Improved quantitation of SIMS depth profile measurements of niobium via sample holder design improvements and characterization of grain orientation effects

The importance of SIMS analyses for “N-doped” impurity alloyed niobium and other surface-alloyed materials continues to increase. A major hurdle is the uncertainty of instrument calibration due to changes in sample height either from sample surface topography or from the sample holder itself. The CAMECA sample holder design allows for many types of samples to be analyzed. However, a drawback is that the holder faceplate can bend, contributing an uncertainty in the relative sensitivity factor (RSF) used to quantify the SIMS results. Here, we describe an improved sample holder having a reinforced faceplate, which prevents deflection and reduces uncertainty. Simulations show that the new design significantly reduces deflection from 10 μm to 5 nm. Sample measurements show a reduction of RSF uncertainty from this source from 4.1% to 0.95%. Grain orientation has long been suspected to affect RSF measurement as well. A bicrystal implant standard, consisting of randomly oriented and [001] grains, was successively rotated 15° between analyses. It was observed that 20% of the analyses performed on the randomly oriented grain exhibited anomalously high RSF values as well as slow sputter rates. These features were associated with the changing grain normal orientation with respect to the primary Cs + beam. The grain orientation associated with the rise in RSF was simulated and determined to be the [101] crystallographic plane, thus indicating that ion channeling was responsible for the significantly increased RSF. Focused ion beam analysis confirmed slower sputter rates for the cardinal crystallographic orientations, indicating that ion channeling occurred for each.

43 PARTICLE ACCELERATORS↗

Gantry and isocenter displacements of a linear accelerator caused by an add-on micromultileaf collimator

Purpose: The delivery of high quality stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT) treatments to the patient requires knowledge of the position of the isocenter to submillimeter accuracy. To meet the requirements the deviation between the radiation and mechanical isocenters must be less than 1 mm. The use of add-on micromultileaf collimators ({mu}MLCs) in SRS and SRT is an additional challenge to the anticipated high-level geometric and dosimetric accuracy of the treatment. The aim of this work was to quantify the gantry excursions during rotation with and without an add-on {mu}MLC attached to the gantry head. In addition, the shift in the position of the isocenter and its correlation to the kV beam center of the cone-beam CT system was included in the study. Methods: The quantification of the gantry rotational performance was done using a pointer supported by an in-house made rigid holder attached to the gantry head of the accelerator. The pointer positions were measured using a digital theodolite. To quantify the effect of an {mu}MLC of 50 kg, the measurements were repeated with the {mu}MLC attached to the gantry head. The displacement of the isocenter due to an add-on {mu}MLC of 50 kg was also investigated. In case of the pointer measurement the {mu}MLC was simulated by weights attached to the gantry head. A method of least squares was applied to determine the position and displacement of the mechanical isocenter. Additionally, the displacement of the radiation isocenter was measured using a ball-bearing phantom and the electronic portal image device system. These measurements were based on 8 MV photon beams irradiated onto the ball from the four cardinal angles and two opposed collimator angles. The measurements and analysis of the data were carried out automatically using software delivered by the manufacturer. Results: The displacement of the mechanical isocenter caused by a 50 kg heavy {mu}MLC was found to be (-0.01 {+-} 0.05, -0.10 {+-} 0.03, -0.26 {+-} 0.05) mm in lateral, longitudinal, and vertical direction, respectively. Similarly, the displacement of the radiation isocenter was found to be (0.00 {+-} 0.03, -0.08 {+-} 0.06, -0.32 {+-} 0.02) mm. Good agreement was found between the displacement of the two isocenters. A displacement of the kV cone-beam CT beam center due to the attached weight of 50 kg could not be detected. Conclusions: General characteristics of the gantry arm excursions and displacements caused by an add-on {mu}MLC have been reported. A 50 kg heavy add-on {mu}MLC results in a isocenter displacement downward of 0.26-0.32 mm. The authors recommend that the beam center of the kV cone-beam CT image system should be matched to the isocenter related to the weight of the {mu}MLC. Consequently, the imperfections in isocenter localizations are transferred to the conventional radiotherapy where the clinical consequences of uncertainties in the submillimeter regime are negligible.

