SU-F-BRD-09: Is It Sufficient to Use Only Low Density Tissue-Margin to Compensate Inter-Fractionation Setup Uncertainties in Lung Treatment?

Purpose: In lung radiation treatment, PTV is formed with a margin around GTV (or CTV/ITV). Although GTV is most likely of water equivalent density, the PTV margin may be formed with the surrounding low-density tissues, which may lead to unreal dosimetric plan. This study is to evaluate whether the concern of dose calculation inside the PTV with only low density margin could be justified in lung treatment. Methods: Three SBRT cases were analyzed. The PTV from the original plan (Plan-O) was created with a 5–10 mm margin outside the ITV to incorporate setup errors and all mobility from 10 respiratory phases. Test plans were generated with the GTV shifted to the PTV edge to simulate the extreme situations with maximum setup uncertainties. Two representative positions as the very posterior-superior (Plan-PS) and anterior-inferior (Plan-AI) edge were considered. The virtual GTV was assigned a density of 1.0 g.cm−3 and surrounding lung, including the PTV margin, was defined as 0.25 g.cm−3. Also, additional plan with a 1mm tissue-margin instead of full lung-margin was created to evaluate whether a composite-margin (Plan-Comp) has a better approximation for dose calculation. All plans were generated on the average CT using Analytical Anisotropic Algorithm with heterogeneity correction on and all planning parameters/monitor unites remained unchanged. DVH analyses were performed for comparisons. Results: Despite the non-static dose distribution, the high-dose region synchronized with tumor positions. This might due to scatter conditions as greater doses were absorbed in the solid-tumor than in the surrounding low-density lungtissue. However, it still showed missing target coverage in general. Certain level of composite-margin might give better approximation for the dosecalculation. Conclusion: Our exploratory results suggest that with the lungmargin only, the planning dose of PTV might overestimate the coverage of the target during treatment. The significance of this overestimation might warrant further investigation.

60 APPLIED LIFE SCIENCES↗

Sci—Fri PM: Topics — 03: The Global Task Force on Radiotherapy for Cancer Control: Core Investments

The Union for International Cancer Control (UICC) is a membership-based, non-governmental organization with a mandate to “…to unite the cancer community to reduce the global cancer burden, to promote greater equity, and to integrate cancer control into the world health and development agenda.” COMP is an associate member of the UICC. It is well recognized by the UICC that there are major gaps between high, and low and middle income countries, in terms of access to cancer services including access to radiation therapy. In this context, the UICC has developed a Global Task Force on Radiotherapy for Cancer Control with a charge to answer a single question: “What does it cost to close the gap between what exists today and reasonable access to radiotherapy globally?” The Task Force consists of leaders internationally recognized for their radiation treatment related expertise (radiation oncologists, medical physicists, radiation therapists) as well as those with global health and economics specialization. The Task Force has developed three working groups: (1) to look at the global burden of cancer; (2) to look at the infrastructure requirements (facilities, equipment, personnel); and (3) to consider outcomes in terms of numbers of lives saved and palliated patients. A report is due at the World Cancer Congress in December 2014. This presentation reviews the infrastructure considerations under analysis by the second work group. The infrastructure parameters being addressed include capital costs of buildings and equipment and operating costs, which include human resources, equipment servicing and quality control, and general overhead.

60 APPLIED LIFE SCIENCES↗

MO-DE-BRA-03: The Ottawa Medical Physics Institute (OMPI): A Practical Model for Academic Program Collaboration in a Multi-Centre City

Purpose: To build a world-class medical physics educational program that capitalizes on expertise distributed over several clinical, government, and academic centres. Few if any of these centres would have the critical mass to solely resource a program. Methods: In order to enable an academic program, stakeholders from five institutions made a proposal to Carleton University for a) a research network with defined membership requirements and a process for accepting new members, and b) a graduate specialization (MSc and PhD) in medical physics. Both proposals were accepted and the program has grown steadily. Our courses are taught by medical physicists from across the collaboration. Our students have access to physicists in: clinical radiotherapy (the Ottawa Cancer Centre treats 4500 new patients/y), radiology, cardiology and nuclear medicine, Canada’s primary standards dosimetry laboratory, radiobiology, and university-based medical physics research. Our graduate courses emphasize the foundational physics plus applied aspects of imaging, radiotherapy, and radiobiology. Active researchers in the city-wide volunteer-run network are appointed as adjunct professors by Physics, giving them access to national funding competitions and partial student funding through teaching assistantships while opening up facilities in their institutions for student thesis research. Results: The medical physics network has grown to ∼40 members from eight institutions and includes five full-time faculty in Physics and 17 adjunct research professors. The graduate student population is ∼20. Our graduates have proceeded to a spectrum of careers. Our alumni list includes a CCPM Past-President, the current COMP President, many clinical physicists, and the heads of at least three major clinical medical physics departments. Our PhD was Ontario’s first CAMPEP-accredited program. Conclusion: A self-governing volunteer network is the foundational element that enables an MSc/PhD medical physics program in a city with multiple physicist employers. It enriches graduate education with an unusually broad range of expertise.

