Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Compatibility error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

DISCO: A 3D MOVING-MESH MAGNETOHYDRODYNAMICS CODE DESIGNED FOR THE STUDY OF ASTROPHYSICAL DISKS

This work presents the publicly available moving-mesh magnetohydrodynamics (MHD) code DISCO. DISCO is efficient and accurate at evolving orbital fluid motion in two and three dimensions, especially at high Mach numbers. DISCO employs a moving-mesh approach utilizing a dynamic cylindrical mesh that can shear azimuthally to follow the orbital motion of the gas. The moving mesh removes diffusive advection errors and allows for longer time-steps than a static grid. MHD is implemented in DISCO using an HLLD Riemann solver and a novel constrained transport (CT) scheme that is compatible with the mesh motion. DISCO is tested against a wide variety of problems, which are designed to test its stability, accuracy, and scalability. In addition, several MHD tests are performed which demonstrate the accuracy and stability of the new CT approach, including two tests of the magneto-rotational instability, one testing the linear growth rate and the other following the instability into the fully turbulent regime.

79 ASTRONOMY AND ASTROPHYSICS↗

Subplane Decusping for BWRs in MPACT

Control blade cusping can introduce significant error in boiling water reactor (BWR) calculations with MPACT when blade tips fall partway within an axial method of characteristics (MOC) plane, requiring homogenization of controlled and uncontrolled regions. This work implements subplane decusping for BWRs in MPACT by enabling BWR-compatible subplane coarse mesh finite difference (CMFD) and extending the existing decusping framework to represent between-assembly control blades that insert from the bottom of the core. The method resolves axial heterogeneity on a refined subplane mesh in the low-order solve and uses the resulting subplane flux shape to form flux-volume homogenized transport cross sections for the partially rodded MOC plane. The capability is evaluated using a single physics General Electric (GE)-14 assembly and a multiphysics Peach Bottom Unit 2 Type 1 assembly (PB2T1A) with thermal hydraulic feedback. In both cases, coarse axial meshes with and without subplane decusping are compared against fine mesh reference solutions over the full range of blade withdrawal positions. Subplane decusping reduces maximum/average eigenvalue errors from 3,369/220 pcm to 303/36 pcm for GE-14 and from 6,689/585 pcm to 1,582/109 pcm for PB2T1A. Additionally, it reduces pin power root mean square errors from 5.2%/0.8% to 1.8%/0.2% for GE-14 and from 6.9%/0.6% to 2.3%/0.1% for PB2T1A. These results demonstrate an effective, practical correction for BWR blade cusping in VERA-MPACT.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Optical tomography reconstruction algorithm with the finite element method: An optimal approach with regularization tools

Highlights: •New strategies to improve the accuracy of the reconstruction through mesh and finite element parameterization. •Use of gradient filtering through an alternative inner product within the adjoint method. •An integral form of the cost function is used to make the reconstruction compatible with all finite element formulations, continuous and discontinuous. •Gradient-based algorithm with the adjoint method is used for the reconstruction. -- Abstract: Optical tomography is mathematically treated as a non-linear inverse problem where the optical properties of the probed medium are recovered through the minimization of the errors between the experimental measurements and their predictions with a numerical model at the locations of the detectors. According to the ill-posed behavior of the inverse problem, some regularization tools must be performed and the Tikhonov penalization type is the most commonly used in optical tomography applications. This paper introduces an optimized approach for optical tomography reconstruction with the finite element method. An integral form of the cost function is used to take into account the surfaces of the detectors and make the reconstruction compatible with all finite element formulations, continuous and discontinuous. Through a gradient-based algorithm where the adjoint method is used to compute the gradient of the cost function, an alternative inner product is employed for preconditioning the reconstruction algorithm. Moreover, appropriate re-parameterization of the optical properties is performed. These regularization strategies are compared with the classical Tikhonov penalization one. It is shown that both the re-parameterization and the use of the Sobolev cost function gradient are efficient for solving such an ill-posed inverse problem.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On the computational solution of vector-density based continuum dislocation dynamics models: A comparison of two plastic distortion and stress update algorithms