60 APPLIED LIFE SCIENCES↗

Automated x-ray/light field congruence using the LINAC EPID panel

Purpose: X-ray/light field alignment is a test described in many guidelines for the routine quality control of clinical linear accelerators (LINAC). Currently, the gold standard method for measuring alignment is through utilization of radiographic film. However, many modern LINACs are equipped with an electronic portal imaging device (EPID) that may be used to perform this test and thus subsequently reducing overall cost, processing, and analysis time, removing operator dependency and the requirement to sustain the departmental film processor. Methods: This work describes a novel method of utilizing the EPID together with a custom inhouse designed jig and automatic image processing software allowing measurement of the light field size, x-ray field size, and congruence between them. The authors present results of testing the method for aS1000 and aS500 Varian EPID detectors for six LINACs at a range of energies (6, 10, and 15 MV) in comparison with the results obtained from the use of radiographic film. Results: Reproducibility of the software in fully automatic operation under a range of operating conditions for a single image showed a congruence of 0.01 cm with a coefficient of variation of 0. Slight variation in congruence repeatability was noted through semiautomatic processing by four independent operators due to manual marking of positions on the jig. Testing of the methodology using the automatic method shows a high precision of 0.02 mm compared to a maximum of 0.06 mm determined by film processing. Intraindividual examination of operator measurements of congruence was shown to vary as much as 0.75 mm. Similar congruence measurements of 0.02 mm were also determined for a lower resolution EPID (aS500 model), after rescaling of the image to the aS1000 image size. Conclusions: The designed methodology was proven to be time efficient, cost effective, and at least as accurate as using the gold standard radiographic film. Additionally, congruence testing can be easily performed for all four cardinal gantry angles which can be difficult when using radiographic film. Therefore, the authors propose it can be used as an alternative to the radiographic film method allowing decommissioning of the film processor.

60 APPLIED LIFE SCIENCES↗

Dosimetric and geometric evaluation of a novel stereotactic radiotherapy device for breast cancer: The GammaPod Trade-Mark-Sign

Purpose: A dedicated stereotactic gamma irradiation device, the GammaPod Trade-Mark-Sign from Xcision Medical Systems, was developed specifically to treat small breast cancers. This study presents the first evaluation of dosimetric and geometric characteristics from the initial prototype installed at University of Maryland Radiation Oncology Department. Methods: The GammaPod Trade-Mark-Sign stereotactic radiotherapy device is an assembly of a hemi-spherical source carrier containing 36 {sup 60}Co sources, a tungsten collimator, a dynamically controlled patient support table, and the breast immobilization system which also functions as a stereotactic frame. The source carrier contains the sources in six columns spaced longitudinally at 60 Degree-Sign intervals and it rotates together with the variable-size collimator to form 36 noncoplanar, concentric arcs focused at the isocenter. The patient support table enables motion in three dimensions to position the patient tumor at the focal point of the irradiation. The table moves continuously in three cardinal dimensions during treatment to provide dynamic shaping of the dose distribution. The breast is immobilized using a breast cup applying a small negative pressure, where the immobilization cup is embedded with fiducials also functioning as the stereotactic frame for the breast. Geometric and dosimetric evaluations of the system as well as a protocol for absorbed dose calibration are provided. Dosimetric verifications of dynamically delivered patient plans are performed for seven patients using radiochromic films in hypothetical preop, postop, and target-in-target treatment scenarios. Results: Loaded with 36 {sup 60}Co sources with cumulative activity of 4320 Ci, the prototype GammaPod Trade-Mark-Sign unit delivers 5.31 Gy/min at the isocenter using the largest 2.5 cm diameter collimator. Due to the noncoplanar beam arrangement and dynamic dose shaping features, the GammaPod Trade-Mark-Sign device is found to deliver uniform doses to targets with good conformity. The spatial accuracy of the device to locate the radiation isocenter is determined to be less than 1 mm. Single shot profiles with 2.5 cm collimator are measured with radiochromic film and found to be in good agreement with respect to the Monte Carlo based calculations (congruence of FWHM less than 1 mm). Dosimetric verifications corresponding to all hypothetical treatment plans corresponding to three target scenarios for each of the seven patients demonstrated good agreement with gamma index pass rates of better than 97% (99.0%{+-} 0.7%). Conclusions: Dosimetric evaluation of the first GammaPod Trade-Mark-Sign stereotactic breast radiotherapy unit was performed and the dosimetric and spatial accuracy of this novel technology is found to be feasible with respect to clinical radiotherapy standards. The observed level of agreement between the treatment planning system calculations and dosimetric measurements has confirmed that the system can deliver highly complex treatment plans with remarkable geometric and dosimetric accuracy.

