Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Coefficient of performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Thermal Storage Integrated into Air-Source Heat Pumps to Leverage Building Electrification: A Systematic Literature Review

Air-source heat pumps (ASHPs) can support a decarbonized economy by replacing combustion appliances in homes and electrifying heating systems in buildings. However, ASHPs have not seen significant adoption primarily due to deteriorated performance under cold conditions - at very low temperatures they require auxiliary resistance heating to meet the heating demand and defrost the evaporator. The additional heat lowers the system efficiency. Thermal energy storage (TES) is a candidate technology to help overcome some of these issues. This paper presents a systematic literature review to map the existing research on the integration of TES into ASHPs. Our review of 59 publications indicates that thermal storage increases the ASHP coefficient of performance by 27% on average, albeit with higher initial cost compared to conventional fossil-fueled heating systems. Phase change materials may be ideal to be integrated with ASHPs due to their high energy density and compact design, but only a few publications address TES sizing and design. First and Second Laws of Thermodynamics are widely used to create metrics to assess ASHP-TES integration, and only recently have cost and environmental impact been explored. This literature review suggests that more comprehensive metrics are needed to evaluate the potential benefits of ASHP-TES systems.

air source heat pump↗

Experimental study of steam-driven ejector heat pump

Ejector-driven systems have been shown to be promising for heating applications. Most of the research works have been devoted to cooling purposes, while little attention has been focused on heating applications. An experimental steam ejector heat pump system (EHP) was designed and constructed to assess its applicability to water heating applications. The effect of the primary nozzle exit position (NXP) on the performance of the steam ejector system was investigated for primary nozzle throat diameter of 1.5 mm and 2.0 mm. The ejector system was run for high-temperature evaporator (HTE) temperatures of 120, 130, and 140 °C and low-temperature evaporator (LTE) temperatures of 10, 15, and 20 °C. The target of this investigation was to attain the highest condensing temperature to be able to use the proposed system for water heating purposes. The ejector heat pump coefficient of performance (EHP COP) was used to determine the system efficiency. Larger LTE temperatures were found to result in higher EHP COPs and condensing temperatures. A maximum EHP COP of 2.02 was attained for a HTE and LTE temperatures of 120 °C and 20 °C, respectively; however only resulted in a condensing temperature of 22.88 °C. Higher HTE temperatures were found to result in higher condensing temperatures but at the cost of EHP COP.

Spitzenberger, Jeremy↗

Study and Development of an Air Conditioning System Operating on a Magnetic Heat Pump Cycle

This report describes the design of a laboratory scale demonstration prototype of an air conditioning system operating on a magnetic heat pump cycle. Design parameters were selected through studies performed by a Kennedy Space Center (KSC) System Simulation Computer Model. The heat pump consists of a rotor turning through four magnetic fields that are created by permanent magnets. Gadolinium was selected as the working material for this demonstration prototype. The rotor was designed to be constructed of flat parallel disks of gadolinium with very little space in between. The rotor rotates in an aluminum housing. The laboratory scale demonstration prototype is designed to provide a theoretical Carnot Cycle efficiency of 62 percent and a Coefficient of Performance of 16.55.

Wang, Pao-Lien↗

Experimental Evaluation of a High-Performance Cold-Climate Heat Pump Using Tandem Vapor-Injection Compressors

A high-performance cold-climate heat pump (CCHP) was developed and experimentally validated through comprehensive laboratory and field testing. The system utilized two equal-size tandem vapor-injection (VI) compressors with an inter-stage flash tank to improve efficiency and capacity retention under subfreezing conditions. Laboratory testing was conducted on a 3-ton prototype in a controlled environmental chamber equipped with calibrated thermocouples, refrigerant-side mass flow and pressure transducers, and precision airflow measurement for energy balance verification. The prototype achieved heating coefficients of performance (COPs) of 4.4 at 47 °F, 3.1 at 17 °F, and 2.0 at –13 °F, while maintaining 88% of its rated heating capacity at –13°F. These results confirm strong low-temperature performance and indicate the potential for significant reductions in electric resistance backup use. A field prototype was installed and monitored in a residential building in Fairbanks, Alaska, during a heating season. Instrumentation included real-time power, temperature, and refrigerant state measurements to evaluate performance under dynamic outdoor conditions. The heat pump operated reliably down to –30 °F, delivering 75% of its rated heating capacity with a COP of 1.8, while maintaining stable operation, effective defrost control, and indoor comfort without auxiliary heating. The combined laboratory and field results demonstrate that the tandem VI compressor configuration provides a practical and energy-efficient approach for residential heat pumps designed for cold and very cold climate regions.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Off-design performance of an organic Rankine-vapor compression cooling cycle using R1234ze(E)

