Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Common bus”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Making Data Prefetch Smarter: Adaptive Prefetching on POWER7

Hardware data prefetch engines are integral parts of many general purpose server-class microprocessors in the eld to- day. Some prefetch engines allow the user to change some of their parameters. The prefetcher, however, is usually enabled in a default conguration during system bring-up and dynamic reconguration of the prefetch engine is not an autonomic feature of current machines. Conceptually, however, it is easy to infer that commonly used prefetch algorithms, when applied in a xed mode will not help per- formance in many cases. In fact, they may actually de- grade performance due to useless bus bandwidth consump- tion and cache pollution. In this paper, we present an adap- tive prefetch scheme that dynamically modies the prefetch settings in order to adapt to the workload requirements. We implement and evaluate adaptive prefetching in the con- text of an existing, commercial processor, namely the IBM POWER7. Our adaptive prefetch mechanism improves per- formance with respect to the default prefetch setting up to 2.7X and 30% for single-threaded and multiprogrammed workloads, respectively. Categories

Jimenez, Victor↗

Space station common module thermal management: Design and construction of a test bed

In this project, a thermal test bed was designed, simulated, and planned for construction. The thermal system features interior and exterior thermal loads and interfacing with the central-radiator thermal bus. Components of the test bed include body mounted radiator loop with interface heat exchangers (600 Btu/hr); an internal loop with cabin air-conditioning and cold plates (3400 Btu/hr); interface heat exchangers to the central bus (13,000 Btu/hr); and provisions for new technology including advanced radiators, thermal storage, and refrigeration. The apparatus will be mounted in a chamber, heated with lamps, and tested in a vacuum chamber with LN2-cooled walls. Simulation of the test bed was accomplished using a DEC PRO 350 computer and the software package TK! olver. Key input variables were absorbed solar radiation and cold plate loads. The results indicate temperatures on the two loops will be nominal when the radiation and cold plate loads are in the range of 25% to 75% of peak loads. If all loads fall to zero, except the cabin air system which was fixed, the radiator fluid will drop below -100 F and may cause excessive pressure drop. If all loads reach 100%, the cabin air temperature could rise to 96 F.

Barile, R. G.↗

Inverter Output Filter Effect on PWM Motor Drives of a Flywheel Energy Storage System

NASA Glenn Research Center (GRC) has been involved in the research and development of high speed flywheel systems for small satellite energy storage and attitude control applications. One research and development area has been the minimization of the switching noise produced by the pulsed width modulated (PWM) inverter that drives the flywheel permanent magnet motor/generator (PM M/G). This noise can interfere with the flywheel M/G hardware and the system avionics hampering the full speed performance of the flywheel system. One way to attenuate the inverter switching noise is by placing an AC filter at the three phase output terminals of the inverter with the filter neutral point connected to the DC link (DC bus) midpoint capacitors. The main benefit of using an AC filter in this fashion is the significant reduction of the inverter s high dv/dt switching and its harmonics components. Additionally, common mode (CM) and differential mode (DM) voltages caused by the inverter s high dv/dt switching are also reduced. Several topologies of AC filters have been implemented and compared. One AC filter topology consists of a two-stage R-L-C low pass filter. The other topology consists of the same two-stage R-L-C low pass filter with a series connected trap filter (an inductor and capacitor connected in parallel). This paper presents the analysis, design and experimental results of these AC filter topologies and the comparison between the no filter case and conventional AC filter.

Santiago, Walter↗

A Novel Decentralized PWM Interleaving Technique for Ripple Minimization in Series-Stacked DC-DC Converters

Cascaded dc-dc converters are commonly used in applications where distributed energy sources or loads are connected to elevated voltage levels for power transfer. In such systems, it is advantageous to minimize the ripple on the bus current and voltage by proper phase shifting of the pulse-width modulation (PWM) pulses among the converters via a method known as interleaving. Existing approaches use either a centralized controller or separate communication lines among the stacked converters to control their relative PWM switch transitions. The key drawbacks are that these methods entail significant wiring, the central controller acts as a single point of failure, and implementation on very large numbers of units is impractical. In this paper, we introduce a decentralized interleaving control (DIC) strategy that acts on local current measurements at every converter and achieves communication-free PWM interleaving among the series-stacked converters. The proposed controller is simple in structure and is shown to converge asymptotically to the interleaved state irrespective of clock drifts among the digital signal processors. Experimental results are provided for a system of five series-connected converters showing a 10× reduction in the current ripple compared to normal operation.

cascaded converter↗

Dynamic Interaction of Grid-Forming and Grid-Following Inverters with Synchronous Generators in Hybrid Power Plants

