Quantitative assessment of fitting errors associated with streak camera noise in Thomson scattering data analysis

Thomson scattering measurements in high energy density experiments are often recorded using optical streak cameras. In the low-signal regime, noise introduced by the streak camera can become an important and sometimes the dominant source of measurement uncertainty. In this paper, we present a formal method of accounting for the presence of streak camera noise in our measurements. We present a phenomenological description of the noise generation mechanisms and present a statistical model that may be used to construct the covariance matrix associated with a given measurement. This model is benchmarked against simulations of streak camera images. We demonstrate how this covariance may then be used to weight fitting of the data and provide quantitative assessments of the uncertainty in the fitting parameters determined by the best fit to the data and build confidence in the ability to make statistically significant measurements in the low-signal regime, where spatial correlations in the noise become apparent. These methods will have general applicability to other measurements made using optical streak cameras.

47 OTHER INSTRUMENTATION↗

Evaluation of camera-based freehand SPECT in preoperative sentinel lymph node mapping for melanoma patients

Assessment of lymphatic status via sentinel lymph node (SLN) biopsy is an integral and crucial part of melanoma surgical oncology. The most common technique for sentinel node mapping is preoperative planar scintigraphy of an injected gamma-emitting lymphatic tracer followed by intraoperative node localization using a non-imaging gamma probe with auditory feedback. In recent years, intraoperative visualization of SLNs in 3D has become possible by coupling the probe to an external system capable of tracking its location and orientation as it is read out, thereby enabling computation of the 3D distribution of the tracer (freehand SPECT). In this project, the non-imaging probe of the fhSPECT system was replaced by a unique handheld gamma camera containing an array of sodium iodide crystals optically coupled to an array of silicon photomultipliers (SiPMs). A feasibility study was performed in which preoperative SLN mapping was performed using camera fhSPECT and the number of detected nodes was compared to that visualized by lymphoscintigraphy, probe fhSPECT, and to the number ultimately excised under non-imaging probe guidance. Among five subjects, SLNs were detected in nine lymphatic basins, with one to five SLNs detected per basin. A basin-by-basin comparison showed that the number of SLNs detected using camera fhSPECT exceeded that using lymphoscintigraphy and probe fhSPECT in seven of nine basins and five of five basins, respectively. (Probe fhSPECT scans were not performed for four basins.) It exceeded the number excised under non-imaging probe guidance for seven of nine basins and equaled the number excised for the other two basins. Freehand SPECT using a prototype SiPM-based gamma camera demonstrates high sensitivity for detection of SLNs in a preoperative setting. Camera fhSPECT is a potential means for efficiently obtaining real-time 3D activity distribution maps in applications such as image-guided percutaneous biopsy, and surgical SLN biopsy or radioguided tumor excision.

60 APPLIED LIFE SCIENCES↗

Stereo Cameras for Clouds (STEREOCAM) Instrument Handbook

The three pairs of stereo camera setups aim to provide synchronized and stereo calibrated time series of images that can be used for 3D cloud mask reconstruction. Each camera pair is positioned at approximately 120 degrees from the other pair, with a 17o-19o pitch angle from the ground, and at 5-6 km distance from the U.S. Department of Energy (DOE) Central Facility at the Atmospheric Radiation Measurement (ARM) Climate Research Facility Southern Great Plains (SGP) observatory to cover the region from northeast, northwest, and southern views. Images from both cameras of the same stereo setup can be paired together to obtain 3D reconstruction by triangulation. 3D reconstructions from the ring of three stereo pairs can be combined together to generate a 3D mask from surrounding views. This handbook delivers all stereo reconstruction parameters of the cameras necessary to make 3D reconstructions from the stereo camera images.