In this study, a 264 kW th organic Rankine-vapor compression cycle (ORVC) was experimentally tested over a range of conditions to quantify the individual impact of off-design external conditions. The ORVC was designed to recover waste heat at 91 °C, reject heat to a liquid condenser stream at 30 °C, and produce chilled water at 7 °C. Here, the condenser heat rejection temperature was varied from 16.6 °C to 32.6 °C, the chilled water delivery temperature was varied between 2.1 °C and 13.1 °C, and the heat input temperature was varied from 91 °C to 120 °C. As the condenser heat rejection temperature decreased, the coefficient of performance (COP) of the ORVC improved from 0.558 at 30 °C to 0.682 at 16.6 °C, despite a reduction in compressor isentropic efficiency. Although the chilled water temperature variation had almost no impact on the organic Rankine cycle performance, the compressor efficiency decreased when the delivery temperature was below 7 °C. At the highest chilled water temperature, 13.1 °C, the COP of the ORVC was 0.643. Compressor stall was noted when the condenser heat rejection temperature was greater than 32.6 °C and the chilled water delivery temperature was below 2.1 °C. Increasing the driving heat source inlet temperature improved the COP of the ORVC and the thermal efficiency of the organic Rankine power cycle, while decreasing the efficiency of the compressor and the COP of vapor compression cycle. In addition, the integrated part load value of the system was determined through experimentation to be 0.682, which provides a realistic estimate of real-world performance.

30 DIRECT ENERGY CONVERSION↗

Performance of a hybrid chemical/mechanical heat pump

The authors present the design and preliminary results of the performance of a hybrid chemical/mechanical, low-lift (20 C) heat pump. Studies have indicated that this heat pump has several advantages over the traditional single fluid vapor compression (reverse Rankine) heat pump. Included in these benefits are: 1) increased COPc due to the approximation of the cycle to the Lorenz cycle and due to the availability of the heat of solution, along with the heat of vaporization, to provide cooling; and 2) ease of variation in system cooling capacity by changing the fluid composition. The system performance is predicted for a variety of refrigerant-absorbent pairs. Cooling capacity is determined for systems operating with ammonia as the refrigerant and lithium nitrate and sodium thiocyanate as the absorbents and also with water as the refrigerant and magnesium chloride, potassium hydroxide, lithium bromide, sodium hydroxide, and sulfuric acid as the absorbents. Early indications have shown that the systems operating with water as the refrigerant operate at 2-4 times the capacity of the ammonia-refrigerant-based systems. Using existing working fluids in the proposed innovative design, a coefficient-of-performance improvement of 21 percent is possible when compared to the best vapor compression systems analyzed.

Silvestri, John J.↗

Performance Evaluation and Costs of a Combined Ground Source Heat Pump and Solar Photovoltaic Storage System in an Extreme Cold Climate

This report outlines the effectiveness and economics of a ground source heat pump system installed together with solar photovoltaic panels and a battery storage system in a local community building situated in a cold climate. The community building is a tribal building located in Ruby, Alaska. Power from solar photovoltaic panels is supplemented by electricity purchased from the local community microgrid. A ground source heat pump was commissioned three years after the building was occupied, and supplements the heat generated by a boiler for both heat and domestic hot water. Data collected over the 2021-2022 heating season shows that the heat pump is providing heat to the building about 19% of the time with an average coefficient of performance of 2.68, ranging from below 2.5 in winter to above 3.0 in summer. The solar photovoltaic panels provided 4,700 kWh of power used within the building and an additional 2,900 kWh exported to the microgrid. The solar-produced power used within the building nearly offsets the estimated annual electrical draw of the heat pump of 5,700 kWh. Due to the very high costs for shipping and installation to remote locations, projects such as this, while not economically feasible if self-funded, can save the community an estimated $76,051 over a period of 20-years. Fuel prices increasing by more than 25%, or subsidized electricity prices decreasing by more than 25%, make the ground source heat pump a more viable option economically. Unsubsidized electricity prices increasing by 25% or more make a solar photovoltaic system with battery storage nearly economically viable after a 20-year period for commercial or school buildings that are not eligible for Alaska's Power Cost Equalization program.