60 APPLIED LIFE SCIENCES↗

Quality assurance of asymmetric jaw alignment using 2D diode array

Purpose: A method using a 2D diode array is proposed to measure the junction gap (or overlap) and dose with high precision for routine quality assurance of the asymmetric jaw alignment.Methods: The central axis (CAX) of the radiation field was determined with a 15 × 15 cm{sup 2} photon field at four cardinal collimator angles so that the junction gap (or overlap) can be measured with respect to the CAX. Two abutting fields having a field size of 15 cm (length along the axis parallel to the junction) × 7.5 cm (width along the axis perpendicular to the junction) were used to irradiate the 2D diode array (MapCHECK2) with 100 MU delivered at the photon energy of 6 MV. The collimator was slightly rotated at 15° with respect to the beam central axis to increase the number of diodes effective on the measurement of junction gap. The junction gap and dose measured in high spatial resolution were compared to the conventional methods using an electronic portal imaging device (EPID) and radiochromic film, respectively. In addition, the reproducibility and sensitivity of the proposed method to the measurements of junction gap and dose were investigated.Results: The junction gap (or overlap) and dose measured by MapCHECK2 agreed well to those measured by the conventional methods of EPID and film (the differences ranged from −0.01 to 0 cm and from −1.34% to 0.6% for the gap and dose, respectively). No variation in the repeat measurements of the junction gap was found whereas the measurements of junction dose were found to vary in quite a small range over the days of measurement (0.21%–0.35%). While the sensitivity of the measured junction gap to the actual junction gap applied was the ideal value of 1 cm/cm as expected, the sensitivity of the junction dose to the actual junction gap increased as the junction gap (or overlap) decreased (maximum sensitivity: 201.7%/cm).Conclusions: The initial results suggest that the method is applicable for a comprehensive quality assurance of the asymmetric jaw alignment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-47: Development of a High-Precision, Image-Guided Radiotherapy, Multi- Purpose Radiation Isocenter Quality-Assurance Calibration and Checking System

Purpose: To develop a system that can define the radiation isocenter and correlate this information with couch coordinates, laser alignment, optical distance indicator (ODI) settings, optical tracking system (OTS) calibrations, and mechanical isocenter walkout. Methods: Our team developed a multi-adapter, multi-purpose quality assurance (QA) and calibration device that uses an electronic portal imaging device (EPID) and in-house image-processing software to define the radiation isocenter, thereby allowing linear accelerator (Linac) components to be verified and calibrated. Motivated by the concept that each Linac component related to patient setup for image-guided radiotherapy based on cone-beam CT should be calibrated with respect to the radiation isocenter, we designed multiple concentric adapters of various materials and shapes to meet the needs of MV and KV radiation isocenter definition, laser alignment, and OTS calibration. The phantom's ability to accurately define the radiation isocenter was validated on 4 Elekta Linacs using a commercial ball bearing (BB) phantom as a reference. Radiation isocenter walkout and the accuracy of couch coordinates, ODI, and OTS were then quantified with the device. Results: The device was able to define the radiation isocenter within 0.3 mm. Radiation isocenter walkout was within ±1 mm at 4 cardinal angles. By switching adapters, we identified that the accuracy of the couch position digital readout, ODI, OTS, and mechanical isocenter walkout was within sub-mm. Conclusion: This multi-adapter, multi-purpose isocenter phantom can be used to accurately define the radiation isocenter and represents a potential paradigm shift in Linac QA. Moreover, multiple concentric adapters allowed for sub-mm accuracy for the other relevant components. This intuitive and user-friendly design is currently patent pending.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-J-109: Testing the KV Imaging Center Congruence with Radiation Isocenter of Small MLC and SRS Cone Field On Two Machines

