Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Bone imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Dose- and Ion-Dependent Effects in the Oxidative Stress Response to Space-Like Radiation Exposure in the Skeletal System

Exposure to space radiation may pose a risk to skeletal health during subsequent aging. Irradiation acutely stimulates bone remodeling in mice, although the long-term influence of space radiation on bone-forming potential (osteoblastogenesis) and possible adaptive mechanisms are not well understood. We hypothesized exposure to ionizing radiation impairs osteoblastogenesis in an ion-type specific manner, with low doses capable of modulating expression of redox-related genes. 16-week old, male, C57BL6/J mice were exposed to low linear-energy-transfer (LET) protons (150 mega electron volts per nucleon) or high-LET (sup 56) Fe ions (600 mega electron volts per nucleon) using either low (5 or 10 centigrays) or high (50 or 200 centigrays) doses at NASAs Space Radiation Lab at Brookhaven National Lab (NSRL/BNL). Tissues were harvested 5 weeks or 1 year after irradiation and bones were analyzed by microcomputed tomography for cancellous microarchitecture and cortical geometry. Marrow-derived, adherent cells were grown under osteoblastogenic culture conditions. Cell lysates were analyzed for select groups by RT-PCR (Reverse Transcription-Polymerase Chain Reaction) during the proliferative phase or the mineralizing phase, and differentiation was analyzed by imaging mineralized nodules (percentage surface area). Representative genes were selected for expression analyses, including cell proliferation (PCNA, Cdk2, p21, p53), differentiation (Runx2, Alpl, Bglap), oxidative metabolism (Catalase, GPX, MnSOD, CuZnSOD, iNos, Foxo1), DNA-damage repair (Gadd45), or apoptosis (Caspase 3). As expected, a high dose (200 centigrays), but not low doses, of either (sup 56) Fe or protons caused a loss of cancellous bone volume per total volume. Marrow cells produced mineralized nodules ex vivo regardless of radiation type or dose; (sup 56) Fe (200 centigrays) inhibited median nodule area by more than 90 percent at 5 weeks and 1 year post-irradiation, compared to controls. At 5 weeks post exposure, irradiation with protons or (sup 56) Fe caused few changes in gene expression levels during osteoblastogenesis, although a high dose of (sup 56) Fe (200 centigrays) increased levels of Catalase and Gadd45. In addition, supplementing cell culture media with SOD protected marrow-derived osteoprogenitors from the damaging effects of exposure to low-LET ((sup 137) Cs gamma) if irradiated in vitro, but had limited protective effects on high-LET (sup 56) Fe-exposed cells. In sum, exposure of mice to either protons or (sup 56) Fe at a relatively high dose (200 cGy) caused persistent bone loss, whereas only high-LET (sup 56) Fe increased expression of redox-related genes and inhibited osteoblastogenesis, albeit to a limited extent. We conclude that high-LET irradiation impaired osteoblastogenesis and regulated steady-state gene expression of select redox-related genes during osteoblastogenesis, which may contribute to persistent bone loss.

ionizing radiation↗

An overview of vertebrate mineralization with emphasis on collagen-mineral interaction

The nucleation, growth, and development of mineral crystals through their interaction principally with collagen in normal bone and calcifying tendon have been elaborated by applying a number of different techniques for analysis of the inorganic and organic constituents of these tissues. The methods have included conventional and high voltage electron microscopy, electron diffraction, microscopic tomography and 3D image reconstruction, and atomic force microscopy. This summary presents results of these studies that have now characterized the size, shape, and aspects of the chemical nature of the crystals as well as their orientation, alignment, location, and distribution with respect to collagen. These data have provided the means for understanding more completely the formation and strength of the collagen-mineral composite present in most vertebrate calcifying tissues and, from that information, a basis for the adaptation of such tissues under mechanical constraints. In the context of the latter point, other data are given showing effects on collagen in bone cell cultures subjected to the unloading parameters of spaceflight. Implications of these results may be particularly relevant to explaining loss of bone by humans and other vertebrate animals during missions in space, during situations of extended fracture healing, long-term bedrest, physical immobilization, and related conditions. In a broader sense, the data speak to the response of bone and mineralized vertebrate tissues to changes in gravitational loading and applied mechanical forces in general.