Continuum dislocation dynamics models of mesoscale plasticity consist of dislocation transport-reaction equations coupled with crystal mechanics equations. The coupling between these two sets of equations is such that dislocation transport gives rise to the evolution of plastic distortion (strain), while the evolution of the latter fixes the stress from which the dislocation velocity field is found via a mobility law. Earlier solutions of these equations employed a staggered solution scheme for the two sets of equations in which the plastic distortion was updated via time integration of its rate, as found from Orowan's law. In this work, we show that such a direct time integration scheme can suffer from accumulation of numerical errors. We introduce an alternative scheme based on field dislocation mechanics that ensures consistency between the plastic distortion and the dislocation content in the crystal. The new scheme is based on calculating the compatible and incompatible parts of the plastic distortion separately, and the incompatible part is calculated from the current dislocation density field. Stress field and dislocation transport calculations were implemented within a finite element based discretization of the governing equations, with the crystal mechanics part solved by a conventional Galerkin method and the dislocation transport equations by the least squares method. A simple test was first performed to show the accuracy of the two schemes for updating the plastic distortion, which shows that the solution method based on field dislocation mechanics is more accurate. This method then was used to simulate an austenitic steel crystal under uniaxial loading and multiple slip conditions. By considering dislocation interactions caused by junctions, a hardening rate similar to discrete dislocation dynamics simulation results was obtained. Finally, the simulations show that dislocations exhibit some self-organized structures as the strain is increased.

36 MATERIALS SCIENCE↗

Variation Tolerant and Energy-Efficient Charge Domain Compute-in-Memory Array with Binary and Multi-Level Cell Ferroelectric FET

Here, in this work, we present a variation-tolerant and energy-efficient charge-domain Ferroelectric FET (FeFET) based Compute-in-Memory (CiM) array design that is compatible with both binary and multi-level cell memory sensing. We demonstrate that: 1) by exploiting FeFET as a nonvolatile switch, its high ON/OFF ratio in the subthreshold region can suppress the error introduced by the inaccurate ON state conductance, thus realizing robust CiM operations, unlike the current-domain CiM design where the computation results is highly sensitive to the device conductance variation; 2) by leveraging a dense dynamic random access memory (DRAM)-like 1FeFET1C cell structure, the proposed design benefits from the existing high density DRAM establishment while also significantly relaxing the capacitor retention and transistor leakage requirement; 3) the charge-domain CiM supports both binary FeFET with minimum overhead and MLC FeFET with tolerable latency for MLC state sensing, whose efficacy is validated experimentally on both cell-level and array-level; 4) the proposed CiM shows much better device variation resilience than conventional current-domain CiM, and also improves inference accuracy. Macro-level evaluation results demonstrate significantly higher energy efficiency and area efficiency compared to prior CiM works.

Duan, Jiahui [University of Notre Dame, IN (United↗

Selecting registration schemes in case of interstitial lung disease follow-up in CT