Purpose: Orthogonal kV image pairs are used for target localization when fiducial markers are implanted. CBCT is used to verify cone SRS setup. Therefore it is necessary to evaluate the isocenter congruence between radiation fields and kV imaging center. This study used a simple method to evaluate the isocenter congruence, and compared the results for MLC and cone fields on two different Linacs. Methods: Varian OBI block was attached on the couch. It has a central 1mm BB with markers on three surfaces to align with laser. KV and MV images were taken at four cardinal angles. A 3x3cm2 MLC field and a 20mm cone field were irradiated respectively. On each kV image, the distance from BB center to the kV graticule center were measured. On the MV image of MLC field, the center of radiation field was determined manually, while for cone field, the Varian AM maintenance software was used to analyze the distance between BB and radiation field. The subtraction of the two distances gives the discrepancy between kV and radiation centers. Each procedure was repeated on five days at Trilogy and TrueBeam respectively. Results: The maximum discrepancy was found in the longitudinal direction at 180° gantry angel. It was 1.5±0.1mm for Trilogy and 0.6±0.1mm for TrueBeam. For Trilogy, although radiation center wobbled only 0.7mm and image center wobbled 0.8mm, they wobbled to the opposite direction. KV Pair using gantry 180° should be avoided in this case. Cone vs. kV isocenter has less discrepancy than MLC for Trilogy. Conclusion: Radiation isocenter of MLC and cone field is different, so is between Trilogy and TrueBeam. The method is simple and reproducible to check kV and radiation isocenter congruence.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-551: PTV Is the Worst-Case of CTV in Photon Therapy

Purpose: To examine the supposition of the static dose cloud and adequacy of the planning target volume (PTV) dose distribution as the worst-case representation of clinical target volume (CTV) dose distribution for photon therapy in head and neck (H and N) plans. Methods: Five diverse H and N plans clinically delivered at our institution were selected. Isocenter for each plan was shifted positively and negatively in the three cardinal directions by a displacement equal to the PTV expansion on the CTV (3 mm) for a total of six shifted plans per original plan. The perturbed plan dose was recalculated in Eclipse (AAA v11.0.30) using the same, fixed fluence map as the original plan. The dose distributions for all plans were exported from the treatment planning system to determine the worst-case CTV dose distributions for each nominal plan. Two worst-case distributions, cold and hot, were defined by selecting the minimum or maximum dose per voxel from all the perturbed plans. The resulting dose volume histograms (DVH) were examined to evaluate the worst-case CTV and nominal PTV dose distributions. Results: Inspection demonstrates that the CTV DVH in the nominal dose distribution is indeed bounded by the CTV DVHs in the worst-case dose distributions. Furthermore, comparison of the D95% for the worst-case (cold) CTV and nominal PTV distributions by Pearson's chi-square test shows excellent agreement for all plans. Conclusion: The assumption that the nominal dose distribution for PTV represents the worst-case dose distribution for CTV appears valid for the five plans under examination. Although the worst-case dose distributions are unphysical since the dose per voxel is chosen independently, the cold worst-case distribution serves as a lower bound for the worst-case possible CTV coverage. Minor discrepancies between the nominal PTV dose distribution and worst-case CTV dose distribution are expected since the dose cloud is not strictly static. This research was supported by the NCI through grant K25CA168984, by The Lawrence W. and Marilyn W. Matteson Fund for Cancer Research, and by the Fraternal Order of Eagles Cancer Research Fund, the Career Development Award Program at Mayo Clinic.

