Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CANCELLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Demonstration of Cross-Resonance Gates with Resonator-Assisted ZZ Cancellation

We present the characterization of a CNOT gate realized by combining cross-resonance interaction with resonator-assisted ZZ cancellation in fixed-frequency transmons on a Rigetti–SQMS co-developed quantum processor. Extending earlier work on dynamical ZZ cancellation via off-resonant resonator drives [1], we demonstrate a direct CNOT gate implementation achieved through two microwave drives on the transmons that generate a CX rotation in the |10⟩−|11⟩ subspace while selectively darkening the |00⟩−|01⟩ transition. This tunable-coupler-free approach enables high-fidelity gates and enhances the scalability of superconducting quantum architectures. [1] Z. Huang et al., Phys. Rev. Applied 22, 034007 (2024)

Heidler, Paul [Fermilab]↗

Coarse-fine residual gravity cancellation system with magnetic levitation

Aircraft flight along parabolic trajectories have been proposed and executed in order to achieve low cost, near free fall conditions of moderate duration. This paper describes a six degree of freedom experiment isolation system designed to cancel out residual accelerations due to mechanical vibrations and errors in aircraft trajectory. The isolation system consists of a fine motion magnetic levitator whose stator is transported by a conventional coarse motion stage. The levitator uses wide gap voice coil actuators and has the dual purpose of isolating the experiment platform from aircraft vibrations and actively cancelling residual accelerations through feedback control. The course motion stage tracks the levitated platform in order to keep the levitator's coils centered within their matching magnetic gaps. Aspects of system design, an analysis of the proposed control strategy and simulation results are presented. Feasibility experiments are also discussed.

Salcudean, S. E.↗

Canceling Torque Caused By Boiloff Of Cryogen

Proposed technique for cancellation of small torques caused by venting of cryogens from tanks in spacecraft adaptable to use in making small corrections in orientations of terrestrial scientific instruments. Torque eliminated by directing exhaust gas through "T" vent. To cancel remaining small torque, that side of "T" from which exhaust produces smaller thrust heated just enough to equalize opposing thrusts. Concept useful in situations in which conventional electromagnetic actuators not suitable because of constraints related to temperature, radiation, or vibration and equipment required to be robust, simple, reliable, light in weight, and without moving parts.

Bhandari, Pradeep↗

Polarization cancellation in the two-component winds from Wolf-Rayet stars

In this paper we explore the possibility that there can be at least partial cancellation of the equatorial disk polarization as a result of scattering from the electrons that are present in the strong polar wind of WR stars. In order to achieve the cancellation necessary to explain the wavelength-dependent polarization, the polar wind must have a mass-loss rate that is near the maximum that is supported by radiation-driven wind theory. In addition, we find that it is possible to derive important new information regarding the relative column masses of the polar and equatorial winds.

Taylor, M.↗

Cancellation control law for lateral-directional dynamics of a supermaneuverable aircraft

Cancellation control laws are designed which reduce the high levels of lateral acceleration encountered during aggressive rolling maneuvers executed at high angle of attack. Two independent problem are examined. One is to reduce lateral acceleration at the mass center, while the other focuses on lateral acceleration at the pilot's station, located 7.0 m forward of the mass center. Both of these problems are challenging and somewhat different in their limitations. In each case the design is based on a linearization of the lateral-directional dynamics about a high angle of attack condition. The controllers incorporate dynamic inversion inner loops to provide control of stability-axis roll- and yaw-rates and then employ cancellation filters in both feed-forward and feed-back signal paths. The relative simplicity of the control laws should allow nonlinear generalizations to be devised. Although it is shown that lateral acceleration can be reduced substantially by such control laws, this is at the cost of slowed roll response, poor dutch-roll damping or a combination of the two.

