Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BREAKDOWN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

From Organized High-Throughput Data to Phenomenological Theory using Machine Learning: The Example of Dielectric Breakdown

Understanding the behavior (and failure) of dielectric insulators experiencing extreme electric fields is critical to the operation of present and emerging electrical and electronic devices. Despite its importance, the development of a predictive theory of dielectric breakdown has remained a challenge, owing to the complex multiscale nature of this process. We focus on the intrinsic dielectric breakdown field of insulators—the theoretical limit of breakdown determined purely by the chemistry of the material, i.e., the elements the material is composed of, the atomic-level structure, and the bonding. Starting from a benchmark dataset (generated from laborious first principles computations) of the intrinsic dielectric breakdown field of a variety of model insulators, simple predictive phenomenological models of dielectric breakdown are distilled using advanced statistical or machine learning schemes, revealing key correlations and analytical relationships between the breakdown field and easily accessible material properties. Lastly, the models are shown to be general, and can hence guide the screening and systematic identification of high electric field tolerant materials.

36 MATERIALS SCIENCE↗

Microcontroller based system for electrical breakdown time delay measurement in gas-filled devices

This paper presents realization of a digital embedded system for measuring electrical breakdown time delay. The proposed system consists of three major parts: dc voltage supply, analog subsystem, and a digital subsystem. Any dc power source with the range from 100 to 1000 V can be used in this application. The analog subsystem should provide fast and accurate voltage switching on the testing device as well as transform the signals that represent the voltage pulse on the device and the device breakdown into the form suitable for detection by a digital subsystem. The insulated gate bipolar transistor IRG4PH40KD driven by TC429 MOSFET driver is used for high voltage switching on the device. The aim of a digital subsystem is to detect the signals from the analog subsystem and to measure the elapsed time between their occurrences. Moreover, the digital subsystem controls various parameters that influence time delay and provides fast data storage for a large number of measured data. For this propose, we used the PIC18F4550 microcontroller with a full-speed compatible universal serial bus (USB) engine. Operation of this system is verified on different commercial and custom made gas devices with different structure and breakdown mechanisms. The electrical breakdown time delay measurements have been carried out as a function of several parameters, which dominantly influence electrical breakdown time delay. The obtained results have been verified using statistical methods, and they show good agreement with the theory. The proposed system shows good repeatability, sensitivity, and stability for measuring the electrical breakdown time delay.

36 MATERIALS SCIENCE↗

Dielectric breakdown field of strained silicon under hydrostatic pressure

First-principles density functional theory calculations are used to reveal a quantitative relationship between the dielectric breakdown field and hydrostatic pressure of crystalline Si. The electronic band structure, phonon dispersion, and electron scattering rate are computed for pressures from 62.2 kbar (compressive) to -45.6 kbar (tensile) to estimate the rate of kinetic energy gain and loss for the electron. The theoretical dielectric breakdown fields are then determined using the von Hippel–Fröhlich criterion. Compressive stresses lead to a lower breakdown field, while significant increases in the dielectric breakdown field can be achieved by tensile stresses. Strain engineering in Si technology enables efficient control of hole and electron mobilities without changing the chemical composition or making structural modifications to achieve the target performance of microelectronic applications. Under certain stress conditions, however, Si experiences a narrowing of the bandgap, leading to an increase in leakage current, or a reduction in the dielectric breakdown field, leading to a device less endurable under high electric fields. As applications rapidly scale down, these disadvantages become critical. A clear understanding of the relationship between strain and dielectric breakdown behaviors becomes useful.

36 MATERIALS SCIENCE↗

Gas breakdown and its scaling law in microgaps with multiple concentric cathode protrusions

This work reports gas breakdown characteristics in microgaps with multiple concentric protrusions on the cathode in the transition from the Townsend to the subnormal glow discharge regime, using a two-dimensional hydrodynamic model. The effects of the protrusion aspect ratio, height, and protrusion spacing on the breakdown voltage are investigated. The results show that when the protrusion spacing is small, the shielding effect can play a more important role in the breakdown voltage rather than the protrusion aspect ratio; the breakdown voltage is more sensitive to the protrusion height and can be assessed by the shortest gap distance. Increasing the protrusion spacing decreases the shielding effect, which lowers the breakdown voltage in both low- and high-pressure regimes. It is found that the breakdown scaling law still holds in geometrically similar microgaps with multiple cathode protrusions despite the electric field distortion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Unintended gas breakdowns in narrow gaps of advanced plasma sources for semiconductor fabrication industry