60 APPLIED LIFE SCIENCES↗

SU-F-BRE-09: Linac Isocenter Quality Assurance: A Stereotactic Approach

Purpose: A quantitative method was designed to independently determine the couch/collimator/gantry isocenters, as well as the overall LINAC mechanical isocenter in 3D. Methods: Performed on both a Varian TrueBeam™ STx and Trilogy with the gold standard front pointer positioned at 100 cm SAD, and a Radionics XKnife™ (RX) attached to the couch. At gantry and couch 0°, the RX laser alignment attachment (RXLAA) was centered to the front pointer using the micrometers (0.1-mm precision) on the RX. The 3D coordinates of the micrometers were recorded. The collimator was rotated to 90° and 270°. At each collimator rotation, the RXLAA was re-centered to the front pointer and the micrometer coordinates recorded. At collimator and gantry 0°, the process was repeated for couch angles 0°/90°/270°. Finally, at collimator and couch 0°, the steps were repeated for gantry rotations 0°/90°/180°/270°. The centers/radii of the smallest bounding spheres for the collimator, couch and gantry walkout were calculated (using MatLab™). The smallest bounding sphere containing the collimator, couch and gantry walkout spheres was then calculated. The center of this all-encompassing sphere is the overall mechanical isocenter of the LINAC. This position was dialed in on the RX. LINAC mechanical and radiation isocenter coincidence was determined by performing Winston- Lutz test at four cardinal gantry angles. Results: TrueBeam and Trilogy mechanical isocenters had overall walkout radii of 0.8 mm and 1.5 mm, respectively. For the TrueBeam and Trilogy 6-MV beams, the radii of radiation isocenter were 0.3 mm and 0.4 mm, respectively, with distances between LINAC mechanical and radiation isocenters of 0.5 mm and 0.9 mm, respectively. Conclusion: This efficient and simple method allows for an independent and reliable quantitative assessment of LINAC isocenter in 3D with equipment typically available in a radiation oncology clinic. It can easily be performed for LINAC commissioning and annual QA.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-574: Novel Chance-Constrained Optimization in Intensity-Modulated Proton Therapy Planning to Account for Range and Patient Setup Uncertainties

Purpose: We propose to apply a probabilistic framework, namely chanceconstrained optimization, in the intensity-modulated proton therapy (IMPT) planning subject to range and patient setup uncertainties. The purpose is to hedge against the influence of uncertainties and improve robustness of treatment plans. Methods: IMPT plans were generated for a typical prostate patient. Nine dose distributions are computed — the nominal one and one each for ±5mm setup uncertainties along three cardinal axes and for ±3.5% range uncertainty. These nine dose distributions are supplied to the solver CPLEX as chance constraints to explicitly control plan robustness under these representative uncertainty scenarios with certain probability. This probability is determined by the tolerance level. We make the chance-constrained model tractable by converting it to a mixed integer optimization problem. The quality of plans derived from this method is evaluated using dose-volume histogram (DVH) indices such as tumor dose homogeneity (D5% – D95%) and coverage (D95%) and normal tissue sparing like V70 of rectum, V65, and V40 of bladder. We also compare the results from this novel method with the conventional PTV-based method to further demonstrate its effectiveness Results: Our model can yield clinically acceptable plans within 50 seconds. The chance-constrained optimization produces IMPT plans with comparable target coverage, better target dose homogeneity, and better normal tissue sparing compared to the PTV-based optimization [D95% CTV: 67.9 vs 68.7 (Gy), D5% – D95% CTV: 11.9 vs 18 (Gy), V70 rectum: 0.0 % vs 0.33%, V65 bladder: 2.17% vs 9.33%, V40 bladder: 8.83% vs 21.83%]. It also simultaneously makes the plan more robust [Width of DVH band at D50%: 2.0 vs 10.0 (Gy)]. The tolerance level may be varied to control the tradeoff between plan robustness and quality. Conclusion: The chance-constrained optimization generates superior IMPT plan compared to the PTV-based optimization with explicit control of plan robustness. NIH/NCI K25CA168984, Eagles Cancer Research Career Development, The Lawrence W. and Marilyn W. Matteson Fund for Cancer Research, Mayo ASU Seed Grant, and The Kemper Marley Foundation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-584: Optical Tracking Guided Patient-Specific VMAT QA with ArcCHECK

