Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Clocks”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Progress on Small Mercury Ion Clock for Space Applications

We have recently completed a breadboard ion-clock physics package based on Hg ions shuttled between a quadrupole and a 16-pole rf trap. With this architecture we have demonstrated short-term stability approx.1-2x10-(sup 1)(sup 3) at 1 second, averaging to 10-(sup 1)? at 1 day. This development shows that H-maser quality stabilities can be produced in a small clock package, comparable in size to an ultra-stable quartz oscillator required for holding 1-2x10-(sup 1)(sup 3) at 1 second. This performance was obtained in a sealed vacuum configuration where only a getter pump was used to maintain vacuum. The vacuum tube containing the traps has now been under sealed vacuum conditions for over three years with no measurable degradation of ion trapping lifetimes or clock short-term performance. We have fabricated the vacuum tube, ion trap and UV windows from materials that will allow approx. 400 deg C bake-out to prepare for tube seal-off. This approach to the vacuum follows the methods used in flight vacuum tube electronics, such as flight TWTA's where tube operation lifetime and shelf life of up to 15 years is achieved.

positioning

Compact Microwave Mercury Ion Clock for Space Applications

We have recently completed a breadboard ion-clock physics package based on Hg ions shuttled between a quadrupole and a 16-pole rf trap. With this architecture we have demonstrated short-term stability approximately 1 - 2 x 10(exp -13) at 1 second, averaging to 10(exp -15) at 1 day. This development shows that H-maser quality stabilities can be produced in a small clock package, comparable in size to an ultra-stable quartz oscillator required for holding 1 - 2 x 10(exp -13) at 1 second. This performance was obtained in a sealed vacuum configuration where only a getter pump was used to maintain vacuum. The vacuum tube containing the traps has now been under sealed vacuum conditions for nearly three years with no measurable degradation of ion trapping lifetimes or clock short-term performance. We have fabricated the vacuum tube, ion trap and UV windows from materials that will allow an approximately 400 C bake-out to prepare for tube seal-off. This approach to the vacuum follows the methods used in flight vacuum tube electronics, such as flight TWTA's where tube operation lifetime and shelf life of up to 15 years is achieved.

Atomic Clock

A Novel Photonic Clock and Carrier Recovery Device

In high-speed fiber-optic communications systems, the ability to recover the clock from the incoming random data is essential. The recovered clock must be in precise synchronism with the incoming data and is used in further signal processing systems, such as regenerative repeaters, time division switching systems, and demultiplexers. A high-speed photonic clock regenerator is described.

photonic

Clock Synchronization Characterization of the Washington DC Metropolitan Area Quantum Network (DC-QNet)

Quantum networking protocols relying on interference and precise time-of-flight measurements require high-precision clock synchronization. This study describes the design, implementation, and characterization of two optical time transfer methods in a metropolitan-scale quantum networking research testbed. With active electronic stabilization, sub-picosecond time deviation (TDEV) was achieved at integration times between 1 s and 10 5 s over 53 km of deployed fiber. Over the same integration periods, 10-picosecond level TDEV was observed using the White Rabbit-Precision Time Protocol (WR-PTP) over 128 km. Measurement methods are described to understand the sources of environmental fluctuations on clock synchronization towards the development of in-situ compensation methods. Path delay gradients, chromatic dispersion, polarization drift, and optical power variations all contributed to clock synchronization errors. The results from this study will inform future work in the development of link noise management methods essential for enabling experimental research in developing practical quantum networking protocols.

PIKTime

Compact Microwave Mercury Ion Clock for Deep-Space Applications

We have recently completed a breadboard ion-dock physics package based on Kg ions shuttled between a quadrupole and a 16-pole rf trap. With this architecture we have demonstrated short-term stability -1-2xl0-13 at 1 second, averaging to 10-15 at 1 day. This development shows that 8- maser quality stabilities can be produced in a small clock package, comparable in size to an oItra-stable quartz oscillator required for holding 1-2xl0-13 at 1 second. This performance was obtained in a sealed vacuum configuration where only agetter pump was used to maintain vacuum. The vacuum tube containing the traps has now been onder sealed vacuum conditions for nearly two years with no measurable degradation of ion trapping lifetimes or clock short-term performance. We have fabricated the vacuum tube, ion trap and UV windows from materials that will allow a - 400 C tube bake-out to prepare for tube sealoff. This approach to the vacuum follows the methods used in mght vacuum tube electronics, such as flight TWTA's where tube operation lifetime and shelf life of up to 15 years is achieved. We use neon as a buffer gas with 2-3 times less pressure induced frequency pulling than helium and, being heavier, negligable diffusion losses will occur over the operation lifetime.

space clock

Quantum-amplified global-phase spectroscopy on an optical clock transition

Optical lattice clocks are at the forefront of precision metrology, operating near a standard quantum limit set by quantum noise. Harnessing quantum entanglement offers a promising route to surpass this limit; however, there are practical difficulties in terms of scalability and measurement resolution requirements. Here we adapt the holonomic quantum gate concept to develop a new Rabi-type ‘global-phase spectroscopy’ that uses the detuning-sensitive global Aharonov–Anandan phase19. With this approach, we can demonstrate quantum-amplified time-reversal spectroscopy on an optical clock transition that achieves directly measured 2.4(7) dB metrological gain and 4.0(8) dB improvement in laser noise sensitivity beyond the standard quantum limit. To this end, we introduce rotary echo to protect the dynamics from inhomogeneities in light–atom coupling and implement a laser-noise-cancelling differential measurement through symmetric phase encoding in two nuclear spin states. Our technique is not limited by measurement resolution, scales easily because of the global nature of entangling interaction and exhibits high resilience to typical experimental imperfections. As a result, we expect it to be broadly applicable to next-generation atomic clocks and other quantum sensors approaching the fundamental quantum precision limits.

