Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Associated Storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

[LCA UP] Processing and Liquefaction of NG and Storage of LNG DY2020

This unit process includes pipeline gas input, energy requirements, emissions, and losses, associated with processing, liquefaction and storage of natural gas at six different U.S. liquefaction facilities before it is exported.

LCA Unit Process; Liquified Natural Gas; Natural G↗

Solid State Solar Thermochemical Fuel (SoFuel) for Long Duration Storage

Efficient thermal storage systems, when coupled with renewable energy, enable the decarbonization of numerous industrial processes requiring high temperature steam or air, and provide a path for seasonal building heating, especially for colder climates. Existing thermal storage systems face a significant challenge due to losses inherent to all high temperature systems. A viable route to long-term storage is to use thermochemical reactions to convert concentrated solar energy to a fuel that is shelf-stable and can be stored at room temperature, thus eliminating losses associated with high temperature storage. The Solid-State Solar Thermochemical Fuel (SoFuel) technology developed by Michigan State University, Oregon State University, and Mississippi State University provides reactors and processes with minimal sensible heat losses and allows storing solar energy as a solid-state fuel at room temperature for long duration. The production of SoFuel occurs within a cylindrical cavity reduction chemical reactor that captures concentrated solar radiation from a solar field. Reactive magnesium manganese oxide (Mg-Mn-O) resides within the cylindrical cavity chemical reactor and undergoes thermal reduction as the temperature exceeds 1350°C. The thermally reduced Mg-Mn-O pellets (the SoFuel) are cooled down through a recuperative process and stored within a bin until used. The SoFuel can directly supply up to 1100°C heat to an adjacent power plant for electricity generation or industrial heating. Oxidation of SoFuel pellets occurs in a counter flow reactor and supplies heat to the user for electricity generation or industrial processing, after which the fuel is returned to the concentrating solar field where it is regenerated for re-use. Both reactors can be controlled well using a variety of strategies. With the low cost of the material, its cyclability, and the possibility of using the pelletized with on-sun reactors, or with electricity that would be curtailed, this project offers a viable option of medium- and long-term thermal energy storage.

14 SOLAR ENERGY↗

Solid State Solar Thermochemical Fuel (SoFuel) for Long Duration Storage

Efficient thermal storage systems, when coupled with renewable energy, enable the decarbonization of numerous industrial processes requiring high temperature steam or air, and provide a path for seasonal building heating, especially for colder climates. Existing thermal storage systems face a significant challenge due to losses inherent to all high temperature systems. A viable route to long-term storage is to use thermochemical reactions to convert concentrated solar energy to a fuel that is shelf-stable and can be stored at room temperature, thus eliminating losses associated with high temperature storage. The Solid-State Solar Thermochemical Fuel (SoFuel) technology developed by Michigan State University, Oregon State University, and Mississippi State University provides reactors and processes with minimal sensible heat losses and allows storing solar energy as a solid-state fuel at room temperature for long duration. The production of SoFuel occurs within a cylindrical cavity reduction chemical reactor that captures concentrated solar radiation from a solar field. Reactive magnesium manganese oxide (Mg-Mn-O) resides within the cylindrical cavity chemical reactor and undergoes thermal reduction as the temperature exceeds 1350°C. The thermally reduced Mg-Mn-O pellets (the SoFuel) are cooled down through a recuperative process and stored within a bin until used. The SoFuel can directly supply up to 1100C heat to an adjacent power plant for electricity generation or industrial heating. Oxidation of SoFuel pellets occurs in a counter flow reactor and supplies heat to the user for electricity generation or industrial processing, after which the fuel is returned to the concentrating solar field where it is regenerated for re-use. Both reactors can be controlled well using a variety of strategies. With the low cost of the material, its cyclability, and the possibility of using the pelletized with on-sun reactors, or with electricity that would be curtailed, this project offers a viable option of medium- and long-term thermal energy storage.

25 ENERGY STORAGE↗

Dynamics and controls working group summary

The technology status of the dynamics and controls discipline as it applies to energy storage wheel systems was evaluated. No problems were identified for which an adequate solution could not be proposed. Design issues that influence control were addressed. The dynamics and control aspects associated with the energy storage system concept and its various constituent parts, and the control tasks attendant to large, manned spacecraft are discussed.

