Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMPARISON SOFTWARE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Point-Mass Aircraft Trajectory Prediction Using a Hierarchical, Highly-Adaptable Software Design

A highly adaptable and extensible method for predicting four-dimensional trajectories of civil aircraft has been developed. This method, Behavior-Based Trajectory Prediction, is based on taxonomic concepts developed for the description and comparison of trajectory prediction software. A hierarchical approach to the "behavioral" layer of a point-mass model of aircraft flight, a clear separation between the "behavioral" and "mathematical" layers of the model, and an abstraction of the methods of integrating differential equations in the "mathematical" layer have been demonstrated to support aircraft models of different types (in particular, turbojet vs. turboprop aircraft) using performance models at different levels of detail and in different formats, and promise to be easily extensible to other aircraft types and sources of data. The resulting trajectories predict location, altitude, lateral and vertical speeds, and fuel consumption along the flight path of the subject aircraft accurately and quickly, accounting for local conditions of wind and outside air temperature. The Behavior-Based Trajectory Prediction concept was implemented in NASA's Traffic Aware Planner (TAP) flight-optimizing cockpit software application.

Karr, David A.↗

Improving the Automatic Inversion of Digital Alouette/ISIS Ionogram Reflection Traces into Topside Electron Density Profiles

The topside sounders of the International Satellites for Ionospheric Studies (ISIS) program were designed as analog systems. The resulting ionograms were displayed on 35 mm film for analysis by visual inspection. Each of these satellites, launched between 1962 and 1971, produced data for 10 to 20 years. A number of the original telemetry tapes from this large data set have been converted directly into digital records. Software, known as the Topside Ionogram Scalar With True-Height (TOPIST) algorithm, has been produced and used for the automatic inversion of the ionogram reflection traces on more than 100,000 ISIS-2 digital topside ionograms into topside vertical electron density profiles Ne(h). Here we present some topside ionospheric solar cycle variations deduced from the TOPIST database to illustrate the scientific benefit of improving and expanding the topside ionospheric Ne(h) database. The profile improvements will be based on improvements in the TOPIST software motivated by direct comparisons between TOPIST profiles and profiles produced by manual scaling in the early days of the ISIS program. The database expansion will be based on new software designed to overcome limitations in the original digital topside ionogram database caused by difficulties encountered during the analog-to-digital conversion process in the detection of the ionogram frame sync pulse and/or the frequency markers. This improved and expanded TOPIST topside Ne(h) database will greatly enhance investigations into both short- and long-term ionospheric changes, e.g., the observed topside ionospheric responses to magnetic storms, induced by interplanetary magnetic clouds, and solar cycle variations, respectively.

Benson, Robert F.↗

Hologic QDR 2000 whole-body scans: a comparison of three combinations of scan modes and analysis software

This study reports on the short-term in vivo precision and absolute measurements of three combinations of whole-body scan modes and analysis software using a Hologic QDR 2000 dual-energy X-ray densitometer. A group of 21 normal, healthy volunteers (11 male and 10 female) were scanned six times, receiving one pencil-beam and one array whole-body scan on three occasions approximately 1 week apart. The following combinations of scan modes and analysis software were used: pencil-beam scans analyzed with Hologic's standard whole-body software (PB scans); the same pencil-beam analyzed with Hologic's newer "enhanced" software (EPB scans); and array scans analyzed with the enhanced software (EA scans). Precision values (% coefficient of variation, %CV) were calculated for whole-body and regional bone mineral content (BMC), bone mineral density (BMD), fat mass, lean mass, %fat and total mass. In general, there was no significant difference among the three scan types with respect to short-term precision of BMD and only slight differences in the precision of BMC. Precision of BMC and BMD for all three scan types was excellent: < 1% CV for whole-body values, with most regional values in the 1%-2% range. Pencil-beam scans demonstrated significantly better soft tissue precision than did array scans. Precision errors for whole-body lean mass were: 0.9% (PB), 1.1% (EPB) and 1.9% (EA). Precision errors for whole-body fat mass were: 1.7% (PB), 2.4% (EPB) and 5.6% (EA). EPB precision errors were slightly higher than PB precision errors for lean, fat and %fat measurements of all regions except the head, although these differences were significant only for the fat and % fat of the arms and legs. In addition EPB precision values exhibited greater individual variability than PB precision values. Finally, absolute values of bone and soft tissue were compared among the three combinations of scan and analysis modes. BMC, BMD, fat mass, %fat and lean mass were significantly different between PB scans and either of the EPB or EA scans. Differences were as large as 20%-25% for certain regional fat and BMD measurements. Additional work may be needed to examine the relative accuracy of the scan mode/software combinations and to identify reasons for the differences in soft tissue precision with the array whole-body scan mode.