Purpose: To investigate the novel use of an in-house optical tracking system (OTS) to improve the efficacy of VMAT QA with a cylindrical dosimeter (ArcCHECK™). Methods: The translational and rotational setup errors of ArcCHECK are convoluted which makes it challenging to position the device efficiently and accurately. We first aligned the ArcCHECK to the machine cross-hair at three cardinal angles (0°, 90°, and 270°) to establish a reference position. Four infrared reflective markers were attached to the back of the device. An OTS with 0.2mm/0.2° accuracy was used to control its setup uncertainty. Translational uncertainties of 1 mm and 2 mm in three directions (in, right, and up) were applied on the device. Four open beams of various field sizes and six clinical VMAT arcs were delivered and measured for all simulated setup errors. The measurements were compared with Pinnacle™ calculations using Gamma analysis to evaluate the impact of setup uncertainty. This study also evaluated the improvement in setup reproducibility and efficiency with the aid of the OTS. Results: For open beams, with 3%/3mm, the mean passing rates dropped by less than 5% for all shifts; with 2%/2mm, two significant drops(>5%) were observed: 15.38±6.75% for 2 mm lateral shift and 9.35±4.88% for 2 mm longitudinal shift. For VMAT arcs, the mean passing rates using 2%/2mm dropped by 10.47±7.46% and 22.02±11.39% for 1 and 2 mm shift, respectively. With 3%/3mm, significant drop only occurred with 2 mm longitudinal shift (13.73±8.30%). Setup time could be reduced by >15 min with the aid of the OTS. Conclusion: OTS is an effective tool for separating translational and rotational uncertainties. The current VMAT QA solution was not strongly sensitive to translation errors of 2mm with widely accepted criterion (3%/3mm). This finding raises concerns regarding the efficacy of such QA system in detecting errors in the dynamic VMAT delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-642: PTV Is the Voxel-Wise Worst-Case of CTV in Prostate Photon Therapy

Purpose: To examine the adequacy of the planning target volume (PTV) dose distribution as the worst-case representation of clinical target volume (CTV) dose distribution in prostate volumetric-modulated arc therapy (VMAT) plans. Methods: Ten intact prostate cancer cases treated by VMAT at our institution were randomly selected. Isocenter was shifted in the three cardinal directions by a displacement equal to the PTV expansion on the CTV (±3 mm) for a total of six shifted plans per original plan. Rotationally-perturbed plans were generated with a couch rotation of ±1° to simulate patient yaw. The eight perturbed dose distributions were recalculated in the treatment planning system using the same, fixed fluence map as the original plan. The voxel-wise worst-case CTV dose distribution was constructed from the minimum value per voxel from the eight perturbed doses. The resulting dose volume histograms (DVH) were evaluated for statistical correlation between the worst-case CTV and nominal PTV dose distributions based on D95% by Wilcoxon signed-rank test with significance level p ≤ 0.05. Results: Inspection demonstrates the PTV DVH in the nominal dose distribution is bounded by the CTV DVH in the worst-case dose distribution. Comparison of D95% for the two dose distributions by Wilcoxon signed-rank test gives p = 0.131. Therefore the null hypothesis cannot be rejected since the difference in median values is not statistically significant. Conclusion: The assumption that the nominal dose distribution for PTV represents the worst-case dose distribution for CTV appears valid for the ten plans under examination. Although the worst-case dose distribution is unphysical since the dose per voxel is chosen independently, it serves as a lower bound for the possible CTV coverage. Furthermore, this is consistent with the unphysical nature of the PTV. Minor discrepancies between the two dose distributions are expected since the dose cloud is not strictly static. Funding Support: NIH/NCI K25CA168984, Eagles Cancer Research Career Development, The Lawrence W. and Marilyn W. Matteson Fund for Cancer Research, Mayo ASU Seed Grant, and The Kemper Marley Foundation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-AB-201-09: Calibration of An Element of a New Directional Pd-103 Planar Source Array

Purpose: The CivaSheet™ is a new directional Pd-103 planar source array, with a variable number of discrete source elements referred to as “dots”. Each dot consists of a polymer capsule containing {sup 103}Pd and a gold shield that attenuates radiation on one side of the device to define hot and cold dose regions. Fluorescence from the gold shield is observed in the dot spectrum. Since CivaSheet™ is a planar directional source, conventional methods used for calibration of azimuthally symmetric sources are not applicable. The purpose of this work is to establish an air-kerma-strength standard and a transfer to a well chamber for clinical calibration. Methods: Primary air-kerma strength measurement of the dots was performed using a variable-aperture free-air chamber (VAFAC). Charge measurements were recorded using a well chamber with a custom insert. Anisotropy measurements were performed using a Sodium-Iodide detector. Spectral measurements were performed using a low-energy germanium detector and compared to a source without gold. The dot geometry was modeled using the MCNP6 radiation transport code. Results: Air-kerma strength measurements of a batch of four dots performed with the VAFAC were within ±1.5% of the average measured value and the measurement precision was within ±0.5%. Anisotropy measurements indicated uniform emission within the measurement uncertainty for the solid angle defining the VAFAC aperture used. Charge measurements of each dot using the well chamber in four cardinal angle source orientations were within ±1.5% of the average measured values. The spectral study of a dot resulted in identification of fluorescence from the gold shield and primary spectral energies that were compared to MCNP6 simulations. Conclusion: Calibration procedures for the new directional Pd-103 source dot were established for future clinical use, based on the results of experimental and Monte Carlo investigations. This work was partially supported by NCI contract (HHSN261201200052C) through CivaTech Oncology Inc.