61 RADIATION PROTECTION AND DOSIMETRY↗

Poster - 28: Shielding of X-ray Rooms in Ontario in the Absence of Best Practice

This poster will be strictly based on the Healing Arts Radiation Protection (HARP) Act, Regulation 543 under this Act (X-ray Safety Code), and personal communication the presenting author has had. In Ontario, the process of approval of an X-ray machine installation by the Director of the X-ray Inspection Service (XRIS) follows a certain protocol. Initially, the applicant submits a series of forms, including recommended shielding amounts, in order to satisfy the law. This documentation is then transferred to a third-party vendor (i.e. a professional engineer – P.Eng.) outsourced by the Ministry of Health and Long-term Care (MOHLTC). The P.Eng. then evaluates the submitted documentation for appropriate fulfillment of the HARP Act and Reg. 543 requirements. If the P.Eng.’s evaluation of the documentation is to their satisfaction, the XRIS is then notified. Finally, the Director will then issue a letter of approval to install the equipment at the facility. The methodology required to be used by the P.Eng. in order to determine the required amounts of protective barriers, and recommended to be used by the applicant, is contained within Safety Code 20A. However, Safety Code 35 has replaced the obsolete Safety Code 20A document and employs best practices in shielding design. This talk will focus further on specific intentions and limitations of Safety Code 20A. Furthermore, this talk will discuss the definition of the “practice of professional engineering” in Ontario. COMP members who are involved in shielding design are strongly encouraged to attend.

60 APPLIED LIFE SCIENCES↗

Sci-Fri AM: Quality, Safety, and Professional Issues 02: Recent work on TQC Suite and Data from a National survey on Community Uptake

The Canadian Partnership for Quality Radiotherapy (CPQR) and the Canadian Organization of Medical Physicist’s (COMP) Quality Assurance and Radiation Safety Advisory Committee (QARSAC) have worked together in the development of a suite of Technical Quality Control (TQC) Guidelines for radiation treatment equipment and technologies, that outline specific performance objectives and criteria that equipment should meet in order to assure an acceptable level of radiation treatment quality. Early community engagement and uptake survey data showed 70% of Canadian centers are part of this process and that the data in the guideline documents reflect, and are influencing the way Canadian radiation treatment centres run their technical quality control programs. As the TQC development framework matured as a cross-country initiative, guidance documents have been developed in many clinical technologies. Recently, there have been new TQC documents initiated for Gamma Knife and Cyberknife technologies where the entire communities within Canada are involved in the review process. At the same time, QARSAC reviewed the suite as a whole for the first time and it was found that some tests and tolerances overlapped across multiple documents as single tests could pertain to multiple quality control areas. The work to streamline the entire suite has allowed for improved usability of the suite while keeping the integrity of single quality control areas. The suite will be published by the JACMP, in the coming year.

60 APPLIED LIFE SCIENCES↗

Magnetic Dichroism in the Reflectivity of Linearly Polarized Synchrotron Radiation from a Ti(10 nm)/Gd{sub 0.23}Co{sub 0.77}(250 nm)/Ti(10 nm) Sample

