Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CALORIMETRY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

CMS Forward Calorimetry R&D

This is a technical scope of work (TSW) between the Fermi National Accelerator Laboratory (Fermilab) and the experimenters of the CMS Forward Calorimetry Taskforce (FCAL group) who have committed to participate in beam tests to be carried out during the 2013-2016 Fermilab Test Beam Facility program. The TSW is intended primarily for the purpose of recording expectations for budget estimates and work allocations for Fermilab, the funding agencies and the participating institutions. It reflects an arrangement that currently is satisfactory to the parties; however, it is recognized and anticipated that changing circumstances of the evolving research program will necessitate revisions. The parties agree to modify this scope of work to reflect such required adjustments. Actual contractual obligations will be set forth in separate documents.

Bilki, Burak↗

Investigating the Thermal Behavior of Polymers by Modulated Differential Scanning Calorimetry (MDSC) – A Review

Modulated Differential Scanning Calorimetry (MDSC) is a thermoanalytical technique that detects changes in intrinsic heat flow by subjecting a material to two simultaneous heating rates, one linear and one sinusoidal. In this way, MDSC overcomes the limitations of its predecessor- conventional DSC-allowing for complex and overlapping thermal transitions to be resolved without sacrificing sensitivity. The advantages of MDSC lend credence to its extensive use in applications that require superior analytical accuracy, such as the food and drug industries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Crystal Calorimetry for Charged Lepton Flavor Violation Searches

The Mu2e experiment at Fermilab aims to search for Charged Lepton Flavor Violation (CLFV) through the coherent conversion of a muon into an electron in the field of an aluminum nucleus. This process, highly suppressed in the Standard Model, would clearly indicate new physics if observed. A crucial component of Mu2e is its electromagnetic calorimeter, which enhances the identification and measurement of conversion electrons. The calorimeter consists of two disks of undoped CsI crystals read out by custom-designed SiPMs and fast front-end electronics. This paper presents an overview of the calorimeter’s design, its custom SiPM technology, the readout and data acquisition system, and the results from commissioning tests.Building on the experience from Mu2e, the proposed Mu2e-II upgrade aims to enhance further the experiment’s sensitivity by an order of magnitude. This requires significant advancements in calorimeter technology, particularly in crystal materials and photodetector performance. Studies on BaF$_2$ and LYSO crystals, as well as the development of radiation-hard Silicon Photomultipliers (SiPMs), are currently underway. Test beam results demonstrate promising improvements in energy resolution and timing capabilities, ensuring the feasibility of next-generation calorimetry solutions for Mu2e-II.

Atanov, N. [Dubna, JINR]↗

The (Un)reasonable Effectiveness of Neural Network in Cherenkov Calorimetry

We report a greater than factor of two improvement in the hadronic energy resolution of a simulated Cherenkov calorimeter by estimating the energy with machine learning over traditional techniques. The prompt signal formation and energy threshold properties of Cherenkov radiation provide identifiable features that machine learning techniques can exploit to produce a superior model for energy reconstruction. We simulated a quartz-fiber calorimeter via the GEANT4 framework to study the reconstruction techniques in single events. We compared the machine learning-based reconstruction performance to the traditional simple sum of signal and dual-readout techniques that use both Cherenkov and scintillation signals. We describe why this game-changing approach to Cherenkov hadron calorimetry excels and our plans for a dedicated beam test to validate these findings with a fast, radiation-hard hadron calorimeter prototype.

Akchurin, Nural↗

Automatic calorimetry system monitors RF power

Calorimetry system monitors the average power dissipated in a high power RF transmitter. Sensors measure the change in temperature and the flow rate of the coolant, while a multiplier computes the power dissipated in the RF load.

Harness, B. W.↗

Neutron monitoring and electrode calorimetry experiments in the HIP-1 Hot Ion Plasma

Results are presented for two diagnostic procedures on HIP-1: neutron diagnostics to determine where neutrons originated within the plasma discharge chamber and electrode calorimetry to measure the steady-state power absorbed by the two anodes and cathodes. Results are also reported for a hot-ion plasma formed with a continuous-cathode rod, one that spans the full length of the test section, in place of the two hollow cathodes. The outboard neutron source strength increased relative to that at the midplane when (1) the cathode tips were moved farther outboard, (2) the anode diameters were increased, and (3) one of the anodes was removed. The distribution of neutron sources within the plasma discharge chamber was insensitive to the division of current between the two cathodes. For the continuous cathode, increasing the discharge current increased the midplane neutron source strength relative to the outboard source strength. Each cathode absorbed from 12 to 15 percent of the input power regardless of the division of current between the cathodes. The anodes absorbed from 20 to 40 percent of the input power. The division of power absorption between the anodes varied with plasma operating conditions and electrode placement.

Reinmann, J. J.↗

Differential scanning calorimetry of coal

Differential scanning calorimetry studies performed during the first year of this project demonstrated the occurrence of exothermic reactions associated with the production of volatile matter in or near the plastic region. The temperature and magnitude of the exothermic peak were observed to be strongly affected by the heating rate, sample mass and, to a lesser extent, by sample particle size. Thermal properties also were found to be influenced by oxidation of the coal sample due to weathering effects.

Gold, P. I.↗

Accelerating rate calorimetry: A new technique for safety studies in lithium systems

The role of exothermic reactions in battery test modes is discussed. The exothermic reactions are characterized with respect to their time-temperature and time-pressure behavior. Reactions occuring for any major exotherm were examined. The accelerating rate calorimetry methods was developed to study lithium cells susceptibility to thermal runaway reactions following certain abuse modes such as forced discharge into reversal and charging.

Ebner, W. B.↗

Cure kinetics of epoxy matrix resin by differential scanning calorimetry

A study was made on the cure kinetics of an epoxy neat-resin (Narmco 5208) using Differential Scanning Calorimetry (DSC). Two interrelated analytical methods were applied to dynamic DSC data for evaluating the kinetic parameters, such as activation energy, E, the order of reaction, n, and the total heat of polymerization (or crosslinking), delta H sub t. The first method was proposed by Ellerstein (1968), and uses a thorough differential-integral analysis of a single DSC curve to evaluate the kinetic parameters. The second method was proposed by Kissinger (1957), and uses multiple DSC curves obtained at various heating rates to evaluate E regardless of n. Kinetic analysis of Narmco 5208 epoxy resin showed that the reaction order, n, is substantially affected by the rate of heating; i.e., n is approximately 2 at slow scan rates but is reduced to 1.5 at higher scan rates. The activation energy, E, is not affected by the scan rate, and the average value of E is 25.6 + or - 1.8 kcal/mole.

Cizmecioglu, M.↗