Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Calorimeters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Heterogeneous techniques for rescaling energy deposits in the CMS Phase-2 endcap calorimeter

We present the porting to heterogeneous architectures of the algorithm used for applying linear transformations of raw energy deposits in the CMS High Granularity Calorimeter (HGCAL). This is the first heterogeneous algorithm to be fully integrated with HGCAL’s reconstruction chain. After introducing the latter and giving a brief description of the structural components of HGCAL relevant for this work, the role of the linear transformations in the calibration is reviewed. The many ways in which parallelization is achieved are described, and the successful validation of the heterogeneous algorithm is covered. Detailed performance measurements are presented, including throughput and execution time for both CPU and GPU algorithms, therefore establishing the corresponding speedup. We finally discuss the interplay between this work and the porting of other algorithms in the existing reconstruction chain, as well as integrating algorithms previously ported but not yet integrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Porting ATLAS Fast Calorimeter Simulation to GPUs with Performance Portable Programming Models

FastCaloSim is a parameterized simulation of the particle energy response and of the energy distribution in the ATLAS calorimeter. It is a relatively small and self-contained package with massive inherent parallelism and captures the essence of GPU offloading via important operations like data transfer, memory initialization, floating point operations, and reduction. It was identified by the High Energy Physics Center for Computational Excellence project as a good testbed for evaluating the performance and ease of portability of programming models. In this paper, we will discuss the results of our evaluation of the porting process to Kokkos, SYCL, Alpaka, OpenMP and std::par (nvc++), and compare performance on NVIDIA, AMD and Intel GPUs, as well as multicore CPUs.

97 MATHEMATICS AND COMPUTING↗

Anomaly Detection Based on Machine Learning for the CMS Electromagnetic Calorimeter Online Data Quality Monitoring

Using a semi-supervised machine learning approach we present a real-time anomaly detection system based on an autoencoder used for online data quality monitoring of the CMS electromagnetic calorimeter operating at the CERN LHC. We introduce a novel method that maximizes the anomaly detection performance making use of the time-dependence of anomalies and the spatial variations in the detector response. The autoencoder-based system efficiently detects anomalies in real time and maintains a very low false discovery rate. We validate the performance of this novel system with anomalies from LHC collision data taken in 2018 and 2022. In addition, results are presented after deploying the autoencoder-based system in the CMS online Data Quality Monitoring workflow at the beginning of LHC Run 3 resulting in the system to detect issues that were missed by the existing system.

Harilal, Abhirami [Carnegie Mellon University, Pit↗

Aluminum relaxation as the source of excess low energy events in low threshold calorimeters

A previously unexplained background called the Low Energy Excess has negatively impacted the reach of a variety of low threshold calorimeters including light dark matter direct detection and coherent elastic neutrino-nucleus scattering experiments. The relaxation of stressed aluminum films as mediated by the motion of dislocations may account for these observations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Low energy backgrounds and excess noise in a two-channel low-threshold calorimeter

Here, we describe observations of low energy excess (LEE) events, background events observed in all light dark matter direct detection calorimeters, and noise in a transition edge sensor based two-channel silicon athermal phonon detector with 375 meV baseline energy resolution. We measure two distinct LEE populations: “shared” multichannel events with a pulse shape consistent with substrate athermal phonon events and sub-eV events that couple nearly exclusively to a single channel with a significantly faster pulse shape. These “singles” are consistent with events occurring within the aluminum athermal phonon collection fins. Similarly, our measured detector noise is higher than the theoretical expectation. Measured noise can be split into an uncorrelated component, consistent with shot noise from small energy depositions within the athermal phonon sensor itself, and a correlated component, consistent with shot noise from energy depositions within the silicon substrate's phonon system.

47 OTHER INSTRUMENTATION↗

Readout electronics for the CMS Phase II Endcap Calorimeter: system overview and prototyping experience

Abstract The frontend readout system for the silicon section of the CMS Phase II Endcap Calorimeter faces unique challenges due to the high channel count and associated bandwidth, limited physical space, as well as radiation tolerance requirements. I will give an overview of the frontend electronics design and will discuss the recent experience obtained from the first test system that integrates the HGCROC2 readout ASIC, lpGBT, and VTRX+ in a realistic manner, linking together prototypes of the hexaboard, engine, and wagon boards.

