Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Buffalo”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Modeling the Life Cycle Impacts of U.S. Coal Mining at a Regional Level - ISSST2018

This work was presented at the International Symposium on Sustainable Systems and Transportation (ISSST) 2018 Conference in Buffalo, NY on June 27, 2018. This model allows for the characterization of environmental impacts from the extraction, processing, and transportation of coal from mines to power plants. It identifies environmental reduction opportunities that can enable coal to be competitive with other energy resources on an environmental impact basis. It also establishes an environmental footprint per unit of coal for the various combinations of coal basins, mine types, and coal types, as wells as a national average footprint. This work models environmental impacts for a comprehensive life cycle inventory that is sufficiently representative to run the TRACI impact assessment method and generate comparative results. <strong>Select results have been updated (2023) in the presentation to reflect current modeling choices in the coal model. See new slide 26 for more detail.</strong>

Carlson, Derrick R.↗

Implementation of a DOD ELAP Conforming Quality System at a FUSRAP Site Field Temporary Radiological Screening Laboratory - 13500

A case study is presented on specific program elements that supported the transition of a temporary field radiological screening lab to an accredited operation capable of meeting client quality objectives for definitive results data. The temporary field lab is located at the Formerly Utilized Sites Remedial Action Program Linde Site in Tonawanda, NY. The site is undergoing remediation under the direction of the United States Army Corps of Engineers - Buffalo District, with Cabrera Services Inc. as the remediation contractor and operator of the on-site lab. Analysis methods employed in the on-site lab include gross counting of alpha and beta particle activity on swipes and air filters and gamma spectroscopy of soils and other solid samples. A discussion of key program elements and lessons learned may help other organizations considering pursuit of accreditation for on-site screening laboratories. (authors)

54 ENVIRONMENTAL SCIENCES↗

Linde FUSRAP Site Remediation: Engineering Challenges and Solutions of Remedial Activities on an Active Industrial Facility - 13506

The Linde FUSRAP Site (Linde) is located in Tonawanda, New York at a major research and development facility for Praxair, Inc. (Praxair). Successful remediation activities at Linde combines meeting cleanup objectives of radiological contamination while minimizing impacts to Praxair business operations. The unique use of Praxair's property coupled with an array of active and abandoned utilities poses many engineering and operational challenges; each of which has been overcome during the remedial action at Linde. The U.S. Army Corps of Engineers - Buffalo District (USACE) and CABRERA SERVICES, INC. (CABRERA) have successfully faced engineering challenges such as relocation of an aboveground structure, structural protection of an active water line, and installation of active mechanical, electrical, and communication utilities to perform remediation. As remediation nears completion, continued success of engineering challenges is critical as remaining activities exist in the vicinity of infrastructure essential to business operations; an electrical substation and duct bank providing power throughout the Praxair facility. Emphasis on engineering and operations through final remediation and into site restoration will allow for the safe and successful completion of the project. (authors)

54 ENVIRONMENTAL SCIENCES↗

Soil Segregation Methods for Reducing Transportation and Disposal Costs - 13544

At Formerly Utilized Sites Remedial Action Program (FUSRAP) sites where the selected alternative for contaminated soil is excavation and off-site disposal, the most significant budget items of the remedial action are the costs for transportation and disposal of soil at an off-site facility. At these sites, the objective is to excavate and dispose of only those soils that exceed derived concentration guideline levels. In situ soil segregation using gross gamma detectors to guide the excavation is often challenging at sites where the soil contamination is overlain by clean soil or where the contaminated soil is located in isolated, subsurface pockets. In addition, data gaps are often identified during the alternative evaluation and selection process, resulting in increased uncertainty in the extent of subsurface contamination. In response, the U.S. Army Corps of Engineers, Buffalo District is implementing ex situ soil segregation methods. At the remediated Painesville Site, soils were excavated and fed through a conveyor-belt system, which automatically segregated them into above- and below-cleanup criteria discharge piles utilizing gamma spectroscopy. At the Linde Site and the Shallow Land Disposal Area (SLDA) Site, which are both in the remediation phase, soils are initially segregated during the excavation process using gross gamma detectors and then transported to a pad for confirmatory manual surveying and sampling. At the Linde Site, the ex situ soils are analyzed on the basis of a site-specific method, to establish compliance with beneficial reuse criteria that were developed for the Linde remediation. At the SLDA Site, the ex situ soils are surveyed and sampled based on Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM) final status survey guidance to demonstrate compliance with the derived concentration guideline levels. At all three sites, the ex situ soils that meet the site- specific DCGLs are retained on-site and used as backfill material. This paper describes the ex situ soil segregation methods, the considerations of each method, and the estimated cost savings from minimizing the volume of soil requiring transportation and off-site disposal. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Uranium Fate and Transport Modeling, Guterl Specialty Steel Site, New York - 13545