Snell, Antony↗

Prostaglandin E2 Prevents Ovariectomy-Induced Cancellous Bone Loss in Rats

The object of this study was to determine whether prostaglandin E2, (PGE2) can prevent ovariectomy induced cancellous bone loss. Thirty-five 3-month-old female Sprague-Dawley rats were divided into two groups. The rats in the first group were ovariectomized (OVX) while the others received sham operation (sham-OVX). The OVX group was further divided into three treatment groups. The daily doses for the three groups were 0,1 and 6 mg PGE2/kg for 90 days. Bone histomorphometric analyses were performed on double-fluorescent-labeled undecalcified proximal tibial metaphysis (PTM). We confirmed that OVX induces massive cancellous bone loss (-80%) and a higher bone turnover (+143%). The new findings from the present study demonstrate that bone loss due to ovarian hormone deficiency can be prevented by a low-dose (1 mg) daily administration of PGE2. Furthermore, a higher-dose (6 mg) daily administration of PGE2 not only prevents bone loss but also adds extra bone to the proximal tibial metaphyses. PGE, at the 1-mg dose level significantly increased trabecular bone area, trabecular width, trabecular node density, density of node to node, ratio of node to free end, and thus significantly decreased trabecular separation from OVX controls. At this dose level, these same parameters did not differ significantly from sham-OVX controls. However, at the 6-mg dose level PGE2, there were significant increases in trabecular bone area, trabecular width, trabecular node density, density of node to node, and ratio of node to free end, while there was significant decrease in trabecular separation from both OVX and sham-operated controls. The changes in indices of trabecular bone microanatomical structure indicated that PGE2 prevented bone loss as well as the disconnection of existing trabeculae. In summary, PGE2, administration to OVX rats decreased bone turnover and increased bone formation parameters resulting in a positive bone balance that prevented bone loss (in both lower and higher doses) and added extra bone to metaphyses of OVX rats (in higher dose). These findings support the strategy of the use of bone stimulation agents in the prevention of estrogen depletion bone loss (postmenopausal osteoporosis).

Ke, Hua Zhu↗

Greater Bone Fomation Induction Occurred in Aged Than Young Cancellous Bone Sites

We have determined the differences in the effects of continual prostaglandin E2 (PGE2) treatment in aged (non-growing) and young (growing) cancellous bone sites in 7 month-old Sprague-Dawley rats. The sites involved are the aged Distal Tibial Metaphysis (DTM) with a closed epiphysis and the young Proximal Tibial Metaphysis (PTM) with a slow growing, open epiphysis. The study involved rats treated with 0, 1, 3 or 6 mg PGE2/kg/d for 60, 120 and 180 days. Static and dynamic histomorphometty of percent trabecular area, and tissue-referent bone formation rate (BFR/TV) were determined in both DTM and PTM. In pretreatment controls, the secondary spongiosa of the two metaphyses contain the same amount of cancellous bone (11% in DTM vs. 13% in PTM), but markedly less bone formation in DTM (0.6%/y in DTM vs. 41.5%/y in PTM). After 60 days of 6 mg PGE2/kg/d treatment, %Tb.Ar was increased 607% in DTM and 199% in PTM, BFR/TV was increased to nearly 14 fold in DTM and only 5 fold in PTM. These results indicated the aged metaphysis of the DTM was much more responsive to PGE2 treatment than young, growing metaphysis of the PTM. The results of 120 and 180 days treatment did not significantly differ from 60 days treatment in both sites, indicating that the effect of continuous daily PGE2 treatment were in equilibrium after 60 days. We concluded that aged metaphysis was much more responsive to PGE2 treatment than young growing metaphysis.

Ke, H. Z.↗

Effects of Long-Term Daily Administration of Prostaglandin-E2 on Maintaining Elevated Proximal Tibial Metaphyseal Cancellous Bone Mass in Male Rats

The effects of long-term prostaglandin E(sub 2) (PGE(sub 2)) on cancellous bone in proximal tibial metaphysis were studied in 7 month old male Sprague-Dawley rats given daily subcutaneous injections of 0, 1, 3, and 6 mg PGE(sub 2)/kg/day and sacrificed after 60, 120, and 180 days. Histomorphometric analyses were performed on double fluorescent-labeled undecalcified bone specimens. After 60 days of treatment, PGE(sub 2) produced diffusely labeled trabecular bone area, increased trabecular bone area, eroded and labeled trabecular perimeter, mineral apposition rate, and bone formation rate at all dose levels when compared with age-matched controls. In rats given PGE(sub 2) for longer time periods (120 and 180 days), trabecular bone area, diffusely labeled trabecular bone area, labeled perimeter, mineral apposition, and bone formation rates were sustained at the elevated levels achieved earlier at 60-day treatment. The eroded perimeter continued to increase until 120 days, then plateau. The observation that continuous systemic PGE(sub 2) administration to adult male rats elevated metaphyseal cancellous bone mass to 3.5-fold of the control level within 60 days and maintained it for another 120 days indicates that the powerful skeletal anabolic effects of PGE2 can be sustained with continuous administration .