Occurrence of unintended gas breakdown in the narrow gaps of plasma processing chambers is one of the critical challenges in developing advanced plasma sources. Here, we present a combined experimental and theoretical study of unintended discharges in the narrow gaps of plasma processing chambers and report significant drop of the gas breakdown voltage in the presence of a background plasma facing the gap. Experimentally measured breakdown voltages decrease in subsequent breakdown events due to wall erosion caused by the discharge. Therefore, preventing and mitigating the first discharge is of paramount importance. An analysis of kinetic simulation results indicates that the charged particle influx from the background plasma in the processing chamber into the gap is responsible for the onset of early breakdown: higher charged particle density within the gap modifies the electric field profile, allowing unintended breakdowns to occur at a significantly reduced threshold voltage.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-fidelity modeling of breakdown in helium: initiation processes and secondary electron emission

Understanding the role of physical processes contributing to breakdown is critical for many applications in which breakdown is undesirable, such as capacitors, and applications in which controlled breakdown is intended, such as plasma medicine, lightning protection, and materials processing. The electron emission from the cathode is a critical source of electrons which then undergo impact ionization to produce electrical breakdown. In this study, the role of secondary electron yields due to photons (γ ph ) and ions (γ i ) in direct current breakdown is investigated using a particle-in-cell direct simulation Monte Carlo model. The plasma studied is a one-dimensional discharge in 50 Torr of pure helium with a platinum cathode, gap size of 1.15 cm, and voltages of 1.2–1.8 kV. The current traces are compared with experimental measurements. Larger values of γ ph generally result in a faster breakdown, while larger values of γ i result in a larger maximum current. The 58.4 nm photons emitted from He(2 1 P) are the primary source of electrons at the cathode before the cathode fall is developed. Of the values of γ ph and γ i investigated, those which provide the best agreement with the experimental current measurements are γ ph = 0.005 and γ i = 0.01. In this work, these values are significantly lower than those in the literature for pristine platinum or for a graphitic carbon film which we speculate may cover the platinum. This difference is in part due to the limitations of a one-dimensional model but may also indicate surface conditions and exposure to a plasma can have a significant effect on the secondary electron yields. The effects of applied voltage and the current produced by a UV diode which was used to initiate the discharge, are also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Breakdown insensitive acceleration regime in a metamaterial accelerating structure

A new regime in radiofrequency (rf) breakdown, named the breakdown insensitive acceleration regime (BIAR), was observed in an 11.7 GHz metamaterial structure for wakefield acceleration driven by rf pulses with a duration of a few nanoseconds. In the BIAR, rf breakdown occurs without interrupting potential beam acceleration, resulting in greater resilience to breakdown. We have investigated the possibility that BIAR can support higher gradients by characterizing the breakdown in a high-power test. The peak gradient reached 190 MV / m when the structure was powered by 6 ns long rf pulses with 115 MW peak power. The short rf pulses were extracted from 65 MeV electron bunch trains with a total charge of up to 210 nC. This work has revealed the benefits of short-pulse acceleration by characterizing rf breakdown in the previously unexplored parameter space. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Experimental study of the processes accompanying argon breakdown in a long discharge tube at a reduced pressure

Results are presented from experimental studies of the breakdown stage of a low-pressure discharge (1 and 5 Torr) in a glass tube the length of which (75 cm) is much larger than its diameter (2.8 cm). Breakdowns occurred under the action of positive voltage pulses with an amplitude of up to 9.4 kV and a characteristic rise time of 2–50 μs. The discharge current in the steady-state mode was 10–120 mA. The electrode voltage, discharge current, and radiation from the discharge gap were detected simultaneously. The dynamic breakdown voltage was measured, the prebreakdown ionization wave was recorded, and its velocity was determined. The dependence of the discharge parameters on the time interval between voltage pulses (the socalled “memory effect”) was analyzed. The memory effect manifests itself in a decrease or an increase in the breakdown voltage and a substantial decrease in its statistical scatter. The time interval between pulses in this case can reach 0.5 s. The effect of illumination of the discharge tube with a light source on the breakdown was studied. It is found that the irradiation of the anode region of the tube by radiation with wavelengths of ≤500 nm substantially reduces the dynamic breakdown voltage. Qualitative explanations of the obtained results are offered.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Humidity effects on wire insulation breakdown strength.

Methods for the testing of the dielectric breakdown strength of insulation on metal wires under variable humidity conditions were developed. Two methods, an ASTM method and the twisted pair method, were compared to determine if the twisted pair method could be used for determination of breakdown strength under variable humidity conditions. It was concluded that, although there were small differences in outcomes between the two testing methods, the non-standard method (twisted pair) would be appropriate to use for further testing of the effects of humidity on breakdown performance. The dielectric breakdown strength of 34G copper wire insulated with double layer Poly-Thermaleze/Polyamide-imide insulation was measured using the twisted pair method under a variety of relative humidity (RH) conditions and exposure times. Humidity at 50% RH and below was not found to affect the dielectric breakdown strength. At 80% RH the dielectric breakdown strength was significantly diminished. No effect for exposure time up to 140 hours was observed at 50 or 80%RH.