NASA Discipline Musculoskeletal↗

SU-F-T-302: Implementation of the RadCalc Image Analysis Tool for IMRT QA

Purpose: To assess RadCalc as a means for analyzing fluence maps of IMRT QA patient plans. Eclipse generated fluence maps were compared to RadCalc fluence maps generated from both Eclipse parameters and from dynalog trajectory files. Methods: Six IMRT plans consisting of fifty individual fields were compared both field-by-field and as composite plans. These plans were exported from Eclipse to RadCalc. Each plan was then delivered in QA mode on a Varian Clinac iX, while recording and saving the dynalog trajectory files. These files were then imported into RadCalc, providing three sources of generating fluence maps: Eclipse, RadCalc, and dynalog files. Using the image analysis tool in RadCalc, a gamma analysis was then performed as a point-by-point comparison for each IMRT field. The Eclipse fluence map was used as the baseline for each comparison. Results: Based on the manufacturer’s recommendations, all fields were normalized to the maximum pixel value within each Eclipse field. All data was analyzed using a gamma index of 3mm/3% with passing criteria of 90%. For both dynalog analysis and RadCalc fluence analysis, 48/50 created fluence maps passed at greater than 90% when compared with the Eclipse baseline. In analyzing the composite of each of the six patients’ plans, all plans passed over 90%. Conclusion: Using the dynalog trajectory files in combination with RadCalc Version 6.3 image analysis is a promising metric for verifying IMRT QA passing rates. Notably, if a field failed, it did so for both dynalog and RadCalc compared to Eclipse. This suggests RadCalc can accurately simulate fluence maps, with similar results to dynalog comparisons. Limitations within the RadCalc software were discovered in the analytical process such as pixel resolution and the inability to set minimum threshold values. Comparisons could be extended to include dose map and distance to agreement analysis by expanding software capabilities.

60 APPLIED LIFE SCIENCES↗

RDV77 VLBA Hardware/Software Correlator Comparisons

Results of a hardware vs. software correlation of the RDV77 session are presented. Group delays are found to agree (WRMS differences) at an average level of 4.2 psec and with a noise floor of 2.5 psec. These RDV77 comparisons agree well with several previous correlator comparison studies.

Gordon, David↗

Implementation of J-A Methodology Elastic-Plastic Crack Instability Analysis Capability into the WARP-3D Code