The Former Guterl Specialty Steel Corporation Site (Guterl Site) is located 32 kilometers (20 miles) northeast of Buffalo, New York, in Lockport, Niagara County, New York. Between 1948 and 1952, up to 15,875 metric tons (35 million pounds) of natural uranium metal (U) were processed at the former Guterl Specialty Steel Corporation site in Lockport, New York. The resulting dust, thermal scale, mill shavings and associated land disposal contaminated both the facility and on-site soils. Uranium subsequently impacted groundwater and a fully developed plume exists below the site. Uranium transport from the site involves legacy on-site pickling fluid handling, the leaching of uranium from soil to groundwater, and the groundwater transport of dissolved uranium to the Erie Canal. Groundwater fate and transport modeling was performed to assess the transfer of dissolved uranium from the contaminated soils and buildings to groundwater and subsequently to the nearby Erie Canal. The modeling provides a tool to determine if the uranium contamination could potentially affect human receptors in the vicinity of the site. Groundwater underlying the site and in the surrounding area generally flows southeasterly towards the Erie Canal; locally, groundwater is not used as a drinking water resource. The risk to human health was evaluated outside the Guterl Site boundary from the possibility of impacted groundwater discharging to and mixing with the Erie Canal waters. This condition was evaluated because canal water is infrequently used as an emergency water supply for the City of Lockport via an intake located approximately 122 meters (m) (400 feet [ft]) southeast of the Guterl Site. Modeling was performed to assess whether mixing of groundwater with surface water in the Erie Canal could result in levels of uranium exceeding the U.S. Environmental Protection Agency (USEPA) established drinking water standard for total uranium; the Maximum Concentration Limit (MCL). Geotechnical test data indicate that the major portion of uranium in the soil will adsorb or remain bound to soil, yet leaching to groundwater appears as an on-site source. Soil leaching was modeled using low adsorption factors to replicate worst-case conditions where the uranium leaches to the groundwater. Results indicate that even after several decades, which is the period of time since uranium was processed at the Guterl Site, leaching from soil does not fully account for the currently observed levels of groundwater contamination. Modeling results suggest that there were historic releases of uranium from processing operations directly to the shallow fractured rock and possibly other geochemical conditions that have produced the current groundwater contamination. Groundwater data collected at the site between 1997 and 2011 do not indicate an increasing level of uranium in the main plume, thus the uranium adsorbed to the soil is in equilibrium with the groundwater geochemistry and transport conditions. Consequently, increases in the overall plume concentration or size are not expected. Groundwater flowing through fractures under the Guterl Site transports dissolved uranium from the site to the Erie Canal, where the groundwater has been observed to seep from the northern canal wall at some locations. The seeps discharge uranium at concentrations near or below the MCL to the Erie Canal. Conservative mixing calculations were performed using two worst-case assumptions: 1) the seeps were calculated as contiguous discharges from the Erie Canal wall and 2) the uranium concentration of the seepage is 274 micrograms per liter (μg/L) of uranium, which is the highest on-site uranium concentration in groundwater and nearly ten-fold the actual seep concentrations. The results indicate that uranium concentrations in the seep water would have to be more than 200 times greater than the highest observed on-site groundwater concentrations (or nearly 55,000 μg/L) to potentially exceed the drinking water standard (the MCL) for total uranium in the Erie Canal. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

In-Situ Radiological Surveys to Address Nuclear Criticality Safety Requirements During Remediation Activities at the Shallow Land Disposal Area, Armstrong County, Pennsylvania - 12268

Cabrera Services Inc. (CABRERA) is the remedial contractor for the Shallow Land Disposal Area (SLDA) Site in Armstrong County Pennsylvania, a United States (US) Army Corps of Engineers - Buffalo District (USACE) contract. The remediation is being completed under the USACE's Formerly Utilized Sites Remedial Action Program (FUSRAP) which was established to identify, investigate, and clean up or control sites previously used by the Atomic Energy Commission (AEC) and its predecessor, the Manhattan Engineer District (MED). As part of the management of the FUSRAP, the USACE is overseeing investigation and remediation of radiological contamination at the SLDA Site in accordance with the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA), 42 US Code (USC), Section 9601 et. seq, as amended and, the National Oil and Hazardous Substance Pollution Contingency Plan (NCP), Title 40 of the Code of Federal Regulations (CFR) Section 300.430(f) (2). The objective of this project is to clean up radioactive waste at SLDA. The radioactive waste contains special nuclear material (SNM), primarily U-235, in 10 burial trenches, Cabrera duties include processing, packaging and transporting the waste to an offsite disposal facility in accordance with the selected remedial alternative as defined in the Final Record of Decision (USACE, 2007). Of particular importance during the remediation is the need to address nuclear criticality safety (NCS) controls for the safe exhumation and management of waste containing fissile materials. The partnership between Cabrera Services, Inc. and Measutronics Corporation led to the development of a valuable survey tool and operating procedure that are essential components of the SLDA Criticality Safety and Material Control and Accountability programs. Using proven existing technologies in the design and manufacture of the Mobile Survey Cart, the continued deployment of the Cart will allow for an efficient and reliable methodology to allow for the safe exhumation of the Special Nuclear Material in existing SLDA trenches. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Successful Implementation of Soil Segregation Technology at the Painesville FUSRAP Site - 12281