Purpose: Primary goal of this study is to select optimal registration schemes in the framework of interstitial lung disease (ILD) follow-up analysis in CT. Methods: A set of 128 multiresolution schemes composed of multiresolution nonrigid and combinations of rigid and nonrigid registration schemes are evaluated, utilizing ten artificially warped ILD follow-up volumes, originating from ten clinical volumetric CT scans of ILD affected patients, to select candidate optimal schemes. Specifically, all combinations of four transformation models (three rigid: rigid, similarity, affine and one nonrigid: third order B-spline), four cost functions (sum-of-square distances, normalized correlation coefficient, mutual information, and normalized mutual information), four gradient descent optimizers (standard, regular step, adaptive stochastic, and finite difference), and two types of pyramids (recursive and Gaussian-smoothing) were considered. The selection process involves two stages. The first stage involves identification of schemes with deformation field singularities, according to the determinant of the Jacobian matrix. In the second stage, evaluation methodology is based on distance between corresponding landmark points in both normal lung parenchyma (NLP) and ILD affected regions. Statistical analysis was performed in order to select near optimal registration schemes per evaluation metric. Performance of the candidate registration schemes was verified on a case sample of ten clinical follow-up CT scans to obtain the selected registration schemes. Results: By considering near optimal schemes common to all ranking lists, 16 out of 128 registration schemes were initially selected. These schemes obtained submillimeter registration accuracies in terms of average distance errors 0.18 ± 0.01 mm for NLP and 0.20 ± 0.01 mm for ILD, in case of artificially generated follow-up data. Registration accuracy in terms of average distance error in clinical follow-up data was in the range of 1.985–2.156 mm and 1.966–2.234 mm, for NLP and ILD affected regions, respectively, excluding schemes with statistically significant lower performance (Wilcoxon signed-ranks test, p < 0.05), resulting in 13 finally selected registration schemes. Conclusions: Selected registration schemes in case of ILD CT follow-up analysis indicate the significance of adaptive stochastic gradient descent optimizer, as well as the importance of combined rigid and nonrigid schemes providing high accuracy and time efficiency. The selected optimal deformable registration schemes are equivalent in terms of their accuracy and thus compatible in terms of their clinical outcome.

60 APPLIED LIFE SCIENCES↗

Aftershocks of the 2012 Off-Coast of Sumatra Earthquake Sequence

Aftershocks of the 2012 Off-Coast of Sumatra Earthquake Sequence exhibit a complex and diffuse spatial distribution. The first-order complexity in aftershock distribution is clear and well beyond the influence of typical earthquake location uncertainty. The sequence included rupture of multiple fault segments, spatially separated. We use surface-wave based relative centroid locations to examine whether, at the small scale, the distribution of the aftershocks was influenced by location errors. Surface-wave based relative location has delineated precise oceanic transform fault earthquake locations in multiple regions. However, the relocated aftershocks off the coast of Sumatra seldom align along simple linear trends that are compatible with the corresponding fault strikes as estimated for the GCMT catalog. The relocation of roughly 60 moderate-earthquake epicentroids suggests that the faulting involved in the 2012 earthquake aftershock sequence included strain release along many short fault segments. Statistical analysis and temporal variations of aftershocks show a typical decay of the aftershocks but a relatively low number of aftershocks, as is common for intraplate oceanic earthquakes. Coulomb stress calculations indicate that most of the moderate-magnitude aftershocks are compatible with stress changes predicted by the large-event slip models. Furthermore the patterns in the aftershocks suggest that the formation of the boundary and eventual localization of deformation between the Indian and Australian plate is a complicated process.

2012 Sumatra Earthquake↗

Measurement of Atmospheric Neutrino Oscillation Parameters Using Convolutional Neural Networks with 9.3 Years of Data in IceCube DeepCore

The DeepCore subdetector of the IceCube Neutrino Observatory provides access to neutrinos with energies above approximately 5 GeV. Data taken between 2012 and 2021 (3387 days) are utilized for an atmospheric ν μ disappearance analysis that studied 150 257 neutrino-candidate events with reconstructed energies between 5 and 100 GeV. An advanced reconstruction based on a convolutional neural network is applied, providing increased signal efficiency and background suppression, resulting in a measurement with both significantly increased statistics compared to previous DeepCore oscillation results and high neutrino purity. For the normal neutrino mass ordering, the atmospheric neutrino oscillation parameters and their 1 σ errors are measured to be Δ m 32 2 = 2.40 − 0.04 + 0.05 × 10 − 3 eV 2 and sin 2 θ 23 = 0.54 − 0.03 + 0.04 . The results are the most precise to date using atmospheric neutrinos, and are compatible with measurements from other neutrino detectors including long-baseline accelerator experiments. Published by the American Physical Society 2025