As the integration of renewable energy resources such as wind and solar generation continues to grow, the use of hybrid power plants with both synchronous machines and power electronic inverters operating in parallel becomes more common. This paper studies the impact on small-signal stability for these pairs of devices, first as an isolated two-device system and then as part of a 9-bus test system. Each operational scenario was studied with both a grid-following inverter and a grid-forming inverter. In each scenario, the state variables associated with the synchronous generator's excitation system were found to be responsible for the inception of instability. These results underscore the importance of accurate modeling of excitation systems when modeling power systems with hybrid power plants.

hybrid power plant↗

Advanced information processing system: The Army fault tolerant architecture conceptual study. Volume 2: Army fault tolerant architecture design and analysis

Described here is the Army Fault Tolerant Architecture (AFTA) hardware architecture and components and the operating system. The architectural and operational theory of the AFTA Fault Tolerant Data Bus is discussed. The test and maintenance strategy developed for use in fielded AFTA installations is presented. An approach to be used in reducing the probability of AFTA failure due to common mode faults is described. Analytical models for AFTA performance, reliability, availability, life cycle cost, weight, power, and volume are developed. An approach is presented for using VHSIC Hardware Description Language (VHDL) to describe and design AFTA's developmental hardware. A plan is described for verifying and validating key AFTA concepts during the Dem/Val phase. Analytical models and partial mission requirements are used to generate AFTA configurations for the TF/TA/NOE and Ground Vehicle missions.

Harper, R. E.↗

A Novel Decentralized PWM Interleaving Technique for Ripple Minimization in Series-Stacked DC-DC Converters: Preprint

Cascaded dc-dc converters are commonly used in applications where distributed energy sources or loads are connected to elevated voltage levels for power transfer. In such systems, it is advantageous to minimize the ripple on the bus current and voltage by proper phase shifting of the pulse-width modulation (PWM) pulses among the converters via a method known as interleaving. Existing approaches use either a centralized controller or separate communication lines among the stacked converters to control their relative PWM switch transitions. The key drawbacks are that these methods entail significant wiring, the central controller acts as a single point of failure, and implementation on very large numbers of units is impractical. In this paper, we introduce a decentralized interleaving control (DIC) strategy that acts on local current measurements at every converter and achieves communication-free PWM interleaving among the series-stacked converters. The proposed controller is simple in structure and is shown to converge asymptotically to the interleaved state irrespective of clock drifts among the digital signal processors. Experimental results are provided for a system of five series-connected converters showing a 10 times reduction in the current ripple compared to normal operation.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Dynamic Modeling of Power Conversion Stages for an Exascale Supercomputer

In this paper a power conversion and energy consumption model for an exascale supercomputer is investigated. Power consumption, energy loss and efficiency are derived for the 27.2 MW liquid-cooled, centralized, High Performance Computing (HPC) power system, which is supplied directly from the 480 V three-phase mains. Two energy conversion stages are analyzed, measured and modeled. The model is developed in order to be adapted and implemented in a digital twin platform utilizing a Resource Allocator and Power Simulator (RAPS) module. RAPS enables estimation of potential energy savings in the direct AC power supply architecture via both conventional rectifier load sharing (commonly used in HPC systems), as well as smart rectifier load sharing. Moreover, besides the direct AC supply architecture analysis, the full direct DC supply architecture with with 1 kV DC bus were also studied. Comparison of 10 hour time frame operation of the system, with direct 480 V AC voltage supply with conventional and smart load sharing and medium dc voltage supply were done. For the direct AC supply architecture, with conventional and smart load sharing the predicted power loss was approximately 840 kW and 820 kW, respectively and the predicted total system efficiency was 92.87% and 93.05%, respectively. For the direct DC supply architecture with the 1000 V DC supply bus power loss was approximately 340 kW and the predicted total system efficiency was 97.02%.

Wojda, Rafal↗

High-fidelity quantum memory using nitrogen-vacancy center ensemble for hybrid quantum computation

We study a hybrid quantum computing system using a nitrogen-vacancy center ensemble (NVE) as quantum memory, a current-biased Josephson junction (CBJJ) superconducting qubit fabricated in a transmission line resonator (TLR) as the quantum computing processor, and the microwave photons in TLR as the quantum data bus. The storage process is seriously treated by considering all kinds of decoherence mechanisms. Such a hybrid quantum device can also be used to create multiqubit W states of NVEs through a common CBJJ. The experimental feasibility is achieved using currently available technology.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Columbus Payloads Flow Rate Anomalies

The Columbus Active Thermal Control System (ATCS) is the main thermal bus for the pressurized racks working inside the European laboratory. One of the ATCS goals is to provide proper water flow rate to each payload (P/L) by controlling actively the pressure drop across the common plenum distribution piping. Overall flow measurement performed by the Water Pump Assembly (WPA) is the only flow rate monitor available at system level and is not part of the feedback control system. At rack activation the flow rate provided by the system is derived on ground by computing the WPA flow increase. With this approach, several anomalies were raised during these 3 years on-orbit, with the indication of low flow rate conditions on the European racks FSL, BioLab, EDR and EPM. This paper reviews the system and P/Ls calibration approach, the anomalies occurred, the engineering evaluation on the measurement approach and the accuracy improvements proposed, the on-orbit test under evaluation with NASA and finally discusses possible short and long term solutions in case of anomaly confirmation.

