Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COATINGS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

High-Temperature Oxidation-Resistant and Low Coefficient of Thermal Expansion NiAl-Base Bond Coat Developed for a Turbine Blade Application

Many critical gas turbine engine components are currently made from Ni-base superalloys that are coated with a thermal barrier coating (TBC). The TBC consists of a ZrO2-based top coat and a bond coat that is used to enhance the bonding between the superalloy substrate and the top coat. MCrAlY alloys (CoCrAlY and NiCrAlY) are currently used as bond coats and are chosen for their very good oxidation resistance. TBC life is frequently limited by the oxidation resistance of the bond coat, along with a thermal expansion mismatch between the metallic bond coat and the ceramic top coat. The aim of this investigation at the NASA Glenn Research Center was to develop a new longer life, higher temperature bond coat by improving both the oxidation resistance and the thermal expansion characteristics of the bond coat. Nickel aluminide (NiAl) has excellent high-temperature oxidation resistance and can sustain a protective Al2O3 scale to longer times and higher temperatures in comparison to MCrAlY alloys. Cryomilling of NiAl results in aluminum nitride (AlN) formation that reduces the coefficient of thermal expansion (CTE) of the alloy and enhances creep strength. Thus, additions of cryomilled NiAl-AlN to CoCrAlY were examined as a potential bond coat. In this work, the composite alloy was investigated as a stand-alone substrate to demonstrate its feasibility prior to actual use as a coating. About 85 percent of prealloyed NiAl and 15 percent of standard commercial CoCrAlY alloys were mixed and cryomilled in an attritor with stainless steel balls used as grinding media. The milling was carried out in the presence of liquid nitrogen. The milled powder was consolidated by hot extrusion or by hot isostatic pressing. From the consolidated material, oxidation coupons, four-point bend, CTE, and tensile specimens were machined. The CTE measurements were made between room temperature and 1000 C in an argon atmosphere. It is shown that the CTE of the NiAl-AlN-CoCrAlY composite bond coat is lower than that of the commercially used coating alloy 16-6. To examine the potential of NiAl-AlN-CoCrAlY as a bond coat, we subjected two samples to cyclic furnace testing. The furnace cycle consisted of 45 min at 1163 C (2125 F ) followed by 15 min of cooling out of the furnace. The current NASA baseline TBC is a NiCrAlY bond coat below the 7YSZ top coat. The average TBC life for this baseline coating on Ren N5 is 188 plus or minus 19 cycles. NiAl-AlN-CoCrAlY specimens coated with the same 7YSZ top coat were still intact even after 1000 cycles. Therefore, the NiAl-AlN-CoCrAlY as a bulk substrate material, exhibits more than 5 times the life of the current state-of-the-art material. The next step is to evaluate this material as a coating on the same superalloy substrate.

Source record↗

NASA Glenn/AADC-Rolls Royce Collaborated to Measure Erosion Resistance on Coated Polymer Matrix Composites

Polymer matrix composites (PMCs) are increasingly used in aerospace and automotive applications because of their light weight and high strength-to-weight ratio relative to metals. However, a major drawback of PMCs is poor abrasion resistance, which restricts their use, especially at high temperatures. Simply applying a hard coating on PMCs to improve abrasion and erosion resistance is not effective since coating durability is short lived (ref. 1). Generally, PMCs have higher coefficients of thermal expansion than metallic or ceramic coatings have, and coating adhesion suffers because of poor interfacial adhesion strength. One technique commonly used to improve coating adhesion or durability is the use of bond coats that are interleaved between a coating and a substrate with vastly different coefficients of thermal expansion. An example of this remedy is the use of bondcoats for ceramic thermal barrier coatings on metallic turbine components (ref. 2). Prior collaborative research between the NASA Glenn Research Center and the Allison Advanced Development Company (AADC) demonstrated that bond coats sandwiched between PMCs and high-quality plasma-sprayed, erosion-resistant coatings substantially improved the erosion resistance of PMCs (ref. 3). One unresolved problem in this earlier collaboration was that there was no easy, accurate way to measure the coating erosion wear scar. Coating wear was determined by both profilometry and optical microscopy. Both techniques are time consuming. Wear measurement by optical microscopy requires sample destruction and does not provide a comprehensive measure of the entire wear volume. An even more subtle, yet critical, problem is that these erosion coatings contain two or more materials with different densities. Therefore, simply measuring specimen mass loss before and after erosion will not provide an accurate gauge for coating and/or substrate volume loss. By using a noncontact technique called scanning optical interferometry, which was recently developed at Glenn, researchers can accurately determine the wear performance of erosion-coated PMCs while preserving the sample. An example of this interferometry technique is shown in the preceding figure for an erosion-coated inlet guide vane from a Rolls Royce AE3007 regional gas turbine jet engine. Erosion was conducted with coated and uncoated PMC vanes, with the abrasive material moving at a velocity of 229 m/s at impingement angles of 20 and 90 degrees. The coatings for PMCs remarkably reduced the erosion volume loss by a factor of approximately 10. Currently, several erosion coatings for PMCs are being compared and downselected for engine testing at Rolls Royce.