Zaporski, Leon [Massachusetts Institute of Technol

Probing Curved Spacetime with a Distributed Atomic Processor Clock

Quantum dynamics on curved spacetime has never been directly probed beyond the Newtonian limit. Although we can describe such dynamics theoretically, experiments would provide empirical evidence that quantum theory holds even in this extreme limit. The practical challenge is the minute spacetime curvature difference over the length scale of the typical extent of quantum effects. Here, we propose a quantum network of alkaline earth (like) atomic processors for constructing a distributed quantum state that is sensitive to the differential proper time between its constituent atomic processor nodes, implementing a quantum observable that is affected by post-Newtonian curved spacetime. Conceptually, we propose to delocalize one clock between three locations by encoding the presence or absence of a clock into the state of the local atoms. By separating three atomic nodes over approximately kilometer-scale elevation differences and distributing one clock between them via a 𝑊 state, we demonstrate that the curvature of spacetime is manifest in the interference of the three different proper times that give rise to three distinct beat notes in our nonlocal observable. We further demonstrate that 𝑁-atom entanglement within each node enhances the interrogation bandwidth by a factor of 𝑁. We discuss how our proposed system can probe new facets of fundamental physics, such as the linearity, unitarity, and probabilistic nature of quantum theory on curved spacetime. Our protocol combines several recent advances with neutral atom and trapped ions to realize a novel quantum probe of gravity uniquely enabled by quantum networks.

Covey, Jacob P. [Univ. of Illinois at Urbana-Champ

Cumulative fidelity of large-momentum-transfer clock atom interferometers in the presence of laser noise

Clock atom interferometry is an emerging technique in precision measurements that is particularly well suited for sensitivity enhancement through large momentum transfer (LMT). While current systems have demonstrated momentum separations of several hundreds of photon momenta, next-generation quantum sensors are targeting an LMT enhancement factor beyond 10 4 . However, the viability of LMT clock interferometers has recently come into question due to the potential impact of laser frequency noise. Here, in this work, we resolve this concern by analyzing the cumulative fidelity of sequential state inversions in an LMT atom interferometer. We show that the population error from 𝑛 pulses applied from alternating directions scales linearly with 𝑛. This is a significant advantage over the 𝑛 2 scaling that occurs when probing a two-level system 𝑛 times from the same direction. We further show that contributions to the interferometer signal from parasitic paths generated by imperfect pulses are negligible, for any loss mechanism. These results establish that laser frequency noise is not a practical limitation for the development of high-fidelity LMT clock atom interferometers.

Mach-Zehnder atom interferometry

VLBI clock synchronization tests performed via the ATS-1 and ATS-3 satellites

Clock synchronization experiments were carried out May 10 to June 10, 1971, by the NASA/Goddard Space Flight Center and the Smithsonian Astrophysical Observatory via the ATS-1 and 3 geostationary satellites at the NASA tracking stations Rosman and Mojave, during a VLBI (Very Long Baseline Interferometer) experiment in order to determine the clock-offset between the two stations. Ten microsecond pulses at C-band with very sharp risetime were exchanged by the two stations through the dual transponders of the satellites. At each station, a time-interval counter was started by the transmitted pulse and stopped by the received pulse. The probable error of the difference in the mean values of the clock-offset is 10 nanoseconds.

Ramasastry, J.

Quasars as very-accurate clock synchronizers

Quasars can be employed to synchronize global data communications, geophysical measurements, and atomic clocks. It is potentially two to three orders of magnitude better than presently-used Moon-bounce system. Comparisons between quasar and clock pulses are used to develop correction or synchronization factors for station clocks.

Hurd, W. J.

VLBI clock sync and the earth's rotational instability

Preparation is being made by the DSN to monitor the stability of its clocks and frequency standards in the 64 meter net by means of VLBI. Since variations in the earth's rotation rate represent an error source to VLBI clock synchronization, the Allan Variance of the earth rotation was calculated to find that, in a long-term sense at least, these variations do not noticeably increase the differential instability of two clocks as measured by Intercontinental VLBI.

Layland, A. W.