Abbasi, R.↗

MO-AB-BRA-09: Temporally Realistic Manipulation a 4D Biomechanical Lung Phantom for Evaluation of Simultaneous Registration and Segmentation

Purpose: To produce multi-modality compatible, realistic datasets for the joint evaluation of segmentation and registration with a reliable ground truth using a 4D biomechanical lung phantom. The further development of a computer controlled air flow system for recreation of real patient breathing patterns is incorporated for additional evaluation of motion prediction algorithms. Methods: A pair of preserved porcine lungs was pneumatically manipulated using an in-house computer controlled respirator. The respirator consisted of a set of bellows actuated by a 186 W computer controlled industrial motor. Patient breathing traces were recorded using a respiratory bellows belt during CT simulation and input into a control program incorporating a proportional-integral-derivative (PID) feedback controller in LabVIEW. Mock tumors were created using dual compartment vacuum sealed sea sponges. 65% iohexol,a gadolinium-based contrast agent and 18F-FDG were used to produce contrast and thus determine a segmentation ground truth. The intensity distributions of the compartments were then digitally matched for the final dataset. A bifurcation tracking pipeline provided a registration ground truth using the bronchi of the lung. The lungs were scanned using a GE Discovery-ST PET/CT scanner and a Phillips Panorama 0.23T MRI using a T1 weighted 3D fast field echo (FFE) protocol. Results: The standard deviation of the error between the patient breathing trace and the encoder feedback from the respirator was found to be ±4.2%. Bifurcation tracking error using CT (0.97×0.97×3.27 mm{sup 3} resolution) was found to be sub-voxel up to 7.8 cm displacement for human lungs and less than 1.32 voxel widths in any axis up to 2.3 cm for the porcine lungs. Conclusion: An MRI/PET/CT compatible anatomically and temporally realistic swine lung phantom was developed for the evaluation of simultaneous registration and segmentation algorithms. With the addition of custom software and mock tumors, the entire package offers ground truths for benchmarking performance with high fidelity.

60 APPLIED LIFE SCIENCES↗

CT reconstruction techniques for improved accuracy of lung CT airway measurement

Purpose: To determine the impact of constrained reconstruction techniques on quantitative CT (qCT) of the lung parenchyma and airways for low x-ray radiation dose. Methods: Measurement of small airways with qCT remains a challenge, especially for low x-ray dose protocols. Images of the COPDGene quality assurance phantom (CTP698, The Phantom Laboratory, Salem, NY) were obtained using a GE discovery CT750 HD scanner for helical scans at x-ray radiation dose-equivalents ranging from 1 to 4.12 mSv (12–100 mA s current–time product). Other parameters were 40 mm collimation, 0.984 pitch, 0.5 s rotation, and 0.625 mm thickness. The phantom was sandwiched between 7.5 cm thick water attenuating phantoms for a total length of 20 cm to better simulate the scatter conditions of patient scans. Image data sets were reconstructed using STANDARD (STD), DETAIL, BONE, and EDGE algorithms for filtered back projection (FBP), 100% adaptive statistical iterative reconstruction (ASIR), and Veo reconstructions. Reduced (half) display field of view (DFOV) was used to increase sampling across airway phantom structures. Inner diameter (ID), wall area percent (WA%), and wall thickness (WT) measurements of eight airway mimicking tubes in the phantom, including a 2.5 mm ID (42.6 WA%, 0.4 mm WT), 3 mm ID (49.0 WA%, 0.6 mm WT), and 6 mm ID (49.0 WA%, 1.2 mm WT) were performed with Airway Inspector (Surgical Planning Laboratory, Brigham and Women’s Hospital, Boston, MA) using the phase congruency edge detection method. The average of individual measures at five central slices of the phantom was taken to reduce measurement error. Results: WA% measures were greatly overestimated while IDs were underestimated for the smaller airways, especially for reconstructions at full DFOV (36 cm) using the STD kernel, due to poor sampling and spatial resolution (0.7 mm pixel size). Despite low radiation dose, the ID of the 6 mm ID airway was consistently measured accurately for all methods other than STD FBP. Veo reconstructions showed slight improvement over STD FBP reconstructions (4%–9% increase in accuracy). The most improved ID and WA% measures were for the smaller airways, especially for low dose scans reconstructed at half DFOV (18 cm) with the EDGE algorithm in combination with 100% ASIR to mitigate noise. Using the BONE + ASIR at half BONE technique, measures improved by a factor of 2 over STD FBP even at a quarter of the x-ray dose. Conclusions: The flexibility of ASIR in combination with higher frequency algorithms, such as BONE, provided the greatest accuracy for conventional and low x-ray dose relative to FBP. Veo provided more modest improvement in qCT measures, likely due to its compatibility only with the smoother STD kernel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Protected gates for topological quantum field theories

