Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMPRESSOR EFFICIENCY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Energy and exergy analysis of multi-stage vacuum membrane distillation integrated with mechanical vapor compression

Membrane distillation (MD) is a promising candidate for desalinating hypersaline brine, but its poor energy efficiency has remained a major barrier for widespread application. One possible solution to this issue is to recover the latent heat in the process. In this work, a multi-stage vacuum MD (MSVMD) was integrated with a mechanical vapor compressor (MVC) to enhance the latent heat recovery, and the energetic and exergetic performance of this integrated process was examined. A comprehensive energy and exergy analysis is provided to compare MSVMD and MSVMD-MVC processes for desalination of hypersaline brine. This analysis was conducted by examining the effect of the compression ratio on the energetic and exergetic performance, and the findings are reported in terms of specific thermal energy consumption (STEC), specific electricity consumption (SEC), and exergetic efficiency. The energy analysis shows that thermal energy consumption can be reduced as the compression ratio increases, due to the enhancement of latent heat recovery. The MSVMD-MVC process can be operated in a steady-state condition, without the need for thermal heat input; with STEC and SEC of 0 and 49 kWh/m 3 at the feed temperature of 50 °C and MVC compression ratio of 2.14. Moreover, exergy analysis demonstrates the efficacy of the eNRTL model in exergy calculation. Exergy destruction can be greatly reduced by increasing the compression ratio to an optimal value. For high salinity brine (124 g/L), MSVMD-MVC achieved a higher exergetic efficiency of 6.85%, compared to 2.42% in MSVMD. Furthermore, the result suggests that the application of MVC can intensify the energy efficiency and exergetic efficiency of the MSVMD system, although this process cannot outperform the current desalination technologies from the standard primary energy point of view.

42 ENGINEERING↗

Process for retrofitting an industrial gas turbine engine for increased power and efficiency

A process for retrofitting an industrial gas turbine engine of a power plant where an old industrial engine with a high spool has a new low spool with a low pressure turbine that drives a low pressure compressor using exhaust gas from the high pressure turbine, and where the new low pressure compressor delivers compressed air through a new compressed air line to the high pressure compressor through a new inlet added to the high pressure compressor. The old electric generator is replaced with a new generator having around twice the electrical power production. One or more stages of vanes and blades are removed from the high pressure compressor to optimally match a pressure ratio split. Closed loop cooling of one or more new stages of vanes and blades in the high pressure turbine is added and the spent cooling air is discharged into the combustor.

Jones, Russell B.↗

Automotive fuel cell stack and system efficiency and fuel consumption based on vehicle testing on a chassis dynamometer at minus 18 °C to positive 35 °C temperatures

In this work we present an in-depth laboratory technology assessment of a 2016 Toyota Mirai Fuel Cell (FC) vehicle based on chassis dynamometer testing. The 114.6 kW FC stack has a high dynamic response, which makes this powertrain a FC-dominant hybrid electric vehicle. The measured peak efficiency is 66.0% FC stack and 63.7% FC system with an idle hydrogen flow rate of 4.39 g/hr. The high FC system efficiencies at low loads match typical vehicle power spectrums, resulting in a high average vehicle efficiency of 62% compared to 45% and 23% for a hybrid electric vehicle and a conventional vehicle, respectively. An energy breakdown accounts for the FC stack losses, FC system losses, air compressor loads, and heater loads for different drive cycles and different thermal conditions. The cold-start North American city drive cycle (UDDS) energy consumption values are, respectively, 758, 581, 226, and 321 Wh/km at ambient conditions of -18 degrees C, -7 degrees C, -25 degrees C and 35 degrees C with 850 W/m 2 of solar loading. The FC system shutdown and startup processes at temperatures below the freezing point contribute to the increased hydrogen consumption. Additionally, the raw test data files are available for download, thus providing the research community with a public reference data on a modern production automotive FC system.

08 HYDROGEN↗

A Year-Round Energy-Efficient Fresh Air Handling System with Two-Stage Heat Pumps and Lake Water Pre-Treatment

Supplying fresh air is important for indoor air quality, but the energy consumption to treat fresh air is significant. The main problems in existing fresh air system include: supplying single-temperature water to treat fresh air and not applying natural energy sufficiently restrict the efficiency improvement of cooling and heat sources; unused air handling devices under most operating conditions throughout the year increase the fan energy consumption. Thus, this study proposes an efficient fresh air system that uses lake water to pre-treat fresh air and two-stage heat pumps for further treatment, and the unused air handling devices in the system are bypassed. A fresh air system in northern China is selected as a case to show the annual energy performance of the proposed system, and a comparative analysis is conducted between the proposed system and a traditional system. The results show that the annual energy-savings of the proposed system compared to the traditional system come from fans, and compressors, which are 56.5%, and 31.1%, respectively, with an entire system energy saving of 32.2%. The proposed system can achieve an annual system coefficient of performance (COP) of 5.5. This study provides potential for further improving the energy efficiency in fresh air treatment.

