At least 127 records · Page 7

Enhanced capacity and stability for the separation of cesium in electrically switched ion exchange

Electrically switched ion exchange (ESIX) can be used to separate ionic contaminants from industrial wastewater, including that generated by the nuclear industry. The ESIX method involves sequential application of reduction and oxidation potentials to an ion exchange film to induce the respective loading and unloading of cesium. This technology is superior to conventional methods (e.g electrodialysis reversal or reverse osmosis) as it requires very little energy for ionic separation. In previous studies, ESIX films have demonstrated relatively low ion exchange capacities and limited film stabilities over repeated potential applications. In this study, the methodology for the deposition of electro-active films (nickel hexacyanoferrate) on nickel electrodes was modified to improve the ion exchange capacity for cesium removal using ESIX. Cyclic voltammetry was used to investigate the ion exchange capacity and stability. Scanning electron microscopy (SEM) was used to characterize the modified film surfaces. Additionally, the films were examined for the separation of cesium ions. This modified film preparation technique enhanced the ion exchange capacity and improves the film stability compared to previous methods for the deposition of ESIX films. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SELECTIVE REMOVAL OF STRONTIUM AND CESIUM FROM SIMULATED WASTE SOLUTION WITH TITANATE ION EXCHANGERS IN A FILTER CARTRIDGE CONFIGURATION

This report describes experimental results for the selective removal of strontium and cesium from simulated waste solutions using monosodium titanate (MST) and crystalline silicotitanate (CST)-laden filter cartridges. Four types of ion exchange cartridge media (CST and MST designed by both 3M and POROX{reg_sign}) were evaluated. In these proof-of-principle tests effective uptake of both Sr-85 and Cs-137 was observed. However, the experiments were not performed long enough to determine the saturation levels or breakthrough curve for each filter cartridge. POREX{reg_sign} MST cartridges, which by design were based on co-sintering of the active titanates with polyethylene particles, seem to perform as well as the 3M-designed MST cartridges (impregnated filter membrane design) in the uptake of strontium. At low salt simulant conditions (0.29 M Na{sup +}), the instantaneous decontamination factor (D{sub F}) for Sr-85 with the 3M-design MST cartridge measured 26, representing the removal of 96% of the Sr-85. On the other hand, the Sr-85 instantaneous D{sub F} with the POREX{reg_sign} design MST cartridge measured 40 or 98% removal of the Sr-85. Strontium removal with the 3M-design MST and CST cartridges placed in series filter arrangement produced an instantaneous decontamination factor of 41 or 97.6% removal compared to an instantaneous decontamination factor of 368 or 99.7% removal of the strontium with the POREX{reg_sign} MST and CST cartridge design placed in series. At high salt simulant conditions (5.6 M Na{sup +}), strontium removal with 3M-designed MST cartridge only and with 3M-designed MST and CST cartridges operated in a series configuration were identical. The instantaneous decontamination factor and the strontium removal efficiency, under the above configuration, averaged 8.6 and 88%, respectively. There were no POREX{reg_sign} cartridge experiments using the higher ionic strength simulant solution. At low salt simulant conditions, the uptake of Cs-137 with POREX{reg_sign} CST cartridge out performed the 3M-designed CST cartridges. The POREX{reg_sign} CST cartridge, with a Cs-137 instantaneous decontamination factor of 55 and a Cs-137 removal efficiency of 98% does meet the Cs-137 decontamination goals in the low salt simulant liquor. The Cs-137 removal with 3M-designed CST cartridge produced a decontamination factor of 2 or 49% removal efficiency. The Cs-137 performance graph for the 3M-designed CST cartridge showed an early cessation in the uptake of cesium-137. This behavior was not observed with the POREX{reg_sign} CST cartridges. No Cs-137 uptake tests were performed with the POREX{reg_sign} CST cartridges at high salt simulant conditions. The 3M-designed CST cartridges, with an instantaneous Cs-137 decontamination factor of less than 3 and a Cs-137 removal efficiency of less than 50% failed to meet the Cs-137 decontamination goals in both the low and high salt simulant liquors. This poor performance in the uptake of Cs-137 by the 3M CST cartridges may be attributed to fabrication flaws for the 3M-designed CST cartridges. The reduced number of CST membrane wraps per cartridge during the cartridge design phase, from 3-whole wraps to about 1.5, may have contributed to Cs-137 laden simulant channeling/by-pass which led to the poor performance in terms of Cs-137 sorption characteristics for the 3M designed CST cartridges. The grinding of CST ion exchange materials, to reduce the particle size distribution and thus enhance their easy incorporation into the filter membranes and the co-sintering of MST with polyethylene particles, did not adversely affect the sorption kinetics of both CST and MST in the uptake of Cs-137 and Sr-85, respectively. In general, the POREX{reg_sign} based cartridges showed more resistance to simulant flow through the filter cartridges as evidenced by higher pressure differences across the cartridges. Based on these findings they conclude that incorporating MST and CST sorbents into filter membranes represent a promising method for the semi-continuous removal of radioisotopes of strontium and cesium from waste solutions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