Typically the highest cost component of the radiological soils remediation of Formerly Utilized Sites Remedial Action Program (FUSRAP) sites is the cost to transport and dispose of the excavated soils, typically contaminated with naturally occurring isotopes of uranium, thorium and radium, at an appropriately permitted off-site disposal facility. The heterogeneous nature of the contamination encountered at these sites makes it difficult to accurately delineate the extent of contaminated soil using the limited, discrete sampling data collected during the investigation phases; and difficult to precisely excavate only the contaminated soil that is above the established cleanup limits using standard in-field scanning and guiding methodologies. This usually results in a conservative guided excavation to ensure cleanup criteria are met, with the attendant transportation and disposal costs for the larger volumes of soil excavated. To address this issue during the remediation of the Painesville FUSRAP Site, located in Painesville, Ohio, the Buffalo District of the U.S. Army Corps of Engineers, and its contractor, Safety and Ecology Corporation (SEC), employed automatic soil segregation technology provided by MACTEC (now AMEC) to reduce the potential for transportation and disposal of soils that met the cleanup limits. This waste minimization technology utilized gamma spectroscopy of conveyor-fed soils to automatically segregate the material into above and below criteria discharge piles. Use of the soil segregation system resulted in cost savings through the significant reduction of the volume of excavated soil that required off-site transportation and disposal, and the reduction of the amount of imported clean backfill required via reuse of 'below criteria' segregated soil as place back material in restoring the excavations. Measurements taken by the soil segregation system, as well as results of quality control sampling of segregated soils, confirmed that soils segregated as below criteria for reuse as site fill did meet the Record of Decision cleanup criteria for the site. Automatic soil segregation technology was successfully implemented as part of the 2010 - 2011 remediation effort at the Painesville FUSRAP Site. The Orion ScanSortSM system employed at the site demonstrated the ability to accurately determine the radioactivity concentrations in the processed soil and soil-like material and quickly segregate that material for appropriate final disposition. Data from the soil segregation system and confirmatory QC samples indicated that the segregated 'below criteria' soils met the cleanup criteria in the ROD, and was appropriate for reuse as fill in the excavations. The reduction of the total excavated soil volume requiring off-site disposal by 94% yielded significant project cost savings through reduction of transportation and disposal and backfill procurement costs. Use of automatic soil segregation technology was an efficient and cost-effective method for addressing the radiological contamination at the Painesville Site. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Phyto-screening for Volatile Organic Compounds in a Clay-based Glacial Till at the Niagara Falls Storage Site, New York - 17372

The Niagara Falls Storage Site (NFSS) and associated vicinity properties (VPs) occupy approximately 607 hectares (1,500 acres) of the original 3,035-hectare (7,500-acre) Lake Ontario Ordnance Works (LOOW). The NFSS was used to store radioactive materials, residues and waste from uranium ore processing between 1944 and 1952. The waste-handling practices produced an array of groundwater impacts throughout the site. Although the groundwater at the NFSS is naturally high in total dissolved solids that preclude untreated consumption, the groundwater contaminant levels in some areas of the site are very high and may pose risk to a Construction Worker receptor, as well as limit the options for future site re-use. Volatile organic compound (VOC) impacted soil in the northern portion of the site has produced a groundwater plume with significant concentrations of tetrachloroethene (PCE) and associated daughter compounds. Active groundwater remediation is impractical due to the clayey soils, as evident from adjacent property owners who have unsuccessfully attempted active remediation of their VOC plumes. Consequently, the Buffalo District may evaluate excavation options, with secondary phyto-remediative approaches as passive alternatives to lessen the groundwater impacts during the project's life cycle. A preliminary field-study in the VOC plume area sampled the interior of a Black Locust (Robinia pseudoacacia) tree using a Haglof tree corer. Detectable levels of tetrachloroethene (PCE), trichloroethene (TCE), and cis-1,2,-dichloroethene (cis-DCE) were found in the woody interior of the tree. Subsequent sampling and analyses were performed on proximal trees of varying species in and around the currently delineated VOC plume. The results indicate that poplar and native cottonwood variants preferentially contain the VOCs, whereas collocated hardwood trees produced non-detectable results. Additional sampling of Cottonwoods in the VOC-impacted area promoted further delineations of the impacts. The tree-sampling data can be considered a broad surrogate for soil sampling to optimally delineate the VOC plume without performing additional invasive sampling of the subsurface (e.g., drilling). The results also will be used to determine which native tree species preferentially uptake the VOCs from soil and groundwater. These species, and possibly other hybrid species known for VOC uptake and transpiration, would be propagated to promote interim phyto-extraction of the VOCs during the maintenance period between decision-document completion and likely remedial action under the Formerly Utilized Sites Remedial Action Program (FUSRAP). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hydrogeologic modeling and the development of preliminary remediation goals for the Guterl Specialty Steel Site, New York - 15431