The dichroic effect (“rotated” polarization) in the reflectivity from a magnetically ordered sample is experimentally studied at the station PHASE of the Kurchatov Synchrotron Radiation Source. The experiments are performed for the Gd{sub 0.23}Co{sub 0.77} film, which has a compensation temperature T{sub comp} ≈ 433 K, using linearly polarized radiation of the photon energy of 7930 eV (L{sub 2} absorption edge of gadolinium) at room temperature. The developed theory of reflectivity accounted for the magnetic contributions to the scattering amplitude predicts the appearance of a peak for the orthogonal (to the incident polarization) polarization of the reflected radiation near the critical angle of the total external reflection. The experiment reveals the significant difficulties because of the incomplete σ polarization of the synchrotron beam, the beam instability, and so on. Therefore, a rotated-polarization peak has been detected near the critical angle but at the limits of the measurement accuracy. In principle, our experimental technique could be an alternative to circular polarization experiments, which are widely used at synchrotrons to study magnetic ordering. However, as we have shown, it makes high demands of the radiation source parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multigrid Preconditioning of Linear Systems for Interior Point Methods Applied to a Class of Box-constrained Optimal Control Problems

We construct and analyze multigrid preconditioners for discretizations of operators of the form ${\mathcal D}_{\lambda}+{\mathcal K}^*{\mathcal K}$, where $D_{\lambda}$ is the multiplication with a relatively smooth function $\lambda>0$ and ${\mathcal K}$ is a compact linear operator. These systems arise when applying interior point methods to the minimization problem $\min_{u} \frac{1}{2}(|\!|{\mathcal K} u-f|\!|^2 +\beta|\!|u|\!|^2)$ with box-constraints $\underline{u}\leqslant u\leqslant\overline{u}$ on the controls. The presented preconditioning technique is closely related to the one developed by Draganescu and Dupont [Math. Comp., 77 (2008), pp. 2001–2038] for the associated unconstrained problem and is intended for large-scale problems. As in that work, the quality of the resulting preconditioners is shown to increase as $h\downarrow 0$, but it decreases as the smoothness of $\lambda$ declines. We test this algorithm on a Tikhonov-regularized backward parabolic equation with box-constraints on the control and on a standard elliptic-constrained optimization problem. In both cases it is shown that the number of linear iterations per optimization step, as well as the total number of finest-scale matrix-vector multiplications, is decreasing with increasing resolution, thus showing the method to be potentially very efficient for truly large-scale problems.

97 MATHEMATICS AND COMPUTING↗

ORNL_AISD_NiNb

This dataset describes the nickel-niobium solid solution binary alloy, where the two constituent elements nickel (Ni) and niobium (Nb) are randomly placed on an underlying crystal lattice. This dataset for nickel-niobium (Ni-Nb) alloys available includes the formation energy and bulk modulus for each crystal structure. Each atomic sample has a disordered phase which is obtained starting from an initial regular crystal structure of type body-centered cubic (BCC), face-centered cubic (FCC), or hexagonal compact packed (HCP). The geometry optimization ensures that all the alloy samples reached the equilibrium with negative formation energy. We perform geometry optimizations using the LAMMPS simulation package [1], a flexible simulation tool for particle-based materials modeling at the atomic, meso, and continuum scales. We utilized the embedded atom model (EAM) potential for Ni and Nb developed in a previous study [2]. The potential could describe behaviors of the liquid and solid phases of Ni-Nb alloy. The structural factors and angular distributions of three atoms are well-matched with X-ray and ab initio-based molecular dynamics data. We prepared the three different crystals with different initial lattice parameters (3.52 Ã… for FCC, 3.32 Ã… for BCC, and 3.5 Ã… for HCP). We performed energy minimization in two steps. Firstly, we minimized the structures with an isotropic unit cell to minimize the side effects from our arbitrary lattice parameters for all other compositions. Then, we applied geometry optimization with a triclinic (non-orthogonal) unit cell to fully minimize the stress components to calculate the elastic constants. In this procedure, we chose 10,000 as the maximum number of allowable steps aimed at obtaining fully relaxed atomic geometries. The dataset consists of three sets of crystal structures. The first set contains 46,086 irregular crystal structures, each of them with 54 atoms, obtained through optimization starting from a regular BCC crystal structure. The second set contains 24,543 irregular crystal structures, each of them with 32 atoms, obtained through optimization starting from a regular FCC crystal structure. The third set contains 39,303 irregular crystal structures, each of them with 48 atoms, obtained through optimization starting from a regular HCP crystal structure. The atomic configurations within each set span the possible compositional range. The three sets have been unified in a global dataset, which is extremely heterogeneous in terms of crystal structures, lattice volumes, and atomic configurations. Organization of files inside the dataset: the dataset contains three subdirectories called • BCC_opt • FCC_opt • HCP_opt based on the type of initial regular structure used to start the geometry optimization. Inside each of these folders, every atomic structure is identified by a string “A_B_Câ€, where A denotes the number of Nb in the system, B denotes index of structure with a given Nb number, and C denotes the total number of structures generated with a given Nb number. For each optimized crystal structure identified by the unique string of characters “A_B_Câ€, three files are provided: • A_B_C_opt.xyz: The optimized geometries in xyz format • A_B_C_opt.cfg: The optimized geometries in cfg format. It includes cell information and atomic energy, and forces calculated from LAMMPS. • A_B_C.elastic: Raw data of 21 elastic constants from LAMMPS output. • A_B_C.bulk: Calculated upper and lower bounds of bulk modulus and averaged one based on Voigt-Reuss-Hill approach from *.elastic. References: [1] A. P. Thompson, H. M. Aktulga, R. Berger, D. S. Bolintineanu, W. M. Brown, P. S. Crozier, P. J. in 't Veld, A. Kohlmeyer, S. G. Moore, T. D. Nguyen, R. Shan, M. J. Stevens, J. Tranchida, C. Trott, and S. J. Plimpton. LAMMPS - a flexible simulation tool for particle-based materials modeling at the atomic, meso, and continuum scales. Comp. Phys. Comm., 271:108171, 2022. [2] Y Zhang, R Ashcraft, MI Mendelev, CZ Wang, and KF Kelton. Experimental and molecular dynamics simulation study of structure of liquid and amorphous ni62nb38 alloy. The Journal of chemical physics, 145(20):204505, 2016.