60 APPLIED LIFE SCIENCES↗

SU-F-T-313: Clinical Results of a New Customer Acceptance Test for Elekta VMAT

Purpose: To report the results of a customer acceptance test (CAT) for VMAT treatments for two matched Elekta linear accelerators. Methods: The CAT tests were performed on two clinically matched Elekta linear accelerators equipped with a 160-leaf MLC. Functional tests included performance checks of the control system during dynamic movements of the diaphragms, MLC, and gantry. Dosimetric tests included MLC picket fence tests at static and variable dose rates and a diaphragm alignment test, all performed using the on-board EPID. Additionally, beam symmetry during arc delivery was measured at the four cardinal angles for high and low dose rate modes using a 2D detector array. Results of the dosimetric tests were analyzed using the VMAT CAT analysis tool. Results: Linear accelerator 1 (LN1) met all stated CAT tolerances. Linear accelerator 2 (LN2) passed the geometric, beam symmetry, and MLC position error tests but failed the relative dose average test for the diaphragm abutment and all three picket fence fields. Though peak doses in the abutment regions were consistent, the average dose was below the stated tolerance corresponding to a leaf junction that was too narrow. Despite this, no significant differences in patient specific VMAT quality assurance measured were observed between the accelerators and both passed monthly MLC quality assurance performed with the Hancock test. Conclusion: Results from the CAT showed LN2 with relative dose averages in the abutment regions of the diaphragm and MLC tests outside the tolerances resulting from differences in leaf gap distances. Tolerances of the dose average tests from the CAT may be small enough to detect MLC errors which do not significantly affect patient QA or the routine MLC tests.

60 APPLIED LIFE SCIENCES↗

SU-F-T-476: Performance of the AS1200 EPID for Periodic Photon Quality Assurance

Purpose: To assess the dosimetric performance of a new amorphous silicon flat-panel electronic portal imaging device (EPID) suitable for high-intensity, flattening-filter-free delivery mode. Methods: An EPID-based QA suite was created with automation to periodically monitor photon central-axis output and two-dimensional beam profile constancy as a function of gantry angle and dose-rate. A Varian TrueBeamTM linear accelerator installed with Developer Mode was used to customize and deliver XML script routines for the QA suite using the dosimetry mode image acquisition for an aS1200 EPID. Automatic post-processing software was developed to analyze the resulting DICOM images. Results: The EPID was used to monitor photon beam output constancy (central-axis), flatness, and symmetry over a period of 10 months for four photon beam energies (6x, 15x, 6xFFF, and 10xFFF). EPID results were consistent to those measured with a standard daily QA check device. At the four cardinal gantry angles, the standard deviation of the EPID central-axis output was <0.5%. Likewise, EPID measurements were independent for the wide range of dose rates (including up to 2400 mu/min for 10xFFF) studied with a standard deviation of <0.8% relative to the nominal dose rate for each energy. Also, profile constancy and field size measurements showed good agreement with the reference acquisition of 0° gantry angle and nominal dose rate. XML script files were also tested for MU linearity and picket-fence delivery. Using Developer Mode, the test suite was delivered in <60 minutes for all 4 photon energies with 4 dose rates per energy and 5 picket-fence acquisitions. Conclusion: Dosimetry image acquisition using a new EPID was found to be accurate for standard and high-intensity photon beams over a broad range of dose rates over 10 months. Developer Mode provided an efficient platform to customize the EPID acquisitions by using custom script files which significantly reduced the time. This work was funded in part by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

TH-CD-209-04: Fuzzy Robust Optimization in Intensity-Modulated Proton Therapy Planning to Account for Range and Patient Setup Uncertainties