The Former Guterl Specialty Steel Corporation Site (Guterl Site) is located 32 kilometers (20 miles) northeast of Buffalo, New York, in Lockport, Niagara County, New York. Between 1948 and 1952, up to 15,875 metric tons (35 million pounds) of natural uranium metal (U) were processed at the Guterl Site. The resulting milling dust, shavings, thermal scale, and associated on-site land disposal contaminated both the facility and soils. These combined manufacturing and disposal processes promoted the development of a large-scale uranium plume in the groundwater underlying the site. Site soils are anthropogenic fill and re-worked, glacially-derived sediments that vary between 0.6 meters (m) and 3 meters (2.0 to 10.0 feet [ft]) in thickness. These soils blanket a highly permeable weathered and fractured zone in the upper Lockport Dolostone bedrock. Aerial recharge through the thin soils flushes soluble constituents to groundwater, as exemplified by variations in specific conductivity and groundwater levels in the bedrock during precipitation events. Seasonally higher groundwater levels also promote contact with uranium contamination in deeper soil, thus complicating the transport characteristics of the site (e.g., oxidizing metallic uranium in the soil that increases leach rates). The Seasonal Soil (SESOIL) compartment model was used to simulate a series of site soil conditions and predict the leaching of uranium to groundwater. The SESOIL input included physical soil characteristics, uranium profiles common in five soil areas, climate data, and an assumed oxidation-state (or chemical valence) for metallic uranium in the soil. The iterative modeling process evaluated site-specific variables to achieve a final deterministic set of input that was applied to the five soil areas. The leaching simulations estimated time-dependent influx rates for uranium, which were input to a numerical groundwater flow (MODFLOW) and transport (MT3DMS) model. The combined modeling effort produced spatially and temporally variable transport conditions that were simulated over a 1,000-year period. The leaching models predicted a preliminary remediation goal (PRG) for uranium of 11 milligrams per kilogram (mg/kg) that is protective of groundwater. However, this low uranium PRG has field implementation concerns, so a modified direct-exposure PRG of 70 mg/kg was developed and evaluated in the flow and transport model. The primary difference in the PRGs is the longevity and location of the uranium plume, which will affect the remedial costs and potential stakeholder acceptance. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Niagara Falls Storage Site - Balance of plant investigation results - 15432

The Niagara Falls Storage Site (NFSS) is a 77.3-hectare (ha) (191-acre) property that is owned by the United States Government and located in the township of Lewiston, Niagara County, New York. The NFSS is part of the former Lake Ontario Ordnance Works (LOOW) that was used by the War Department beginning in 1942 for the production of trinitrotoluene (TNT). During the 1940's and 1950's, the Manhattan Engineer District and the Atomic Energy Commission brought various radioactive wastes and uranium processing byproducts (residues) resulting from our nation's atomic energy program to the LOOW for storage. Site operations caused soil, sediment, and groundwater contamination that lead to several remedial actions, which culminated in the construction of the Interim Waste Containment Structure (IWCS) on the NFSS. The U. S. Army Corps of Engineers (USACE)-Buffalo District is the lead Federal agency for Formerly Utilized Sites Remedial Action Program (FUSRAP) remediation of the NFSS. As the lead agency, USACE is conducting a remedial investigation/feasibility study (RI/FS) pursuant to the protocols set forth in the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA). CERCLA activities at the NFSS have transitioned from the site RI activities to the FS evaluation of potential remediation alternatives. USACE recognizes the need to implement a focused CERCLA FS process and, therefore, has established three separate operable units (OUs) for NFSS: the IWCS OU, the Balance of Plant (BOP) OU [i.e., all on-site areas outside the boundary of the IWCS], and the Groundwater OU. This paper details recent investigations into the underground utilities, groundwater/soil contamination, and past storage of contaminated material on the Balance of Plant Operable Unit of the NFSS. Recent fieldwork activities have investigated areas of elevated groundwater contamination as well as an investigation to determine/eliminate any preferential pathway that historical underground utilities may have provided on-site in these areas. Additional areas of investigation included strategic placement of groundwater wells at locations of historic residue storage piles and intersections of various underground utilities (based on aerial photography and geophysical surveys). Several hundred locations across the site were investigated with a gamma walk-over survey, boring, surveying and sampling of soil-cores to aide in the delineation of soil contamination throughout the Balance of Plant Operable Unit. The series of investigations indicated multiple operational areas still have impacts above background conditions, risk-based concentrations, and promulgated maximum contaminant levels for multiple media in the Balance of Plant Operable Unit. The soil, groundwater, sediment, and utility sampling data show that 1) radionuclide impacts derived from ore-residue handling operations still exist, 2) impacts from other inorganic and organic compound exist in TNT manufacturing and support areas, and 3) contaminant transport from past source areas is minimal. The full compendium of site history and recent sampling data provides a well-defined conceptual site model that provides the necessary input data to prepare volumetric soil estimates for the Balance of Plant Operable Unit Feasibility Study. The scale of the NFSS and complexity of prior operations provide many remedial challenges. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Site closeout of the Linde FUSRAP Site, Tonawanda, New York - 15441

The US Army Corps of Engineers (USACE) Buffalo District, with assistance from Argonne National Laboratory (Argonne), prepared a Site Closeout Report (SCOR) for the Linde Formerly Utilized Sites Remedial Action Program (FUSRAP) Site in accordance with Engineer Regulation (ER) 200-1-4 [1]. Under FUSRAP, USACE is authorized to investigate, and clean up or control sites contaminated as the result of actions by the Atomic Energy Commission (AEC) and its predecessor, the Manhattan Engineer District (MED), in support of the nation's early atomic energy and weapons program. The SCOR documents response actions conducted at the Linde FUSRAP Site between 1996 and 2013. These response actions include two non-time-critical removal actions and long-term remedies associated with the three operable units (OUs) at the site: 1) soils and structure surfaces (except Building 14), 2) Building 14, and 3) groundwater. The report summarizes the site history, previous investigations, selected remedies, remedial actions, waste disposal, community involvement, monitoring results, recycling, quality assurance/quality control practices, post-remediation dose assessment, remedial costs, and five year review requirements. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation and Application of Phyto-remediation at FUSRAP Projects - 16275