36 MATERIALS SCIENCE↗

Sandia 7uPCX Critical Experiments Exploring the Effects of Fuel-to-Water Ratio Variations

The Sandia Critical Experiments (SCX) Program provides a specialized facility for performing water moderated and reflected critical experiments with UO 2 fuel rod arrays. A history of safe reactor operations and flexibility in reactor core configuration has resulted in the completion of several benchmark critical experiment evaluations that are published in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The LEUCOMP-THERM-078 and LEU-COMP-THERM-080 evaluations from the handbook provide similar cases for reference. The set of experiments described here were performed using the Seven Percent Critical Experiment (7uPCX) fuel to measure the effects of decreasing the fuel-to-water volume ratio on the critical array size. This was accomplished by using fuel loading patterns to effectively increase the pitch of the fuel arrays in the assembly. The fuel rod pitch variations provided assembly configurations that ranged from strongly undermoderated to slightly overmoderated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ten Trials at Lower Slobbovia: Searching for Repetitive Electromagnetic and Seismoacoustic Signatures in Explosions

We performed a series of ten explosion tests, each test being a single 10-kg cylinder of Comp-B with a PBXN-9 booster. Eight of the tests were placed 2 m above ground level, one was at ground level, and one was 1 m below ground in a backfilled hole. The explosions were monitored by radio antennas to detect electromagnetic emissions and seismo-acoustic instrumentation. We found that certain aspects of the radiofrequency emission regimes repeated from test to test. Some features showed a systematic variation across tests, which we interpret as the effect of each detonation on the nearby ground. The radio emissions were probably from the high-temperature detonation shock, follow-on combustion, and frictional charging of dirt entrained by the blast. The below-ground test in particular generated an anomalously-high level of RF at both low and high frequencies, presumably due to the large amount of dirt and rock involved. The seismoacoustic observations clearly discriminate the buried shot from the table and surface shots, which appear as a single population. Seismoacoustic waveforms from repeating tests at local distances have highly self-similar waveforms but amplitudes are strongly dependent on atmospheric conditions. We show that we can correct for meteorological effects on amplitude for upward-refracting atmospheres, but that correction for downward-refracting atmospheric profiles requires a coupled correction for topography.