Non-NASA Center↗

Combined thermographic phosphor and digital image correlation (TP + DIC) for simultaneous temperature and strain measurements

We report thermographic phosphors (TP) are combined with stereo digital image correlation (DIC) in a novel diagnostic, TP + DIC, to measure full-field surface strains and temperatures simultaneously. The TP + DIC method is presented, including corrections for nonlinear CMOS camera detectors and generation of pixel-wise calibration curves to relate the known temperature to the ratio of pixel intensities between two distinct wavelength bands. Additionally, DIC is employed not only for strain measurements but also for accurate image registration between the two cameras for the two-colour ratio method approach of phosphoric thermography. TP + DIC is applied to characterize the thermo-mechanical response of 304L stainless steel dog bones during tensile testing at different strain rates. The dog bones are patterned for DIC with Mg 3 F 2 GeO 4 :Mn (MFG) via aerosol deposition through a shadow mask. Temperatures up to 425°K (150°C) and strains up to 1.0 mm/mm are measured in the localized necking region, with conservative noise levels of 10°K and 0.01 mm/mm or less. Finally, TP + DIC is compared to the more established method of combining infrared (IR) thermography with DIC (IR + DIC), with results agreeing favourably. Three topics of continued research are identified, including cracking of the aerosol-deposited phosphor DIC features, incomplete illumination for pixels on the border of the phosphor features, and phosphor emission evolution as a function of applied substrate strain. This work demonstrates the combination of phosphor thermography and DIC and lays the foundation for further development of TP + DIC for testing in combined thermo-mechancial environments.

304L stainless steel↗

Late Effects of Heavy-Ion Irradiation on Ex Vivo Osteoblastogenesis and Cancellous Bone Microarchitecture

Prolonged spaceflight causes degeneration of skeletal tissue with incomplete recovery even after return to Earth. We hypothesize that heavy-ion irradiation, a component of Galactic Cosmic Radiation, damages osteoblast progenitors and may contribute to bone loss during long duration space travel beyond the protection of the Earth's magnetosphere. Male, 16 week-old C57BL6/J mice were exposed to high-LET (56-Fe, 600MeV) radiation using either low (5 or 10cGy) or high (50 or 200cGy) doses at the NASA Space Radiation Lab and were euthanized 3-4, 7, or 35 days later. Bone structure was quantified by microcomputed tomography (6.8 μm pixel size) and marrow cell redox assessed using membrane permeable, free radical-sensitive fluorogenic dyes. To assess osteoblastogenesis, adherent marrow cells were cultured ex vivo, then mineralized nodule formation quantified by imaging and gene expression analyzed by RT-PCR. Interestingly, 3-4 days post-exposure, fluorogenic dyes that reflect cytoplasmic generation of reactive nitrogen/oxygen species (DAF-FM Diacetate or CM-H2DCFDA) revealed irradiation (50cGy) reduced free radical generation (20-45%) compared to sham-irradiated controls. Alternatively, use of a dye showing relative specificity for mitochondrial superoxide generation (MitoSOX) revealed an 88% increase compared to controls. One week after exposure, reactive oxygen/nitrogen levels remained lower (24%) relative to sham-irradiated controls. After one month, high dose irradiation (200 cGy) caused an 86% decrement in ex vivo nodule formation and a 16-31% decrement in bone volume to total volume and trabecular number (50, 200cGy) compared to controls. High dose irradiation (200cGy) up-regulated expression of a late osteoblast marker (BGLAP) and select genes related to oxidative metabolism (Catalase) and DNA damage repair (Gadd45). In contrast, lower doses (5, 10cGy) did not affect bone structure or ex vivo nodule formation, but did down-regulate iNOS by 0.54-0.58 fold. Thus, both low- and high-doses of heavy-ion irradiation cause time-dependent, adaptive changes in redox state within marrow cells but only high doses (50, 200cGy) inhibit osteoblastogenesis and cause cancellous bone loss. We conclude space radiation has the potential to cause persistent damage to bone marrow-derived stem and progenitor cells for osteoblasts despite adaptive changes in cellular redox state.