The Niagara Falls Storage Site (NFSS) and associated vicinity properties (VPs) occupy approximately 607 hectares (1,500 acres) of the original 3,035-hectare (7,500-acre) Lake Ontario Ordnance Works (LOOW). The NFSS was used to store radioactive materials, residues and waste from uranium ore processing between 1944 and 1952. A field-study is currently underway to evaluate the potential use of hybridized trees to stabilize radionuclides, mainly uranium, and chlorinated solvents derived from trichloroethylene degradation in groundwater at the NFSS. The purpose of this effort is to support the USACE-Buffalo District in the evaluation and implementation of phyto-remediation approaches to contain groundwater impacts on the site. This demonstration project is considered a site maintenance action and will have relevance to the Formerly Utilized Sites Remedial Action Program (FUSRAP) mission. The demonstration is designed to determine the ability of trees to withstand and uptake Uranium (U), and to a lesser extent Trichloroethylenes (TCEs), and hydraulically control groundwater where historical practices produced a series of disconnect plumes. Although the groundwater at the NFSS is naturally high in total dissolved solids that preclude untreated consumption, the groundwater contaminant levels are very high in some areas and may limit the options for future site re-use. Active groundwater remediation is impractical due to the clayey site soils and low risk of transport. The phyto-remediative approach is a passive action to lessen the groundwater impacts during the project's life cycle and property re-use planning. The target contaminant sources and plumes occur near the property boundaries, along legacy sanitary sewer lines, and near on-site surface-water courses. The demonstration includes soil characteristic determinations, the testing of optimal hybrid tree species, field implementation at target sites, and soil moisture and groundwater monitoring during the long-term evaluation phase. The final disposition of the trees will be included in future site decision and maintenance documents. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Preliminary Probabilistic Performance Assessment Model for Radiological and Chemical Contamination at the West Valley Site, New York - 19295

The New York State Energy Research and Development Authority (NYSERDA) is the owner of the Western New York Nuclear Service Center (WNYNSC), a 1,351-ha site located approximately 48 km south of Buffalo, New York. In 1962, Nuclear Fuel Services, Inc. (NFS) entered into agreements with the Atomic Energy Commission and New York State to construct the first commercial reprocessing plant of nuclear fuel in the United States at the WNYNSC. NFS built and operated the spent fuel reprocessing plant and waste disposal facilities, processing 640 Mg (640 metric tons) of spent nuclear fuel from 1966 to 1972 under an Atomic Energy Commission license. Nuclear fuel reprocessing operations halted in 1972 and never restarted, leaving behind radioactive and chemical wastes. The reprocessing wastes include high-level waste (HLW), so U.S. Department of Energy (DOE) was compelled to complete certain waste management activities under the West Valley Demonstration Project (WVDP) Act of 1980, including decommissioning of WVDP facilities. As collaborating agencies, NYSERDA and the DOE are tasked with making decisions about decommissioning and risk reduction for the West Valley Site. Neptune and Company, Inc. (Neptune) was contracted to develop a probabilistic performance assessment (PPA) model to assist the agencies in their decision making process for decommissioning the WVDP and WNYNSC. One important tool that is needed in order to inform the decision-making process is a science-based model of the contamination at the West Valley Site and its potential implications for human health and the environment. The West Valley PPA Model (the Model), developed using the GoldSim modeling software, is a tool intended to provide support for decision making with uncertainty, in a manner that is transparent, defensible, and robust. The PPA Model includes contaminant transport and health effects components, and is organized around geographically-organized contaminated facilities. These include the waste disposal areas licensed by the U.S. Nuclear Regulatory Commission and the State of New York, a waste tank farm for storage of HLW resulting from reprocessing operations, and several areas contaminated with radioactive and chemical constituents. The Model evaluates contaminant transport from these sources to points of exposure across the site and into receiving surface waters and sediments. Hypothetical people and wildlife are exposed to contamination at these locations, and the effects of these exposures are evaluated. Contaminant transport processes to be evaluated in the Model include groundwater and surface water transport, contaminant translocation by plants and animals, diffusion in subsurface air and water, and erosion of the Site. The evaluation of exposures to people in this preliminary model is limited to a resident farmer scenario, and ecological assessment is performed at the level of a screening analysis. The results of these preliminary evaluations inform future model developments. Model results are subjected to sensitivity analysis in order to determine those pathways and parameters that are most significant in influencing the results. This information allows analysts and decision makers to focus on those aspects of Site behavior and processes that contribute most to overall uncertainty. With this information, the Supplemental Environmental Impact Statement (SEIS) can inform defensible decisions regarding remediation of the Site. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A GIS-Based Suitability Analysis of a Phytomanagment Strategy for TCE in Groundwater and Soil Niagara Falls Storage Site, New York - 19385