Miyoshi, Kazuhisa↗

Evaluation of oxide-coated iridium-rhenium chambers

Iridium-coated rhenium (Ir-Re) provides long life operation of radiation-cooled rockets at temperatures up to 2200 C. Ceramic oxide coatings could be used to increase Ir-Re rocket lifetimes and allow operation in highly oxidizing environments. Ceramic oxide coatings promise to serve as both thermal and diffusion barriers for the iridium layer. Seven ceramic oxide-coated Ir-Re, 22-N rocket chambers were tested with gaseous hydrogen/gaseous oxygen (GHz/G02) propellants. Five chambers had thick (over 10 mils), monolithic coatings of either hafnia (HfO2) or zirconia (ZrO2). Two chambers had coatings with thicknesses less than 5 mils. One of these chambers had a thin-walled coating of ZrO2 infiltrated with sol gel HfO2. The other chamber had a coating composed of an Ir-oxide composite. The purpose of this test program was to assess the ability of the oxide coatings to withstand the thermal shock of combustion initiation, adhere under repeated thermal cycling, and operate in aggressively oxidizing environments. All of the coatings survived the thermal shock of combustion and demonstrated operation at mixture ratios up to 11. Testing the Ir-oxide composite-coated chamber included over 29 min at mixture ratio 16. The thicker walled coatings provided the larger temperature drops across the oxide layer (up to 570 C), but were susceptible to macrocracking and eventual chipping at a stress concentrator. The cracks apparently resealed during firing, under compression of the oxide layer. The thinner walled coatings did not experience the macrocracking and chipping of the chambers that was seen with the thick, monolithic coatings. However, burn-throughs in the throat region did occur in both of the thin-walled chambers at mixture ratios well above stoichiometric. The burn-throughs were probably the result of oxygen diffusion through the oxide coating that allowed the underlying Ir and Re layers to be oxidized. The results of this test program indicated that the thin-walled oxide coatings are better suited for repeated thermal cycling than the thick-walled coating, while thicker coatings may be required for operation in aggressively oxidizing environments.

Reed, Brian D.↗

Testing and evaluation of oxide-coated iridium/rhenium chambers

Iridium-coated rhenium provides long life operation of radiation-cooled rockets at temperatures up to 2200 C. Ceramic oxide coatings could be used to increase iridium/rhenium rocket lifetimes and allow operation in highly oxidizing environments. Ceramic oxide coatings promise to serve as both thermal and diffusion barriers for the iridium layer. Seven ceramic oxide-coated iridium/rhenium, 22 N rocket chambers were tested on gaseous hydrogen/gaseous oxygen propellants. Five chambers had thick (over 10 mils), monolithic coatings of either hafnia or zirconia. Two chambers had coatings with thicknesses less than 5 mils. One of these chambers had a thin-walled coating of zirconia infiltrated with sol gel hafnia. The other chamber had a coating composed of an iridium/oxide composite. The purpose of this test program was to assess the ability of the oxide coatings to withstand the thermal shock of combustion initiation, adhere under repeated thermal cycling, and operate in aggressively oxidizing environments. All of the coatings survived the thermal shock of combustion and demonstrated operation at mixture ratios up to 11. The iridium/oxide composite coated chamber included testing for over 29 minutes at mixture ratio 16. The thicker-walled coatings provided the larger temperature drops across the oxide layer (up to 570 C), but were susceptible to macrocracking and eventual chipping at a stress concentrator. The cracks apparently resealed during firing, under compression of the oxide layer. The thinner-walled coatings did not experience the macrocracking and chipping of the chambers seen with the thick, monolithic coatings. However, burnthroughs in the throat region did occur in both of the thin-walled chambers at mixture ratios well above stochiometric. The burn-throughs were probably the result of oxygen-diffusion through the oxide coating that allowed the underlying iridium and rhenium layers to be oxidized. The results of this test program indicated that the thin-walled oxide coatings are better suited for repeated thermal cycling than the thick-walled coating, while thicker coatings may be required for operation in aggressively oxidizing environments.