LATE EFFECTS OF HEAVY-ION IRRADIATION↗

Mechanisms of Bone Mineralization and Effects of Mechanical Loading

The data suggest that PTH and PKC inhibit nodule formation, and that alternative energy sources are utilized by osteoblasts in the process of mineralization. The conditions and techniques to grow, fix, photograph, and measure bone mineralization in vitro were defined. The results are presently in preliminary form and require further assessment as follows; quantitate the surface area of nodules + treatments via computer-aided image analysis; use PTH + inhibitors of signaling pathways to determine the mechanism of nodule formation; determine how protein kinase C is involved as a promotor of nodule formation; cell proliferation vs. cell death affected by modulation of signal transduction (i.e., PTH, enzyme inhibitors and activators); identify mRNA induced or decreased in response to PTH and signaling modulators that encode proteins that regulate cell morphology, proliferation, and nodule formation. Therefore, several follow-up studies between the laboratories at NASA-Ames Research Center and my laboratory at the University of Illinois have been initiated.

Babich, Michael↗

NASA Tech Briefs, December 2012

The topics include: Pattern Generator for Bench Test of Digital Boards; 670-GHz Down- and Up-Converting HEMT-Based Mixers; Lidar Electro-Optic Beam Switch with a Liquid Crystal Variable Retarder; Feedback Augmented Sub-Ranging (FASR) Quantizer; Real-Time Distributed Embedded Oscillator Operating Frequency Monitoring; Software Modules for the Proximity-1 Space Link Interleaved Time Synchronization (PITS) Protocol; Description and User Instructions for the Quaternion to Orbit v3 Software; AdapChem; Mars Relay Lander and Orbiter Overflight Profile Estimation; Extended Testability Analysis Tool; Interactive 3D Mars Visualization; Rapid Diagnostics of Onboard Sequences; MER Telemetry Processor; pyam: Python Implementation of YaM; Process for Patterning Indium for Bump Bonding; Archway for Radiation and Micrometeorite Occurrence Resistance; 4D Light Field Imaging System Using Programmable Aperture; Device and Container for Reheating and Sterilization; Radio Frequency Plasma Discharge Lamps for Use as Stable Calibration Light Sources; Membrane Shell Reflector Segment Antenna; High-Speed Transport of Fluid Drops and Solid Particles via Surface Acoustic Waves; Compact Autonomous Hemispheric Vision System; A Distributive, Non-Destructive, Real-Time Approach to Snowpack Monitoring; Wideband Single-Crystal Transducer for Bone Characterization; Numerical Simulation of Rocket Exhaust Interaction With Lunar Soil; Motion Imagery and Robotics Application (MIRA): Standards-Based Robotics; Particle Filtering for Model-Based Anomaly Detection in Sensor Networks; Ka-band Digitally Beamformed Airborne Radar Using SweepSAR Technique; Composite With In Situ Plenums; Multi-Beam Approach for Accelerating Alignment and Calibration of HyspIRI-Like Imaging Spectrometers; JWST Lifting System; Next-Generation Tumbleweed Rover; Pneumatic System for Concentration of Micrometer-Size Lunar Soil.

Source record↗

Lasofoxifene as a potential treatment for therapy-resistant ER-positive metastatic breast cancer

Background: Endocrine therapy remains the mainstay of treatment for estrogen receptor-positive (ER+) breast cancer. Constitutively active mutations in the ligand binding domain of ERα render tumors resistant to endocrine agents. Breast cancers with the two most common ERα mutations, Y537S and D538G, have low sensitivity to fulvestrant inhibition, a typical second-line endocrine therapy. Lasofoxifene is a selective estrogen receptor modulator with benefits on bone health and breast cancer prevention potential. This study investigated the anti-tumor activity of lasofoxifene in breast cancer xenografts expressing Y537S and D538G ERα mutants. The combination of lasofoxifene with palbociclib, a CDK4/6 inhibitor, was also evaluated. Methods: Luciferase-GFP tagged MCF7 cells bearing wild-type, Y537S, or D538G ERα were injected into the mammary ducts of NSG mice (MIND model), which were subsequently treated with lasofoxifene or fulvestrant as single agents or in combination with palbociclib. Tumor growth and metastasis were monitored with in vivo and ex vivo luminescence imaging, terminal tumor weight measurements, and histological analysis. Results: As a monotherapy, lasofoxifene was more effective than fulvestrant at inhibiting primary tumor growth and reducing metastases. Adding palbociclib improved the effectiveness of both lasofoxifene and fulvestrant for tumor suppression and metastasis prevention at four distal sites (lung, liver, bone, and brain), with the combination of lasofoxifene/palbociclib being generally more potent than that of fulvestrant/palbociclib. X-ray crystallography of the ERα ligand binding domain (LBD) shows that lasofoxifene stabilizes an antagonist conformation of both wild-type and Y537S LBD. The ability of lasofoxifene to promote an antagonist conformation of Y537S, combined with its long half-life and bioavailability, likely contributes to the observed potent inhibition of primary tumor growth and metastasis of MCF7 Y537S cells. Conclusions: We report for the first time the anti-tumor activity of lasofoxifene in mouse models of endocrine therapy-resistant breast cancer. The results demonstrate the potential of using lasofoxifene as an effective therapy for women with advanced or metastatic ER+ breast cancers expressing the most common constitutively active ERα mutations.