Ke, Hua Zhu↗

Greater Bone Formation Induction Occurred in Aged than Young Cancellous Bone Sites

We have determined the differences in the effects of continual prostaglandin E(sub 2) (PGE(sub 2) treatment in aged (non-growing) and young (growing) cancellous bone sites in 7-month-old Sprague-Dawley rats. The sites involved are the aged distal tibial metaphysis (DTM) with a closed epiphysis and the young proximal tibial metaphysis (PTM) with a slow growing, open epiphysis. The study involved rats treated with 0, 1, 3 or 6 mg PGE(sub 2)/kg/d for 60, 120 and 180 days. Static and dynamic histomorphometry of percent trabecular area, and tissue-referent bone formation rate (BFR/TV) were determined in both DTM and PTM. In pretreatment controls, the secondary spongiosa of the two metaphyses contain the same amount of cancellous bone (11% in DTM vs. 13% in PTM), but markedly less bone formation in DTM (0.6%/y in DTM vs. 41.5%/y in PTM). After 60 days of 6 mg PGE(sub 2)/kg/d treatment, %Tb.Ar was increased 607% in DTM and 199% in PTM, BFR/TV was increased to nearly 14 fold in DTM and only 5 fold in PTM. These results indicated the aged metaphysis of the DTM was much more responsive to PGE(sub 2) treatment than young, growing metaphysis of the PTM. The results of 120 and 180 days treatment did not significantly differ from 60 days treatment in both sites, indicating that the effect of continuous daily PGE2 treatment were in equilibrium after 60 days. We concluded that aged metaphysis was much more responsive to PGE(sub 2) treatment than young growing metaphysis.

Ke, H. Z.↗

Cancellation of Laser Noise in Space-Based Interferometer Detectors of Gravitational Radiation

We presented a time-domain procedure for accurately cancelling laser noise fluctuations in an unequal-arm Michelson interferometer. The method involves separately measuring the phase of the returning light relative to the phase of the transmitted light in each arm. By suitable offsetting and differencing of these two time series, the common laser noise is cancelled exactly. The technique presented in this paper is general, in such that it can be implemented with any (Earth as well as space-based) unequal-arms Michelson interferometers,

Tinto, Massimo↗

Ambient-Light-Canceling Camera Using Subtraction of Frames

The ambient-light-canceling camera (ALCC) is a proposed near-infrared electronic camera that would utilize a combination of (1) synchronized illumination during alternate frame periods and (2) subtraction of readouts from consecutive frames to obtain images without a background component of ambient light. The ALCC is intended especially for use in tracking the motion of an eye by the pupil center corneal reflection (PCCR) method. Eye tracking by the PCCR method has shown potential for application in human-computer interaction for people with and without disabilities, and for noninvasive monitoring, detection, and even diagnosis of physiological and neurological deficiencies. In the PCCR method, an eye is illuminated by near-infrared light from a lightemitting diode (LED). Some of the infrared light is reflected from the surface of the cornea. Some of the infrared light enters the eye through the pupil and is reflected from back of the eye out through the pupil a phenomenon commonly observed as the red-eye effect in flash photography. An electronic camera is oriented to image the user's eye. The output of the camera is digitized and processed by algorithms that locate the two reflections. Then from the locations of the centers of the two reflections, the direction of gaze is computed. As described thus far, the PCCR method is susceptible to errors caused by reflections of ambient light. Although a near-infrared band-pass optical filter can be used to discriminate against ambient light, some sources of ambient light have enough in-band power to compete with the LED signal. The mode of operation of the ALCC would complement or supplant spectral filtering by providing more nearly complete cancellation of the effect of ambient light. In the operation of the ALCC, a near-infrared LED would be pulsed on during one camera frame period and off during the next frame period. Thus, the scene would be illuminated by both the LED (signal) light and the ambient (background) light during one frame period, and would be illuminated with only ambient (background) light during the next frame period. The camera output would be digitized and sent to a computer, wherein the pixel values of the background-only frame would be subtracted from the pixel values of the signal-plus-background frame to obtain signal-only pixel values (see figure). To prevent artifacts of motion from entering the images, it would be necessary to acquire image data at a rate greater than the standard video rate of 30 frames per second. For this purpose, the ALCC would exploit a novel control technique developed at NASA s Jet Propulsion Laboratory for advanced charge-coupled-device (CCD) cameras. This technique provides for readout from a subwindow [region of interest (ROI)] within the image frame. Because the desired reflections from the eye would typically occupy a small fraction of the area within the image frame, the ROI capability would make it possible to acquire and subtract pixel values at rates of several hundred frames per second considerably greater than the standard video rate and sufficient to both (1) suppress motion artifacts and (2) track the motion of the eye between consecutive subtractive frame pairs.