Quaranta, Albino↗

A Data Exchange Interface for a Standards Based Data Integration Platform

The modern electrical grid is a complex and a data rich system, requiring several sub-systems to provide the capability and support needed to perform functions such as distributed energy resource management, outage management, and fault location and isolation, to name a few. There is a need to develop software solutions and platforms that provide an integrated infrastructure to allow interoperability between these subsystems, while leveraging the abundant data available from today’s grid. In this paper, we present the development and deployment of an application service to integrate GridAPPS-D which is an open source, standards-based software platform with SurvalentONE, a commonly used DNP3 based ADMS platform that allows operation, monitoring, analysis, restoration, and optimization of network operations. We present details of the integration architecture, including its implementation, and provide results from functional testing of the architecture on a 13 bus IEEE system. The results validate that the integration is successful and is able to provide a two-way exchange of communication and translation between different communication protocols.

Singh, Alka↗

High-frequency ac power distribution in Space Station

A utility-type 20-kHz ac power distribution system for the Space Station, employing resonant power-conversion techniques, is presented. The system converts raw dc voltage from photovoltaic cells or three-phase LF ac voltage from a solar dynamic generator into a regulated 20-kHz ac voltage for distribution among various loads. The results of EASY5 computer simulations of the local and global performance show that the system has fast response and good transient behavior. The ac bus voltage is effectively regulated using the phase-control scheme, which is demonstrated with both line and load variations. The feasibility of paralleling the driver-module outputs is illustrated with the driver modules synchronized and sharing a common feedback loop. An HF sinusoidal ac voltage is generated in the three-phase ac input case, when the driver modules are phased 120 deg away from one another and their outputs are connected in series.

Tsai, Fu-Sheng↗

Implementing Ethernet Services on the Payload Executive Processor (PEP)

The Ethernet interface is more common and easier interface to implement for payload developers already familiar with Ethernet protocol in their labs. The Ethernet interface allows for a more distributed payload architecture. Connections can be placed in locations not serviced by the PEP 1553 bus. The Ethernet interface provides a new access port into the PEP so as to use the already existing services. Initial capability will include a subset of services with a plan to expand services later.

Pruett, David↗

Command Interface ASIC - Analog Interface ASIC Chip Set

A command interface application-specific integrated circuit (ASIC) and an analog interface ASIC have been developed as a chip set for remote actuation and monitoring of a collection of switches, which can be used to control generic loads, pyrotechnic devices, and valves in a high-radiation environment. The command interface ASIC (CIA) can be used alone or in combination with the analog interface ASIC (AIA). Designed primarily for incorporation into spacecraft control systems, they are also suitable for use in high-radiation terrestrial environments (e.g., in nuclear power plants and facilities that process radioactive materials). The primary role of the CIA within a spacecraft or other power system is to provide a reconfigurable means of regulating the power bus, actuating all valves, firing all pyrotechnic devices, and controlling the switching of power to all switchable loads. The CIA is a mixed-signal (analog and digital) ASIC that includes an embedded microcontroller with supporting fault-tolerant switch control and monitoring circuitry that is capable of connecting to a redundant set of interintegrated circuit (I(sup 2)C) buses. Commands and telemetry requests are communicated to the CIA. Adherence to the I(sup 2)C bus standard helps to reduce development costs by facilitating the use of previously developed, commercially available components. The AIA is a mixed-signal ASIC that includes the analog circuitry needed to connect the CIA to a custom higher powered version of the I(sup 2)C bus. The higher-powered version is designed to enable operation with bus cables longer than those contemplated in the I(sup 2)C standard. If there are multiple higher-power I(sup 2)C-like buses, then there must an AIA between the CIA and each such bus. The AIA includes two identical interface blocks: one for the side-A I(sup 2)C clock and data buses and the other for the side B buses. All the AIAs on each side are powered from a common power converter module (PCM). Sides A and B of the I(sup 2)C buses are electrically isolated from each other (see figure). They are also isolated from the CIA by use of transformer coupling of signals between the AIA blocks and the CIA.