60 APPLIED LIFE SCIENCES↗

Miniature X-Ray Bone Densitometer

The purpose of the Dual Energy X-ray Absorptiometry (DEXA) project is to design, build, and test an advanced X-ray absorptiometry scanner capable of being used to monitor the deleterious effects of weightlessness on the human musculoskeletal system during prolonged spaceflight. The instrument is based on the principles of dual energy x-ray absorptiometry and is designed not only to measure bone, muscle, and fat masses but also to generate structural information about these tissues so that the effects on mechanical integrity may be assessed using biomechanical principles. A skeletal strength assessment could be particularly important for an astronaut embarking on a remote planet where the consequences of a fragility fracture may be catastrophic. The scanner will employ multiple projection images about the long axis of the scanned subject to provide geometric properties in three dimensions, suitable for a three-dimensional structural analysis of the scanned region. The instrument will employ advanced fabrication techniques to minimize volume and mass (100 kg current target with a long-term goal of 60 kg) of the scanner as appropriate for the space environment, while maintaining the required mechanical stability for high precision measurement. The unit will have the precision required to detect changes in bone mass and geometry as small as 1% and changes in muscle mass as small as 5%. As the system evolves, advanced electronic fabrication technologies such as chip-on-board and multichip modules will be combined with commercial (off-the-shelf) parts to produce a reliable, integrated system which not only minimizes size and weight, but, because of its simplicity, is also cost effective to build and maintain. Additionally, the system is being designed to minimize power consumption. Methods of heat dissipation and mechanical stowage (for the unit when not in use) are being optimized for the space environment.

Charles, Harry K., Jr.↗

Method and Apparatus for Virtual Interactive Medical Imaging by Multiple Remotely-Located Users

A virtual interactive imaging system allows the displaying of high-resolution, three-dimensional images of medical data to a user and allows the user to manipulate the images, including rotation of images in any of various axes. The system includes a mesh component that generates a mesh to represent a surface of an anatomical object, based on a set of data of the object, such as from a CT or MRI scan or the like. The mesh is generated so as to avoid tears, or holes, in the mesh, providing very high-quality representations of topographical features of the object, particularly at high- resolution. The system further includes a virtual surgical cutting tool that enables the user to simulate the removal of a piece or layer of a displayed object, such as a piece of skin or bone, view the interior of the object, manipulate the removed piece, and reattach the removed piece if desired. The system further includes a virtual collaborative clinic component, which allows the users of multiple, remotely-located computer systems to collaboratively and simultaneously view and manipulate the high-resolution, three-dimensional images of the object in real-time.

Ross, Muriel D.↗

Comparative Uptake Patterns of Radioactive Iodine and [18F]-Fluorodeoxyglucose (FDG) in Metastatic Differentiated Thyroid Cancers