The large number of complexly contaminated sites throughout the nation has propagated the application of phytoremedial techniques in a wide array of environmental remediation strategies. The use and breeding of vegetation for the in-situ treatment of environmental media (soil, groundwater, sediment) contaminated with organic or inorganic contaminants has shown to provide a low-cost alternative to conventional means of remediating contaminated sites (e.g., groundwater extraction, chemical oxidation or reduction, bioremediation, excavation, etc.). One impediment to effective phytoremediation is the selection of proper plant-species, which is complicated due to the many variables that are required for plant-species viability (i.e. range of soil pH, annual precipitation values, depth to groundwater table, etc.). This study employed the use of a Geographic Information Systems (GIS) to first define the spatial extent of contaminated media (soil and groundwater) at a project site and then support an effective means to optimize phytoremediative techniques to manage these impacts prior to final remediation. Spatial analyses and analytical calculations were coupled to determine an optimal plant species and spacing to maximize the effectiveness of a phytomanagement plan. The incorporation of fuzzy membership functions and fuzzy overlay provide an innovative method to help select the optimal plant-species for phytomanagement planning. Fuzzy membership functions were used to represent the plant growth requirements and provided an intuitive method to represent the uncertainty associated with plant-growth requirements. The fuzzy overlay function then employed a raster-based suitability analysis that together provided decision makers with a scientific solution to optimally design a phytomanagement strategy for site-related volatile organic compound (VOC) impacts. The Niagara Falls Storage Site (NFSS) VOC-impacted groundwater is contained in clayey glacial sediments, which commonly are technically impractical to remediate. Prior on-site studies show that native poplar (cottonwood variants) preferentially translocate or phytoextract the VOCs from the site soils and thus provide a proven mechanism to manage the multi-media impacts. Consequently, the Army Corps of Engineers Buffalo District evaluated phytoremediative approaches as a passive tool to manage the VOCs during the project life cycle prior to final remediation. The fuzzy membership functions and fuzzy overlay modeling of candidate species narrowed the selection to an optimal species and subsequent transpiration modeling estimated the plant spacing for the overall phytomanagement plan. The method employed for this study is easy applied to other phytoremediative and phytomanagement actions derived from hazardous waste decision making. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Distribution Development for Residual Inventory at the New York West Valley Site - 20400

The New York State Energy Research and Development Authority (NYSERDA) is the owner of the Western New York Nuclear Service Center (WNYNSC), a 1,351 ha site located approximately 48 km south of Buffalo, New York. In 1962, Nuclear Fuel Services, Inc. (NFS) entered into Agreements with the Atomic Energy Commission and New York State to construct the first commercial reprocessing plant of nuclear fuel in the United States. NFS, a private company, built and operated the spent fuel reprocessing plant and waste disposal facilities, processing 640 Mg of spent nuclear fuel from 1966 to 1972 under an Atomic Energy Commission license. Nuclear fuel reprocessing operations ended in 1972 and never reopened, leaving behind radioactive and chemical wastes. Operations led to contamination in a number of facilities and locations. Some of that contamination has migrated from waste disposal zones to other layers, formations, and features on and off the WNYNSC. Phase I decommissioning activities are ongoing and involve the removal of a number of areas and structures that have been associated with contamination. The purpose of this work is to outline the approach for characterizing contamination not associated with disposed wastes, contaminated structures, or specific releases. In this work, the term, residual radiological activity, is used to describe environmental contamination that exists subsequent to the completion of Phase I decommissioning activities, that is not associated with disposed wastes, contaminated structures, or specific releases. Contamination from the Site was quantified relative to data that characterize the concentrations of radionuclides that exist in background. Background concentrations are those present in the area but having no influence from Site related activities. The existence of residual radiological activity that is elevated relative to background has the potential to contribute to future risks to human health and the environment. As a consequence, the residual inventory information is used to inform the West Valley Probabilistic Performance Assessment (PPA) model to characterize potential future risks to human health and the environment. The centralized West Valley Data Management System (DMS) was the source of information for the data assembled in this analysis. The DMS is a fairly large compilation consisting of thousands of records from investigation studies, with sample dates ranging from 1990 to present. Samples from monitoring wells, boreholes, geoprobe studies, surface water, surface soils, storm water outfalls, ventilation stack filters, plant and animal tissues, and more are included in the DMS. Results are typically reported in units of activity per unit volume. For the purpose of the analyses presented here, all results were converted into consistent units of pCi per unit volume. Since 1990, data have been collected from various locations across the WNYNSC at different times with varying frequency over the course of several decades. As a consequence, a number of potential issues can arise with respect to the assembly of a dataset that is deemed adequate for the characterization of residual radiological activity. These issues were assessed and resolved to the extent possible through careful consideration of the properties of the distributions. The intent was to use data which characterize the current state of the Site. Radionuclides can be designated to one of several groups depending on their origin. In this work the groups considered were 1) Naturally Occurring Radioactive Material (NORM), 2) fallout, and 3) Other (including power plant, medical research, etc). This grouping is a useful construct with respect to the interpretation of fixed laboratory results. For example, NORM radionuclides that exist within a decay chain should have approximately equivalent distributions of concentrations if they are representative of background conditions. Insights such as these can be used as a check to identify sample results that need to be further investigated or omitted due to issues associated with reported results from fixed laboratory analyses. This type of analysis provided a foundation for the assessment of the adequacy of sample results for use in subsequent components of an assessment. The general process for the assessment of residual radiological contamination at the Site consists of a sequence of several steps. First, for each analyte, several statistical tests were performed to assess the weight of evidence against the null hypothesis that the mean of the distribution of concentrations was equal to zero. If the mean of the distribution of concentrations for a given radionuclide was not found to be greater than zero, then it was removed from consideration as a component of the residual radiological contamination. If there was significant evidence to reject the hypothesis of the mean being equal to zero, the second step was to compare the distribution of the data from the Site to that of the corresponding background. A suite of tests was used to compare the distributions of the site and background data. The results of these tests were collectively used to determine if site data are elevated relative to background. The third step was to develop distributions using a Bayesian framework to characterize the distribution of mean of the increment present above background for each of the radionuclides. The Bayesian model implemented allowed for the comparison of site-specific records to background concentrations to better approximate contamination attributed to the Site. A final screening step was employed for radionuclides that exceed background. This screening step compared 95% upper confidence limits (UCLs) from the increment distribution developed in the previous step to the risk screening levels. This approach yields a list of analytes that were determined to be elevated relative to background.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quantifying the impact of climate change on erosion - 20397