Reed, Brian D.↗

Gear Performance Improved by Coating

Gears, bearings, and other mechanical elements transmit loads through contacting surfaces. Even if properly designed, manufactured, installed, and maintained, gears and bearings will eventually fail because of the fatigue of the working surfaces. Economical means for extending the fatigue lives of gears and bearings are highly desired, and coatings offer the opportunity to engineer surfaces to extend the fatigue lives of mechanical components. A tungsten-containing diamondlike-carbon coating exhibiting high hardness, low friction, and good toughness was evaluated for application to spur gears. Fatigue testing was done at the NASA Glenn Research Center on both uncoated and coated spur gears. The results showed that the coating extended the surface fatigue lives of the gears by a factor of about 5 relative to the uncoated gears. For the experiments, a lot of spur test gears made from AISI 9310 gear steel were case-carburized and ground to aerospace specifications. The geometries of the 28-tooth, 8-pitch gears were verified as meeting American Gear Manufacturing Association (AGMA) quality class 12. One-half of the gears were randomly selected for coating. The method of coating was selected to achieve desired adherence, toughness, hardness, and low-friction characteristics. First the gears to be coated were prepared by blasting (vapor honing) with Al2O3 particles and cleaning. Then, the gears were provided with a thin adhesion layer of elemental chromium followed by magnetron sputtering of the outer coating consisting of carbon (70 at.%), hydrogen (15 at.%), tungsten (12 at.%), and nickel (3 at.%) (atomic percent at the surface). In total, the coating thickness was about 2.5 to 3 microns. As compared with the steel substrate, the coated surface was harder by a factor of about 2 and had a smaller elastic modulus. All gears were tested using a 5-centistoke synthetic oil, a 10,000-rpm rotation speed, and a hertzian contact stress of at least 1.7 GPa (250 ksi). Tests were run until either surface fatigue occurred or 300 million stress cycles were completed. Tests were run using either a pair of uncoated gears or a pair of coated gears (coated gears mated with uncoated gears were not evaluated). The fatigue test results, shown on Weibull coordinates in the graph, demonstrate that the coating provided substantially longer fatigue lives even though some of the coated gears endured larger stresses. The increase in fatigue life was a factor of about 5 and the statistical confidence for the improvement is high (greater than 99 percent). Examination of the tested gears revealed substantial reductions of total wear for coated gears in comparison to uncoated gears. The coated gear surface topography changed with running, with localized areas of the tooth surface becoming smoother with running. Theories explaining how coatings can extend gear fatigue lives are research topics for coating, tribology, and fatigue specialists. This work was done as a partnership between NASA, the U.S. Army Research Laboratory, United Technologies Research Corporation, and Sikorsky Aircraft.

Krantz, Timothy L.↗

Microstructural Observations on Advanced Multilayer Protective Coatings for Nuclear Thermal Propulsion

The present research discusses the microstructures of a new multilayered coating concept proposed to solve the “midrange corrosion” problem observed in NbC and ZrC-coated graphite (Gr) nuclear fuels during the NERVA/Rover programs. The concept envisions designing a compliant multilayered coatings architecture to accommodate the thermal expansion mismatch strains between the ZrC outer coating and the Gr/(U,Zr)C fuel matrix along with using a diffusion barrier to minimize carbon and hydrogen diffusion, respectively. Multilayered coatings were deposited on Gr substrates by chemical vapor deposition (CVD). Graphite disks, as well as the inner channels of a 19-hole hexagonal rod 152.4 mm long, were coated by CVD in proof-of concept process demonstration studies. Coated disk specimens were thermally-cycled between ambient and 1900 K for as long as 20 cycles with a 1h hold time at the temperature using both stepped and non-interrupted thermal cycling methods. Detailed cross-sectional microstructural analyses were conducted on the thermally-cycled coated disks. These results showed that the coatings were intact after 20 thermal cycles at 1900 K although the bonding of the overlay Mo coating appeared to be influenced by the oxygen content in the layer. Seven transverse sections were cut along the length from the coated hexagonal rod for microstructural studies. All the nineteen channels were observed to have been coated in all the sections. This paper reports the results of detailed microstructural analyses, compositional line scans and x-ray dot maps conducted on three coated channels from a mid-section of the rod. The measured values of carbon (C) were observed to be exceptionally high in all the specimens, which were attributed to hydrocarbon contamination of the specimen surfaces. It was observed that the oxygen (O) levels were high in all the coating layers even after approximately correcting for the observed high values of C. The source of O contamination of the CVD reactor system was attributed to either the presence of oxychloride impurities in the precursor salts or a pin hole leak in the coating system. It is concluded that high values of O result in poor bonding of the Mo overlay to the ZrC layer. These trials have established that it is possible to deposit multilayered coatings by CVD in 19-hole hexagonal rods 152.4 mm long similar to the NERVA fuel rod design although the quality of the coatings and the uniformity of their thicknesses require further improvement.

