Adaptation to hypothermia.
Ability of hypothermia-adapted rats to learn and perform at low body temperature
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Ability of hypothermia-adapted rats to learn and perform at low body temperature
Chronic exposure to increased force environments (+G) has pronounced effects on the circadian and homeostatic regulation of body temperature (T(b)), ambulatory activity (Act), heart rate, feeding, and adiposity. By using the Brn 3.1 knockout mouse, which lacks vestibular hair cells, we recently described a major role of the vestibular system in mediating some of these adaptive responses. The present study used the C57BL6JEi-het mouse strain (het), which lacks macular otoconia, to elucidate the contribution of specific vestibular receptors. In this study, eight het and eight WT mice were exposed to 2G for 8 weeks by means of chronic centrifugation. In addition, eight het and eight WT mice were maintained as 1G controls in similar conditions. Upon 2G exposure, the WT exhibited a decrease in T(b) and an attenuated T(b) circadian rhythm. Act means and rhythms also were attenuated. Body mass and food intake were significantly lower than the 1G controls. After 8 weeks, percent body fat was significantly lower in the WT mice (P < 0.0001). In contrast, the het mice did not exhibit a decrease in mean T(b) and only a slight decrease in T(b) circadian amplitude. het Act levels were attenuated similarly to the WT mice. Body mass and food intake were only slightly attenuated in the het mice, and percent body fat, after 8 weeks, was not different in the 2G het group. These results link the vestibular macular receptors with specific alterations in homeostatic and circadian regulation.
Pill-sized transmitter measures deep body temperature in studies of circadian rhythm and indicates general health. Ingestible device is a compromise between accuracy, circuit complexity, size and transmission range.
Equivalent black body temperatures of clouds around tropical cyclones are used in a statistical technique to forecast changes in maximum winds for 24 hours in advance.
Daily physiological rhythm changes associated with light intensity and color, noting body temperature oscillations vs light intensity, heart rate changes, etc
Hamsters responses to helium-oxygen and nitrogen- oxygen at ambient temperatures, comparing respiration rates, weights and body temperatures
Observations of Comets Kohoutek (1973f), Bradfield (1974b), and P/Encke have been made at a number of wavelengths between 0.55 and 18 microns. The silicate feature first observed in Comet Bennett (1969i) seems to be a common characteristic of cometary material. The comas of these comets radiate infrared with an effective temperature higher than the black-body temperature at the given distance from the sun. The albedo of the dust particles is between 0.10 and 0.20. The particles in the coma and tail are small, but the particles in the anti-tail of Comet Kohoutek must be larger than about 10 microns diameter. The observations give an absolute upper limit to the diameter of Comet Kohoutek of 30 km. A consistent interpretation would indicate that Comets Kohoutek and Bradfield have nuclear diameters of 5 to 10 km, that Bennett was several times larger, and that P/Encke is 10 times smaller. The peculiar behavior of Bradfield showed that the coma of a single comet can abruptly change its dust composition.
Results are presented from OSO-8 and HEAO-1 A2 observations of 34 bursts from the X-ray burster MXB1916-053/4U1915-05 recently discovered to show a 50 minute binary period. While 11 burst previously reported all had similar light curves, 22 observed two years later show a factor of 3 range of peak fluxes and decay times between 3 and 20 s. Recurrence times between successive bursts vary between 3 and 6 hours. A ratio of steady flux to average burst flux of equiv 120 is developed. A burst observed with the HEAO-1 A2 experiment showed an initial temperature rise to a peak black body temperature of equiv 3 keV followed by the cooling typical of type I bursts. The burst was unusual in that the apparent projected size of a blackbody source increased by a factor of 3 during the cooling phase.
Results are presented from OSO-8 and HEAO-1 A2 observations of 34 bursts from the X-ray burster MXB 1916-053/4U 1915-05 recently discovered to show a 50 minute binary period. While 11 burst previously reported all had similar light curves, 22 observed two years later show a factor of 3 range of peak fluxes and decay times between 3 and 20 s. Recurrence times betweeen successive bursts vary between 3 and 6 hours. A ratio of steady flux to average burst flux of equiv 120 is developed. A burst observed with the HEAO-1 A2 experiment showed an initial temperature rise to a peak black body temperature of equiv 3 keV followed by the cooling typical of type I bursts. The burst was unusual in that the apparent projected size of a blackbody source increased by a factor of 3 during the cooling phase. Previously announced in STAR as N83-34872
The temperature dependent thermal properties of a material may be evaluated from transient temperature histories using nonlinear parameter estimation techniques. The usual approach is to minimize the sum of the squared errors between measured and calculated temperatures at specific locations in the body. Temperature measurements are usually made with thermocouples and it is customary to take thermocouple locations as known and fixed during parameter estimation computations. In fact, thermocouple locations are never known exactly. Location errors on the order of the thermocouple wire diameter are intrinsic to most common instrumentation procedures (e.g., inserting a thermocouple into a drilled hole) and additional errors can be expected for delicate materials, difficult installations, large thermocouple beads, etc.. Thermocouple location errors are especially significant when estimating thermal properties of low diffusively materials which can sustain large temperature gradients during testing. In the present work, a parameter estimation formulation is presented which allows for the direct inclusion of thermocouple positions into the primary parameter estimation procedure. It is straightforward to set bounds on thermocouple locations which exclude non-physical locations and are consistent with installation tolerances. Furthermore, bounds may be tightened to an extent consistent with any independent verification of thermocouple location, such as x-raying, and so the procedure is entirely consonant with experimental information. A mathematical outline of the procedure is given and its implementation is illustrated through numerical examples characteristic of light-weight, high-temperature ceramic insulation during transient heating. The efficacy and the errors associated with the procedure are discussed.