Characterization of the near crack-tip stress/strain fields is the foundation of fracture mechanics. The description of the near tip stress field and the prediction of when fracture occurs is well established for brittle materials that exhibit linear elastic behavior. However, in ductile materials or conditions that violate linear elastic assumptions (Aluminum alloys, Al 2024-T3, Al 2024- T351 etc.), the elastic-plastic crack-tip stress fields are characterized by the Hutchison-Rice-Rosengren (HRR) field. The J-integral is commonly used to characterize amplitude of the HRR field under elastic-plastic conditions. The J-integral has been demonstrated for crack-tip fields that are under high constraint conditions (i.e., small-scale plasticity where the J-dominance is maintained). However, as the external load increases, yielding changes from small- to largescale plasticity and usually a loss of constraint (i.e., reduction in the triaxial stress field along the crack front). The loss of constraint leads to the deviation of the crack-tip stress fields from that given by the HRR field. Hence, the J-dominance will be gradually lost and additional parameter(s) are required to quantify the crack-tip stress fields and predict fracture behavior. The assessment objectives were to: 1) implement a two-parameter (i.e., J-A) fracture criterion into an elastic-plastic three-dimensional (3D) finite element analysis (FEA), 2) validate the implementation by comparison with the A parameter from literature data, 3) conduct material characterization tests to quantify the material behavior and provide fracture data for validation of the J-A fracture criteria, and (4) perform evaluations to establish if the J-A criteria can be used to predict fracture in a ductile metallic material (e.g., aluminum alloys). The A parameter in these criteria is the second parameter in a three-term elastic-plastic asymptotic expansion of the neartip stress behavior. A series of extensive FEAs were performed using WARP3D software package to obtain solutions for the A parameter for different specimen configurations. The methodology needed for the estimation of the A parameter in the asymptotic expansion was developed and implemented using Matlab®. A user material (UMAT) routine was used to model the material stress-strain response using a Ramberg-Osgood power law with a hardening exponent (n) and a material coefficient (alpha). This UMAT routine was successfully implemented in WARP3D software and validated through comparison with the experimental data. Three configurations were extracted from published results: 1) center cracked plate (CCP), 2) single edge-cracked plate (SECP), and 3) double edge-cracked plate (DECP). These configurations and four other configurations (three-hole tension (THT)), three-point bend (3PTB), three-hole compact tension (3PCT), and compact tension (CT)) were analyzed to verify the methodology that was developed and implemented into WARP3D. Solutions of the A parameter were obtained for remote tension loading conditions that started with small-scale yielding and continued into the large-scale plasticity regime. The results indicate that the methodology developed can be used to calculate the elastic-plastic J-A parameters for test specimens with a range of crack geometries, material strain hardening behaviors, and loading conditions. The J-A parameters were implemented as fracture criteria and used to predict the test results. For comparison, other fracture criteria were used to predict the same test results. Major findings include: The A constraint parameter A varies with specimen type and applied load thus accurate determination is crucial in predicting the failure load, and the A parameter is asymptotic as the failure load is approached, making an accurate determination difficult (i.e., small differences in the A parameter can cause large variations in failure load) for materials exhibiting elastic-plastic behavior. The failure predictions from J-A methodology were more accurate than the traditionally used KC and J methods, and have comparable scatter to that observed when using the crack-tip opening angle (CTOA) method. However, the J-A methodology requires considerable effort (expertise level and labor) to implement and to evaluate the A parameter for different specimen types and materials, or to apply this methodology to part-through crack (e.g., 3D problems) structural applications.

Hamm, Kenneth R., Jr.↗

SU-E-T-277: Dose Calculation Comparisons Between Monaco, Pinnacle and Eclipse Treatment Planning Systems

Purpose: Monaco treatment planning system (TPS) version 5.0 uses a Monte-Carlo based dose calculation engine. The aim of this study is to verify and compare the Monaco based dose calculations with both Pinnacle{sup 3} collapsed cone convolution superposition (CCC) and Eclipse analytical anisotropic algorithm (AAA) calculations. Methods: For this study, previously treated SBRT lung, head and neck and abdomen patients were chosen to compare dose calculations between Pinnacle, Monaco and Eclipse. Plans were chosen from those that had been treated using the Elekta VersaHD or a NovalisTX linac. The plans included 3D conventional and IMRT beams using 6MV and 6MV Flattening filter free (FFF) photon beams. The original plans calculated with CCCS or AAA along with the recalculated ones using MC from the three TPS were exported into Velocity software for inter-comparison. Results: To compare the dose calculations, Mean Lung Dose (MLD), lung V5 and V20 values, and PTV Heterogeneity indexes (HI) and Conformity indexes (CI) were all calculated and recorded from the dose volume histograms (DVH). For each patient, the CI values were identical but there were differences in all other parameters. The HI was computed higher by 5 and 4% for calculated plans AAA and CCCS respectively, compared to the MC ones. The DVH graphs showed large differences between the CCCS and AAA and Monaco for 3D FFF, VMAT and IMRT plans. Better DVH agreement between was observed for 3D conventional plans. Conclusion: Better agreement was observed between CCCS and MC calculations than AAA and MC calculations. Those differences were more profound as the field size was decreasing and in the presence of inhomogeneities.