47 OTHER INSTRUMENTATION↗

Site-wide occupancy assessment using camera traps for seven mammalian species at Los Alamos National Laboratory

Los Alamos National Laboratory (LANL or Laboratory) is committed to solving national security challenges through scientific excellence and has been serving the nation and northern New Mexico for over 70 years. Being located on the Pajarito Plateau in the eastern flanks of the Jemez Mountains, the Laboratory is surrounded by a rich diversity of plants and animals. It is common to see many different species of wildlife on Laboratory property; however, sometimes interactions with wildlife can be negative. Vehicle accidents with wildlife have become a common occurrence. With the current and ongoing expansion of the Laboratory on the Pajarito Plateau, it has the potential to further impact wildlife movement including large game species. Local agencies and tribal Pueblos rely on large game species and do not want these species to be restricted from moving across property boundaries. Temporal and spatial aspects of where wildlife occur on the site is a phenomena that is either not well understood in uncommon species or needs periodic reevaluation for common species. Estimating the distribution of multiple species across the landscape provides wildlife biologists with crucial information for monitoring and conserving animal populations in a particular area. Utilizing motion activated wildlife cameras, also known as camera traps, to monitor wildlife populations has become an essential tool for biologists. Camera traps are non-invasive and cost-effective and can document multiple elusive or uncommon wildlife species, such as carnivores, simultaneously. Occupancy modeling provides a flexible framework for the analysis of the distribution for multiple wildlife species. It explicitly recognizes whether a species is spatially common or rare (occupancy = ψ) and if that species is easy or hard to detect (detection probability = p ). Multispecies and multi-season occupancy models can detect trends in species occupancy because individual species may vary in seasonal movements, detection probability, and transition rates between habitats. In this study, we assessed the site as a whole to ascertain when and where medium and large mammal species are present. Understanding wildlife patterns at the Laboratory will better inform future management decisions regarding land use and development strategies. We placed motion activated wildlife cameras in a random systematic sampling design and used these data to create occupancy models. We tested for differences in single-species occupancy and detection probability by season of mammal species captured on 20 camera traps placed across the Laboratory in a 40 mi² (103 km²) area. We focus the interpretation of our findings on seven mammal species found during this study. They are Rocky Mountain elk ( Cervus canadensis nelsoni ; hereafter “elk”), mule deer ( Odocoileus hemionus ; hereafter “deer”), mountain lion ( Puma concolor ; hereafter “lion”), American black bear ( Ursus americanus ; hereafter “bear”), coyote ( Canis latrans ), bobcat ( Lynx rufus ), and gray fox ( Urocyon cinereoargenteus ; hereafter “fox”).

59 BASIC BIOLOGICAL SCIENCES↗

Vegetation Warming Experiment: Landscape-scale digital camera imagery for vegetation phenology, Utqiagvik, Alaska, 2021

Images captured using a StarDot NetCam SC phenocamera looking east from the top of the Barrow Environmental Observatory (BEO) Sled Shed, Utqiagvik, Alaska. The camera was installed to remotely monitor plant phenology and operation of the Brookhaven National Laboratory (BNL) TEST group's ZPW (Zero Power Warming) chambers during the growing season of 2021. Images were captured from early spring (1 April) through to mid fall (22 October). Snowmelt, vegetation growth and senescence, and snow accumulation were captured. Images were uploaded to the BNL FTP server every hour, then from 2021-07-09 images were recorded every 10 minutes until the end of data collection on 2021-10-22. Images have been combined in *.zip format (6.1 GB). Closer fields of view (northeasterly) were also captured using 4 Wingscapes TimelapseCam cameras mounted on a mast on the sled shed. These cameras were operated from 2021-06-19 to 2021-09-22, with images recorded every 30 minutes from 9:00 to 16:30 Alaska daylight time (AKDT, UTC-8). Individual jpg images from each camera have been combined in zip format. The data package includes a metadata document with example fields of view from each camera (*.pdf). The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Advancements in the Camera Setup for Unsteady Pressure Sensitive Paint at NASA Ames Research Center

A test in the Unitary Plan Wind Tunnel at NASA Ames Research Center is scheduled for early 2024 with the intent of showcasing improvements made to unsteady Pressure Sensitive Paint technology. Analysis was performed to investigate how to maximize the system resolving power by optimizing the camera parameters, specifically focal length and focusing distance, while still subject to other system requirements such as field of view and relatively low illumination from the paint. Additionally, the system is upgrading to an 8-camera system from a 4-camera system, so analysis was performed to determine the best way to extend that system to maximize camera coverage and how to most effective reduce the system uncertainty by averaging multiple measurement using camera overlap. These analyses have uncovered new opportunities to improve the unsteady Pressure Sensitive Paint technology without the need for new or expensive hardware and will allow the system to collect better data with simple changes to the design process.