We study restrictions on locality-preserving unitary logical gates for topological quantum codes in two spatial dimensions. A locality-preserving operation is one which maps local operators to local operators — for example, a constant-depth quantum circuit of geometrically local gates, or evolution for a constant time governed by a geometrically local bounded-strength Hamiltonian. Locality-preserving logical gates of topological codes are intrinsically fault tolerant because spatially localized errors remain localized, and hence sufficiently dilute errors remain correctable. By invoking general properties of two-dimensional topological field theories, we find that the locality-preserving logical gates are severely limited for codes which admit non-abelian anyons, in particular, there are no locality-preserving logical gates on the torus or the sphere with M punctures if the braiding of anyons is computationally universal. Furthermore, for Ising anyons on the M-punctured sphere, locality-preserving gates must be elements of the logical Pauli group. We derive these results by relating logical gates of a topological code to automorphisms of the Verlinde algebra of the corresponding anyon model, and by requiring the logical gates to be compatible with basis changes in the logical Hilbert space arising from local F-moves and the mapping class group.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mechanical Design of a UHV Non-magnetic Kappa Diffractometer

A UHV non-magnetic kappa geometry diffractometer has been designed for the resonant soft X-ray scattering (RSXS) branch of the Intermediate Energy X-ray (IEX) beamline at the Advanced Photon Source (APS), Argonne National Laboratory. The kappa geometry allows for a large q-range and space for a sample environment (electric or magnetic fields). To avoid distorting the sample environment field, non-magnetic SmarAct, GmbH stages are used for the 4)-axis, X, Y, and Z linear stages. The ic and 0 axes are controlled by high-precision UHV compatible Physik Instrumente (PI) GmbH & Co. rotation stages. The design goal was to achieve a 50 gm sphere of confusion. To achieve this, iterative designs were developed using FEA and commercial stages were chosen that had minimal wobble, eccentricity, and flatness errors.

X-ray diffractometer↗

Solvent selection for biphasic extraction of 5-hydroxymethylfurfural via multiscale modeling and experiments

We introduce a comprehensive conceptual framework for selecting solvents for reactive extraction in biphasic organic-water systems and demonstrate it for the separation of HMF (5-hydroxylmethylfurfural), a platform chemical produced in the acid-catalyzed dehydration of hexoses. We first perform in silico screening of ~2500 solvents, from the ADFCRS-2018 database using the ADF COSMO-RS implementation, and classification, based on the solvent partition coefficient. We then determine experimentally the partition coefficients for HMF, fructose, and products of HMF rehydration (levulinic acid (LA), and formic acid (FA)), the mutual water-organic solvent solubilities, and the separation factors in >50 select solvents spanning multiple homologous series at room temperature and a typical reaction temperature with in situ sampling. We find that COSMO-RS is excellent for screening purposes (typical error in most cases within a factor of ~2). Increased temperatures lead to significant reduction in partitioning, and room temperature measurements are clearly inadequate for solvent selection. Upon down selecting classes of solvents based on separation performance, we perform experimental thermal stability and reaction compatibility studies of a small set of solvents at relevant reactive-extraction temperatures. We discover that many substituted phenols exhibit an order-of-magnitude increase in partitioning compared to conventional solvents due chiefly to hydrogen bond interactions and show the necessary stability but retain a significant fraction of water and LA, factors that need to be considered in technoeconomic analysis. In contrast, anilines, aldehydes, and acids are good to excellent regarding separation but incompatible with this specific reaction medium. Furthermore, this multifaceted framework can be extended to other biomass-derived products and processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-F-J-158: Respiratory Motion Resolved, Self-Gated 4D-MRI Using Rotating Cartesian K-Space Sampling