MODELING RESULTS FROM CESIUM ION EXCHANGE PROCESSING WITH SPHERICAL RESINS

Ion exchange modeling was conducted at the Savannah River National Laboratory to compare the performance of two organic resins in support of Small Column Ion Exchange (SCIX). In-tank ion exchange (IX) columns are being considered for cesium removal at Hanford and the Savannah River Site (SRS). The spherical forms of resorcinol formaldehyde ion exchange resin (sRF) as well as a hypothetical spherical SuperLig{reg_sign} 644 (SL644) are evaluated for decontamination of dissolved saltcake wastes (supernates). Both SuperLig{reg_sign} and resorcinol formaldehyde resin beds can exhibit hydraulic problems in their granular (nonspherical) forms. SRS waste is generally lower in potassium and organic components than Hanford waste. Using VERSE-LC Version 7.8 along with the cesium Freundlich/Langmuir isotherms to simulate the waste decontamination in ion exchange columns, spherical SL644 was found to reduce column cycling by 50% for high-potassium supernates, but sRF performed equally well for the lowest-potassium feeds. Reduced cycling results in reduction of nitric acid (resin elution) and sodium addition (resin regeneration), therefore, significantly reducing life-cycle operational costs. These findings motivate the development of a spherical form of SL644. This work demonstrates the versatility of the ion exchange modeling to study the effects of resin characteristics on processing cycles, rates, and cold chemical consumption. The value of a resin with increased selectivity for cesium over potassium can be assessed for further development.

36 MATERIALS SCIENCE↗

Immobilization of Cesium Traps from the BN-350 Fast Reactor (Aktau, Kazakhstan)

During BN-350 reactor operations and also during the initial stages of decommissioning, cesium traps were used to decontaminate the reactor’s primary sodium coolant. Two different types of carbon-based trap were used – the MAVR series, low ash granulated graphite adsorber (LAG) contained in a carrier designed to be inserted into the reactor core during shutdown; and a series of ex-reactor trap accumulators(TAs) which used reticulated vitreous carbon (RVC) to reduce Cs-137 levels in the sodium after final reactor shutdown. In total four MAVRs and seven TAs were used at BN-350 to remove an estimated cumulative 755 TBq of cesium. The traps, which also contain residual sodium, need to be immobilized in an appropriate way to allow them to be consigned as waste packages for long term storage and, ultimately, disposal. The present paper reports on the current status of the implementation phase, with particular reference to the work done to date on the trap accumulators, which have the most similarity with the cesium traps used at other reactors.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cesium Isotope Ratios as Indicators of Nuclear Power Plant Operations

There are multiple paths by which radioactive cesium can reach the effluent from reactor operations. The radioactive 135Cs/137Cs ratios are controlled by these paths. In an effort to better understand the origin of this radiation, these 135Cs/137Cs ratios in effluents from three power reactor sites have been measured in offsite samples. These ratios are different from global fallout by up to six fold and as such cannot have a significant component from this source. A cesium ratio for a sample collected outside of the plant boundary provides integration over the operating life of the reactor. A sample collected inside the plant at any given time can be much different from this lifetime ratio. The measured cesium ratios vary significantly for the three reactors and indicate that the multiple paths have widely varying levels of contributions. There are too many ways these isotopes can fractionate to be useful for quantitative evaluations of operating parameters in an offsite sample, although it may be possible to obtain limited qualitative information for an onsite sample.