Nuclear thermal propulsion, multilayer coatings, m↗

Chromium Tolerant, Highly Active and Stable Electrocatalytic Internal Surface Coating for Cathode of Commercial SOFCs (Final Report)

This project is aimed to develop a chromium (Cr) tolerant, highly active, and stable coating layer on the internal surfaces of the porous composite cathode from commercially available SOFCs. Such coating layer was developed using the additive manufacturing process of Atomic Layer Deposition (ALD) and has been applied on the cathode consisting of either an electronic conductor of LaxSr 1-x MnyO 3-δ (LSM) or mixed ionic and electronic conducting La x Sr 1-x Co y Fe 1-y O 3-δ (LSCF). PI's work has demonstrated that the internal surface of cathode from the commercial cells, can be further tailored using ALD coating to dramatically enhance the cell performance. For instance, ALD layer consisting heterostructured nano composite of nano-Pt and nano-(Mn 0.8 Co 0.2 ) 3 O 4 oxide on the internal surface of porous LSM/YSZ cathode from SOFCs, has resulted in the large reduction of the cell polarizations resistance by up to 53%, and enormous increase of power density over 370%. For the cells with LSCF/Sm 2 O 3 doped CeO 2 (SDC) cathode, the conformal layer of nano-composite consisting of superjacent CoOx and subjacent minimum amount of Pt nano-grains has resulted in the power density enhancement by 126% for the large scale industry tubular cells at 750°C, and both the performance enhancement and nanostructure of the ALD layer are stable over ~ 2000 h continuous operation performed at industry test station. In the meanwhile, those ALD coating layer developed by PI's work is also inherently Cr-tolerant, and could act as physical barrier for preventing Cr diffusion into the cathode backbone, so as to mitigate the Cr poisoning effect on the cathode. In this project, the impact of Cr on the performance of those ALD coated commercial cells has been evaluated. Based on evolution of the cell performance, the ALD coating layer chemistry and ALD coating layer thickness has been optimized to maximize the overall Cr tolerance, cell power density and cell longevity. Different ALD coating has been applied onto the internal surface of LSM/YSZ and LSCF/SDC backbone respectively. The architecture/scaffold structures on the internal surface of different cathode, designed by this project, was catalogued and analyzed using High Resolution Transmission Electron Microscopy (HRTEM), and cell power/durability performance are assured via comprehensive electrochemical performance testing in the industry operation relevant conditions. The impact of the electrochemical operation current density, the water humidity, the cell operation temperature, and cell operation duration on the Cr tolerance of ALD coated cells has been systematically investigated. There is completely different nanostructure degradation mechanisms between LSM and LSCF cells induced by Cr contamination. For the LSCF/SDC baseline cell, With the Cr source, there is no apparent Sr surface segregation phase even for the baseline cell operated for 3000 h at 750 °C. With the Cr source, there is significant amorphous (SrCr)Ox phase accumulated in the original pore region. For the commercial baseline cells, Cr contaminants on the LSM electrode severely impacted the entire cell's electrochemical performance and nanostructure degradation. Those degradations include (1). Peak power density loss of 64 % after 109 h of operation. The dramatic increase in Rp (2). They are cracking at LSM/SSZ interface, LSM grains. SSZ remains intact but with (CrMn)Ox. By contrast, ALD coating (MnCo)Ox/Pt dramatically improves the Cr resistance, as follows (1). ALD-coated cell with a power density is 280-380 % of the baseline cell, depending on the ALD layer thickness. (2). For a cell with a 20 nm thick ALD layer, there is a large performance enhancement (> 200 % power density) induced by ALD coating of Cr-tolerant Mn 0.8 Co 0.2 Ox. (3). For a cell with a 20 nm thick ALD layer, after 168 h at 750 °C power density of the ALD-coated cell is ~ 600% of that baseline cell upon operation with Cr contamination for 109 h. The ALD coating on the internal surface of cathode developed by this project integrated multi-functions. Those multi-functions include (1). Dramatically improving the cell power density for the commercial cells; (2). Dramatically improving contamination resistance of the cathode, for being an excellent protection coating layer sealing off Cr contamination. (3). Dramatically increasing the cell longevity by potentially preventing the microstructure evolution and grain coarsening of the cathode. Overall, this project will provide a simple solution to simultaneously enhance power density and increase the reliability, robustness, and endurance of commercial SOFCs, over the entire operating temperature range of 650-800 °C. For the inherently functional SOFC, the ALD coating of LSM based cathode mitigate the Cr-contamination. Power density of ALD-coated cell is ~ 600% of that baseline cell upon operation with Cr contamination. In addition to SOFCs, the novel on-demand design approach and creation of multifunctional heterogeneous architecture on the electrode surface presented in this work opens further research for their application in other types of fuel cells, batteries, and sensors for which electrochemical reactions on the surface are similarly critical.