Morookian, John Michael↗

Transient Fine-Scale Brightenings, Flows and Flux Cancellation in the Cool Arch Filament System Observed with HiC2.1

Solar active regions (ARs) contain the brightest and hottest coronal EUV (Extreme Ultra-Violet) loops - the core of an AR is typically the brightest structure inside the AR. In the present work we report fine-scale transient brightenings and flows in the coolest loops (the counterpart of chromospheric arch filament systems long observed in H-alpha filtergrams of bipolar emerging flux regions) seen in the core of an AR observed in 172 angstroms by Hi-C2.1 (High Resolution Coronal Imager, version 2.1). Some of these are rooted, at one of their feet, in mixed-polarity field in the photosphere. We complement the 5-min Hi-C2.1 data with SDO/AIA/HMI (Solar Dynamics Observatory / Atmospheric Imaging Assembly / Helioseismic and Magnetic Imager) and IRIS SJ (Interface Region Imaging Spectrograph Slit-Jaw) images and spectral data, and examine fine-scale events, flows and their photospheric magnetic field. We find counter streaming flows in the arch filament system, similar to that long observed in filaments. There are scattered fine-scale brightening events. Most, if not all, of these brightenings are at sites of converging opposite-polarity magnetic flux (implying flux cancellation, sometimes resulting from flux emergence). The fine-scale flows stem from some of the brightenings. Flux cancellation at these sites apparently results in fine-scale explosions that drive the counter streaming flows. In the IRIS spectra, we look for evidence of upflows from brightenings at ends of loops of the arch filament system.

Tiwari, Sanjiv K.↗

Surface Cancellation in Wideband Ground Penetrating Radar Employing Genetic Algorithm AI for Waveform Synthesis

This paper presents a wideband 600-1200 MHz ground penetrating radar (GPR) system for sub-surface exploration of the moon and other planetary bodies. The presented radar system uses an arbitrary waveform generator (AWG) to directly produce the frequency-modulated continuous wave (FMCW) chirp waveform. To address the key challenges of Tx-to-Rx leakage and surface reflections, the system uses a second AWG channel coupled directly to the receiver that provides a cancellation waveform to mitigate the unwanted signals. The system also uses a genetic algorithm AI engine which assesses the radar IF and iteratively improves the parameters of the cancellation waveform injected at the receiver.

Chang, Frank↗

Active noise canceling system for mechanically cooled germanium radiation detectors

A microphonics noise cancellation system and method for improving the energy resolution for mechanically cooled high-purity Germanium (HPGe) detector systems. A classical adaptive noise canceling digital processing system using an adaptive predictor is used in an MCA to attenuate the microphonics noise source making the system more deployable.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Noise canceling in-situ detection

Technologies applicable to noise canceling in-situ NMR detection and imaging are disclosed. An example noise canceling in-situ NMR detection apparatus may comprise one or more of a static magnetic field generator, an alternating magnetic field generator, an in-situ NMR detection device, an auxiliary noise detection device, and a computer.

42 ENGINEERING↗

Noise canceling in-situ NMR detection

Technologies applicable to noise canceling in-situ NMR detection and imaging are disclosed. An example noise canceling in-situ NMR detection apparatus may comprise one or more of a static magnetic field generator, an alternating magnetic field generator, an in-situ NMR detection device, an auxiliary noise detection device, and a computer.

Walsh, David O.↗

Cancellation of the ion deflection due to electron-suppression magnetic field in a negative-ion accelerator

A new magnetic configuration is proposed for the suppression of co-extracted electrons in a negative-ion accelerator. This configuration is produced by an arrangement of permanent magnets embedded in one accelerator grid and creates an asymmetric local magnetic field on the upstream and downstream sides of this grid. Thanks to the “concentration” of the magnetic field on the upstream side of the grid, the resulting deflection of the ions due to magnetic field can be “intrinsically” cancelled by calibrating the configuration of permanent magnets. At the same time, the suppression of co-extracted electrons can be improved.

43 PARTICLE ACCELERATORS↗

The effect of losses on the quantum-noise cancellation in the SU(1,1) interferometer

Quantum-noise cancellation (QNC) is an effective method to control the noise of the quantum system, which reduces or even eliminates the noise of the quantum systems by utilizing destructive interference in the quantum system. However, QNC can be extremely dependent on the losses inside the system. In this letter, we experimentally and theoretically study how the losses can affect the QNC in the SU(1,1) interferometer. We find that losses in the different arms inside the SU(1,1) interferometer can have different effects on the QNC in the output fields from the SU(1,1) interferometer. And the QNC in the SU(1,1) interferometer can almost be insensitive to the losses in some cases. Our findings may find its potential applications in the quantum noise control.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