Oglevie, R. E.↗

Deep Learning–Assisted Multiobjective Optimization of Geological CO 2 Storage Performance under Geomechanical Risks

In geological CO 2 storage, designing the optimal well control strategy for CO 2 injection to maximize CO 2 storage while minimizing the associated geomechanical risks is not trivial. This challenge arises due to pressure buildup, CO 2 plume migration, the highly nonlinear nature of geomechanical responses to rock-fluid interaction, and the high computational cost associated with coupled flow and geomechanics simulations. In this paper, we introduce a novel optimization framework to address these challenges. The optimization problem is formulated as follows: maximize total CO 2 storage while minimizing geomechanical risks by adjusting the injection schedules within bounded constraints. The geomechanical risks are primarily driven by injection-induced pressure build-up, which is characterized by ground displacement and the induced microseismicity. We used the Fourier neural operator (FNO)-based deep learning model to construct surrogate models, replacing the time-consuming coupled flow and geomechanics simulations for evaluating the aforementioned objective functions. The developed surrogate models have been incorporated into a multiobjective optimization framework through a genetic algorithm to reduce the computational burden. The proposed optimization framework reduces the computational cost from approximately 2,400 hours, when using objective function evaluations based on physics-based simulations, to around 20 minutes. A set of Pareto-optimal solutions of the proposed workflow yields nontrivial optimal decisions, reducing the microseismicity potential and the vertical displacement. This Pareto front highlights the optimal trade-offs between CO 2 storage amount, safety, and ground displacement, emphasizing the need for careful optimization and management of injection strategies to achieve a balanced outcome. The novelty of this work is twofold. First, we demonstrate the importance of incorporating the minimization of the geomechanical risks as objective functions into the CO 2 storage optimization workflow to mitigate the potential risk of induced microseismicity and ground displacement. Second, we leverage the FNO-based surrogate models to optimize a real-field CO 2 storage operation.

42 ENGINEERING↗

Drying and Analysis of Aluminum (Oxy)hydroxide Films for Dry Storage of Aluminum-Clad Spent Nuclear Fuels

In aluminum-clad spent nuclear fuels, an (oxy)hydroxide layer on the surface of the cladding hosts chemisorbed water formed during reactor and post-discharge exposure to water. Any residual water is susceptible to generating hydrogen via radiolysis, which can be a risk associated with dry fuel storage. Engineering-scale forced helium dehydration (FHD) and vacuum drying tests were conducted on mock-up fuel assemblies that included corroded aluminum surrogate plates to assess the removal of bulk and chemisorbed water. Thermogravimetric analysis was performed on samples of the surrogate plates, both undried control samples used to determine onset temperatures associated with a phase change occurring in the oxide layer and samples from drying tests used to determine the effectiveness of each drying method. Both vacuum drying and FHD processes were capable of removing bulk water. However, FHD was determined to provide additional drying capabilities, including partial removal of chemisorbed water from bayerite due to the higher temperatures during drying. In conclusion, the temperature threshold for partial dehydroxylation of the oxide layer was determined to be around 220°C, meaning any drying methods attempting to remove chemisorbed water must exceed 220°C.

chemisorbed water↗

Pumped Storage Hydropower Augmented with Pressurized Air: The Ground-Level Integrated Diverse Energy Storage (GLIDES) System — GLIDES System Configurations and Use Cases