Liang, Chenjiyu↗

RENEWABLE MARINE-SOURCE INTEGRATED HEAT PUMP FOR SPACE CONDITIONING, WATER HEATING, AND FRESH WATER HARVESTING IN REMOTE COASTAL AND ISLAND COMMUNITIES

US coastal and island communities have vulnerable energy infrastructure and high energy costs, which are exacerbated by climate change. A unique opportunity exists to use thermal energy from year-round mild temperature variations to satisfy the broad energy needs of these communities. The US Department of Energy’s Oak Ridge National Laboratory designed a small-scale marine-source integrated heat pump (MS-IHP) that, as a single appliance, combines space conditioning, dehumidification (including fresh water harvesting from humid air), and water heating for home and commercial building applications in remote coastal and island communities. The unique, innovative features of the MS-IHP offer improved efficiency and substantially reduced costs for space conditioning, dehumidification, and water heating by seamlessly integrating a heat pump, heat pump water heater, and dehumidifier by using a single compressor; optimal year-round space cooling and heating, dehumidification, water harvesting, and water heating; and improved thermal comfort and reliable operation without frosting and defrosting because of the ocean’s warm temperatures and high heat capacity. Preliminary testing was conducted by retrofitting a commercial heat pump, demonstrating an outperformed performance compared with traditional air-source heat pumps. The MS-IHP technology can help decarbonize energy systems in remote coastal and island communities.

Gao, Zhiming [ORNL] (ORCID:0000000271397995)↗

Compressor is A Sensor (Final Report)

The performance of the heat pump system varies greatly depending on the refrigerant charge amount. Improving the refrigerant charge fault detection and diagnostics (FDD) method of vapor compression systems have the potential for increasing energy efficiency and reducing service cost. Previous studies to predict refrigerant charge amount are mostly empirical methods which require significant amount of experimental data for high accuracy. The primary goal of this research is to develop a charge fault detection method which requires only a few experimental data with high prediction accuracy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hybrid Ceramic-CMC Vane with EBC for Future Coal Derived Syngas Fired 65% Efficient Turbine Combined Cycle

The efficiency of both simple cycle and combined cycle power generation systems scale with the peak temperature at which the gas exits the combustor to drive the turbine. In conventional systems, a substantial fraction of the total turbine core flow exiting the compressor is diverted downstream to cool metallic turbine hardware rather than power the turbine, much of which is used to cool the first-stage turbine vane. The use of coal derived syngas fuels provides an additional challenge to the lifetime of materials utilized in the turbine, as particulate byproducts created in the coal gasification process melt in the combustion gas, and can subsequently deposit and interact with the turbine hardware. The development of durable hot-section materials capable of operating at temperature well above that of single crystal superalloy airfoil/zirconia based thermal barrier coatings is critical to realizing 65% efficient coal derived syngas fired gas turbine based power systems. To enable higher turbine inlet temperatures while lowering cooling air requirements, United Technologies Research Center (UTRC), the central R&D laboratory supporting UT Pratt & Whitney, led the conceptual design of a new type of ceramic composite turbine hot section materials system. The design focused on a novel hybrid monolithic ceramic-fiber reinforced ceramic matrix composite (CMC) first stage turbine vane having an environmental barrier coating. By utilizing ceramic construction in the turbine hot-section, the core flow normally used to cool metallic components will be substantially reduced, increasing efficiency and reducing emissions. To provide the framework for future demonstration testing, UTRC partnered with University of North Dakota Energy and Environmental Research Center (UNDEERC) to provide a conceptual design for a gasified coal fed high-pressure turbine combustor system designed to mimic the conditions expected in a future 65% fuel to busbar efficient syngas fueled gas turbine based combined cycle. The UNDEERC and UTRC collaborated on characterizing dusts from coal gasifier filtration systems.