Instruments & Instrumentation↗

An energy-dependent electro-thermal response model of CUORE cryogenic calorimeter

The Cryogenic Underground Observatory for Rare Events (CUORE) is the most sensitive experiment searching for neutrinoless double-beta decay (0νββ) in 130 Te. CUORE uses a cryogenic array of 988 TeO 2 calorimeters operated at ~10 mK with a total mass of 741 kg. To further increase the sensitivity, the detector response must be well understood. Here, we present a non-linear thermal model for the CUORE experiment on a detector-by-detector basis. We have examined both equilibrium and dynamic electro-thermal models of detectors by numerically fitting non-linear differential equations to the detector data of a subset of CUORE channels which are well characterized and representative of all channels. Further, we demonstrate that the hot-electron effect and electric-field dependence of resistance in NTD-Ge thermistors alone are inadequate to describe our detectors' energy-dependent pulse shapes. We introduce an empirical second-order correction factor in the exponential temperature dependence of the thermistor, which produces excellent agreement with energy-dependent pulse shape data up to 6 MeV. We also present a noise analysis using the fitted thermal parameters and show that the intrinsic thermal noise is negligible compared to the observed noise for our detectors.

47 OTHER INSTRUMENTATION↗

Convolutional L2LFlows: generating accurate showers in highly granular calorimeters using convolutional normalizing flows

Abstract In the quest to build generative surrogate models as computationally efficient alternatives to rule-based simulations, the quality of the generated samples remains a crucial frontier. So far, normalizing flows have been among the models with the best fidelity. However, as the latent space in such models is required to have the same dimensionality as the data space, scaling up normalizing flows to high dimensional datasets is not straightforward. The prior L2LFlows approach successfully used a series of separate normalizing flows and sequence of conditioning steps to circumvent this problem. In this work, we extend L2LFlows to simulate showers with a 9-times larger profile in the lateral direction. To achieve this, we introduce convolutional layers and U-Net-type connections, move from masked autoregressive flows to coupling layers, and demonstrate the successful modelling of showers in the ILD Electromagnetic Calorimeter as well as Dataset 3 from the public CaloChallenge dataset.

Instruments & Instrumentation↗

A Radiation-Hard 8-Channel 15-Bit 40-MSPS ADC for the ATLAS Liquid Argon Calorimeter Readout

The custom design of a radiation-hardened, 8-channel, 40-MSPS, 15-bit resolution, 14.2-bit dynamic range, 11.4-ENOB ADC data acquisition ASIC fabricated in a commercial 65-nm triple-well CMOS technology is presented. The ADC is developed for and integrates seamlessly into the readout system for the ATLAS liquid argon (LAr) calorimeter in the high-luminosity large hadron collider (HLLHC) upgrade at CERN, which will require a total of 364 936 ADC channels. A three-stage MDAC+SAR pipelined ADC architecture was designed to meet the physics requirements and scientific goals of the ATLAS experiment. The ADC is a fully self-contained data acquisition system that includes foreground calibration, digital data processing, digital control, and supporting circuitry. The measured performance shows the ADC achieves a competitive dynamic range and SNDR, and it meets or exceeds the ATLAS analog requirements. Radiation tolerance and scalability design considerations were implemented at the device-, circuit-, and system-level. Radiation-hardening-by-design techniques used include redundancy for digital circuits, the use of MiM capacitors, and a hybrid RC-DAC for the ADC core. The ADC ASIC was demonstrated to be robust against the effects of the intense radiation expected in the HL-LHC experimental environment.

DAQ↗

Design and Beam Test Results for the 2-D Projective sPHENIX Electromagnetic Calorimeter Prototype

sPHENIX is a new experiment under construction for the Relativistic Heavy Ion Collider at Brookhaven National Laboratory which will study the quark-gluon plasma to further the understanding of quantum chromodynamics (QCP) matter and interactions. A prototype of the sPHENIX electromagnetic calorimeter (EMCal) was tested at the Fermilab Test Beam Facility in Spring 2018 as experiment T-1044.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Study of energy response and resolution of the ATLAS Tile Calorimeter to hadrons of energies from 16 to 30 GeV

Three spare modules of the ATLAS Tile Calorimeter were exposed to test beams from the Super Proton Synchrotron accelerator at CERN in 2017. The detector’s measurements of the energy response and resolution to positive pions and kaons, and protons with energies ranging from 16 to 30 GeV are reported. The results have uncertainties of a few percent. They were compared to the predictions of the Geant4-based simulation program used in ATLAS to estimate the response of the detector to proton-proton events at the Large Hadron Collider. The determinations obtained using experimental and simulated data agree within the uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Counting Calories: Light Yield Studies for ADRIANO Calorimeter Prototype