47 OTHER INSTRUMENTATION↗

Critical Configuration and Physics Measurements for Beryllium Reflected Assemblies of U(93.15)O 2 Fuel Rods (1.506-cm Pitch)

Cadmium ratios were measured with enriched uranium metal foils at various locations in the assembly with the fuel tube at the 1.506-cm spacing. They are described in the following subsections. The experiment configuration was the same as the first critical configuration described in HEU-COMP-FAST-004 (Case 1). The experimenter placed 0.75-cm-diameter × 0.010-cm-thick 93.15%-235U-enriched uranium metal foils with and without 0.051-cm-thick cadmium covers at various locations in the core and top reflector. One part of the cadmium cover was cupshape and contained the uranium foil. The other part was a lid that fit over the exposed side of the foil when it was in the cup shaped section of the cover. As can be seen in the logbook, two runs were required to obtain all the measurements necessary for the cadmium ratio. The bare foil measurements within the top reflector were run first as part of the axial foil activation measurements. The results of this run are used for both the axial activation results and the cadmium ratios. Cadmium covered foils were then placed at the same location through the top reflector in a different run. Three pairs of bare and cadmium covered foils were also placed through the core tank. One pair was placed at the axial center of a fuel tube 11.35 cm from the center of the core. Two pairs of foils were placed on top of fuel tubes 3.02 and 12.06 cm from the center of the core. The activation of the uranium metal foils was measured after removal from the assembly using two lead shielded NaI scintillation detectors as follows. The NaI scintillators were carefully matched and had detection efficiencies for counting delayed-fission-product gamma rays with energies above 250 KeV within 5%. In all foil activation measurements, one foil at a specific location was used as a normalizing foil to remove the effects of the decay of fission products during the counting measurements with the NaI detectors. The normalization foil was placed on one NaI scintillator and the other foil on the other NaI detector and the activities measured simultaneously. The activation of a particular foil was compared to that of the normalization foil by dividing the count rate for each foil by that of the normalization foil. To correct for the differing efficiencies of the two NaI detectors, the normalization foil was counted in Detector 1 simultaneously with the foil at position x in Detector 2, and then the normalization foil was counted simultaneously in Detector 2 with the foil from position x in Counter 1. The activity of the foil from position x was divided by the activity of the normalization foil counted simultaneously. This resulted in obtaining two values of the ratio that were then averaged. This procedure essentially removed the effect of the differing efficiencies of the two NaI detectors. Differing efficiencies of 10% resulted in errors in the ratios measured to less than 1%. The background counting rates obatined with the foils used for the measurements on the NaI detectors before their irradiation measurement were subtracted from all count rates. The results of the cadmium ratio measurements are given in Table 1.3-1 and Figure 1.3-1. “No correction has been made for self shielding in the foils” (Reference 3).

1.506-cm pitch↗

IMPULSE Highlights for recent experiments at the Advanced Photon Source (2/9-2/18 2014)

This report is a presentation, with slides noting, Over 40 experiments were completed during this run using X-ray imaging on the IMPULSE system at Sector 32 IDB; Summary of new experiments: Idealized sphere compaction – Capture progression of dynamic densification through an idealized system on 0.500 mm borosilicate glass spheres (Slide 1); Detonator and EBW Imaging Experiments on IMPULSE – First time HE was intentionally detonated at APS (Slide 2); Spall and high strain rate crack nucleation/propagation in PMMA – PCI data is providing new and unique insights for model validation (Slide 3); Fiber composite for armor applications was studied under ballistic impact of Dyneema (Collaboration with Army Research Laboratory) (Slide 4). Summary of on-going experiments; Crack propagation in vitreous carbon – observed crack motion and caustic; Jet formation experiments on large grain cerium to examine phase dependent strength; Ballistic impact of Comp-B and TNT to examine thermo-mechanical response in-situ with various penetrator geometries to vary shear concentration. Other efforts: IMPULSE system moved and installed in Sector 35 (DCS). This includes the 4-frame X-ray detection system, 4- channel PDV, and other gun diagnostics; New remotely operated mobile IMPULSE structure in fabrication – to be delivered to APS in April; 4 Mini-VISAR Systems and 4-channel PDV installed in DCS instrumentation room with all associated diagnostics.