The New York State Energy Research and Development Authority (NYSERDA) is the owner of the Western New York Nuclear Service Center (WNYNSC), a 1,351-ha (3,338-ac) site located approximately 48 km (30 mi) south of Buffalo, New York. In 1962, Nuclear Fuel Services, Inc. (NFS) entered into Agreements with the Atomic Energy Commission and New York State to construct the first commercial reprocessing plant of nuclear fuel in the United States. NFS, a private company, built and operated the spent fuel reprocessing plant and waste disposal facilities, processing 640 Mg (metric tons, or 705 short tons) of spent nuclear fuel from 1966 to 1972 under an Atomic Energy Commission license. Nuclear fuel reprocessing operations ended in 1972 and never reopened, leaving behind radioactive and chemical wastes. Erosion can play an important role in the fate and transport of waste at sites where disposal of long-lived waste is anticipated. The statistical characterization of key processes related to erosion is essential to the understanding of site stability through time. One of the key processes governing erosion is extreme precipitation and it is critical that trends in the distribution of extreme precipitation events through time be represented. The evidence of climate change is increasingly well documented and projected impacts on extreme precipitation events should be incorporated in performance assessment studies when relevant. Not evaluating future climate states in a performance assessment is contradictory to good modeling practice. Specifically, excluding climate change limits development of modeling information that could aid in effective decision making. The current climate literature provides both observational evidence and climate model projections of climate trends and/or climate change in the late 20. and early 21. centuries for North America and the northeast United States. In this work, this information was used to assess the impacts of potential changes in climate on erosion processes. The goal was to understand how projections of future climate relate to the performance of the WNYNSC through time. In the first stage of this work multi-temporal historical aerial images were analyzed in conjunction with orthophotography and Lidar data to develop probability distributions for variables representing important erosion processes. The information from these analyses was then used in conjunction with simulated data from the West Valley Erosion Working Group (EWG). Analysis of EWG simulations provides estimates for the change in erosion rates through time that is driven by changes in climate. The time-varying rates of erosion change were applied to the historical aerial imagery data in order to inform time-varying rates of erosion that are driven by changes in climate. Ultimately, this process resulted in the identification of locations for features like gully heads using both the Lidar dataset and projection of the estimated location from the historical aerial photo under consideration back to the Lidar dataset. The distance between the estimate of the location from the historical image and that of the Lidar dataset was the estimated distance the feature has moved. This distance was then divided by the number of years between the Lidar dataset and the year of the historical aerial image of interest to get a rate of movement through time. This was done for several dozen points on each historical aerial image. The analyses from the EWG were used to characterize the relative impact of climate change on the erosion rates. This relative impact was quantified by comparing the LEM based estimates of erosion that were derived using historical climate data with LEM based estimates of erosion that were derived using projections of future climate. The relative increase in the erosion rates was then applied to the historical estimates of erosion derived from the analysis of the historical aerial imagery. This approach was used since the LEM-based estimated of the historical erosion rates from the past century have a bias towards underestimating erosion. This underestimation is hypothesized to be a consequence of an inability of the LEMs to account for the impacts of land-use change (i.e. deforestation) which had been shown to significantly increase erosion in similar Northern hardwood forest ecosystems. In summary, gully head retreat rate and gully widening rate were characterized using statistical probability distributions from the historical aerial image analysis. Simulated data from the EWG was used to estimate the climatically-driven changes in erosion rates through time. The changes through time from the EWG were applied to the gully head retreat rate and gully widening rate characterized using the historical aerial image analysis. This information can be used to inform PPA models to project future risks from a given site. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Updates to a Preliminary Probabilistic Performance Assessment Model for Radiological and Chemical Contamination at the West Valley Site, New York - 20420