60 APPLIED LIFE SCIENCES↗

RhizoVision Explorer: open-source software for root image analysis and measurement standardization

Abstract Roots are central to the function of natural and agricultural ecosystems by driving plant acquisition of soil resources and influencing the carbon cycle. Root characteristics like length, diameter and volume are critical to measure to understand plant and soil functions. RhizoVision Explorer is an open-source software designed to enable researchers interested in roots by providing an easy-to-use interface, fast image processing and reliable measurements. The default broken roots mode is intended for roots sampled from pots and soil cores, washed and typically scanned on a flatbed scanner, and provides measurements like length, diameter and volume. The optional whole root mode for complete root systems or root crowns provides additional measurements such as angles, root depth and convex hull. Both modes support providing measurements grouped by defined diameter ranges, the inclusion of multiple regions of interest and batch analysis. RhizoVision Explorer was successfully validated against ground truth data using a new copper wire image set. In comparison, the current reference software, the commercial WinRhizo™, drastically underestimated volume when wires of different diameters were in the same image. Additionally, measurements were compared with WinRhizo™ and IJ_Rhizo using a simulated root image set, showing general agreement in software measurements, except for root volume. Finally, scanned root image sets acquired in different labs for the crop, herbaceous and tree species were used to compare results from RhizoVision Explorer with WinRhizo™. The two software showed general agreement, except that WinRhizo™ substantially underestimated root volume relative to RhizoVision Explorer. In the current context of rapidly growing interest in root science, RhizoVision Explorer intends to become a reference software, improve the overall accuracy and replicability of root trait measurements and provide a foundation for collaborative improvement and reliable access to all.

59 BASIC BIOLOGICAL SCIENCES↗

Integrated Optical Design Analysis (IODA): New Test Data and Modeling Features

A general overview of the capabilities of the IODA ("Integrated Optical Design Analysis") exchange of data and modeling results between thermal, structures, optical design, and testing engineering disciplines. This presentation focuses on new features added to the software that allow measured test data to be imported into the IODA environment for post processing or comparisons with pretest model predictions. software is presented. IODA promotes efficient

Moore, Jim↗

Transcript and blood-microbiome analysis towards a blood diagnostic tool for goats affected by Haemonchus contortus

The Alpine goat (Capra aegagrus hircus) is parasitized by the barber pole worm (Haemonchus contortus). Hematological parameters from transcript and metagenome analysis in the host are reflective of infestation. We explored comparisons between blood samples of control, infected, infected zoledronic acid-treated, and infected antibody (anti-γδ T cells) treated wethers under controlled conditions. Seven days post-inoculation (dpi), we identified 7,627 transcripts associated with the different treatment types. Microbiome measurements at 7 dpi revealed fewer raw read counts across all treatments and a less diverse microbial flora than at 21 dpi. This study identifies treatment specific transcripts and an increase in microflora abundance and diversity as wethers age. Further, F/B ratio reflect health, based on depression or elevation above thresholds defined by the baseline of non-infected controls. Forty Alpine wethers were studied where blood samples were collected from five goats in four treatment groups on 7 dpi and 21 dpi. Transcript and microbiome profiles were obtained using the Partek Flow (St. Louis, Missouri, USA) software suites pipelines. Inflammation comparisons were based on the Firmicutes/Bacteriodetes ratios that are calculated as well as the reduction of microbial diversity.

60 APPLIED LIFE SCIENCES↗

Clinical experience transitioning from IMRT to VMAT for head and neck cancer

To quantify clinical differences for volumetric modulated arc therapy (VMAT) versus intensity modulated radiation therapy (IMRT) in terms of dosimetric endpoints and planning and delivery time, twenty head and neck cancer patients have been considered for VMAT using Nucletron Oncentra MasterPlan delivered via an Elekta linear accelerator. Differences in planning time between IMRT and VMAT were estimated accounting for both optimization and calculation. The average delivery time per patient was obtained retrospectively using the record and verify software. For the dosimetric comparison, all contoured organs at risk (OARs) and planning target volumes (PTVs) were evaluated. Of the 20 cases considered, 14 had VMAT plans approved. Six VMAT plans were rejected due to unacceptable dose to OARs. In terms of optimization time, there was minimal difference between the two modalities. The dose calculation time was significantly longer for VMAT, 4 minutes per 358 degree arc versus 2 minutes for an entire IMRT plan. The overall delivery time was reduced by 9.2 ± 3.9 minutes for VMAT (51.4 ± 15.6%). For the dosimetric comparison of the 14 clinically acceptable plans, there was almost no statistical difference between the VMAT and IMRT. There was also a reduction in monitor units of approximately 32% from IMRT to VMAT with both modalities demonstrating comparable quality assurance results. VMAT provides comparable coverage of target volumes while sparing OARs for the majority of head and neck cases. In cases where high dose modulation was required for OARs, a clinically acceptable plan was only achievable with IMRT. Due to the long calculation times, VMAT plans can cause delays during planning but marked improvements in delivery time reduce patient treatment times and the risk of intra-fraction motion.