14 SOLAR ENERGY↗

Demonstrating non-isothermal vacuum membrane air dehumidification for efficient next-generation air conditioning

Vacuum membrane air dehumidification has gained significant interest in recent years as a highly efficient means of air dehumidification. Prior theoretical modeling work by the authors introduced the Active Membrane Energy Exchanger (AMX) concept, which combines active heat exchange and vacuum membrane dehumidification into one non-isothermal system, and found that it could outperform other air conditioning technologies under many conditions. However, no experimental literature exists on combining active heat exchangers and vacuum membrane dehumidification. Here, the goal of the present study is to evaluate the dehumidification (mass transfer) performance of the AMX concept relative to isothermal membrane dehumidification through three main methodologies: (1) membrane material-level characterization, (2) experimental prototype development and testing, and (3) computational fluid dynamics (CFD) simulations. The dense membranes used in this work showed up to a 40% increase in water vapor permeance at cooler temperatures, and the prototype system showed up to a 6% increase in humidity removal when the air was simultaneously cooled. Furthermore, the membrane module-integrated heat exchange tubes provided additional mixing and turbulence, leading to a 4–8% increase in humidity removal. The upper limit coefficient of performance was equal to approximately 2.2, necessitating advanced system designs to improve efficiency. This study is the first to highlight that combining the cooling and vacuum dehumidification processes can improve dehumidification performance.

30 DIRECT ENERGY CONVERSION↗

Heating performance of a vapor compression heat pump cascaded with a thermoelectric heat pump

Air source heat pumps (ASHPs) are widely utilized for heating and cooling in residential buildings; however, their effectiveness in heating mode is compromised during extreme weather conditions. Extensive research endeavors have been undertaken to develop, test, and assess a cost-effective vapor compression ASHP suitable for cold climate regions. Further, this study takes an innovative approach by developing component and system prototypes for a cold climate heat pump. This design combines a thermoelectric heat pump (TEHP) with a traditional residential split ASHP to augment heating capacity in low ambient temperature conditions. The component and system prototypes underwent experimental testing in the psychrometric chambers. The experimental findings revealed a 13.6% to 13.7% increase in total heat pump heating capacity, accompanied by a 3.1% to 5.0% decrease in the coefficient of performance (COP) at ambient temperatures of -15°C and -19°C, when compared to the original ASHP. The COP of the TEHP is relatively constant, ranging from 1.63 to 1.76. This prototype offers a solution to address the challenges associated with reduced heat pump capacity at low ambient temperatures. The experimental results indicated that the lower the ambient temperature, thermoelectric heat pump auxiliary heating can increase the heating efficiency 60% in comparison to electric resistance.

42 ENGINEERING↗

Experimental Investigation on Cooling performance of A Thermoelectric Freezer

Thermoelectric heat pumps (TEHPs) have found widespread use in the electronics cooling industry and portable refrigerators. However, there has been a lack of extensive research on the application of TEHPs in low-temperature refrigeration settings. To address this gap, various configurations of TEHPs were fabricated to assess their suitability for freezer applications. Key parameters such as cooling capacity and system performance of the TEHPs were crucial in evaluating these configurations. Three configurations, each with different numbers of cooling units and fan arrangements, were tested using a 300-liter freezer prototype under typical room conditions (21°C). A cooling unit is comprised of two-stage thermoelectric modules, an aluminum plate fin heat exchanger sink with fans positioned either on top or directing airflow through the center, and a cooling block with circulating icy water for heat dissipation. Across all configurations, the minimum temperature inside the freezer cabinet reached -16.0°C. The cooling capacity peaked at 74.7 W, with the thermoelectric coefficient of performance (COP) reaching a maximum of 0.45. System COP ranged from 0.23 to 0.28. Minimum TE power consumption was recorded at 138.8 W, with TE system power consumption at 174.4 W, indicating feasibility for practical residential freezer applications. This investigation lays the foundation for integrating TE freezers with ice thermal storage systems.