10 SYNTHETIC FUELS↗

Multi-Split Variable Refrigerant Flow (VRF) System Building Energy Simulations Using Performance Maps

Multi-split variable refrigerant flow (VRF) systems are highly energy-efficient HVAC (heating, ventilation and air conditioning) technologies that connect a single outdoor unit to multiple independent indoor terminal units using a common refrigerant circuit and a variable-speed compressor. Building energy simulations that incorporate VRF systems help model their unique operational characteristics and predict energy consumption in specific building designs. Traditionally, EnergyPlus models these systems by employing multiple sets of performance curves to characterize both individual terminal units and the outdoor unit. However, producing these curves is labor intensive and error prone, and they often do not capture all the key input and output variables. This paper introduces a novel approach that uses multi-dimensional performance maps to model VRF systems in building environments for space cooling. In this approach, performance maps are developed at the component level—separately for the outdoor unit and for each indoor terminal. The new modeling method is validated within EnergyPlus via a Python plug-in that contains a simple solver loop to coordinate the component-level, indoor, and outdoor unit maps. Furthermore, because performance maps can span more variables than traditional performance curves, they offer the opportunity to implement advanced controls, such as enhanced dehumidification and compressor modulation. A VRF air conditioner’s hardware system was modeled using the DOE/ORNL Heat Pump Design Model, which was automated to produce extensive performance maps for both the indoor and outdoor units.

Shen, Bo [ORNL] (ORCID:0000000336600393)↗

Development of a self-lubricating high-efficiency hybrid seal composed of carbon nanotube-coated metal meshes for CSP turbomachinery (SETO CPS #36333 Final Report)

In turbomachinery, internal leakage flow accounts for up to 3% of the total thermodynamic cycle energy loss. Tradeoff must be made between the sealing efficiency (smaller clearance) and the friction and wear issues for interfering with the shaft (larger clearance). This ORNL-Danfoss joint effort developed a novel hybrid seal composed of carbon nanotube (CNT)-coated metal meshes. The CNT growth process was based on a self-catalyzing chemical vapor deposition and these multiwall CNTs were well aligned with high crystallinity. This hybrid material structure takes advantage of the CNT’s low-friction nature and uses the metal mesh as an extendable backbone. Full-scale experimental seals were designed, fabricated, and optimized for sealing performance and durability. The CNT-coated metal mesh seal demonstrated superior gas sealing efficiency to the baseline labyrinth seal and significantly improved shaft surface protection compared with the state-of-the-art superalloy brush seal on the static rig and full-scale compressor dynamometer tests. The CNT-metal mesh seal is low-cost and scalable and can potentially benefit wide applications, including CSP and other power generation, marine, automotive, and HVAC.

36 MATERIALS SCIENCE↗

An Update on the Status of a Reduced Flow Test of a 10MW 700°C sCO2 Integrally Geared Compander

. In order to maintain viability as a future power-generating technology, concentrating solar power (CSP) must reduce its levelized cost of electricity (LCOE). One component of solving this problem is reducing the cost of the power block while simultaneously increasing the efficiency of the thermodynamic cycle. One disruptive technology that has the promise to accomplish this is supercritical CO2 based power cycles. These cycles are conceptually similar to steam cycles; however, they have substantially smaller turbomachinery at equivalent power while also delivering more efficiency at turbine inlet temperatures of 500-700 degrees Celsius. This paper will summarize the current status of a US Department of Energy project to develop machinery to support a 10 MW sCO2 power cycle. The team of Southwest Research Institute® (SwRI®) and Hanwha Power Systems America, proposed to develop an integrally-geared (IG) compressor-expander (compander) for use in a nominal 10 MW-scale concentrated solar power (CSP) supercritical carbon dioxide (sCO2) plant application. This integrally-geared compander (IGC) comprises multiple pinion shafts interconnected on a single bull gear to create a compact package, and utilizes a low-cost, low-speed driver. In addition, the integrally geared architecture allows each pinion to operate at different rotational speeds to optimize performance and easily allow for inter-stage cooling and turbine re-heat to further enhance both stage and cycle efficiency. The close integration of all turbomachinery elements into a single integrally-geared (IG) machine creates a design that lends itself to power block modularization, which makes it suitable for waste heat recovery, fossil fuel power plants, and especially CSP applications. As part of the commercialization of this technology, it is necessary to reduce risk by validation testing of key components. In the current work, the focus is developing a test loop to enable safe testing of the main compressor stage across a wide range of operating conditions, and to validate the mechanical integrity of the turbine at full pressure, temperature, and speed. Developing a test loop for sCO2 requires balancing a number of design alternatives that impact cost, lead time, safety, and performance. The current work discusses the design process for the reduced flow test loop for the compander, and supporting documentation supporting the viability of the test loop

wilkes, jason↗

Thermo-economic analysis of a solid oxide fuel cell-gas turbine hybrid with commercial off-the-shelf gas turbine