137Cs↗

Tank Side Cesium Removal System Project and Technology Maturation Program - 19519

Washington River Protection Solutions (WRPS) is the Tank Operating Contractor (TOC) for the U.S. Department of Energy-Office of River Protection (DOE-ORP) on the Hanford Site. The Hanford Site stores an estimated 56 million gallons of mixed radioactive and chemically hazardous waste in large underground tanks. WRPS is in the process of designing the Tank Side Cesium Removal (TSCR) system to produce Low Activity Waste (LAW) from Hanford tank waste. The LAW will be transferred to the Waste Treatment and Immobilization Plant (WTP) LAW Vitrification Facility, where the hazardous constituents in the LAW will be immobilized in a durable glass waste form for disposal. The TSCR Project demonstrates a tank-side treatment system for providing feed to the WTP LAW Vitrification Facility. This system removes cesium from supernatant tank waste using non-elutable cesium ion exchange media to meet the applicable waste acceptance criteria for the WTP. In support of the project, a tailored Technology Maturation/Testing Plan (TMP) has been developed to identify principal Technology Elements (TEs) for the proposed process, designate Critical Technology Elements (CTEs), identify gaps in the existing knowledge base and identify the necessary activities to mature the technologies for successful deployment of TSCR. The project scope and technology maturation approach are presented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Qualification of Processing Batches for Tank Closure Cesium Removal Through In-Tank Batch Contact Testing - 20470

The Tank Closure Cesium Removal (TCCR) process at the Savannah River Site (SRS) is currently processing waste from Tank 10H, generating decontaminated salt solution that is sent to Tank 11H. Transfers out of Tank 11H are then disposed of on site as a grout wasteform in the SRS Saltstone Processing Facility. This is a full-scale demonstration of the use of Crystalline Silicotitanate (CST) for the decontamination of aqueous nuclear waste supernate. CST primarily removes cesium from the high sodium alkaline feed, but also adsorbs strontium, actinides, and some other trace metals. The TCCR unit is an at-tank set of four ion exchange columns, with two typically being operated in series during waste processing. Tank 10H is serving a dual function as both the salt dissolution tank as well as the feed tank for the TCCR system. Prior to operation of TCCR, Tank 10H must undergo dissolution campaigns, dissolving the salt cake to form an aqueous salt solution (supernate). After each dissolution campaign, the supernate created must be qualified prior to processing through the TCCR system. Qualification includes detailed characterization of the supernate as well as in-tank batch contact tests to determine the equilibrium loading of Cs-137 on the CST ion exchange media (IONSIV{sup TM} R9120-Ba). In support of the in-tank batch contact testing, Savannah River National Laboratory (SRNL) developed a CST sample holder, also referred to as a 'tea-bag', to hold a measured amount (∼0.1 grams) of pretreated CST between stainless steel screens. The tea-bag fits within a standard stainless steel sample vial that has been modified to allow the flow of supernate to the CST. This sample holder is then immersed in the waste tank allowing free contact between the CST beads and the surrounding liquid, at an effectively infinite liquid-to-solid phase ratio. A pair of tea-bags are deployed in the tank for a period of 10 days for each batch, after which the CST is recovered, digested, and analyzed to determine the loading of cesium isotopes on the CST. This result then supports the TCCR column thermal loading limits for processing as part of the TCCR safety basis. This paper will discuss the design and testing of the CST sample holder, as well as results from the first few batches of waste qualified and subsequently processed through the TCCR system. In addition, results from analyses of Tank 11H samples, showing decontamination of the product will be included. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mechanisms of mechanochemical synthesis of cesium lead halides: pathways toward stabilization of α-CsPbI 3

