedance spectroscopy (dEIS) during Li plating, we determine that nonlinear chaotic spectra demark this interphase formation and that this occurs immediately upon initiation of Li plating. dEIS also reveals interfacial resistance during both plating and stripping that decreases as the amount of plated Li increases.

25 ENERGY STORAGE↗

Gel-Filled Holders For Ultrasonic Transducers

In new technique, ultrasonic transducer embedded in rubbery, castable, low-loss gel to enable transducer to "look" into surface of test object or human body at any desired angle. Composed of solution of water and ethylene glycol in collagen matrix. Provides total contact of water bath, also used on bodies or objects too large for water baths, even if moving. Also provides look angles of poly(methyl methacrylate) angle block with potential of reduced acoustic impedance and refraction. Custom-tailored to task at hand, and gel sufficiently inexpensive to be discarded upon completion. Easy to couple ultrasound in and out of gel, minimizing losses and artifacts of other types of standoffs employed in ultrasonic testing.

Companion, John A.↗

NDE of thermal protection system for space shuttle solid rocket booster

Potential nondestructive test (NDE) methods were evaluated for detecting debonds and weak bonds in the thermal protection system (TPS) for the space shuttle solid rocket boosters. The primary thermal protection material is a sprayable, thick epoxy coating that is filled with lightweight and thermal insulating materials. Test panels were fabricated with a wide variety of hidden realistic defects, including contact debonds and weak bonds. Nondestructive test results were obtained. Candidate NDE methods evaluated for booster production applications include laser interferometry (e.g., electronic shearography), infrared thermography, radiography (e.g., computed tomography), acousto-ultrasonics, mechanical/acoustic impedance, ultrasonics, acoustic emission, and the tap test. Capabilities, advantages, disadvantages, and relative performances in defect detection of each test method for TPS bonding applications are reported. Electronic shearography NDE was technically the superior method for detecting debonds.