Purpose: Dynamic MRI has been used to quantify respiratory motion of abdominal organs in radiation treatment planning. Many existing 4D-MRI methods based on 2D acquisitions suffer from limited slice resolution and additional stitching artifacts when evaluated in 3D{sup 1}. To address these issues, we developed a 4D-MRI (3D dynamic) technique with true 3D k-space encoding and respiratory motion self-gating. Methods: The 3D k-space was acquired using a Rotating Cartesian K-space (ROCK) pattern, where the Cartesian grid was reordered in a quasi-spiral fashion with each spiral arm rotated using golden angle{sup 2}. Each quasi-spiral arm started with the k-space center-line, which were used as self-gating{sup 3} signal for respiratory motion estimation. The acquired k-space data was then binned into 8 respiratory phases and the golden angle ensures a near-uniform k-space sampling in each phase. Finally, dynamic 3D images were reconstructed using the ESPIRiT technique{sup 4}. 4D-MRI was performed on 6 healthy volunteers, using the following parameters (bSSFP, Fat-Sat, TE/TR=2ms/4ms, matrix size=500×350×120, resolution=1×1×1.2mm, TA=5min, 8 respiratory phases). Supplemental 2D real-time images were acquired in 9 different planes. Dynamic locations of the diaphragm dome and left kidney were measured from both 4D and 2D images. The same protocol was also performed on a MRI-compatible motion phantom where the motion was programmed with different amplitude (10–30mm) and frequency (3–10/min). Results: High resolution 4D-MRI were obtained successfully in 5 minutes. Quantitative motion measurements from 4D-MRI agree with the ones from 2D CINE (<5% error). The 4D images are free of the stitching artifacts and their near-isotropic resolution facilitates 3D visualization and segmentation of abdominal organs such as the liver, kidney and pancreas. Conclusion: Our preliminary studies demonstrated a novel ROCK 4D-MRI technique with true 3D k-space encoding and respiratory motion self-gating. The technique leads to high-resolution and artifacts-free 4D images for improved abdominal organ motion studies. K.S acknowledges funding support from NIH R01CA188300.

60 APPLIED LIFE SCIENCES↗

CCSI Toolset 3.19 Release

CCSI Toolset 3.19 Release Highlights A gradient generation tool was developed to support GENN models in FOQUS. Certain machine learning tools train gradient-enhanced neural network (GENN) models which can be more accurate for complex datasets given a priori knowledge of model derivatives. However, the derivatives must be known beforehand and are not often available for process data. This tool automatically predicts the gradients for a training dataset in a form usable by common GENN trainers, such as Surrogate Modeling Toolbox. Support was added for Surrogate Modeling Toolbox GENN models in FOQUS, including updates to the run methods, node properties, test framework, documentation and optional dependencies list. Users can train/save Surrogate Modeling Toolbox gradient-enhanced neural network (GENN) models with custom objects and produce .pkl files compatible with the Machine Learning/Artificial Intelligence Plugin in FOQUS. A simpler implementation of the ordering algorithm in the Sequential Design of Experiments (SDOE) module was included. The SDOE examples documentation was updated. The Optimality-Based Design of Experiments was updated to improve the error handling when the results are None.