Purpose: We propose to apply a robust optimization model based on fuzzy-logic constraints in the intensity-modulated proton therapy (IMPT) planning subject to range and patient setup uncertainties. The purpose is to ensure the plan robustness under uncertainty and obtain the best trade-off between tumor dose coverage and organ-at-risk(OAR) sparing. Methods: Two IMPT plans were generated for 3 head-and-neck cancer patients: one used the planning target volume(PTV) method; the other used the fuzzy robust optimization method. In the latter method, nine dose distributions were computed - the nominal one and one each for ±3mm setup uncertainties along three cardinal axes and for ±3.5% range uncertainty. For tumors, these nine dose distributions were explicitly controlled by adding hard constraints with adjustable parameters. For OARs, fuzzy constraints that allow the dose to vary within a certain range were used so that the tumor dose distribution was guaranteed by minimum compromise of that of OARs. We rendered this model tractable by converting the fuzzy constraints to linear constraints. The plan quality was evaluated using dose-volume histogram(DVH) indices such as tumor dose coverage(D95%), homogeneity(D5%-D95%), plan robustness(DVH band at D95%), and OAR sparing like D1% of brain and D1% of brainstem. Results: Our model could yield clinically acceptable plans. The fuzzy-logic robust optimization method produced IMPT plans with comparable target dose coverage and homogeneity compared to the PTV method(unit: Gy[RBE]; average[min, max])(CTV D95%: 59 [52.7, 63.5] vs 53.5[46.4, 60.1], CTV D5% - D95%: 11.1[5.3, 18.6] vs 14.4[9.2, 21.5]). It also generated more robust plans(CTV DVH band at D95%: 3.8[1.2, 5.6] vs 11.5[6.2, 16.7]). The parameters of tumor constraints could be adjusted to control the tradeoff between tumor coverage and OAR sparing. Conclusion: The fuzzy-logic robust optimization generates superior IMPT with minimum compromise of OAR sparing. This research was supported by the National Cancer Institute Career Developmental Award K25CA168984, by the Fraternal Order of Eagles Cancer Research Fund Career Development Award, by The Lawrence W. and Marilyn W. Matteson Fund for Cancer Research, by Mayo Arizona State University Seed Grant, and by The Kemper Marley Foundation. eRA Person ID(s) for the Principal Investigator: 11017970 (Research Supported by National Institutes of Health)

60 APPLIED LIFE SCIENCES↗

Electron–Hole Dimers in the Parent Phase of Quasi–2D Cuprates

The key feature of parent cuprates of the La{sub 2}CuO{sub 4} type, in addition to their high ionic polarizability and closeness to polarization catastrophe, is identified as their instability against charge transfer that is accompanied by the formation of a system of metastable dipole-active Mott–Hubbard excitons, i.e., electron–hole (EH) dimers. This feature determines the behavior of cuprates upon nonisovalent substitution. Within the simplest model equivalent to a system of composite bosons, nonisovalent substitution shifts the phase equilibrium toward condensation of EH dimers and the formation of inhomogeneous EH liquid. To describe the electronic state of doped cuprates effectively, we propose to use the pseudospin S = 1 formalism. It enables us to treat cardinally new charged states such as Anderson’s RVB phases. Recombination of EH dimers at a critically low energy of local and nonlocal correlations drives the system into the state of a Fermi liquid.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

GrammarViz 3.0: Interactive Discovery of Variable-Length Time Series Patterns

The problems of recurrent and anomalous pattern discovery in time series, e.g., motifs and discords, respectively, have received a lot of attention from researchers in the past decade. However, since the pattern search space is usually intractable, most existing detection algorithms require that the patterns have discriminative characteristics and have its length known in advance and provided as input, which is an unreasonable requirement for many real-world problems. In addition, patterns of similar structure, but of different lengths may co-exist in a time series. In order to address these issues, we have developed algorithms for variable-length time series pattern discovery that are based on symbolic discretization and grammar inference—two techniques whose combination enables the structured reduction of the search space and discovery of the candidate patterns in linear time. In this work, we present GrammarViz 3.0—a software package that provides implementations of proposed algorithms and graphical user interface for interactive variable-length time series pattern discovery. The current version of the software provides an alternative grammar inference algorithm that improves the time series motif discovery workflow, and introduces an experimental procedure for automated discretization parameter selection that builds upon the minimum cardinality maximum cover principle and aids the time series recurrent and anomalous pattern discovery.

97 MATHEMATICS AND COMPUTING↗