Hu, Yifeng↗

Technology Development and Field Monitoring in nZEB - US Country report IEA HPT Annex 49 Task 3

The International Energy Agency (IEA) Heat Pumping Technologies (HPT) Annex 49, “Design and Integration of Heat Pumps for Nearly Zero Energy Buildings,” deals with the application of heat pumps (HPs) as a core component of the HVAC system for nearly or net-zero energy buildings. This report covers the Task 3 activities of the US team. Three institutions are involved on the US team and have worked on the following projects. 1) Oak Ridge National Laboratory (ORNL) summarized development activities since the conclusion of IEA HPT Annex 40 for several integrated HP (IHP) systems - electric ground-source IHP and air-source IHP versions and engine-driven AS-IHP version. 2) The University of Maryland partnered with ORNL and Blue Bear Management to develop a personal cooling device called RoCo that can provide personalized conditioned air to occupants in inadequately or unconditioned environments. With RoCo, building facility management can elevate the HVAC thermostat settings without compromising occupants’ thermal comfort. Researchers have found that a 4°F increase in thermostat settings can save 12–30% energy savings. Therefore, RoCo is a promising technology that can help reduce building energy consumption and facilitate achievement of net-zero energy building performance. 3) The National Institute of Standards and Technology (NIST) is working on a field study effort on the NIST Net-Zero Energy Residential Test Facility. Two air-source split-system HPs were installed in a residential, net-zero energy home that was constructed as a laboratory on the NIST campus in Gaithersburg, Maryland. The first HP was a two-stage, 7 kW (2 ton), 15.8 seasonal energy efficiency ratio (SEER), 9.05 heating seasonal performance factor (HSPF) conventionally ducted system; the second HP was a variable-speed, 10.6 kW (3 ton), 14 SEER, 8.35 HSPF, high-velocity ducted system. These two systems operated side by side, using separate supply ducts and a common return duct, on a weekly alternating schedule to condition the home that was operated with very consistent simulated thermal loads. The team wanted to determine whether the high-velocity system could provide comparable energy-use efficiency to the conventional system. The results of this study showed that it did meet the required loads and had slightly greater efficiency; the average cooling coefficient of performance (COP) was (0.40 ± 0.11) higher, and the average heating COP was statistically equal. A new firmware was provided at the end of the heating season that greatly improved the performance of the high-velocity system; its average heating COP went from (1.8 ± 0.9) to (2.5 ± 1.1) at a 95% confidence level. The new firmware heating COP averaged (1.05 ± 0.23) higher than the old firmware over the same outdoor temperatures. The defrost performance is very different for these two systems, yet they consumed equivalent energy per HDD. The conventional system uses a timed-initiate, temperature-terminate algorithm with auxiliary electric resistive heating, whereas the high-velocity system uses calculated evaporator parameters with a hot-gas bypass before a full reverse-cycle defrost with no supplementary resistive heat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lunar base heat pump, phase 1

This report describes the Phase 1 process and analysis used to select a refrigerant and thermodynamic cycle as the basis of a vapor compression heat pump requiring a high temperature lift, then to perform a preliminary design to implement the selected concept, including major component selection. Use of a vapor compression heat pump versus other types was based on prior work performed for the Electric Power Research Institute. A high lift heat pump is needed to enable a thermal control system to remove heat down to 275 K from a habitable volume when the external thermal environment is severe. For example, a long-term lunar base habitat will reject heat from a space radiator to a 325 K environment. The first step in the selection process was to perform an optimization trade study, quantifying the effect of radiator operating temperature and heat pump efficiency on total system mass; then, select the radiator operating temperature corresponding to the lowest system mass. Total system mass included radiators, all heat pump components, and the power supply system. The study showed that lunar night operation, with no temperature lift, dictated the radiator size. To operate otherwise would require a high mass penalty to store power. With the defined radiation surface, and heat pump performances assumed to be from 40 percent to 60 percent of the Carnot ideal, the optimum heat rejection temperature ranged from 387 K to 377 K, as a function of heat pump performance. Refrigerant and thermodynamic cycles were then selected to best meet the previously determined design conditions. The system was then adapted as a ground-based prototype lifting temperature to 360 K (versus 385 K for flight unit) and using readily available commercial-grade components. Over 40 refrigerants, separated into wet and dry compression behavioral types, were considered in the selection process. Refrigerants were initially screened for acceptable critical temperature. The acceptable refrigerants were analyzed in ideal single and two-stage thermodynamic cycles. Top candidates were analyzed assuming realistic component limits and system pressure drops, and were evaluated for other considerations such as safety, environmental impact, and commercial availability. A maximum coefficient of performance (COP) of 56 percent of the Carnot ideal was achievable for a three-stage CFC-11 cycle operating under the flight conditions above. The program was completed by defining a control scheme and by researching and selecting the major components, compressor and heat exchangers, that could be used to implement the thermodynamic cycle selected. Special attention was paid to using similar technologies for the SIRF and flight heat pumps resulting in the commercially available equivalent of the flight unit. A package concept was generated for the components selected and mass and volume estimated.