Energy storage is essential for cost-effective integration of variable renewable energy sources to support a low-carbon grid. It is also a key enabler of a modern grid infrastructure for demand management. However, several main challenges remain for different kind of energy storage technologies in grid scale deployment. Currently, the largest source of utility-scale storage and long-duration storage in the US is pumped storage hydropower (PSH). Prospect of growth in conventional PSH faces challenges that have limited its deployment over the last three decades, including high capital costs and long deployment timelines. Batteries have high energy densities and are the primary technology of choice for small-scale energy storage. Compressed air energy storage (CAES) is another large-scale energy storage technology, but there are few plants deployed worldwide. They suffer from their low round trip efficiency (RTE) due to the use of high-pressure air compressors. To address some of the challenges associated with these various storage technologies, the Ground-Level Integrated Diverse Energy Storage (GLIDES) is a modular PSH technology that was invented in 2015 at Oak Ridge National Laboratory. It utilizes gas compression to store electric energy. GLIDES stores energy by compressing gas using a liquid piston in high-pressure vessels. In doing so the vessels act as the upper reservoir in conventional PSH. Initially, the vessels are filled with gas to a prescribed pressure. To store energy, GLIDES uses a hydraulic piston pump to pump water into the pressurized vessels. As the water volume increases inside the vessels, water acts as a hydraulic piston compressing the gas on top of it. This process can be thought of as pumping water from the lower reservoir to the higher reservoir in PSH, increasing the water head. To dispatch the stored energy, the high-head water in the vessel is discharge through a high head Pelton hydraulic turbine that is connected to an electric generator. Employing high-pressure vessels enables GLIDES to reach water heads ~10-80 times higher than conventional PSH, achieving ~40 times higher energy densities, and overcomes the geographic limitation of conventional PSH. Although its energy density is much lower than that of batteries, GLIDES holds the potential advantages of having long service life, ease of system integration and being less hazardous over batteries. GLIDES prospective scalability could make it suitable for wide range of applications from behind the meter storage in buildings to grid-scale storage. It also makes it suitable for installations in densely populated urban areas where energy storage is most needed and real estate is limited. Over the last 5 years, work has focused on increasing GLIDES’ energy density, decreasing its initial capital cost of the system, and increasing its revenue potential. Several designs were developed and prototyped to verify and demonstrate the improvement in energy density. The latest prototype achieved energy density of 1.21 kWh/m 3 . Our analysis showed that it could achieve up to 1.7 kWh/m 3 with a mixture of air and carbon dioxide as the gas being compressed.

13 HYDRO ENERGY↗

Evidence of pathogenic microbes in the International Space Station drinking water: reason for concern?

Molecular analyses were carried out on four preflight and six postflight International Space Station (ISS)-associated potable water samples at various stages of purification, storage, and transport, to ascertain their associated microbial diversities and overall microbial burdens. Following DNA extraction, PCR amplification, and molecular cloning procedures, rDNA sequences closely related to pathogenic species of Acidovorax, Afipia, Brevundimonas, Propionibacterium, Serratia, and others were recovered in varying abundance. Retrieval of sequences arising from the iodine (biocide)-reducing Delftia acidovorans in postflight waters is also of concern. Total microbial burdens of ISS potable waters were derived from data generated by an ATP-based enumeration procedure, with results ranging from 0 to 4.9 x 10(4) cells/ml. Regardless of innate biases in sample collection and analysis, such circumstantial evidence for the presence of viable, intact pathogenic cells should not be taken lightly. Implementation of new cultivation approaches and/or viability-based assays are requisite to confirm such an occurrence.

STS-113 Shuttle Project↗

Architecture and Component Selection for the Remote Canister-Monitoring System

This report documents the selected system architecture and components surveyed for the development of a remote, canister-monitoring system (RCMS) for determining and monitoring environmental conditions within dry fuel storage canisters containing aluminum-clad spent nuclear fuel (ASNF) at Idaho National Laboratory (INL). These efforts are in support of the Department of Energy Office of Environmental Management (DOE-EM) investigations into the technical issues associated with extended dry storage (50+ years) of ASNF. It is important to resolve questions regarding storage because the ATR is expected to continue producing approximately 100 elements of spent fuel per year for at least another twenty years. The parameters to be monitored by the RCMS include temperature, relative humidity, hydrogen gas concentration, and radiation environment (dose). Components are selected based on the expected environmental conditions within the canister and fuel storage area and the desired performance of the RCMS. Several of these components have been purchased and are currently undergoing component testing to confirm their suitability for use in delivering the RCMS. Additional components may be identified through the course of design and may be selected in the future. Furthermore, changing performance, interfacing, and compatibility requirements and the results of component testing may necessitate revisiting component selection.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hydrogen Fire in a Storage Vessel