Appelhans, Leah↗

Time Delay from Corona to Breakdown

This report describes measurements of the time delay between the onset of corona and complete electrical breakdown between a point and a plane in dry air near atmospheric pressure as a function of the distance between the point and the plane. The large variation in these time delays is representative of the stochastic nature of electrical breakdown and the many possible phenomena that occur between the initiation and completion of electrical breakdown, including initiation without complete electrical breakdown. The purpose of this work is to provide data which will be accurately modeled when a model contains the appropriate mechanisms with the proper priorities to describe this fundamental electrical breakdown configuration. The acquisition of these measurements completes a level three milestone for the WSEAT program which sponsors this research. Also included in this report is a description of our plans to “automate” the experimental procedure, protect the high sensitivity fast-gated camera, and add diagnostics and new experimental techniques to the test facility. This will provide measurements of the time delay distributions with improved statistics and additional experimental information about the processes that occur during electrical breakdown.

42 ENGINEERING↗

Numerical simulation of vortex breakdown by the vortex-filament method

The vortex filament method was applied to the simulation of vortex breakdown. The principal vortex region was represented by multiple filaments, and an axial velocity component was induced by a spiral winding of the filaments. First, an accuracy check was performed for a cylindrical swirling flow with simple analytical expressions for the axial and theta velocities. The result suggests that the flow field is simulated to any accuracy by increasing the number of filaments. Second, an axisymmetric type vortex breakdown was simulated, with experimental data serving as upstream conditions. The calculated axial and theta velocity contours show the breakdown of the vortex, including a rapid change in the vortex core, followed axially by a recovery zone and then a second breakdown. When three dimensional initial data are used the second breakdown appears to be of the spiral type in correspondence with experimental observations. The present method is easily used to simulate other types of vortex breakdown or other vortex flows with axial velocity.

Nakamura, Y.↗

Numerical simulation of vortex breakdown by the vortex-filament method

The vortex-filament method was applied to the simulation of vortex breakdown. The principal vortex region was represented by multiple filaments, and an axial velocity component was induced by a spiral winding of the filaments. An accuracy check was performed for a cylindrical swirling flow with simple analytical expressions for the axial and theta velocities. The result suggests that the flow field can be simulated to any accuracy by increasing the number of filaments. An axisymmetric-type vortex breakdown was simulated, with experimental data serving as upstream conditions. The calculated axial- and theta-velocity contours show the breakdown of the vortex, including a rapid change in the vortex core, followed axially by a recovery zone and then a second breakdown. When three dimensional initial data are used the second breakdown appears to be of the spiral type in correspondence with experimental observations. The present method can easily be used to simulate other types of vortex breakdown or other vortex flows with axial velocity.

Nakamura, Y.↗

Internal structure of a vortex breakdown

An axisymmetric vortex breakdown was well simulated by the vortex filament method. The agreement with the experiment was qualitatively good. In particular, the structure in the interior of the vortex breakdown was ensured to a great degree by the present simulation. The second breakdown, or spiral type, which occurs downstream of the first axisymmetric breakdown, was simulated more similarly to the experiment than before. It shows a kink of the vortex filaments and strong three-dimensionality. Furthermore, a relatively low velocity region was observed near the second breakdown. It was also found that it takes some time for this physical phenomenon to attain its final stage. The comparison with the experiment is getting better as time goes on. In this paper, emphasis is placed on the comparison of the simulated results with the experiment. The present results help to make clear the mechanism of a vortex breakdown.

Nakamura, Y.↗

On a criterion for vortex breakdown

A criterion for the onset of vortex breakdown is proposed. Based upon previous experimental, computational, and theoretical studies, an appropriately defined local Rossby number is used to delineate the region where breakdown occurs. In addition, new numerical results are presented which further validate this criterion. A number of previous theoretical studies concentrating on inviscid standing-wave analyses for trailing wing-tip vortices are reviewed and reinterpreted in terms of the Rossby number criterion. Consistent with previous studies, the physical basis for the onset of breakdown is identified as the ability of the flow to sustain such waves. Previous computational results are reviewed and re-evaluated in terms of the proposed breakdown criterion. As a result, the cause of breakdown occurring near the inflow computational boundary, common to several numerical studies, is identified. Finally, previous experimental studies of vortex breakdown for both leading edge and trailing wing-tip vortices are reviewed and quantified in terms of the Rossby number criterion.