36 MATERIALS SCIENCE↗

Effect of Air Plasma Sprayed Flash Bond Coatings on Furnace Cycle Lifetime of Disks and Rods

Air plasma sprayed (APS) flash coatings on high velocity oxygen fuel (HVOF) bond coatings are well known to extend the lifetime of thermal barrier coatings (TBCs). Recent work compared flash coatings of NiCoCrAlY and NiCoCrAlYHfSi applied to both rods and disk substrates of alloy 247. For rod specimens, 100 h cycles were used at 1100 °C in wet air. Both flash coatings significantly improved the lifetime compared to HVOF-only and vacuum plasma spray (VPS)-only MCrAlY bond coatings with no statistical difference between the two flash coatings. For disk specimens tested in 1 h cycles at 1100 °C in wet air, the NiCoCrAlY flash coating significantly outperformed an HVOF-only NiCoCrAlYHfSi bond coating and a NiCoCrAlYHfSi flash coating. The flash coatings formed a mixed oxide-metal zone that appeared to inhibit crack formation and therefore extend lifetime. In addition to the flash coating increasing the bond coating roughness, the underlying HVOF layer acted as a source of Al for this intermixed zone and prevented the oxide from penetrating deeper into the bond coating. Here, the lower Y+Hf content in the Y-only flash coating appeared to minimize oxidation in the flash layer, thereby increasing the benefit compared to a NiCoCrAlYHfSi flash coating.

42 ENGINEERING↗

High Throughput In-Line Coating Metrology Development for Solid Oxide Fuel Cell Manufacturing

Coatings play key roles in solid oxide fuel cell (SOFC) stack durability. For example, diffusion barrier coatings on Cr-containing interconnect and balance of plant (BOP) components protect electrodes from Cr poisoning over the long operational lifetimes (>10,000 hours) of the fuel cell stack. Common defects in coatings, such as cracks, pinholes, and porosity, result in a failure to protect the electrodes, resulting in shorter operational lifetime and thus higher cost. It is very unlikely, even in the best coating process, that all these defects can be mitigated, hence identifying critical defects in parts, and removing defective parts from production before they can damage the stack, becomes paramount. Furthermore, these quality control techniques must be operational in the production/assembly line (in-line), i.e., high throughput and non-destructive, and cost effective. Redox Power Systems, LLC (Redox) together with the National Renewable Energy Laboratory (NREL) developed much needed high throughput, in-line metrology techniques for protective coatings. The overall goal of the project is to lower cost while increasing robustness, reliability, and endurance of SOFC stacks. To accomplish this, we had several objectives, including: to identify key coating and substrate defects that lead to coating failure through the use of detailed characterization methods (e.g., microscopy, XRD, EDS, electrochemistry); to assess capabilities of in-line metrology techniques, e.g., optical profilometry (Redox) and thermography (NREL), to probe these defects, or evidence thereof; demonstrate long-term performance of “defect-free” protective coatings, as identified by in-line metrology, in solid oxide fuel cell (SOFC) stack operation. In the first part of this project, the ability to identify key defects expected to lead to coating and SOFC degradation using in-line metrology tools were evaluated. Coated interconnect samples with controlled defect types and populations were tested under conditions similar to SOFC operation, followed by detailed post-test analysis to reveal the defects responsible for observed degradation. In the second part of the project, the optimal in-line metrology techniques and methodologies were used to map the defect distribution in full-size interconnects with critical defects intentionally allowed to exist in some cases. These interconnects underwent SOFC testing for extended periods (up to ~3,000 hours) followed by post-test analysis to evaluate the effectiveness of in-line metrology techniques in mitigating MCO coating related degradation. Key accomplishments in this project included the following: Demonstrated ASR of < 0.05 ohm-cm 2 at 650 °C for 1,000 hours with low defect (determined by in-line metrology) interconnect samples (average ASR=37 milliohms-cm 2 after over 1,000 hours). Demonstrated that low defect coatings on interconnects (as screened using in-line metrology) have low volatilization of chromium at ~650 °C for 1,000 hours as detected using Cr-getter material (< 5 at% increase above baseline); 1022 hour duration tests under humidified, elevated temperature (750 °C rather than 650 °C) compared a base case against different coating thicknesses. Demonstrated capability to identify initial key defects of interest with in-line metrology techniques using up to 8 cm by 10 cm having coatings with and without intentional defects of interest using thermal imaging and optical profilometry. Correlated key defects identified using metrology techniques with observed coating performance (e.g., ASR and Cr volatility). Conducted several 4 cm by 4 cm cell tests using MCO-interconnects that were pre-screened using some of the metrology techniques developed in the project (e.g., optical profilometry). An analysis of ASR measurements were able to show that defect-free coatings resulted in the anticipated performance in the cell tests.