On October 23, 2007, the operations team began a procedure to sample the Liquid Hydrogen (LH2) storage vessels ("tanks"), and associated transfer system. This procedure was being performed to determine the conditions within the system, and if necessary, to purge the system of any excess Gaseous Hydrogen (GH2) in preparation for reactivation of the system. The system had not been used since 2003. The LH2 storage system contains two (2) spherical pressure vessels of 225,000 gallons in volume, with a maximum working pressure (MAWP) of 50 psig. Eight inch transfer piping connects them to the usage point. Operations began with activation of the burnstack for the LH2 storage area. Pneumatic (GN2) systems in the storage area were then activated and checked. Pressurization of storage tank number 1 with gaseous nitrogen (GN2) was initiated, with a target pressure of 10 psig, at which point samples were planned to be taken. At 5 psig, a loud noise was heard in the upper area of tank number 2. Smoke was seen exiting the burnstack and from the insulation on vent lines for both tanks. At this time tank number 1 was vented and the pressurization system was secured. The mishap resulted in physical damage to both storage tanks, as well as to some of the piping for both tanks. Corrective action included repair of the damaged hardware by a qualified contractor. Preventive action included documented organizational policy and procedures for establishing standby and mothball conditions for facilities and equipment, including provisions as detailed in the investigation report recommendations: Recommendation 1: The using organization should define necessary activities in order to place hydrogen systems in long term periods of inactivity. The defined activities should address requirements for rendering inert, isolation (i.e., physical disconnect, double block and bleed, etc.) and periodic monitoring. Recommendation 2: The using organization should develop a process to periodically monitor hazardous systems for proper configuration (i.e., a daily/weekly/monthly check sheet to verify critical purges are active).

Hester, Zena M.↗

Processing and Liquefaction of NG and Storage of LNG

This Unit Process includes the Pipeline gas input, energy requirements, emissions, losses, and boil-off gas associated with Processing, Liquefaction and Storage of Natural Gas before it is exported.

03 NATURAL GAS↗

Petabyte Class Storage at Jefferson Lab (CEBAF)

By 1997, the Thomas Jefferson National Accelerator Facility will collect over one Terabyte of raw information per day of Accelerator operation from three concurrently operating Experimental Halls. When post-processing is included, roughly 250 TB of raw and formatted experimental data will be generated each year. By the year 2000, a total of one Petabyte will be stored on-line. Critical to the experimental program at Jefferson Lab (JLab) is the networking and computational capability to collect, store, retrieve, and reconstruct data on this scale. The design criteria include support of a raw data stream of 10-12 MB/second from Experimental Hall B, which will operate the CEBAF (Continuous Electron Beam Accelerator Facility) Large Acceptance Spectrometer (CLAS). Keeping up with this data stream implies design strategies that provide storage guarantees during accelerator operation, minimize the number of times data is buffered allow seamless access to specific data sets for the researcher, synchronize data retrievals with the scheduling of postprocessing calculations on the data reconstruction CPU farms, as well as support the site capability to perform data reconstruction and reduction at the same overall rate at which new data is being collected. The current implementation employs state-of-the-art StorageTek Redwood tape drives and robotics library integrated with the Open Storage Manager (OSM) Hierarchical Storage Management software (Computer Associates, International), the use of Fibre Channel RAID disks dual-ported between Sun Microsystems SMP servers, and a network-based interface to a 10,000 SPECint92 data processing CPU farm. Issues of efficiency, scalability, and manageability will become critical to meet the year 2000 requirements for a Petabyte of near-line storage interfaced to over 30,000 SPECint92 of data processing power.

Chambers, Rita↗

Thermal energy storage

The planning and implementation of activities associated with lead center management role and the technical accomplishments pertaining to high temperature thermal energy storage subsystems are described. Major elements reported are: (1) program definition and assessment; (2) research and technology development; (3) industrial storage applications; (4) solar thermal power storage applications; and (5) building heating and cooling applications.

Source record↗

Fate of Listeria monocytogenes Serotypes on Frozen Mixed Vegetables During Consumer‐Simulated Thawing and Storage