Application of satellite time transfer in autonomous spacecraft clocks

The conceptual design of a spacecraft clock that will provide a standard time scale for experimenters in future spacecraft., and can be sychronized to a time scale without the need for additional calibration and validation is described. The time distribution to the users is handled through onboard computers, without human intervention for extended periods. A group parallel binary code, under consideration for onboard use, is discussed. Each group in the code can easily be truncated. The autonomously operated clock not only achieves simpler procedures and shorter lead times for data processing, but also contributes to spacecraft autonomy for onboard navigation and data packetization. The clock can be used to control the sensor in a spacecraft, compare another time signal such as that from the global positioning system, and, if the cost is not a consideration, can be used on the ground in remote sites for timekeeping and control.

Chi, A. R.

Navstar Global Positioning System (GPS) clock program: Present and future

Global Positioning System (GPS) program status are discussed and plans for ensuring the long term continuation of the program are presented. Performance of GPS clocks is presented in terms of on orbit data as portrayed by GPS master control station kalman filter processing. The GPS Clock reliability program is reviewed in depth and future plans fo the overall clock program are published.

Tennant, D. M.

Comparison of VLBI, TV and traveling clock techniques for time transfer

A three part experiment was conducted to develop and compare time transfer techniques. The experiment consisted of (1) a very long baseline interferometer (VLBI), (2) a high precision portable clock time transfer system between the two sites, and (3) a television time transfer. A comparison of the VLBI and traveling clock shows each technique can perform satisfactorily at the five nsec level. There was a systematic offset of 59 nsec between the two methods, which we attributed to a difference in epochs between VLBI formatter and station clock. The VLBI method had an internal random error of one nsec at the three sigma level for a two day period. Thus, the Mark II system performed well, and VLBI shows promise of being an accurate method of time transfer. The TV system, which had technical problems during the experiment, transferred time with a random error of about 50 nsec.

Spencer, J. H.

Elemental technetium as a cosmic-ray clock

Several radioactive isotopes have been proposed as clocks for the study of the mean cosmic ray confinement time, T sub e. Measurements of Be-10 and Al-26 give a value for T sub e of about 10 Myr when one uses a leaky box cosmic ray propagation model. It is important to obtain additional measurements of T sub e from other radioactive isotopes in order to check whether the confinement is the same throughout the periodic table. The possible use of Tc (Z = 43) as a cosmic clock is investigated. Since all isotopes of Tc are radioactive, one might be able to group these isotopes and use the elemental abundance as a whole. The results of the calculations are somewhat inconclusive for two reasons. First, the beta + decay half lives of two of the Tc isotopes relevant to our calculation are not known. Second, the dependence of the Tc abundance on the mean confinement time is rather weak when one considers the number of events expected in 4 trays of plastic track detectors. However, a future, finite measurement of the Beta + half lives and the possible use of the entire collecting area of the HNC to detect Tc nuclei could make the use of Tc as a cosmic ray clock more attractive.

Drach, J.

Fault-tolerant clock synchronization validation methodology

A validation method for the synchronization subsystem of a fault-tolerant computer system is presented. The high reliability requirement of flight-crucial systems precludes the use of most traditional validation methods. The method presented utilizes formal design proof to uncover design and coding errors and experimentation to validate the assumptions of the design proof. The experimental method is described and illustrated by validating the clock synchronization system of the Software Implemented Fault Tolerance computer. The design proof of the algorithm includes a theorem that defines the maximum skew between any two nonfaulty clocks in the system in terms of specific system parameters. Most of these parameters are deterministic. One crucial parameter is the upper bound on the clock read error, which is stochastic. The probability that this upper bound is exceeded is calculated from data obtained by the measurement of system parameters. This probability is then included in a detailed reliability analysis of the system.

Computer systems

Transmission delays in hardware clock synchronization

Various methods, both with software and hardware, have been proposed to synchronize a set of physical clocks in a system. Software methods are very flexible and economical but suffer an excessive time overhead, whereas hardware methods require no time overhead but are unable to handle transmission delays in clock signals. The effects of nonzero transmission delays in synchronization have been studied extensively in the communication area in the absence of malicious or Byzantine faults. The authors show that it is easy to incorporate the ideas from the communication area into the existing hardware clock synchronization algorithms to take into account the presence of both malicious faults and nonzero transmission delays.

Shin, Kang G.

Slot clock recovery in optical PPM communication systems with avalanche photodiode photodetectors

Slot timing recovery in a direct-detection optical PPM communication system can be achieved by processing the photodetector output waveform with a nonlinear device whose output forms the input to a phase-locked loop. The choice of a simple transition detector as the nonlinearity is shown to give satisfactory synchronization performance. The rms phase error of the recovered slot clock and the effect of slot timing jitter on the bit error probability were directly measured. The experimental system consisted of an AlGaAs laser diode (wavelength = 834 nm) and a silicon avalanche photodiode photodetector. The system used Q = 4 PPM signaling and operated at a source data rate of 25 Mbits/s. The mathematical model developed to compute the rms phase error of the recovered clock is shown to be in good agreement with results of actual measurements of phase errors. The use of the recovered slot clock in the receiver resulted in no significant degradation in receiver sensitivity compared to a system with perfect slot timing. The system achieved a bit error probability of 10 to the -6th at a received optical signal energy of 55 detected photons per information bit.

Davidson, Frederic M.