Camera Calibration↗

New Design Yields Robust Large-Area Framing Camera

Framing cameras provide a discrete series of images over a short period of time in a manner that mimics a high-speed movie camera, but with individual shutter times that must be extremely short in order to capture freeze-frame images of rapidly evolving phenomena such as high-explosive shock-driven ejecta, dynamic compression of metals, and high-velocity fluid flow. The NNSS has designed and fielded a new, large-area, gated framing camera called Kraken. The camera design emphasized manufacturability and flexibility by improving imager yield and creating a camera architecture to shorten design cycles. Design strategies and field data are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Predicting 3D Motions from Single-Camera Optical Test Data

In a typical optical test, a stereo camera pair is required to measure the three-dimensional motion of a test article; one camera typically only measures motions in the image plane of the camera, and measurements in the out-of-plane direction are missing. Finite element expansion techniques provide a path to estimate responses from a test at unmeasured degrees of freedom. Treating the case of a single camera as a measurement with unmeasured degrees of freedom, a finite element model is used to expand to the missing third dimension of the image data, allowing a full-field, three-dimensional measurement to be obtained from a set of images from a single camera. The key to this technique relies on the mapping of finite element deformations to image deformations, creating a set of mode shape images that are used to filter the response in the image into modal responses. These modal responses are then applied to the finite element model to estimate physical responses at all finite element model degrees of freedom. The mapping from finite element model to image is achieved using synthetic images produced by a rendering software. Finally, the technique is applied first to a synthetic deformation image, and then is validated using an experimental set of images.

47 OTHER INSTRUMENTATION↗

Scintillation event imaging with a single photon avalanche diode camera

Position and time measurements of scintillation events encode information about the radiation source. Single photon avalanche diode (SPAD) arrays offer multiple-megapixel spatial resolution and tens of picoseconds temporal resolution for detecting single photons. Current lensless designs for measuring scintillation events use sensors that are lower in spatial resolution. Camera-based designs use sensors that are lower in temporal resolution or readout rate and cannot image individual interactions. Here we propose to image scintillation events in a thick, monolithic scintillator using a high-resolution SPAD camera. We demonstrate that a commercial SPAD camera is able to gather sufficient signal to image individual scintillation events and observe 3D shifts in their spatial distribution. Simulations show that a SPAD camera can localize individual scintillation events in 3D. We report direct imaging of gamma-ray interactions in a scintillator with a SPAD camera. The proposed design may allow to measure complex signatures of individual particles interacting in the scintillator.

47 OTHER INSTRUMENTATION↗

A 1D Lyman-alpha profile camera for plasma edge neutral studies on the DIII-D tokamak

A one dimensional, absolutely calibrated pinhole camera system was installed on the DIII-D tokamak to measure edge Lyman-alpha (Ly-α) emission from hydrogen isotopes, which can be used to infer neutral density and ionization rate profiles. The system is composed of two cameras, each providing a toroidal fan of 20 lines of sight, viewing the plasma edge on the inboard and outboard side of DIII-D. The cameras’ views lie in a horizontal plane 77 cm below the midplane. At its tangency radius, each channel provides a radial resolution of ~2 cm full width at half maximum (FWHM) with a total coverage of 22 cm. Each camera consists of a rectangular pinhole, Ly-α reflective mirror, narrow-band Ly-α transmission filter, and a 20 channel AXUV photodetector. The combined mirror and transmission filter have a FWHM of 5 nm, centered near the Ly-α wavelength of 121.6nm and is capable of rejecting significant, parasitic carbon-III (C-III) emission from intrinsic plasma impurities. To provide a high spatial resolution measurement in a compact footprint, the camera utilizes advanced engineering and manufacturing techniques including 3D printing, high stability mirror mounts, and a novel alignment procedure. Absolutely calibrated, spatially resolved Ly-α brightness measurements utilize a bright, isolated line with low parasitic surface reflections and enable quantitative comparison to modeling to study divertor neutral leakage, main chamber fueling, and radial particle transport.