61 RADIATION PROTECTION AND DOSIMETRY↗

MULTI-SCALE CLEAN: A COMPARISON OF ITS PERFORMANCE AGAINST CLASSICAL CLEAN ON GALAXIES USING THINGS

A practical evaluation of the multi-scale CLEAN algorithm is presented. The data used in the comparisons are taken from The H I Nearby Galaxy Survey. The implementation of multi-scale CLEAN in the CASA software package is used, although comparisons are made against the very similar multi-resolution CLEAN algorithm implemented in AIPS. Both are compared against the classical CLEAN algorithm (as implemented in AIPS). The results of this comparison show that several of the well-known characteristics and issues of using classical CLEAN are significantly lessened (or eliminated completely) when using the multi-scale CLEAN algorithm. Importantly, multi-scale CLEAN significantly reduces the effects of the clean 'bowl' that is caused by missing short-spacings, and the 'pedestal' of low-level un-cleaned flux (which affects flux scales and resolution). Multi-scale CLEAN can clean down to the noise level without the divergence suffered by classical CLEAN. We discuss practical applications of the added contrast provided by multi-scale CLEAN using two selected astronomical examples: H I holes in the interstellar medium and anomalous gas structures outside the main galactic disk.

79 ASTRONOMY AND ASTROPHYSICS↗

A pencil beam algorithm for helium ion beam therapy

Purpose: To develop a flexible pencil beam algorithm for helium ion beam therapy. Dose distributions were calculated using the newly developed pencil beam algorithm and validated using Monte Carlo (MC) methods. Methods: The algorithm was based on the established theory of fluence weighted elemental pencil beam (PB) kernels. Using a new real-time splitting approach, a minimization routine selects the optimal shape for each sub-beam. Dose depositions along the beam path were determined using a look-up table (LUT). Data for LUT generation were derived from MC simulations in water using GATE 6.1. For materials other than water, dose depositions were calculated by the algorithm using water-equivalent depth scaling. Lateral beam spreading caused by multiple scattering has been accounted for by implementing a non-local scattering formula developed by Gottschalk. A new nuclear correction was modelled using a Voigt function and implemented by a LUT approach. Validation simulations have been performed using a phantom filled with homogeneous materials or heterogeneous slabs of up to 3 cm. The beams were incident perpendicular to the phantoms surface with initial particle energies ranging from 50 to 250 MeV/A with a total number of 10{sup 7} ions per beam. For comparison a special evaluation software was developed calculating the gamma indices for dose distributions. Results: In homogeneous phantoms, maximum range deviations between PB and MC of less than 1.1% and differences in the width of the distal energy falloff of the Bragg-Peak from 80% to 20% of less than 0.1 mm were found. Heterogeneous phantoms using layered slabs satisfied a {gamma}-index criterion of 2%/2mm of the local value except for some single voxels. For more complex phantoms using laterally arranged bone-air slabs, the {gamma}-index criterion was exceeded in some areas giving a maximum {gamma}-index of 1.75 and 4.9% of the voxels showed {gamma}-index values larger than one. The calculation precision of the presented algorithm was considered to be sufficient for clinical practice. Although only data for helium beams was presented, the performance of the pencil beam algorithm for proton beams was comparable. Conclusions: The pencil beam algorithm developed for helium ions presents a suitable tool for dose calculations. Its calculation speed was evaluated to be similar to other published pencil beam algorithms. The flexible design allows easy customization of measured depth-dose distributions and use of varying beam profiles, thus making it a promising candidate for integration into future treatment planning systems. Current work in progress deals with RBE effects of helium ions to complete the model.