Cesium lead iodide with cubic perovskite structure (α-CsPbI 3 ) is gaining significant interest in photovoltaic applications due to its excellent absorbance of the visible solar light and other attractive optoelectronic properties. However, the synthesis of stable α-CsPbI 3 poses a significant challenge. Mechanochemical synthesis is emerging as a suitable method for the preparation of cesium lead halides. This work investigates the ball milling-induced synthesis of cesium lead halides perovskite phase using halide mixing or doping approaches. The synthesis in the CsI + PbI 2 , CsBr + PbBr 2 , CsBr + PbI 2 , and CsI + PbI 2 + NdI 3 mixtures and halide exchange reactions in the CsPbBr 3 + 3KI and CsBr + PbBr 2 + 3KI systems are investigated to elucidate the mechanism of this process. Then, CsPb(I 1–x Br x ) 3 and CsPb( 1–y )Nd y I 3 materials with different x and y ratios are prepared, and their stability is probed in the air using light absorption spectroscopy. These results suggest that Nd doping is more efficient in the stabilization of the perovskite structure than partial replacement of iodine with bromine. Microstructure observations reveal the existence of two different product formation mechanisms depending on the mechanical properties of reactants. The results reveal that the milling temperature has a significant impact on the reaction kinetics. Here, the produced particles nucleate and grow at the reactant interface and retard the synthesis reaction by creating a diffusion barrier. Extended milling reduces the product particle size and creates fresh contact between reactants, thus facilitating reaction completion.

36 MATERIALS SCIENCE↗

Cesium heat-pipe thermostat

In this paper the authors report a newly developed Cesium Heat-Pipe Thermostat (Cs HPT) with the operation range of 400 °C to 800 °C. The working medium is cesium (Cs) of 99.98% purity and contains no radioisotope. A Cs filing device is developed which can prevent Cs being in contact with air. The structural material is stainless steel. A 5000 h test has been made to confirm the compatibility between cesium and stainless steel. The Cs HPT has several thermometer wells of 220mm depth with different diameters for different sizes of thermometers. The temperature uniformity of the Cs HPT is 0.06 °C to 0.20 °C. A precise temperature controller is used to ensure the temperature fluctuation within ±0.03 °C. The size of Cs HPT is 380mm×320mm×280mm with foot wheels for easy moving. The thermostat has been successfully used for the calibration of industrial platinum resistance thermometers and thermocouples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High voltage holding in the negative ion sources with cesium deposition

High voltage holding of the large surface-plasma negative ion source with cesium deposition was studied. It was found that heating of ion-optical system electrodes to temperature >100 °C facilitates the source conditioning by high voltage pulses in vacuum and by beam shots. The procedure of electrode conditioning and the data on high-voltage holding in the negative ion source with small cesium seed are described. The mechanism of high voltage holding improvement by depletion of cesium coverage is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic Resonance Frequency Shifts of Spin-Polarized Cesium Atoms in a Cs–Rb Mixture

The interaction of spin-polarized cesium atoms with cesium and rubidium atoms under conditions of optical orientation of atoms is considered. On the basis of data on spin-exchange complex cross sections in the Cs–Cs and Cs–Rb systems, a calculation of a magnetic resonance frequency shift of cesium atoms in a Cs–Rb mixture, as well as comparison of the calculated values of the frequency shift with experimental data, is performed.

74 ATOMIC AND MOLECULAR PHYSICS↗

RESULTS OF CESIUM MASS TRANSFER TESTING FOR NEXT GENERATION SOLVENT WITH HANFORD WASTE SIMULANT AP-101

SRNL has performed an Extraction, Scrub, Strip (ESS) test using the next generation solvent and AP-101 Hanford Waste simulant. The results indicate that the next generation solvent (MG solvent) has adequate extraction behavior even in the face of a massive excess of potassium. The stripping results indicate poorer behavior, but this may be due to inadequate method detection limits. SRNL recommends further testing using hot tank waste or spiked simulant to provide for better detection limits. Furthermore, strong consideration should be given to performing an actual waste, or spiked waste demonstration using the 2cm contactor bank. The Savannah River Site currently utilizes a solvent extraction technology to selectively remove cesium from tank waste at the Multi-Component Solvent Extraction unit (MCU). This solvent consists of four components: the extractant - BoBCalixC6, a modifier - Cs-7B, a suppressor - trioctylamine, and a diluent, Isopar L{trademark}. This solvent has been used to successfully decontaminate over 2 million gallons of tank waste. However, recent work at Oak Ridge National Laboratory (ORNL), Argonne National Laboratory (ANL), and Savannah River National Laboratory (SRNL) has provided a basis to implement an improved solvent blend. This new solvent blend - referred to as Next Generation Solvent (NGS) - is similar to the current solvent, and also contains four components: the extractant - MAXCalix, a modifier - Cs-7B, a suppressor - LIX-79{trademark} guanidine, and a diluent, Isopar L{trademark}. Testing to date has shown that this 'Next Generation' solvent promises to provide far superior cesium removal efficiencies, and furthermore, is theorized to perform adequately even in waste with high potassium concentrations such that it could be used for processing Hanford wastes. SRNL has performed a cesium mass transfer test in to confirm this behavior, using a simulant designed to simulate Hanford AP-101 waste.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Natural Enrichment of Stable Cesium in Weathered Micaceous Materials and Its Implications for 137Cs Sorption.