Background: Metastatic differentiated thyroid cancer (DTC) represents a molecularly heterogeneous group of cancers with varying radioactive iodine (RAI) and [ 18 F]-fluorodeoxyglucose (FDG) uptake patterns potentially correlated with the degree of de-differentiation through the so-called “flip-flop” phenomenon. However, it is unknown if RAI and FDG uptake patterns correlate with molecular status or metastatic site. Materials and Methods: A retrospective analysis of metastatic DTC patients (n = 46) with radioactive 131-iodine whole body scan (WBS) and FDG-PET imaging between 2008 and 2022 was performed. The inclusion criteria included accessible FDG-PET and WBS studies within 1 year of each other. Studies were interpreted by two blinded radiologists for iodine or FDG uptake in extrathyroidal sites including lungs, lymph nodes, and bone. Cases were stratified by BRAF V600E mutation status, histology, and a combination of tumor genotype and histology. The data were analyzed by McNemar’s Chi-square test. Results: Lung metastasis FDG uptake was significantly more common than iodine uptake (WBS: 52%, FDG: 84%, p = 0.04), but no significant differences were found for lymph or bone metastases. Lung metastasis FDG uptake was significantly more prevalent in the papillary pattern sub-cohort (WBS: 37%, FDG: 89%, p = 0.02) than the follicular pattern sub-cohort (WBS: 75%, FDG: 75%, p = 1.00). Similarly, BRAF V600E+ tumors with lung metastases also demonstrated a preponderance of FDG uptake (WBS: 29%, FDG: 93%, p = 0.02) than BRAF V600E- tumors (WBS: 83%, FDG: 83%, p = 1.00) with lung metastases. Papillary histology featured higher FDG uptake in lung metastasis (WBS: 39%, FDG: 89%, p = 0.03) compared with follicular histology (WBS: 69%, FDG: 77%, p = 1.00). Patients with papillary pattern disease, BRAF V600E+ mutation, or papillary histology had reduced agreement between both modalities in uptake at all metastatic sites compared with those with follicular pattern disease, BRAF V600E- mutation, or follicular histology. Low agreement in lymph node uptake was observed in all patients irrespective of molecular status or histology. Conclusions: The pattern of FDG-PET and radioiodine uptake is dependent on molecular status and metastatic site, with those with papillary histology or BRAF V600E+ mutation featuring increased FDG uptake in distant metastasis. Further study with an expanded cohort may identify which patients may benefit from specific imaging modalities to recognize and surveil metastases.

60 APPLIED LIFE SCIENCES↗

Estimating the Risk of Renal Stone Events During Long-Duration Spaceflight

Introduction: Given the bone loss and increased urinary calcium excretion in the microgravity environment, persons participating in long-duration spaceflight may have an increased risk for renal stone formation. Renal stones are often an incidental finding of abdominal imaging studies done for other reasons. Thus, some crewmembers may have undiscovered, asymptomatic stones prior to their mission. Methods: An extensive literature search was conducted concerning the natural history of asymptomatic renal stones. For comparison, simulations were done using the Integrated Medical Model (IMM). The IMM is an evidence-based decision support tool that provides risk analysis and has the capability to optimize medical systems for missions by minimizing the occurrence of adverse mission outcomes such as evacuation and loss of crew life within specified mass and volume constraints. Results: The literature of the natural history of asymptomatic renal stones in the general medical population shows that the probability of symptomatic event is 8% to 34% at 1 to 3 years for stones < 7 mm. Extrapolated to a 6-month mission, for stones < 5 to 7 mm, the risk for any stone event is about 4 to 6%, with a 0.7% to 4% risk for intervention, respectively. IMM simulations compare favorably with risk estimates garnered from the terrestrial literature. The IMM forecasts that symptomatic renal stones may be one of the top drivers for medical evacuation of an International Space Station (ISS) mission. Discussion: Although the likelihood of a stone event is low, the consequences could be severe due to limitations of current ISS medical capabilities. Therefore, these risks need to be quantified to aid planning, limit crew morbidity and mitigate mission impacts. This will be especially critical for missions beyond earth orbit, where evacuation may not be an option.

Reyes, David↗

Estimating the Risk of Renal Stone Events during Long-Duration Spaceflight

Introduction: Given the bone loss and increased urinary calcium excretion in the microgravity environment, persons participating in long-duration spaceflight may have an increased risk for renal stone formation. Renal stones are often an incidental finding of abdominal imaging studies done for other reasons. Thus, some crewmembers may have undiscovered, asymptomatic stones prior to their mission. Methods: An extensive literature search was conducted concerning the natural history of asymptomatic renal stones. For comparison, simulations were done using the Integrated Medical Model (IMM). The IMM is an evidence-based decision support tool that provides risk analysis and has the capability to optimize medical systems for missions by minimizing the occurrence of adverse mission outcomes such as evacuation and loss of crew life within specified mass and volume constraints. Results: The literature of the natural history of asymptomatic renal stones in the general medical population shows that the probability of symptomatic event is 8% to 34% at 1 to 3 years for stones < 7 mm. Extrapolated to a 6-month mission, for stones < 5 to 7 mm, the risk for any stone event is about 4 to 6%, with a 0.7% to 4% risk for intervention, respectively. IMM simulations compare favorably with risk estimates garnered from the terrestrial literature. The IMM forecasts that symptomatic renal stones may be one of the top drivers for medical evacuation of an International Space Station (ISS) mission. Discussion: Although the likelihood of a stone event is low, the consequences could be severe due to limitations of current ISS medical capabilities. Therefore, these risks need to be quantified to aid planning, limit crew morbidity and mitigate mission impacts. This will be especially critical for missions beyond earth orbit, where evacuation may not be an option.