60 APPLIED LIFE SCIENCES↗

SU-E-T-570: New Quality Assurance Method Using Motion Tracking for 6D Robotic Couches

Purpose: To accommodate geometrically accurate patient positioning, a robotic couch that is capable of 6-degrees of freedom has been introduced. However, conventional couch QA methods are not sufficient to enable the necessary accuracy of tests. Therefore, we have developed a camera based motion detection and geometry calibration system for couch QA. Methods: Employing a Visual-Tracking System (VTS, BonitaB10, Vicon, UK) which tracks infrared reflective(IR) markers, camera calibration was conducted using a 5.7 × 5.7 × 5.7 cm{sup 3} cube attached with IR markers at each corner. After positioning a robotic-couch at the origin with the cube on the table top, 3D coordinates of the cube’s eight corners were acquired by VTS in the VTS coordinate system. Next, positions in reference coordinates (roomcoordinates) were assigned using the known relation between each point. Finally, camera calibration was completed by finding a transformation matrix between VTS and reference coordinate systems and by applying a pseudo inverse matrix method. After the calibration, the accuracy of linear and rotational motions as well as couch sagging could be measured by analyzing the continuously acquired data of the cube while the couch moves to a designated position. Accuracy of the developed software was verified through comparison with measurement data when using a Laser tracker (FARO, Lake Mary, USA) for a robotic-couch installed for proton therapy. Results: VTS system could track couch motion accurately and measured position in room-coordinates. The VTS measurements and Laser tracker data agreed within 1% of difference for linear and rotational motions. Also because the program analyzes motion in 3-Dimension, it can compute couch sagging. Conclusion: Developed QA system provides submillimeter/ degree accuracy which fulfills the high-end couch QA. This work was supported by the National Research Foundation of Korea funded by Ministry of Science, ICT & Future Planning. (2013M2A2A7043507 and 2012M3A9B6055201)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-391: Comparative Study of Treatment Planning Between IMRT and IMAT for Malignant Pleural Mesothelioma

Purpose: The purpose of this study was to compare the dosimetric differences between intensitymodulated radiation therapy (IMRT) and intensity modulated arc therapy (IMAT) for malignant pleural mesothelioma (MPM) patients with regard to the sparing effect on organs at risk (OARs), plan quality, and delivery efficiency. Methods: Ten MPM patients were recruited in this study. To avoid the inter-operator variability, IMRT and IMAT plans for each patient were performed by one experienced dosimetrist. The treatment planning optimization process was carried out using the Eclipse 13.0 software. For a fair comparison, the planning target volume (PTV) coverage of the two plans was normalized to the same level. The treatment plans were evaluated on the following dosimetric variables: conformity index (CI) and homogeneity index (HI) for PTV, OARs dose, and the delivery efficiency for each plan. Results: All plans satisfied clinical requirements. The IMAT plans gained better CI and HI. The IMRT plans performed better sparing for heart and lung. Less MUs and control points were found in the IMAT plans. IMAT shortened delivery time compared with IMRT. Conclusion: For MPM, IMAT gains better conformity and homogeneity for PTV with IMRT, but increases the irradiation dose for OARs. IMAT shows an advantage in delivery efficiency.

60 APPLIED LIFE SCIENCES↗

GraphBench

GraphBench is a benchmark suite for graph pattern mining and graph analysis systems. The benchmark suite is a significant addition to conducting apples-apples comparison of graph analysis software (databases, in-memory tools, triple stores, etc.)

Sukumar, SreenivasR.↗

Modifications to the accuracy assessment analysis routine SPATL to produce an output file

The SPATL is an analysis program in the Accuracy Assessment Software System which makes comparisons between ground truth information and dot labeling for an individual segment. In order to facilitate the aggregation cf this information, SPATL was modified to produce a disk output file containing the necessary information about each segment.

Carnes, J. G.↗

A comparison of time-shared vs. batch development of space software

In connection with a study regarding the ground support software development for the Space Shuttle, an investigation was conducted concerning the most suitable software development techniques to be employed. A time-sharing 'trial period' was used to determine whether or not time-sharing would be a cost-effective software development technique for the Ground Based Shuttle system. It was found that time-sharing substantially improved job turnaround and programmer access to the computer for the representative group of ground support programmers. Moreover, this improvement resulted in an estimated saving of over fifty programmer days during the trial period.

Forthofer, M.↗