Goldman, Jeffrey H.↗

Field Validation of Air-Source Heat Pumps for Cold Climates

Heating energy is the largest end-use for U.S. residential buildings accounting for approximately one-third of residential building energy consumption (EIA 2021). Historically, air-source heat pumps have been limited to temperate climates because of subpar performance at extremely cold outdoor air temperatures. However, recent advances to cold-climate air-source heat pump technology, which typically rely on inverter-driven, variable-speed compressors and variable-speed fans, have significantly improved low-temperature heat pump performance enabling the technology to save energy for many homes in cold climates. The primary objective of this project was to measure in-field performance of centrally ducted, variable-capacity air-source heat pumps in cold climates to validate performance and develop field-based performance maps. The project focused on quantifying heat pump performance at cold temperatures. The sites identified for the study were primarily located in the Northwest United States since homes in the region tend to have all-electric space heating systems and high-efficiency heat pumps have been incentivized in the region for several years. NREL partnered with Ecotope, Inc., a small energy consulting firm located in Seattle, WA, for site recruitment, monitoring equipment installation, data quality management. All the sites included in the study had previously installed a high-efficiency, central heat pump system. One site was in a Denver, CO suburb, which was the only dual fuel heat pump in the study. We used airside and power measurements, collected at 5-second intervals, to quantify heat pump capacity, coefficient of performance (COP), and auxiliary heater energy consumption. We developed algorithms to automatically determine the heat pump operating mode including defrost and auxiliary heating operation. A whole-house thermal and duct audit was completed during the initial site visit to estimate winter heating loads and assess heat pump sizing. Whole-home heating design loads were calculated at ASHRAE 99% design temperatures and compared to manufacturer-reported maximum capacities to assess the heat pump sizing at each site.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Decarbonization of Residential Building Energy Supply: Impact of Cogeneration System Performance on Energy, Environment, and Economics

Electrical and thermal loads of residential buildings present a unique opportunity for onsite power generation, and concomitant thermal energy generation, storage, and utilization, to decrease primary energy consumption and carbon dioxide intensity. This approach also improves resiliency and ability to address peak load burden effectively. Demand response programs and grid-interactive buildings are also essential to meet the energy needs of the 21st century while addressing climate impact. Given the significance of the scale of building energy consumption, this study investigates how cogeneration systems influence the primary energy consumption and carbon footprint in residential buildings. The impact of onsite power generation capacity, its electrical and thermal efficiency, and its cost, on total primary energy consumption, equivalent carbon dioxide emissions, operating expenditure, and, most importantly, thermal and electrical energy balance, is presented. The conditions at which a cogeneration approach loses its advantage as an energy efficient residential resource are identified as a function of electrical grid’s carbon footprint and primary energy efficiency. Compared to a heat pump heating system with a coefficient of performance (COP) of three, a 0.5 kW cogeneration system with 40% electrical efficiency is shown to lose its environmental benefit if the electrical grid’s carbon dioxide intensity falls below 0.4 kg CO 2 per kWh electricity.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of Periodic Unsteadiness on Performance and Heat Load in Axial Flow Turbomachines