36 MATERIALS SCIENCE↗

Critical Configuration and Physics Measurements for Beryllium Reflected Assemblies of U(93.15)O 2 Fuel Rods (1.506-cm Pitch and 7-Tube Clusters)

Cadmium ratios were measured with enriched uranium metal foils at various locations in the assembly with the fuel tube at the 1.506-cm spacing. They are described in the following subsections. The experiment configuration was the same as the first critical configuration described in HEU-COMP-FAST-004 (Case 1). The experimenter placed 0.75-cm-diameter × 0.010-cm-thick 93.15%-235U-enriched uranium metal foils with and without 0.051-cm-thick cadmium covers at various locations in the core and top reflector. One part of the cadmium cover was cupshape and contained the uranium foil. The other part was a lid that fit over the exposed side of the foil when it was in the cup shaped section of the cover. As can be seen in the logbook, two runs were required to obtain all the measurements necessary for the cadmium ratio. The bare foil measurements within the top reflector were run first as part of the axial foil activation measurements. The results of this run are used for both the axial activation results and the cadmium ratios. Cadmium covered foils were then placed at the same location through the top reflector in a different run. Three pairs of bare and cadmium covered foils were also placed through the core tank. One pair was placed at the axial center of a fuel tube 11.35 cm from the center of the core. Two pairs of foils were placed on top of fuel tubes 3.02 and 12.06 cm from the center of the core. The activation of the uranium metal foils was measured after removal from the assembly using two lead shielded NaI scintillation detectors as follows. The NaI scintillators were carefully matched and had detection efficiencies for counting delayed-fission-product gamma rays with energies above 250 KeV within 5%. In all foil activation measurements, one foil at a specific location was used as a normalizing foil to remove the effects of the decay of fission products during the counting measurements with the NaI detectors. The normalization foil was placed on one NaI scintillator and the other foil on the other NaI detector and the activities measured simultaneously. The activation of a particular foil was compared to that of the normalization foil by dividing the count rate for each foil by that of the normalization foil. To correct for the differing efficiencies of the two NaI detectors, the normalization foil was counted in Detector 1 simultaneously with the foil at position x in Detector 2, and then the normalization foil was counted simultaneously in Detector 2 with the foil from position x in Counter 1. The activity of the foil from position x was divided by the activity of the normalization foil counted simultaneously. This resulted in obtaining two values of the ratio that were then averaged. This procedure essentially removed the effect of the differing efficiencies of the two NaI detectors. Differing efficiencies of 10% resulted in errors in the ratios measured to less than 1%. The background counting rates obatined with the foils used for the measurements on the NaI detectors before their irradiation measurement were subtracted from all count rates. The results of the cadmium ratio measurements are given in Table 1.3-1 and Figure 1.3-1. “No correction has been made for self shielding in the foils” (Reference 3).

reactivity worth measurements↗

Critical Configuration and Physics Measurements for Beryllium Reflected Assemblies of U(93.15) O₂ Fuel Rods (1.506-cm Pitch and 7-Tube Clusters) (Rev. 2)

Cadmium ratios were measured with enriched uranium metal foils at various locations in the assembly with the fuel tube at the 1.506-cm spacing. They are described in the following subsections. The experiment configuration was the same as the first critical configuration described in HEU-COMP-FAST-004 (Case 1). The experimenter placed 0.75-cm-diameter × 0.010-cm-thick 93.15%-235U-enriched uranium metal foils with and without 0.051-cm-thick cadmium covers at various locations in the core and top reflector. One part of the cadmium cover was cupshape and contained the uranium foil. The other part was a lid that fit over the exposed side of the foil when it was in the cup shaped section of the cover. As can be seen in the logbook, two runs were required to obtain all the measurements necessary for the cadmium ratio. The bare foil measurements within the top reflector were run first as part of the axial foil activation measurements. The results of this run are used for both the axial activation results and the cadmium ratios. Cadmium covered foils were then placed at the same location through the top reflector in a different run. Three pairs of bare and cadmium covered foils were also placed through the core tank. One pair was placed at the axial center of a fuel tube 11.35 cm from the center of the core. Two pairs of foils were placed on top of fuel tubes 3.02 and 12.06 cm from the center of the core. The activation of the uranium metal foils was measured after removal from the assembly using two lead shielded NaI scintillation detectors as follows. The NaI scintillators were carefully matched and had detection efficiencies for counting delayed-fission-product gamma rays with energies above 250 KeV within 5%. In all foil activation measurements, one foil at a specific location was used as a normalizing foil to remove the effects of the decay of fission products during the counting measurements with the NaI detectors. The normalization foil was placed on one NaI scintillator and the other foil on the other NaI detector and the activities measured simultaneously. The activation of a particular foil was compared to that of the normalization foil by dividing the count rate for each foil by that of the normalization foil. To correct for the differing efficiencies of the two NaI detectors, the normalization foil was counted in Detector 1 simultaneously with the foil at position x in Detector 2, and then the normalization foil was counted simultaneously in Detector 2 with the foil from position x in Counter 1. The activity of the foil from position x was divided by the activity of the normalization foil counted simultaneously. This resulted in obtaining two values of the ratio that were then averaged. This procedure essentially removed the effect of the differing efficiencies of the two NaI detectors. Differing efficiencies of 10% resulted in errors in the ratios measured to less than 1%. The background counting rates obatined with the foils used for the measurements on the NaI detectors before their irradiation measurement were subtracted from all count rates. The results of the cadmium ratio measurements are given in Table 1.3-1 and Figure 1.3-1. “No correction has been made for self shielding in the foils” (Reference 3).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Integral Experiment Request 209 (CED-2 Summary Report)