01 COAL, LIGNITE, AND PEAT↗

Impact of Irradiation on Corrosion Performance of Hybrid Organic/Inorganic Coatings on Austenitic Stainless Steel

The effects of gamma radiation on the performance of two corrosion-resistant coatings applied to stainless-steel 304L (SS304L) surfaces are presented. Specifically, the ability of the coatings to mitigate corrosion of SS304L surfaces as a function of the dose received (0–1300 Mrad) and dose rate (176 compared to 1054 rad/s) is evaluated using electrochemical methods, spectroscopy, and microscopy. Coating A, an organic/inorganic hybrid coating consisting of a two-part silica ceramic component and a polymer linker was evaluated in comparison to Coating B, which utilized Coating A as a topcoat for a commercial, off-the-shelf, Zn-rich primer. Post irradiation, Coating A demonstrated some corrosion protection following exposure to low levels of gamma radiation, but coating degradation occurred with an increased exposure dose and resulted in isolated regions of corrosion initiation. For Coating B, greater corrosion resistance was observed compared to Coating A due to the sacrificial nature of the Zn at elevated doses of gamma radiation. No effect of the dose rate (for the single dose examined) was observed for either coating. It is proposed for Coating B that as the polymer coating thermally degrades above 250 °C (bond scission of the polymer occurs), the remaining Zinc layer adhered to the SS304L post-irradiation enables enhanced corrosion resistance as compared to Coating A, which displays solely polymer degradation. The results presented herein establish an understanding of coating behavior with radiation exposure, specifically the relationship between corrosion coating performance and radiation dose, and can inform ageing and lifetime management for various applications.

degradation↗

Development and Performance Evaluations of HfO2-Si and Rare Earth-Si Based Environmental Barrier Bond Coat Systems for SiC/SiC Ceramic Matrix Composites

Ceramic environmental barrier coatings (EBC) and SiCSiC ceramic matrix composites (CMCs) will play a crucial role in future aircraft propulsion systems because of their ability to significantly increase engine operating temperatures, improve component durability, reduce engine weight and cooling requirements. Advanced EBC systems for SiCSiC CMC turbine and combustor hot section components are currently being developed to meet future turbine engine emission and performance goals. One of the significant material development challenges for the high temperature CMC components is to develop prime-reliant, high strength and high temperature capable environmental barrier coating bond coat systems, since the current silicon bond coat cannot meet the advanced EBC-CMC temperature and stability requirements. In this paper, advanced NASA HfO2-Si based EBC bond coat systems for SiCSiC CMC combustor and turbine airfoil applications are investigated. The coating design approach and stability requirements are specifically emphasized, with the development and implementation focusing on Plasma Sprayed (PS) and Electron Beam-Physic Vapor Deposited (EB-PVD) coating systems and the composition optimizations. High temperature properties of the HfO2-Si based bond coat systems, including the strength, fracture toughness, creep resistance, and oxidation resistance were evaluated in the temperature range of 1200 to 1500 C. Thermal gradient heat flux low cycle fatigue and furnace cyclic oxidation durability tests were also performed at temperatures up to 1500 C. The coating strength improvements, degradation and failure modes of the environmental barrier coating bond coat systems on SiCSiC CMCs tested in simulated stress-environment interactions are briefly discussed and supported by modeling. The performance enhancements of the HfO2-Si bond coat systems with rare earth element dopants and rare earth-silicon based bond coats are also highlighted. The advanced bond coat systems, when integrated with advanced EBC top coats, showed promise to achieve 1500 C temperature capability, helping enable next generation turbine engines with significantly improved engine component temperature capability and long-term durability.

HfO2-Si bond coat↗

Advanced thermal barrier coating systems

Current state-of-the-art thermal barrier coating (TBC) systems consist of partially stabilized zirconia coatings plasma sprayed over a MCrAlY bond coat. Although these systems have excellent thermal shock properties, they have shown themselves to be deficient for a number of diesel and aircraft applications. Two ternary ceramic plasma coatings are discussed with respect to their possible use in TBC systems. Zirconia-ceria-yttria (ZCY) coatings were developed with low thermal conductivities, good thermal shock resistance and improved resistance to vanadium containing environments, when compared to the baseline yttria stabilized zirconia (YSZ) coatings. In addition, dense zirconia-titania-yttria (ZTY) coatings were developed with particle erosion resistance exceeding conventional stabilized zirconia coatings. Both coatings were evaluated in conjunction with a NiCr-Al-Co-Y2O3 bond coat. Also, multilayer or hybrid coatings consisting of the bond coat with subsequent coatings of zirconia-ceria-yttria and zirconia-titania-yttria were evaluated. These coatings combine the enhanced performance characteristics of ZCY with the improved erosion resistance of ZTY coatings. Improvement in the erosion resistance of the TBC system should result in a more consistent delta T gradient during service. Economically, this may also translate into increased component life simply because the coating lasts longer.