Ionization Rate↗

A multi-mass and multi-hit two-camera 3D ion momentum imaging system

We demonstrate an improved two-camera system for multi-mass and multi-hit three-dimensional (3D) momentum imaging of ions. The imaging system employs two conventional complementary metal–oxide–semiconductor cameras. We have shown previously that the system can time slice ion Newton spheres with a time resolution of 8.8 ns, limited by camera timing jitter [J. Chem. Phys., 158, 191104 (2023)]. In this work, a jitter correction method was developed to suppress the camera jitter and improve the time resolution to better than 2 ns. With this resolution, full 3D momentum distributions of ions can be obtained. We further show that this method can detect two ions with different masses when utilizing both the rising and falling edges of the cameras.

Instruments & Instrumentation↗

A Nonintrusive Optical Approach to Characterize Heliostats in Utility-Scale Power Tower Plants: Camera Position Sensitivity Analysis

Optics plays a major role in the effectiveness of concentrating solar power (CSP) technologies. The nonintrusive optical (NIO) approach developed by the National Renewable Energy Laboratory uses uncrewed aircraft system (UAS)-based imaging to survey heliostats in a commercial-scale power tower CSP plant and characterize their optical errors. The image processing algorithm uses photogrammetry to calculate the camera position for each image frame, and the accuracy of the estimated optical errors is highly sensitive to the calculated camera position accuracy. In this study, we simulate a series of case studies in python to examine the impact of different parameters of the sensitivity of the camera calculation, including the number of facet corners used as control points for the photogrammetric calculation, precision error in the detected pixel locations of the facet corners in the image, and precision error of the canting and mounting positions of the facets of the heliostat. The case studies consider heliostat geometry based on three commercial designs to serve as representative examples of different possible sizes of heliostats that the NIO method could be applied to. The results show that increasing the number of control points can improve accuracy for heliostats with many facets, pixel precision has a significantly larger impact on camera calculation accuracy than facet canting and mounting errors, and the camera distance and focal length must be chosen to ensure adequate pixel accuracy on the heliostat surface depending on the size of heliostat. In conclusion, based on the results, recommendations for the allowable values of each parameter are provided to achieve the required NIO optical error estimation accuracy depending on the size of heliostat.

14 SOLAR ENERGY↗

Large Game Distribution Camera Study at Los Alamos National Laboratory [Poster]

The unique habitats at the Laboratory support a diverse community of wildlife. The habitat types that include Pinon Juniper, Ponderosa Pine, and Mixed-conifer forests each provide different resources important for a variety of species. Wildlife monitoring for large game animals can be challenging because they avoid interactions with humans, and prefer undeveloped areas. This study was conducted to analyze the distribution of predators and other game animals seasonally across the Laboratory. The data gathered will be used to make recommendations regarding wildlife management for conservation and protection. Utilizing game cameras to remotely monitor wildlife was determined to be the most effective, noninvasive method to gather the necessary data. As camera technology has advanced, game cameras have become adequate for documenting individuals, and are commonly used in wildlife studies on predation, abundance, occupancy, diversity, and endangered species detection. Twenty cameras were placed across the LANL landscape using a modified systematic sampling design. They were deployed in February 2018 and retrieved in January 2019, thus each camera sampled for one full year. All images were reviewed and the species, number, age, and sex of all animals in the photo were recorded. Here we present data for the most abundant species encountered: deer, elk, coyote, bear, bobcat, mountain lion, and fox respectively. The data were summarized by species and season. Future work will include occupancy modelling for each species. This will allow the development of heat maps showing species distributions across the Laboratory.

54 ENVIRONMENTAL SCIENCES↗

Large Game Distribution Camera Study at Los Alamos National Laboratory

The unique habitats at the Laboratory support a diverse community of wildlife. The habitat types that include Pinon Juniper, Ponderosa Pine, and Mixed-conifer forests each provide different resources important for a variety of species. Wildlife monitoring for large game animals can be challenging because they avoid interactions with humans, and prefer undeveloped areas. This study was conducted to analyze the distribution of predators and other game animals seasonally across the Laboratory. This research informs decisions regarding wildlife management recommendations for conservation and protection. This study utilized game cameras to remotely monitor wildlife. As camera technology has advanced, game cameras have become adequate for documenting individuals, and are commonly used in wildlife studies on predation, abundance, occupancy, diversity, and endangered species detection. Twenty cameras were placed across the LANL landscape using a modified systematic sampling design. They were deployed in February 2018 and retrieved in January 2019, thus each camera sampled for one full year. All images were reviewed and the species, number, age, and sex of all animals in the photo were recorded. Here we present data for the most abundant species encountered: deer, elk, coyote, bear, bobcat, mountain lion, and fox respectively. The data were summarized by species and season. Future work will include occupancy modelling for each species. This will allow the development of heat maps showing species distributions across the Laboratory.