Spall, R. E.↗

A criterion for vortex breakdown

A criterion for the onset of vortex breakdown is proposed. Based upon previous experimental, computational, and theoretical studies, an appropriately defined local Rossby number is used to delineate the region where breakdown occurs. In addition, new numerical results are presented which further validate this criterion. A number of previous theoretical studies concentrating on inviscid standing-wave analyses for trailing wing-tip vortices are reviewed and reinterpreted in terms of the Rossby number criterion. Consistent with previous studies, the physical basis for the onset of breakdown is identified as the ability of the flow to sustain such waves. Previous computational results are reviewed and re-evaluated in terms of the proposed breakdown criterion. As a result, the cause of breakdown occurring near the inflow computational boundary, common to several numerical studies, is identified. Finally, previous experimental studies of vortex breakdown for both leading edge and trailing wing-tip vortices are reviewed and quantified in terms of the Rossby number criterion.

Spall, R. E.↗

An experimental analysis of critical factors involved in the breakdown process of leading edge vortex flows

Experimental crosswire measurements of the flowfield above a 70 and 75 degree flat plate delta wing were performed at a Reynolds number of 250,000. Survey grids were taken normal to the platform at a series of chordwise locations for angles of attack of 20 and 30 degrees. Axial and azimuthal vorticity distributions were derived from the velocity fields. The dependence of circulation on distance from the vortex core as well as on chordwise location was examined. The effects of nondimensionalization in comparison with other experimental data was made. The circulation distribution scales with the local semispan and grows approximately linearly in the chordwise direction. For regions of the flow outside of the vortex subcore, the circulation at any chordwise station was observed to vary logarithmically with distance from the vortex axis. The circulation was also found to increase linearly with angle of incidence at a given chordwise station. A reduction in the local circulation about the vortex axis occurred at breakdown. The spanwise distribution of axial vorticity was severely altered through the breakdown region and the spanwise distribution of axial vorticity present appeared to reach a maximum immediately preceding breakdown. The local concentration of axial vorticity about the vortex axis was reduced while the magnitude of the azimuthal vorticity decreased throughout the breakdown zone. The axial vorticity components with a negative sense, found in the secondary vortex, remained unaffected by changes in wing sweep or angle of attack, in direct contrast to the positive components. The inclusion of the local wing geometry into a previously derived correlation parameter indicated that the circulation of growing leading edge vortex flows were similar at corresponding radii from the vortex axis. It was concluded that the flow over a delta wing, upstream of the breakdown regions and away from the apex and trailing edge regions, is conical. In addition, the dominating factors leading to the onset of breakdown are felt to be the local circulation of the vortex and the accompanying pressure field.

Visser, Kenneth D.↗

Study of Bulk and Elementary Screw Dislocation Assisted Reverse Breakdown in Low-Voltage (less than 250 V) 4H-SiC p(+)n Junction diodes: DC Properties - Part 1

Given the high density (approx. 10(exp 4)/sq cm) of elementary screw dislocations (Burgers vector = 1c with no hollow core) in commercial SiC wafers and epilayers, all appreciable current (greater than 1 A) SiC power devices will likely contain elementary screw dislocations for the foreseeable future. It is therefore important to ascertain the electrical impact of these defects, particularly in high-field vertical power device topologies where SiC is expected to enable large performance improvements in solid-state high-power systems. This paper compares the DC-measured reverse-breakdown characteristics of low-voltage (less than 250 V) small-area (less than 5 x 10(exp -4)/sq cm) 4H-SiC p(+)n diodes with and without elementary screw dislocations. Compared to screw dislocation-free devices, diodes containing elementary screw dislocations exhibited higher pre-breakdown reverse leakage currents, softer reverse breakdown I-V knees, and highly localized microplasmic breakdown current filaments. The observed localized 4H-SiC breakdown parallels microplasmic breakdowns observed in silicon and other semiconductors, in which space-charge effects limit current conduction through the local microplasma as reverse bias is increased.

Neudeck, Philip G.↗

Study of Bulk and Elementary Screw Dislocation Assisted Reverse Breakdown in Low-Voltage (<250 V) 4H-SiC p+n Junction Diodes - Part 1: DC Properties

Given the high density (approx. 10(exp 4)/sq cm) of elementary screw dislocations (Burgers vector = lc with no hollow core) in commercial SiC wafers and epilayers, all appreciable current (greater than 1 A) SiC power devices will likely contain elementary screw dislocations for the foreseeable future. It is therefore important to ascertain the electrical impact of these defects, particularly in high-field vertical power device topologies where SiC is expected to enable large performance improvements in solid-state high-power systems. This paper compares the DC-measured reverse-breakdown characteristics of low-voltage (less than 250 V) small-area (less than 5 x 10(exp -4) sq cm) 4H-SiC p(+)n diodes with and without elementary screw dislocations. Compared to screw dislocation-free devices, diodes containing elementary screw dislocations exhibited higher pre-breakdown reverse leakage currents, softer reverse breakdown I-V knees, and highly localized microplasmic breakdown current filaments. The observed localized 4H-SiC breakdown parallels microplasmic breakdowns observed in silicon and other semiconductors, in which space-charge effects limit current conduction through the local microplasma as reverse bias is increased.

Neudeck, Philip G.↗