The New York State Energy Research and Development Authority (NYSERDA) is the owner of the Western New York Nuclear Service Center (WNYNSC), a 1,351-ha site located approximately 48 km south of Buffalo, New York. In 1962, Nuclear Fuel Services, Inc. (NFS) entered into agreements with the Atomic Energy Commission and New York State to construct the first commercial reprocessing plant of nuclear fuel in the United States at the WNYNSC. NFS built and operated the spent fuel reprocessing plant and waste disposal facilities, processing 640 Mg (640 metric tons) of spent nuclear fuel from 1966 to 1972 under an Atomic Energy Commission license. Nuclear fuel reprocessing operations halted in 1972 and never restarted, leaving behind radioactive and chemical wastes. The U.S. Department of Energy (DOE) was required to complete certain waste management activities under the West Valley Demonstration Project (WVDP) Act of 1980 including decommissioning of WVDP facilities. As collaborating agencies, NYSERDA and the DOE are tasked with making decisions about decommissioning and risk reduction for the West Valley Site. Neptune and Company, Inc. (Neptune) was contracted to develop a probabilistic performance assessment (PPA) model to assist the agencies in their decision making process for decommissioning the WVDP and WNYNSC. One important tool that is needed in order to inform the decision-making process is a science-based model of the West Valley Site that evaluates potential future consequences for human health and the environment. This forms the core of the spatial domain of the West Valley PPA Model. The PPA Model, developed using the GoldSim system modeling software, is a tool intended to provide support for decision making that evaluates uncertainty, in a manner that is transparent, defensible, and robust. The PPA Model includes contaminant transport and health effects components, and is organized around geographically-grouped contaminated facilities. These include the waste disposal areas licensed by the U.S. Nuclear Regulatory Commission and the State of New York, a waste tank farm for storage of high level radioactive waste resulting from reprocessing operations, and several areas contaminated with radioactive and chemical constituents. The PPA Model evaluates contaminant transport from these sources to points of exposure across the site and into receiving surface waters and sediments. Hypothetical people and wildlife could be exposed to contamination at these locations, and the effects of these exposures are evaluated. Contaminant transport processes to be evaluated in the PPA Model include groundwater and surface water transport, contaminant translocation by plants and animals, diffusion, and erosion. The evaluation of exposures to people in this preliminary model is limited to a resident farmer scenario, and ecological assessment is performed at the level of a screening analysis. The results of these preliminary evaluations inform future model developments. PPA Model results are subjected to sensitivity analysis in order to determine those pathways and parameters that are most significant in influencing the results. This information allows analysts and decision makers to focus on those aspects of Site behavior and processes. With this information, the decision makers can drive informed, defensible decisions regarding decommissioning of the Site. This paper includes an update of the information presented at WM2019 [1]. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Dose Assessment Model for Radioactive Waste Exposed by Gully Erosion at West Valley - 20513

The Western New York Nuclear Service Center (WNYNSC), located approximately 48 km south of Buffalo, New York, is the site of a former nuclear fuel reprocessing and radioactive waste disposal facility. Spent nuclear fuel was processed there from 1966 to 1972, leaving behind radioactive and chemical wastes in two disposal areas and a waste tank farm. Site operations also resulted in releases of radioactivity to site soils, groundwater, and to surface waters draining the site. The New York State Energy Research and Development Authority (NYSERDA) and the U.S. Department of Energy (DOE) are collaborating in a process of decision making for decommissioning those facilities remaining at the WNYNSC following the completion of Phase 1 decommissioning. Neptune and Company, Inc. (Neptune) was contracted to develop a probabilistic performance assessment (PPA) computer model to assist the agencies in this process. The PPA Model includes a contaminant transport component focusing on the movement of contaminants within and among environmental media including groundwater and surface water transport, contaminant translocation by plants and animals, diffusion, and erosion. The model also includes evaluation of potential exposure and health effects for a Resident Farmer exposure scenario, where the Resident Farmer represents a critical group, described as that group of individuals reasonably expected to receive the greatest exposure to residual radioactivity for any applicable set of circumstances. The West Valley Site is located in the glaciated Allegheny Plateau region of western New York State. The waste reprocessing and disposal areas were constructed on a relatively fat area of plateau dissected by drainages of Buttermilk Creek, including Erdman Brook, Franks Creek, and Quarry Creek. An important aspect of the contaminant transport component of the PPA model is consideration of erosive processes such as slumping of the stream slopes and the advance of gullies from these streams. These erosion processes remove material from the plateau, growing the size of the creek valleys and making them wider and deeper. Of particular interest for the impact of erosion is radioactive waste contained in the Nuclear Regulatory Commission (NRC)-Licensed Disposal Area (NDA), the New York State-Licensed Disposal Area (SDA), and residual radiological inventory in the underground storage tanks at the Waste Tank Farm (WTF). The PPA Model is organized around geographically-defined facilities which were constructed upon the plateau, including the NDA, SDA, and WTF. Ongoing stream erosion processes will potentially transfer radioactive waste and residual inventory from these facilities to the ground surface on adjacent hillslope areas where erosion has breached the facility. Hence, it is important to evaluate the consequences of potential exposures to a Resident Farmer on the hillslopes below a breached facility. Two interrelated aspects of the dose assessment model related to hillslope exposure are discussed: 1) representation of the physical processes related to transport of radionuclides from facilities onto the hillslopes, and from the hillslopes into adjoining creeks where contaminated material migrates downstream with surface water and sediment, and; 2) adaptation of the activities associated with the Resident Farmer scenario to assess potential exposures to contamination in the hillslope areas. This discussion will cover the conceptual basis of the hillslope exposure and transport models, and also implementation in the PPA computer model. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