Reyes, David↗

Ultimate FY23 Vacuum Creep Testing Facility Operation Report

This facility operation report covers the refurbishment and initial testing of a vacuum creep frame used to conduct 1300°C tensile and creep tests on Mo- and Nb-based alloys. The report details the refurbishment of the frame and initial operation including 100 h creep experiments compared to similar tests in argon. Unlike the 25 mm dogbone specimens tested in argon, the vacuum load train requires 76 mm dog bone specimens. Testing in vacuum has eliminated concern of O embrittlement in argon and Nb alloy CB103 showed >120% tensile elongation at 1300°C and 1450°C. Also, a window in the vacuum chamber allows the use of digital image correlation (DIC) to measure strain rather than the load train displacement used in the argon frames. Comparison of the displacement and DIC results in the vacuum frame showed significant variation in primary creep deformation, likely due to the machine compliance, but similar secondary creep rates. Recently, ULTIMATE teams have submitted specimens for testing in vacuum. With the relatively low volume of creep testing, the facility performance metric of testing within 4 weeks of receiving specimens has been met.

36 MATERIALS SCIENCE↗

Effect of a growth hormone treatment on bone orthotropic elasticity in dwarf rats

A refinement of the current ultrasonic elasticity technique was used to measure the orthotropic elastic properties of rat cortical bone as well as to quantify changes in elastic properties, density, and porosity of the dwarf rat cortex after a treatment with recombinant human growth hormone (rhGH). The ultrasonic elasticity technique was refined via optimized signal management of high-frequency wave propagation through cubic cortical specimens. Twenty dwarf rats (37 days old) were randomly assigned to two groups (10 rats each). The dwarf rat model (5-10% of normal GH) was given subcutaneous injections of either rhGH or saline over a 14-day treatment period. Density was measured using Archimedes technique. Porosity and other microstructural characteristics were also explored via scanning electron microscopy and image analysis. Statistical tests verified significant decreases in cortical orthotropic Young's (-26.7%) and shear (-16.7%) moduli and density (-2.42%) concomitant with an increase in porosity (+125%) after rhGH treatments to the dwarf model (p < 0.05). A change in material symmetry from orthotropy toward planar isotropy within the radial-circumferential plane after GH treatments was also noted. These results demonstrate some alteration in bone properties at this time interval. Structural implications of these changes throughout physiological loading regimens should be explored.

NASA Discipline Musculoskeletal↗

Iodine imaging using spectral analysis

Existing radiographic imaging systems provide images which represent an integration or averaging over the energy spectrum. In order to provide noninvasive angiography it is necessary to image the relatively small amounts of iodine which are available following an intravenous administration. This is accomplished by making use of the special spectral characteristics of iodine. Two methods will be presented. One involves a special grating for encoding the iodine information in the form of a fine line pattern. This is subsequently decoded to provide images of iodinated structures which are otherwise almost invisible. The second method utilizes a scanned X-ray beam which is rapidly switched in the high energy region. In this region, iodine experiences significant variations in the attenuation coefficient while bone and soft tissue do not. An efficient and accurate X-ray detector can be used with scanned X-ray beams. This provides a high degree of sensitivity enabling the visualization of small vessels containing relatively dilute iodine.

Macovski, A.↗

Spacelab mission 2: Experimental descriptions

The second Spacelab Mission and the 12 multidisciplinary experiments selected to fly on board are described. These experiments include the following: vitamin D metabolities and bone demineralization; interaction of oxygen and gravity influenced lignification; ejectable plasma diagnostics package; plasma depletion experiments for ionospheric and radio astronomical studies; small helium cooled IR telescope; elemental composition and energy spectra of cosmic ray nuclei; hard X-ray imaging of clusters of galaxies and other extended X-ray sources; solar magnetic and velocity field measurement system; solar coronal helium abundance Spacelab experiment; solar UV high resolution telescope and spectroraph; solar UV spectral irradiance monitor; and properties of superfluid helium in zero-G.

Clifton, K. S.↗