In this exploratory project, we are testing two interrelated hypotheses about the sorption of Cs within weathered micaceous materials in subsurface regolith materials from the Savannah River Site (SRS) located on the Atlantic Coastal Plain: 1) that stable cesium has become significantly enriched relative to potassium in subsurface micaceous particles as a result of chemical weathering processes; and 2) that the Cs so present is sufficient to be a major factor determining the ability of the subsurface materials to take up and hold 137 Cs. To test these hypotheses, we collected by hand augur soil samples corresponding to soils representative at the SRS: upland regolith (Fuquay series); soils formed on Tobacco Road Sandstone; and, soils formed on Quaternary Alluvium. From our data, the quantification of the amounts of stable cesium concentrated in various sites within 2:1 phyllosilicates by natural processes is highly relevant toward understanding the future sorption of 137 Cs by the mica, illite, vermiculite, and hydroxyl interstratified vermiculite (HIV) phases present in the subsurface at and in proximity to SRS. Studying sorption and fixation of Cs in these micaceous phases interlayers potentially leads to increased knowledge to the extent that stable Cs resists exchange with ion exchange cations (Mg, NH4, or even alkyl ammonium compounds) and to the extent that Cs can become fixed over the long term. Such knowledge will help in the development of 137 Cs remediation strategies for the long-term, which is a critical aspect of the SBR goals. We characterized the mineralogy, K-Ar ages of the soil and soil clay fractions (before and after acid treatment), and alkali element chemistry (K, Rb, Cs) of the clay fractions of soils collected from these three different types of soils. The clay fractions of the Fuquay soils are composed of kaolinite, and hydroxy interstratified vermiculite (HIV). Kaolinite, HIV, quartz, gibbsite and illite are found in the quaternary soils. Leach experiments using 10% nitric acid and 50% nitric acid were performed on 62 mesh fractions to show the amounts of Cs and Rb relative to K (Cs/K, Rb/K) that are exchangeable in these soils compared to Coastal Plain micas and upper continental crust. The Cs/K and Rb/K of the leachates are considerably higher relative to both upper continental crust and relative to weathered micas found in Georgia Coast Plain sediments. The K-Ar ages of the clay fractions of five different SRS soil series were ca. 320 Ma. After leaching with nitric acid, the ages of the soil clay fractions were approximately the same as the unleached soil clays. Based on the similarity of these ages to the ages of Coastal Plain micas, the K and Ar remaining after treatment is believed to be enclosed in a relect mica in the HIV phases in the soils. The HIV is likely a mica-HIV intergrade. Based on these data, stable cesium has become significantly enriched relative to potassium in subsurface micaceous particles as a result of chemical weathering processes in the SRS Fuquay soils studied thus far. Our data permit the interpretation describing the sorption of Cs and Rb in an apex site or in a hard to reach hard-to-exchange sorption site during pedogenesis. In terms of testing the second hypothesis, our work is ongoing and we report some preliminary data on Cs-137 and Rb-85 exchange experiments on select SRS Fuquay soils (-2 mm). Our isotopic equilibration experiments using Cs and Rb isotopes in separate exchange experiments show only small amounts of Cs and Rb in the original sample is exchangeable isotopically for a period of a few weeks in acidified conditions. The isotope exchange experiments provide support for our interpretation that pedogenically accumulated Cs (and Rb) occupy sites that are unavailable to exchange or exchange slowly in acid conditions corresponding to present conditions in SRS soils. In more basic solutions, greater exchange isotopic exchange is noted and suggests an expansion of interlayer sites thereby permitting more isotopic exchange of Cs and Rb.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Steady State Sputtering Yields and Surface Compositions of Depleted Uranium and Uranium Carbide bombarded by 30 keV Gallium or 16 keV Cesium Ions.