The thermodynamic and economic performance of a natural gas-fueled solid oxide fuel cell (SOFC)-gas turbine (GT) hybrid system with a commercial off-the-shelf GT is investigated. Until today, commercial GTs are primarily engineered for the direct use of energy dense fuels, such as natural gas, and the integration of commercial GTs into a SOFC-GT hybrid remains challenging. In this work technically feasible and economically viable GT operating modes are identified to gauge the technology’s competitiveness on the free market. Steady state, full load operating conditions were established for various GT operating modes: I) constant spool speed operation, II) variable spool speed operation and III) partially closed compressor inlet guide vanes. For each GT operating mode, the performance was investigated over a range of SOFC fuel utilization factors, while considering physical constraints inside the SOFC, such as local temperature gradients in flow direction as well as overall cell temperature differences. The results of the thermodynamic evaluation served as inputs for the economic analysis of the SOFC-GT hybrid power plant. The results show that the integration of an off-the-shelf GT not only results in a significant derating of the GT, but also substantially impacts the SOFC operation, the main power producer in this SOFC-GT hybrid. To maximize the SOFC power output it is desirable operate the GT in a region of high air mass flow rates and low pressure ratios, which increases the number of stacks that can be accommodated and reduces the SOFC cooling requirement. The lowest costs of electricity are obtained at constant spool speed operation, while the highest efficiencies are reached at variable spool speed operation. Critical for the integration of off-the-shelf GTs, which historically have been designed for natural gas, is the surge margin. The largest surge margins are obtained by closing the compressor inlet guide vanes. Furthermore, higher SOFC fuel utilization factors are shown to increase the surge margin as the turbine firing temperature is decreased.

25 ENERGY STORAGE↗

Building Automation

In this chapter, we focus on both need-based and vision-based control innovation for building automation for HVAC systems. After providing a brief background that describes different HVAC architectures and products, we describe the control challenges and opportunities from a needs-based point of view, at the equipment level, the systems level, and the building level. At the equipment level, increased use of continuously variable actuation such as variable speed compressors and fans, requires application of robust multivariable control that must consider various types of nonlinear behavior across increasingly larger operating envelopes. The objective at this level is to achieve robust and energy efficient operation. At the system level, coupled and interactive dynamics among subsystems are increasingly important to consider, and functional integration of these subsystems, along with set points and operating schedules are designed to minimize energy consumption and improve occupant comfort. At the building level, issues such as integration among other building systems, such as the building envelope and the electric grid, offer opportunities to develop new types of demand response and grid-interactive behaviors and technologies. At the higher levels, system dynamics and robust stability are less of an issue, similar to process control applications, while optimization and integration are more important, although dynamic stability is increasing an issue at the higher levels too. From a vision-driven innovation point of view, we describe three areas that will require sustained research efforts and will eventually impact building automation: Digital Twins, Model Predictive Control, and Grid Interactive Buildings.

Bortoff, Scott↗

AN UPDATE ON THE STATUS OF A REDUCED FLOW TEST OF A 10MW 700⁰C SCO2 INTEGRALLY GEARED COMPANDER

In order to maintain viability as a future power-generating technology, concentrating solar power (CSP) must reduce its levelized cost of electricity (LCOE). One component of solving this problem is reducing the cost of the power block while simultaneously increasing the efficiency of the thermodynamic cycle. One disruptive technology that has the promise to accomplish this is supercritical CO2 based power cycles. These cycles are conceptually similar to steam cycles; however, they have substantially smaller turbomachinery at equivalent power while also delivering more efficiency at turbine inlet temperatures of 500-700℃. This paper will summarize the current status of a US Department of Energy project to develop machinery to support a 10 MW sCO2 power cycle. The team of Southwest Research Institute® (SwRI®) and Hanwha Power Systems America, proposed to develop an integrally-geared (IG) compressor-expander (compander) for use in a nominal 10 MW-scale CSP supercritical carbon dioxide (sCO2) plant application. This integrally-geared compander (IGC) comprises multiple pinion shafts interconnected on a single bull gear to create a compact package, and utilizes a low-cost, low-speed driver. In addition, the integrally-geared architecture allows each pinion to operate at different rotational speeds to optimize performance and easily allow for inter-stage cooling and turbine re-heat to further enhance both stage and cycle efficiency. The close integration of all turbomachinery elements into a single integrally-geared (IG) machine creates a design that lends itself to power block modularization, which makes it suitable for waste heat recovery, fossil fuel power plants, and especially CSP applications.