Three male swimmers underwent 10-min resting and 20-min swimming (breaststroke) exposures in a swimming flume. Water temperatures in separate exposures were 18, 26, and 33 C. At each water temperature the subjects rested and swam at water velocities of 0.50, 0.75, and 0.95 m/sec, which were designed to produce around 40, 70, and 100% of maximal aerobic power. Measurements were made of esophageal temperature, four skin temperatures, water temperature, heat flow from five local skin surfaces (Hatfield-Turner disks), and oxygen uptake. Calculations were made of mean area-weighted skin temperature and heat flow, metabolic rate, and heat storage. Internal body temperature changes after 20 min of swimming were related to water temperature, swimming intensity, and body composition.
This study explored the relationship between circadian performance rhythms and rhythms in rectal temperature, plasma cortisol, plasma melatonin, subjective alertness and well-being. Seventeen healthy young adults were studied under 36 h of 'unmasking' conditions (constant wakeful bedrest, temporal isolation, homogenized 'meals') during which rectal temperatures were measured every minute, and plasma cortisol and plasma melatonin measured every 20 min. Hourly subjective ratings of global vigour (alertness) and affect (well-being) were obtained followed by one of two performance batteries. On odd-numbered hours performance (speed and accuracy) of serial search, verbal reasoning and manual dexterity tasks was assessed. On even-numbered hours, performance (% hits, response speed) was measured at a 25-30 min visual vigilance task. Performance of all tasks (except search accuracy) showed a significant time of day variation usually with a nocturnal trough close to the trough in rectal temperature. Performance rhythms appeared not to reliably differ with working memory load. Within subjects, predominantly positive correlations emerged between good performance and higher temperatures and better subjective alertness; predominantly negative correlations between good performance and higher plasma levels of cortisol and melatonin. Temperature and cortisol rhythms correlated with slightly more performance measures (5/7) than did melatonin rhythms (4/7). Global vigour correlated about as well with performance (5/7) as did temperature, and considerably better than global affect (1/7). In conclusion: (1) between-task heterogeneity in circadian performance rhythms appeared to be absent when the sleep/wake cycle was suspended; (2) temperature (positively), cortisol and melatonin (negatively) appeared equally good as circadian correlates of performance, and (3) subjective alertness correlated with performance rhythms as well as (but not better than) body temperature, suggesting that performance rhythms were not directly mediated by rhythms in subjective alertness.
Critical body temperature for intracranial self stimulation in white rats
Human body temperature regulation under various hydration regimes during exercise, noting changes related to sweating
It is shown that the body temperature rise during physical exercise is a regulated process and is not due to a failure of heat-dissipating mechanisms. Core and skin temperatures do not provide sufficient information to account for the control of sweating during exercise. Evidence is presented that suggests an association between equilibrium levels of rectal temperature and the osmotic concentration of the blood with essentially no influence from variations in plasma volume.-
Daily physiological rhythm changes associated with light intensity and color, noting body temperature oscillations vs light intensity, heart rate changes, etc
Circadian rhythms of body temperature and activity cycles in humans exposed to weak alternating electric field
Personal cooling systems are used to alleviate symptoms of multiple sclerosis and to prevent increased core temperature during daily activities. The objective of this study was to determine the thermal and physiologic responses of patients with multiple sclerosis to short-term maximal head and neck cooling. A Life Support Systems, Inc. Mark VII portable cooling system and a liquid cooling helmet were used to cool the head and neck regions of 24 female and 26 male patients with multiple sclerosis in this study. The subjects, seated in an upright position at normal room temperature (approximately 22 degrees C), were cooled for 30 min by the liquid cooling garment, which was operated at its maximum cooling capacity. Oral, right, and left ear temperatures and cooling system parameters were logged manually every 5 min. Forearm, calf, chest, and rectal temperatures, heart rate, and respiration rate were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. This protocol was performed during the winter and summer to investigate the seasonal differences in the way patients with multiple sclerosis respond to head and neck cooling. No significant differences were found between the male and female subject group's mean rectal or oral temperature responses during any phase of the experiment. The mean oral temperature decreased significantly (P < 0.05) for both groups approximately 0.3 degrees C after 30 min of cooling and continued to decrease further (approximately 0.1-0.2 degrees C) for a period of approximately 15 min after removal of the cooling helmet. The mean rectal temperatures decreased significantly (P < 0.05) in both male and female subjects in the winter studies (approximately 0.2-0.3 degrees C) and for the male subjects during the summer test (approximately 0.2 degrees C). However, the rectal temperature of the female subjects did not change significantly during any phase of the summer test. These data indicate that head and neck cooling may, in general, be used to reduce the oral and body temperatures of both male and female patients with multiple sclerosis by the approximate amount needed for symptomatic relief as shown by other researchers. However, thermal response of patients with multiple sclerosis may be affected by gender and seasonal factors, which should be considered in the use of liquid cooling therapy.