Depleted uranium that included carbide inclusions was sputtered with 30-keV gallium ions or 16-kev cesium ions to depths much greater than the ions’ range, i.e. using steady-state sputtering. The recession of both the uranium’s and uranium carbide’s surfaces and the ion corresponding fluences were used to determine the steady-state target sputtering yields of both uranium and uranium carbide, i.e. 6.3 atoms of uranium and 2.4 units of uranium carbide eroded per gallium ion, and 9.9 uranium atoms and 3.65 units of uranium carbide eroded by cesium ions. The steady state surface composition resulting from the simultaneous gallium or cesium implantation and sputter-erosion of uranium and uranium carbide were calculated to be U₈₆Ga₁₄, (UC)₇₀Ga₃₀ and U₈₁Cs₉, (UC)₇₉Cs₂₁, respectively.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Microstructure analysis for chemical interaction between cesium and SUS 316 steel in fast breeder reactor application

In this study the corrosion products on a surface after cesium corrosion examination at 650 deg. C for 100 hrs were characterized by TEM observation around the corroded area on the surface in order to understand the corrosion mechanism of cesium fission product for cladding materials in fast reactor. The experimental results suggest the main corrosion mechanism occurred in the process of the separation of cesium chromate and metal (Fe, Ni). The main reaction of corrosion process was considered to be equation, 2Cs + 7/2 O{sub 2} + 2Cr {yields} Cs{sub 2}Cr{sub 2}O{sub 7}(L). (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Decontamination of Radioactive Cesium Released from Fukushima Daiichi Nuclear Power Plant - 13277

Peculiar binding of Cesium to the soil clay minerals remained the major obstacle for the immediate Cs-decontamination of soil and materials containing clay minerals like sludge. Experiments for the removal of Cesium from soil and ash samples from different materials were performed in the lab scale. For soil and sludge ash formed by the incineration of municipal sewage sludge, acid treatment at high temperature is effective while washing with water removed Cesium from ashes of plants or burnable garbage. Though total removal seems a difficult task, water-washing of wood-ash or garbage-ash at 40 deg. C removes >90% radiocesium, while >60% activity can be removed from soil and sludge-ash by acid washing at 95 deg. C. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Flowsheet Definition for the Tank Side Cesium Removal Unit and the Importance of Early Communication - 19142

The U.S. Department of Energy (DOE) tank operations contractor Washington River Protection Solutions, LLC (WRPS) is working toward the start of low-activity waste (LAW) treatment in direct feed mode as soon as 2022. WRPS is responsible for providing the pre-treated feed for this direct feed mode and had originally planned to use the Low Activity Waste Pretreatment System (LAWPS) to supply the initial feed in 2021. In September 2017, in response to a DOE-sponsored LAWPS program review, a new system was proposed to provide the initial feed during direct feed mode until a supplemental pretreatment capability is ready to begin processing feed. This system, known as the Tank Side Cesium Removal (TSCR) system, is based on the Savannah River Tank Closure Cesium Removal (TCCR) system and technology used to separate cesium out of reactor water at Fukushima. A preliminary flowsheet was needed to form the initial basis for future decisions and allow discussions between operations, project management, and the customer. The main goal of the TSCR flowsheet was to form a process flow diagram, process description, and much of the preliminary information to be used to help inform future decisions. When flowsheet development first began, little to no information was readily known and what was known needed to be compiled in one place and digestible by several audiences. The impacts of various parameters on the system also needed a vehicle for clear communication to varying audiences. While a more complicated model was being completed, a model of the process was created using Microsoft Excela which could have several parameters changed while maintaining basic logical requirements (such as treated waste volume cannot exceed the volume of the Interim LAW Storage Tank [ILST], must shutdown for so many days for column changeout, etc.). This program allowed the unit downtime, start dates, treatment rates, and several other variables to be modified and reflect the ILST storage volume as a function of mission progression. The model with several different parameters gathered from the various groups was combined into an early flowsheet of the TSCR process and created one of the first citable documents about TSCR implementation at Hanford. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