To estimate the light yield for ADRIANO prototype, we must calibrate the light sensors as well as collect data from beams of known properties. Future experiments searching for new physics require special calorimetric techniques to detect new particles. ADRIANO2(A Dual Readout Integrally Active Non-segmented Option) is one such technique. Several prototypes have been tested at Mtest Facility at Fermi National Accelerator Laboratory in the last few years. This work consisting of new and more refined analysis of the data taken with the intent of improving the understanding of this calorimeter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The beam test of the lead tungstate calorimeter prototype with SiPM readout at Jefferson Lab

The lead tungstate crystals (PWO4) are a well-known radiator material for precise homogeneous electromagnetic calorimetry. In nuclear physics experiments, the typical way to read out the crystals is using conventional photomultiplier tubes (PMTs). In the case of the presence of a magnetic field, such a method has some complications and requires a passive PMT shielding design. The recent development of Silicon Photomultipliers (SiPMs) with small pixel pitch sizes and relatively small noise levels opens an opportunity avenue to use such a device as an alternative to conventional PMTs. The SiPM readout method may be beneficial for future nuclear physics and collider experiments. We are presenting the beam test results of the calorimeter prototype instrumented with SiPM readout performed at Jefferson Lab. The SiPM readout performance was compared with PMT readout measured at the same experimental conditions. The prototype was successfully tested using beam of photons in the energy range between 3 GeV and 11 GeV in experimental Hall D. The detector performance was also studied using a secondary beam of positrons provided by Hall D pair spectrometer.

Berdnikov, Vladimir↗

Scattering Calorimeter FY24 Deliverable Report

A simulation-based method has been developed to prototype new detector designs for nuclear data measurements utilizing neutron scattering. This method uses representative physics inputs for signal and background generation, full detector resolution smearing benchmarked by experimental data, and a neutron beam timing simulation to produce analyzable output like a physical measurement. A test case has been studied using a hybrid time-of-flight calorimeter detector for scattering cross-section measurements on 239 Pu with 1-5 MeV incident monoenergetic neutrons. Data analysis methods have been developed to perform event-level particle reconstruction and reaction channel discrimination. This analysis has been used to estimate the capability of the test detector to perform simultaneous scattering and fission cross section measurements, as well as its ability to provide neutron spectra and particle angular information.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Thermal Studies of CMS High-Granularity Calorimeter (HGCAL) Cassettes for the HL-LHC Upgrade

The CMS High Granularity Calorimeter (HGCAL) is a key endcap upgrade for the High-Luminosity LHC, designed to operate in an environment of extreme radiation and high particle rates. Each HGCAL cassette integrates silicon and scintillator modules, front-end ASICs, and a copper cooling plate that provides both mechanical integrity and thermal coupling using two-phase CO₂ cooling. Stable and uniform temperature control is essential to ensure reliable performance of the front-end electronics and to limit radiation-induced leakage currents in the silicon sensors. We present results from thermal characterization studies of pre-series HGCAL cassettes assembled and tested at Fermilab. Embedded RTD/PT1000 temperature sensors were used to measure gradients across copper cooling plates, module layers, and cassette edges under powering conditions representative of operation. The measured thermal behavior demonstrates effective heat transport through the cassette stack and highlights small but systematic variations correlated with geometry and assembly tolerances. These results validate the cooling performance of HGCAL cassettes.

Wang, Jinglu [Northwestern U.]↗

CLUE: A Fast Parallel Clustering Algorithm for High Granularity Calorimeters in High-Energy Physics

One of the challenges of high granularity calorimeters, such as that to be built to cover the endcap region in the CMS Phase-2 Upgrade for HL-LHC, is that the large number of channels causes a surge in the computing load when clustering numerous digitized energy deposits (hits) in the reconstruction stage. In this article, we propose a fast and fully parallelizable density-based clustering algorithm, optimized for high-occupancy scenarios, where the number of clusters is much larger than the average number of hits in a cluster. The algorithm uses a grid spatial index for fast querying of neighbors and its timing scales linearly with the number of hits within the range considered. We also show a comparison of the performance on CPU and GPU implementations, demonstrating the power of algorithmic parallelization in the coming era of heterogeneous computing in high-energy physics.

Rovere, Marco↗