This report examines proposed Seven Percent Critical Experiment (7uPCX) experiments with fuel arrays larger than would be critical when fully reflected. In these experiments, the reactivity of the assembly will be controlled by varying the moderator/reflector level in the core tank. The analysis uses two configurations, each completely filling the 45x45 fuel rod array with fuel rods and water holes, as representative examples of the proposed experiments. The proposed configurations are compared to the experiments documented in LEU-COMP-THERM-078 [Reference 1] and to fully-reflected experiments with the same fully-loaded fuel arrays that are poisoned with boron in the moderator. The conclusion is drawn that the proposed experiments can be performed with acceptably low uncertainties given a calibrated moderator/reflector level measurement system.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Integral Experiment Request 206 CED-3a Summary Report

Under IER-206, the hardware for the Burnup Credit Critical Experiment will be removed from storage and placed in operation. This is the hardware we used in 2002 to perform the experiments that eventually documented in the International Handbook of Evaluated Criticality Safety Benchmark Experiments as LEU-COMP-THERM-079.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Titanium and/or Aluminum Sleeve Experiments in Fully-Reflected Water-Moderated U(4.31)O 2 Fuel Rod Lattices with 2.8 cm Pitch.

The US Department of Energy Nuclear Energy Research Initiative (NERI) funded the Bumup Credit Critical Experiment (BUCCX) at Sandia National Laboratories. The BUCCX was designed to investigate the effect of fission product materials on critical systems. The BUCCX assembly is a water-moderated and -reflected array of Zircaloy-clad triangular-pitched U(4.31)02 fuel elements. The original BUCCX experiments with rhodium are evaluated in LEU-COMP-THERM-079. In the experiments here, sets of up to 60 experiment titanium and aluminum sleeves with nominal outside diameter of 1 in (2.54 cm), wall thickness of 0.035 in (0.0889 cm), and length of 19.60 (49.784 cm) were fabricated. The sleeves are approximately the same length as the fueled section of the fuel elements and have an inner diameter that is 0.421 in (1.0693 cm) larger than the fuel elements. This allows for each sleeve to be centered around a fuel element between the grid plates within the array. Configurations differ by the number and location of sleeves. The seventeen BUCCX critical experiments reported here compare the effects of the titanium and aluminum sleeves on nearly critical fuel assembly arrays.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Preshot Report for Carbonara: Dynamics of a Boron Carbide Sandwich

The main purpose of the Carbonara experiment is to provide much-needed data to inform physics modeling of boron carbide (B 4 C) subjected to a sweeping high explosive (HE) detonation. The proposed experiment will include three separate shots, each employing a rectangular slab of HE (4” × 3” × 1”) sandwiched between two wedges of B 4 C, see Fig.1. In each case the top B 4 C wedge tapers from a height of 2.5 cm to 0.5 cm, while the bottom wedge tapers from 1.5 cm to 0.5 cm. The wedges are 4” in the direction of the proton beam, and 3” in the direction transverse to the beam. Three shots are currently planned, each one using a different HE: PBX 9501, PBX 9502, and PBX 9701. The HE will be initiated using a line wave generator (LWG) to preserve planar symmetry, in conjunction with a Comp. B booster to smooth out the profile for the initial condition on the main charge and to aid in initiation of the PBX 9502 shot. In each case the booster spans the entire length and height of the main HE slab and extends 0.5” in toward the LWG.

36 MATERIALS SCIENCE↗