Results of an analytical and experimental investigation, directed at the understanding of the impact of periodic unsteadiness on the time-averaged flows in axial flow turbomachines, are presented. Analysis of available experimental data, from a large-scale rotating rig (LSRR) (low speed rig), shows that in the time-averaged axisymmetric equations the magnitude of the terms representing the effect of periodic unsteadiness (deterministic stresses) are as large or larger than those due to random unsteadiness (turbulence). Numerical experiments, conducted to highlight physical mechanisms associated with the migration of combustor generated hot-streaks in turbine rotors, indicated that the effect can be simulated by accounting for deterministic stress like terms in the time-averaged mass and energy conservation equations. The experimental portion of this program shows that the aerodynamic loss for the second stator in a 1-1/2 stage turbine are influenced by the axial spacing between the second stator leading edge and the rotor trailing edge. However, the axial spacing has little impact on the heat transfer coefficient. These performance changes are believed to be associated with the change in deterministic stress at the inlet to the second stator. Data were also acquired to quantify the impact of indexing the first stator relative to the second stator. For the range of parameters examined, this effect was found to be of the same order as the effect of axial spacing.

Sharma, Om P.↗

Experimental characterization of a triply periodic minimal surface PCM-to-air thermal energy storage device

Here, the expansion of energy production has intensified research into thermal energy storage (TES) to manage variability and improve system efficiency. Heat exchanger design is critical to achieving high power densities in TES systems. This study presents a high-surface-area phase change material (PCM)-to-air heat exchanger fabricated via resin-based stereolithography with a novel gyroid-based geometry tailored for enhanced performance. Material properties of the commercial PCM and resin were characterized using analytical techniques. A controlled air loop was used to evaluate heat transfer and pressure drop at various flow rates and inlet temperatures. Results show a strong dependence on the inlet temperature difference (ΔT) relative to the PCM melting point. During charging at the highest flow rate, increasing the inlet air temperature from ΔT = 5 °C to 20 °C above the melting point increased the average heat transfer rate by 187%. During discharging, decreasing the inlet temperature by the same ΔT below the melting point led to a 232% increase. Notably, the high-surface-area design enabled nearly symmetric charging and discharging behavior, a novel result for PCM-based TES systems which are often restricted by natural convection and other effects. The overall heat transfer coefficient was calculated and compared to values from standard design correlations. The maximum thermal effectiveness reached 95% at ΔT = 20 °C and a moderate flow rate of 34 m 3 /h. Peak coefficients of performance (COP) of 7 during charging and 6.4 during discharging were observed at ΔT = 20 °C and a low flow rate of 20 m 3 /h. These results demonstrate the viability of additively manufactured geometries for advanced TES applications.

25 ENERGY STORAGE↗

Energy characteristics of multi-chiller load distribution algorithms in a large office building

Here, this study evaluates the energy efficiency of multi-chiller systems in large office buildings, focusing on their optimization across various climate zones as defined by ASHRAE. Using EnergyPlus for simulations, the research examines five different load distribution algorithms in multi-chiller systems that range from one to ten chillers, aiming to understand their effectiveness in 15 distinct climate zones. The primary objectives of the study include identifying the energy efficiency of multi-chiller systems in each climate zone, determining the appropriate number of chillers for each zone, and evaluating the performance of the load distribution algorithms. Based on the U.S. Department of Energy’s commercial building model, the results suggest that multi-chiller systems can significantly reduce cooling energy consumption in various climates. Among the algorithms evaluated, the Sequential Uniform Part Load Ratio (SUPLR) algorithm demonstrates notable efficiency, especially in the 4A climate zone (Baltimore), where it achieves substantial energy savings. Applying the SUPLR algorithm in a multi-chiller setup with four chillers in this zone leads to an estimated 24.5 % reduction in energy usage, equivalent to 183 MW annually. The research indicates that a range of 3 to 5 chillers is typically optimal for most climate zones. In-depth analysis in the 4A climate zone highlights the importance of minimizing operation hours at low Part Load Ratios (PLR) to ensure that chillers operate at a high Coefficient of Performance (COP). This strategy underscores the potential of well-designed multi-chiller systems to reduce cooling energy demand, particularly in climates with transitional seasons. This study provides an overview of the energy-saving potential of multi-chiller systems, applicable across a variety of climatic scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