AS↗

Using observational mean-flow data to drive large-eddy simulations of a diurnal cycle at the SWiFT site

Reproducing realistic date- and site-specific unsteady wind conditions in large-eddy simulations is becoming increasingly useful in wind energy. How to run a large-eddy simulation to match observed conditions, however, remains an open research question. One approach that has received considerable attention is mesoscale-to-microscale coupling, in which information about the mesoscale weather, most commonly acquired from a mesoscale numerical weather model, is passed on to a microscale model. In this paper, we demonstrate how the recently developed profile-assimilation technique, a form of mesoscale-to-microscale coupling, can be used to drive large-eddy simulations solely based on observed mean-flow profiles at a single location, bypassing the need for auxiliary mesoscale simulations. The new approach is evaluated for a diurnal cycle at the Scaled Wind Farm Technology site. Observed mean-flow profiles from the ground up to a height of 2 km are reconstructed by aggregating measurements from multiple instruments, and gaps in the data are infilled with natural neighbor interpolation. We perform nine simulations using various forcing approaches to deal with data limitations. The results show that it is indeed possible to drive microscale large-eddy simulation with observations using the profile-assimilation technique, notwithstanding large gaps in virtual potential temperature measurements. However, profile assimilation with vertical smoothing of the error between the desired and actual profiles is required. Without that smoothing, the microscale simulations develop unrealistically high turbulence levels under many situations. Finally, we show that simulated mesoscale data can account for missing observations, although care is needed as both data sources are not necessarily compatible.

17 WIND ENERGY↗

Study of the agreement between binary neutron star ejecta models derived from numerical relativity simulations

Neutron star mergers have recently become a tool to study extreme gravity, nucleosynthesis, and the chemical composition of the Universe. To date, there has been one joint gravitational and electromagnetic observation of a binary neutron star merger, GW170817, as well as a solely gravitational observation, GW190425. In order to accurately identify and interpret electromagnetic signals of neutron star mergers, better models of the matter outflows generated by these mergers are required. We compare a series of ejecta models to see where they provide strong constraints on the amount of ejected mass expected from a system, and where systematic uncertainties in current models prevent us from reliably extracting information from observed events. We also examine 2396 neutron star equations of state compatible with GW170817 to see whether a given ejecta mass could be reasonably produced with a neutron star of said equation of state, and whether different ejecta models provide consistent predictions. We find that the difference between models is often comparable to or larger than the error generally assumed for these models, implying better constraints on the models are needed. In conclusion, we also note that the extrapolation of outflow models outside of their calibration window, while commonly needed to analyze gravitational wave events, is extremely unreliable and occasionally leads to completely unphysical results.

79 ASTRONOMY AND ASTROPHYSICS↗

Key materials of vanadium flow batteries: electrolytes

Electrolytes not only dictates the device performance, but also the major part of VRFB system cost, making it as main focus of extensive research efforts in this field. Most research efforts directed towards finding an optimal supporting electrolyte and/or additive materials, which can increase the vanadium cations solubility and stability. Current research efforts were mostly trial and error methods, yielding marginal improvements in chemical/thermal stability while potentially compromising on other functional properties such as conductivity and viscosity. In addition, any supporting electrolyte and/or additives used to enhance vanadium solubility or cell potential will eventually diffuse across the membrane making it necessary to be compatible with both half-cell reactions to ensure long battery life. Another aspect of ensuring longer battery life cycle with minimum self-discharge of VRFB would be the additive/supporting electrolyte should exhibit prolonged thermal and chemical stability, typically over 30 days at battery operating temperature of -5 to 50 C. These practical requirements may limit the implementation of many additives currently under investigation. Despite extensive research, identifying the optimal material for stabilizing the vanadium electrolyte has been rather slow owing to the widely used empirical approach.

Murugesan, Vijayakumar↗