14 SOLAR ENERGY↗

Scaling considerations for supercritical carbon dioxide cycles including turbomachinery loss models

A modeling framework for the supercritical carbon dioxide recompressed closed Brayton cycle was developed. Unlike typical models, this effort incorporated generalized empirical turbomachinery loss models. Aerodynamic, windage, and leakage losses were considered in order to address the limitations of conventional constant-efficiency turbomachinery assumptions without relying on machine-specific or computationally expensive simulations. The model enables system-level exploration of optimal cycle design across a range of power scales, including smaller scales that are relevant to microreactors and extraterrestrial power applications. Parametric studies and multi-objective optimizations are used to evaluate the trade-offs between thermal efficiency and system compactness based on an analytical heat exchanger scaling model, yielding Pareto-optimal fronts across a range of operating pressures. Results reveal that at small power scales, the Pareto-optimal compressor inlet pressure becomes subcritical due to the increasing influence of density-dependent turbomachinery losses. Here, the relative contributions of each loss mechanism are quantified, and design recommendations are provided for key parameters such as recompression split ratio and generator cavity pressure across varying power scales.

Multi-objective optimization↗

Can section 45Q tax credit foster decarbonization? A case study of geologic carbon storage at Acid Gas Injection wells in the Permian Basin

Carbon capture, utilization, and storage (CCUS) is an important pathway for meeting climate mitigation goals. While the economic viability of CCUS is well understood, previous studies do not evaluate the economic feasibility of carbon capture and storage (CCS) in the Permian Basin specifically regarding the new Section 45Q tax credits. We developed a technoeconomic analysis method, evaluated the economic feasibility of CCS at the acid gas injection (AGI) wells, and assessed the implication of Section 45Q tax credits for CCS at the AGIs. We find that the compressors, well depth, and the permit and monitoring costs drive the facility costs. Compressors are the predominant contributors to capital and operating expenditure driving the levelized cost of CO 2 storage. Strategic cost reduction measures identified include 1) sourcing of low-cost electricity and 2) optimizing operational efficiency in well operations. In evaluating the impact of the tax credits on CCS projects, facility scale proved decisive. We found that facilities with an annual injection rate exceeding 10,000 MT storage capacity demonstrate economic viability contingent upon the procurement of inputs at the least cost. The new construction of AGI wells were found to be economically viable at a storage capacity of 100,000 MT. The basin is heavily focused on CCUS (tax credit – $\$$65/MT CO 2 ), which overshadows CCS ($\$$85/MT CO 2 ) opportunities. Balancing the dual objectives of CCS and CCUS requires planning and coordination for optimal resource and pore space utilization to attain the basin's decarbonization potential. We also found that CCS on AGI is a lower cost CCS option as compared to CCS on other industries.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Multi-physics Modeling of Radiative Heat Transfer and Fluid Flow for the Reactor Cavity Cooling System

High-temperature gas-cooled reactors (HTGRs) are notable for their high thermal efficiency and potential for combined heat and power applications. These reactors are particularly appealing due to their advanced passive safety features. HTGRs utilize passive safety systems that function without requiring active components like pumps or compressors during emergencies. These reactor designs depend on a Reactor Cavity Cooling System (RCCS) to manage decay heat removal from the reactor pressure vessel (RPV) during accident conditions. The RCCS consists of vertical rectangular channels known as "risers" or riser ducts positioned around the RPV. These risers receive heat from the RPV through both convective and radiative heat transfer mechanisms. Understanding the interplay of multiple physical phenomena, such as fluid dynamics, heat transfer, and neutron interactions, is essential for the effective design and operation of nuclear reactors, particularly for systems like the RCCS. Multi-physics simulations provide a comprehensive approach to studying these interactions, offering detailed insights and enhancing accuracy. They are especially important in RCCS designs, where the interaction between radiative and convective heat transfer can significantly impact system performance. By leveraging multi-physics simulations, complex reactor behaviors can be modeled without compromising the fidelity of the underlying physical processes. This work aims to establish a robust methodology for coupling multiple physical processes in an air-cooled RCCS. By focusing on validating this multi-physics approach, the study involves designing test cases that simulate various conditions to verify the numerical models employed. The outcomes of this research will provide critical insights for accurately modeling and optimizing complex nuclear systems like the RCCS.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