59 BASIC BIOLOGICAL SCIENCES↗

Neutron Positioning and Geometric Distortion Correction on the SNS SiPM Anger Camera

Neutron Anger cameras are scintillator-based thermal neutron detectors that utilize pixelated photosensors to read out visible light signals and position neutrons accurately They are versatile detectors that can cover large areas for diffraction instruments and offer high efficiency and sub-millimeter spatial resolution. Photomultiplier Tube (PMT) based cameras are installed on three instruments at Spallation Neutron Source (SNS). The next generation camera uses Silicon Photomultipliers (SiPMs) instead of PMTs, which allows for a more compact design and higher spatial resolution. In this report, the Gaussian least-squares position fitting method is described in detail, as well as the method used to correct for geometric distortions across the face of the camera. Results from neutron camera tests before and after the distortion correction are shown and the spatial resolution is quantified.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A 1D Lyman-alpha Profile Camera for Plasma Edge Neutral Studies on the DIII-D Tokamak

A one dimensional, absolutely calibrated pinhole camera system was installed on the DIII-D tokamak to measure edge Lyman-alpha (Ly-a) emission from hydrogenic isotopes which can be used to infer neutral density and ionization rate proles. The system is composed of two cameras, each providing a toroidal fan of twenty lines of sight, viewing the plasma edge on the inboard and outboard side of DIII-D. The cameras' views lie in a horizontal plane 77 cm below the midplane. At its tangency radius, each channel provides a radial resolution of approximately 2 cm full width at half maximum (FWHM) with a total coverage of 22 cm. Each camera consists of a rectangular pinhole, Ly-a reflective mirror, narrow-band Ly-a transmission fiter, and a 20 channel AXUV photodetector. The combined mirror and transmission fiter have a FWHM of 5 nm, centered near the Ly-a wavelength of 121.6 nm and is capable of rejecting significant, parasitic carbon-III (C-III) emission from intrinsic plasma impurities. To provide a high spatial resolution measurement in a compact footprint, the camera utilizes advanced engineering and manufacturing techniques including 3D printing, high stability mirror mounts, and a novel alignment procedure. Absolutely calibrated, spatially resolved Ly-a brightness measurements utilize a bright, isolated line with low parasitic surface reflections and enable quantitative comparison to modeling to study divertor neutral leakage, main chamber fueling and radial particle transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance evaluation of the two-inch return-beam vidicon three-camera subsystem.

A very-high resolution multispectral television camera system is being developed for NASA for use on the Earth Resources Technology Satellite (ERTS) program. There are three cameras in the system, each viewing the same area but operating in the blue-green, red and near-infrared spectral bands. In the laboratory the cameras' limiting resolution is 4500 TV lines over the 25 x 25-mm image format of the Return Beam Vidicon (RBV). Analysis of typical ERTS scenes shows that actual contrast ratios will be much lower than those of laboratory test targets. A model was developed to predict the resolving power performance of the RBV camera under realistic conditions. The methods used are applicable to all types of imaging systems. To verify the model, tests were conducted using the RBV camera, a laser-beam image reproducer and a series of AF tribar test patterns of known values of contrast. As a more graphic demonstration, simulated multispectral images were generated using color-IR photographs from Apollo 9.

Miller, B. P.↗

Accuracy, resolution, and cost comparisons between small format and mapping cameras for environmental mapping

Successful aerial photography depends on aerial cameras providing acceptable photographs within cost restrictions of the job. For topographic mapping where ultimate accuracy is required only large format mapping cameras will suffice. For mapping environmental patterns of vegetation, soils, or water pollution, 9-inch cameras often exceed accuracy and cost requirements, and small formats may be better. In choosing the best camera for environmental mapping, relative capabilities and costs must be understood. This study compares resolution, photo interpretation potential, metric accuracy, and cost of 9-inch, 70mm, and 35mm cameras for obtaining simultaneous color and color infrared photography for environmental mapping purposes.

Clegg, R. H.↗