Dorfman, M. R.↗

Unraveling the Formation Mechanism of a Hybrid Zr-Based Chemical Conversion Coating with Organic and Copper Compounds for Corrosion Inhibition

Environmental-friendly chromate-free, zirconium (Zr)-based conversion coating is a promising green technology for corrosion protection. Additives in the surface treatment provides critical functionalities and performance improvements; however, mechanistic understanding as of how the additives influence the coatings remains unclear. In this study, a new organic-inorganic hybrid Zrbased conversion coating which combines copper (Cu) compounds and polyamidoamine (PAMAM), taking advantages of a complementary nature of organic and inorganic additives. Here, a multimodal approach combining electron and X-ray characterization is applied to study the interaction of Cu 2+ and PAMAM and the resulting impacts on the coating formation. Adding PAMAM changed the surface morphology, thickness, distribution of Cu in the cluster and void formation of the coatings. High PAMAM (100-200 pm) leads to little conversion coating formation, and low PAMAM (0-25 ppm) shows voids formation under the coatings. Moreover, PAMAM incorporates in the coating in a form of PAMAM-Cu complex with a higher concentration towards the surface, provides an organic layer at the surface of the coating. X-ray absorption near-edge structure (XANES) spectroscopy shows a difference between the conventional and hybrid coating treatments in an alkaline solution to simulate the E-coat process, suggesting the contribution of PAMAM in the enhanced chemical stability in an alkaline environment. Therefore, an intermediate range of addition of PAMAM (50 ppm) is optimal to 1) avoid excessive voids formation, 2) promote some Cu cluster formation and thus enhancing the Zr-based coating formation and 3) incorporate organic components into the coating to improve the adhesion of the subsequent coatings. Overall, this work furthers our knowledge on the formation mechanism of an effective and environmentally friendly hybrid conversion coating for corrosion inhibition, demonstrating a critical processing-structureproperty relationship. This study will benefit future development of green and effective surface treatment technology.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Polymer coatings on zirconia microspheres via rotating flow fluid dynamics

Conventional tristructural isotropic (TRISO) coatings for nuclear fuels require multi-step and expensive formation processes; any breakage of the coatings may lead to fission species release. Polymer derived ceramic (PDC) coatings can be a suitable alternative to address these issues. In this study, allylhydridopolycarbosilane (SMP-10) coatings were created on yttria stabilized zirconia (YSZ) microspheres using a Rotating Flow Fluid Dynamics (RFFD) coating method. The effects of curing temperature, rotation speed, and coating cycle/time on the coating were analyzed. Surface functionalization of YSZ microspheres with NaOH resulted in good adhesion between the polymer precursor and the YSZ kernel particles. Spectroscopy analysis revealed complete curing of SMP-10 coated YSZ at 160 °C. Rotation speed and coating time significantly affect the coating characteristics. After 3 cycles at lower rotation speed (50 rpm) for 10 min each, the coating obtained was uniform and homogeneous. In comparison, the coating showed almost 10 times less eccentricity at a high rotation speed of 300 rpm. Compared with the coatings prepared at 300 rpm condition, the coatings have higher sphericity and lower eccentricity at 50 rpm. Overall, this study provides a novel and effective route for fabricating and curing SMP-10 precursor coatings on YSZ microspheres.

Ravi, Nivetha [University of Alabama, Birmingham]↗

Thermal Processing Effects on the Adhesive Strength of PS304 High Temperature Solid Lubricant Coatings

In this paper the effects of post deposition heat treatments on the cohesive and adhesive strength properties of PS304, a plasma sprayed nickel-chrome based, high temperature solid lubricant coating deposited on stainless steel, are studied. Plasma spray deposited coating samples were exposed in air at temperatures from 432 to 650 C for up to 500 hr to promote residual stress relief, enhance particle to particle bonding and increase coating to substrate bond strength. Coating pull-off strength was measured using a commercial adhesion tester that utilizes 13 mm diameter aluminum pull studs attached to the coating surface with epoxy. Pull off force was automatically recorded and converted to coating pull off strength. As deposited coating samples were also tested as a baseline. The as-deposited (untreated) samples either delaminated at the coating-substrate interface or failed internally (cohesive failure) at about 17 MPa. Samples heat treated at temperatures above 540 C for 100 hr or at 600 C or above for more than 24 hr exhibited strengths above 31 MPa, nearly a two fold increase. Coating failure occurred inside the body of the coating (cohesive failure) for nearly all of the heat-treated samples and only occasionally at the coating substrate interface (adhesive failure). Metallographic analyses of heat-treated coatings indicate that the Nickel-Chromium binder in the PS304 appears to have segregated into two phases, a high nickel matrix phase and a high chromium precipitated phase. Analysis of the precipitates indicates the presence of silicon, a constituent of a flow enhancing additive in the commercial NiCr powder. The exact nature and structure of the precipitate phase is not known. This microstructural change is believed to be partially responsible for the coating strength increase. Diffusion bonding between particles may also be playing a role. Increasing the heat treatment temperature, exposure time or both accelerate the heat treatment process. Preliminary measurements indicate that the heat treatment also results in a one time, permanent coating thickness increase of about 3%. Based upon these results, the incorporation of a heat treatment prior to final finishing has been incorporated in the application process of this coating technology.