Ruiz, Baldes↗

Reusable Rack Interface Controller Common Software for Various Science Research Racks on the International Space Station

The purpose of the EXPRESS (Expedite the PRocessing of Experiments to Space Station) rack project is to provide a set of predefined interfaces for scientific payloads which allow rapid integration into a payload rack on International Space Station (ISS). VxWorks' was selected as the operating system for the rack and payload resource controller, primarily based on the proliferation of VME (Versa Module Eurocard) products. These products provide needed flexibility for future hardware upgrades to meet everchanging science research rack configuration requirements. On the International Space Station, there are multiple science research rack configurations, including: 1) Human Research Facility (HRF); 2) EXPRESS ARIS (Active Rack Isolation System); 3) WORF (Window Observational Research Facility); and 4) HHR (Habitat Holding Rack). The RIC (Rack Interface Controller) connects payloads to the ISS bus architecture for data transfer between the payload and ground control. The RIC is a general purpose embedded computer which supports multiple communication protocols, including fiber optic communication buses, Ethernet buses, EIA-422, Mil-Std-1553 buses, SMPTE (Society Motion Picture Television Engineers)-170M video, and audio interfaces to payloads and the ISS. As a cost saving and software reliability strategy, the Boeing Payload Software Organization developed reusable common software where appropriate. These reusable modules included a set of low-level driver software interfaces to 1553B. RS232, RS422, Ethernet buses, HRDL (High Rate Data Link), video switch functionality, telemetry processing, and executive software hosted on the FUC computer. These drivers formed the basis for software development of the HRF, EXPRESS, EXPRESS ARIS, WORF, and HHR RIC executable modules. The reusable RIC common software has provided extensive benefits, including: 1) Significant reduction in development flow time; 2) Minimal rework and maintenance; 3) Improved reliability; and 4) Overall reduction in software life cycle cost. Due to the limited number of crew hours available on ISS for science research, operational efficiency is a critical customer concern. The current method of upgrading RIC software is a time consuming process; thus, an improved methodology for uploading RIC software is currently under evaluation.

Lu, George C.↗

A Two-Stage Quantum Reinforcement Learning Method for Multi-Objective Transmission Switching

Multi-objective transmission switching (MO-TS) problems involve the strategic reconfiguration of network topology to simultaneously optimize multiple objectives. As the system scale increases, finding feasible solutions becomes increasingly challenging due to the problem's nonlinearity and high computational complexity. To address these challenges, this paper proposes a two-stage quantum reinforcement learning method that leverages potential quantum advantages for MO-TS. In the first stage, candidate switching lines are identified using a graph-theoretical approach to reduce the problem's dimensionality. The second stage introduces a quantum-classical reinforcement learning framework, where a learnable measurement-based CNN-ResVQC architecture is developed to effectively reduce the input dimension for quantum processing, mitigate vanishing gradients, and enhance trainability while improving the quantum circuit's flexibility in modeling complex decision policies for MO-TS. Numerical studies on IEEE 14-bus, 57-bus, and 118-bus systems demonstrate that the proposed algorithm achieves superior training stability and faster convergence with approximately 1% of the network parameters required by classical algorithms, highlighting its effectiveness, efficiency, and scalability. Furthermore, the practicality is validated through its stable convergence under three common quantum noise channels.

99 GENERAL AND MISCELLANEOUS↗

A 75 kVA Intelligent Power Stages (IPS) Unit Design for Future Grid-interface Application

The demand for grid-interface converter with flexible dc bus is driven by the fast development of energy storage system (ESS), electric vehicle (EV) charging system, and versatile residential load. This paper first proposes a two-stage intelligent power stage (IPS) unit for future grid-interface applications. To achieve zero common-mode (CM) voltage emissions, step-up and step-down voltage gain, a 3-level four-switch buck-boost (3-L FSBB) dc-dc converter is adopted with fully zero voltage switching (ZVS). In one IPS unit, an advanced fiberoptic communication with sub-nanosecond synchronization is developed for different enhanced gate drivers. Moreover, an enhanced gate driver integrated current and voltage sensors is designed for monitoring and diagnostics. To achieve a whole low-profile design, three 12 oz heavy copper planar ac inductors are designed and implemented. Finally, a 75 kVA IPS unit was built to verify both the thermal and electrical design.

Cao, Yuliang↗

An Introduction to Message-Bus Architectures for Space Systems

This course presents technical and programmatic information on the development of message-based architectures for space mission ground and flight software systems. Message-based architecture approaches provide many significant advantages over the more traditional socket-based one-of-a-kind integrated system development approaches. The course provides an overview of publish/subscribe concepts, the use of common isolation layer API's, approaches to message standardization, and other technical topics. Several examples of currently operational systems are discussed and possible changes to the system discussed and time for questions and answers will be provided.

Smith, Danford↗