DellaCorte, Christopher↗

Stresses within rare-earth doped yttria-stabilized zirconia thermal barrier coatings from in-situ synchrotron X-ray diffraction at high temperatures

There is a growing interest for smart coatings that can be integrated into turbine engines for in-situ temperature measurements or health monitoring. The addition of rare-earth dopants into standard thermal barrier ceramic top coat materials is used to obtain luminescent coatings that enable spectral measurements, for real-time temperature or health monitoring. The thermomechanical performance and durability of such novel coating compositions in extreme environments still remains to be evaluated. Consequently, the ability to manufacture sensor coatings which present suitable thermal properties needs to be demonstrated. For this study, highly luminescent erbium and europium doped yttria-stabilized zirconia and state-of-the-art yttria-stabilized zirconia coatings manufactured by air plasma spray were characterized to determine the effects of the embedded rareearth dopants on coating internal strain and stress and to quantify and compare their high temperature response using synchrotron X-ray diffraction. In-situ depth-resolved strain measurements were performed at 15 μm intervals along the depth of the coatings to evaluate materials response at key locations, specifically at layer interfaces. In-plane stress was calculated for the coatings and a finite element model was implemented to supplement the results and enable further predictions. The results show that the sensor coatings that were manufactured in this work revealed only minor variations in the strain response of sensor coatings under a typical thermal cycle and especially at temperatures closer to that of gas turbine operating conditions, compared to state-of-the-art coatings. This work demonstrates the viability of manufacturing rare-earth doped yttria-stabilized zirconia coatings that provide beneficial spectroscopic monitoring capabilities while having minimal impact on the thermomechanical response of the thermal barrier coatings.

Air plasma spray↗

Characterization of the Benefit of APS Flash Coatings in Improving TBC Lifetime

The addition of an air plasma sprayed (APS) “flash” layer on top of a high velocity oxygen fuel (HVOF) bond coating has been shown to extend the lifetime of thermal barrier coatings. A series of furnace cycle tests (FCTs) has been conducted at 1100 °C in air + 10% H 2 O to study the benefit of flash coatings on rod and disk alloy 247 specimens and provide a better mechanistic understanding of their benefit. Flash coatings of NiCoCrAlY and NiCoCrAlYHfSi both improved the FCT lifetime of rod specimens tested in 100-h cycles and disk specimens tested in 1-h cycles. In 1-h cycles, the NiCoCrAlY flash coating significantly outperformed an HVOF-only NiCoCrAlYHfSi bond coating and a NiCoCrAlYHfSi flash coating. Both flash coatings increased the bond coating roughness compared to HVOF. During exposure, the flash layer formed an intermixed alumina-metal layer that appeared to inhibit crack formation. Using a time series of observations, the lower Y + Hf content in the Y-only flash coating appeared to reduce Al consumption. The HVOF layer acted as a source of Al for the adjacent mixed zone. A second series of specimens included a fully APS bond coating where oxide had penetrated through the entire coating to the substrate after only 100, 1-h cycles and lifetime was similar to an HVOF-only bond coating. The inner HVOF layer with the outer APS flash coating prevented this complete penetration from occurring.

Pint, Bruce↗

Conductive Tether Coating for Electrodynamic Tethers

The Propulsive Small Expendable Deployer System (ProSEDS), which is an on-orbit demonstration of the propulsion capabilities of electrodynamic tethers in space, is a secondary payload on a Delta 11 unmanned expendable booster. The ProSEDS tether consists of a 5 km bare electrodynamic tether and a 1 0-km non-conductive leader tether. Near the Delta 11, 160 m of the conductive tether is insulated to prevent plasma electron collection from the plasma contactor and for other science requirements. The remainder of the 5-km conductive tether is coated with a new conductive coating to collect plasma electrons. A bare metal tether easily collects electrons from the plasma, but thermal concerns preclude this design. A highly emissive conductive polymer developed by Triton Systems, Inc. has been optimized for both conductivity and thermo-optical properties. The current design for the ProSEDS conductive tether is seven individually coated strands of 28 AWG aluminum wire, coated with an atomic oxygen-resistant conductive polymer composed of a mixture of COR (Colorless Oxygen Resistant) and polyanaline (PANI) known as C-COR (Conductive-Colorless Oxygen Resistant). The conductive-coated wire strands are cold-welded to individually coated strands of the insulated tether. The insulated tether is coated with 1 mil of polyimide and an atomic oxygen resistant polymer TOR-BP. The insulated tether must stand off the entire voltage of the tether (1 200 V) at various times during the mission. All seven wires are twisted around a Kevlar-29 core using the Hi-wire design. Extensive testing has been performed at the Marshall Space Flight Center to qualify both the conductive coating and insulating coating for use on the ProSEDS tether. The conductive coating has been exposed to a plasma to verify the coatings ability to collect electrons from the space plasma from 0 to 1500 V, and to verify the coatings ability to collect electrons after atomic oxygen exposure. The insulated coating has been tested to verify its dielectric strength both in a vacuum and air. Thermal optical properties on both coatings have been measured before and after atomic oxygen testing. The results of these tests will be presented.

Jason A Vaughn↗