ABSTRACT Recent outbreaks and recalls associated with frozen vegetables in the United States and Europe have been linked to Listeria monocytogenes . This study aims to understand the extent to which frozen vegetables support the growth of L. monocytogenes once thawed and held at different temperatures. Six L. monocytogenes strains, two of each from serotypes 1/2a, 1/2b, and 4b, were individually inoculated onto frozen vegetables and stored at −18°C for 7 days. After 7 days, the vegetables were thawed and stored at 5°C or 10°C for up to 14 days or at 25°C for up to 7 days. L. monocytogenes was enumerated from the thawed vegetables throughout the storage period. Population data were fitted to the primary Baranyi model to estimate growth rates and lag phase durations; the secondary Ratkowsky square root model was used to model the relationship of the growth rates with storage temperature. Five of the L. monocytogenes strains survived and grew on the thawed vegetables (population increases of > 1 log CFU/g) stored at 5°C, and all six of the strains proliferated at 10°C and 25°C (population increases of > 3 log CFU/g after 14 days and > 4 log CFU/g after 7 days, respectively). A secondary model was successfully generated based on the growth rates of the six L. monocytogenes strains on the thawed vegetables ( r 2 = 0.8888, RMSE = 0.2057). Results from this study fill a data gap associated with L. monocytogenes survival on thawed vegetables and can be used to determine safe handling and storage practices for these products to protect public health.

Salazar, Joelle K. [Division of Food Processing Sc↗

Sensible heat receiver for solar dynamic space power system

A sensible heat receiver considered in this study uses a vapor grown carbon fiber-carbon (VGCF/C) composite as the thermal storage media and was designed for a 7 kW Brayton engine. The proposed heat receiver stores the required energy to power the system during eclipse in the VGCF/C composite. The heat receiver thermal analysis was conducted through the Systems Improved Numerical Differencing Analyzer and Fluid Integrator (SINDA) software package. The sensible heat receiver compares well with other latent and advanced sensible heat receivers analyzed in other studies while avoiding the problems associated with latent heat storage salts and liquid metal heat pipes. The concept also satisfies the design requirements for a 7 kW Brayton engine system. The weight and size of the system can be optimized by changes in geometry and technology advances for this new material.

Perez-Davis, Marla E.↗

Sensible heat receiver for solar dynamic space power system

A sensible heat receiver is considered which uses a vapor grown carbon fiber-carbon (VGCF/C) composite as the thermal storage medium and which was designed for a 7-kW Brayton engine. This heat receiver stores the required energy to power the system during eclipse in the VGCF/C composite. The heat receiver thermal analysis was conducted through the Systems Improved Numerical Differencing Analyzer and Fluid Integrator (SINDA) software package. The sensible heat receiver compares well with other latent and advanced sensible heat receivers analyzed in other studies, while avoiding the problems associated with latent heat storage salts and liquid metal heat pipes. The concept also satisfies the design requirements for a 7-kW Brayton engine system. The weight and size of the system can be optimized by changes in geometry and technology advances for this new material.

Perez-Davis, Marla E.↗

North Dakota CarbonSAFE - A Success Story

Conference presentation at American Institute of Chemical Engineers (AIChE) Annual Meeting, Phoenix, AZ, November 13–18, 2022. The EERC and the project team leveraged North Dakota’s Class VI primacy status to prepare and submit successful applications for two storage facility permits and associated monitoring and UIC Class VI injection wells. The applications and their supporting documents were prepared in accordance with the North Dakota Century Code and the North Dakota Administrative Code and show the effectiveness of working with a state that has been granted Class VI primacy.

20 FOSSIL-FUELED POWER PLANTS↗

Aboveground carbon loss associated with the spread of ghost forests as sea levels rise

Coastal forests sequester and store more carbon than their terrestrial counterparts but are at greater risk of conversion due to sea level rise. Saltwater intrusion from sea level rise converts freshwater-dependent coastal forests to more salt-tolerant marshes, leaving 'ghost forests' of standing dead trees behind. Although recent research has investigated the drivers and rates of coastal forest decline, the associated changes in carbon storage across large extents have not been quantified. We mapped ghost forest spread across coastal North Carolina, USA, using repeat Light Detection and Ranging (LiDAR) surveys, multi-temporal satellite imagery, and field measurements of aboveground biomass to quantify changes in aboveground carbon. Between 2001 and 2014, 15% (167 km2) of unmanaged public land in the region changed from coastal forest to transition-ghost forest characterized by salt-tolerant shrubs and herbaceous plants. Salinity and proximity to the estuarine shoreline were significant drivers of these changes. This conversion resulted in a net aboveground carbon decline of 0.13 ± 0.01 TgC. Because saltwater intrusion precedes inundation and influences vegetation condition in advance of mature tree mortality, we suggest that aboveground carbon declines can be used to detect the leading edge of sea level rise. Aboveground carbon declines along the shoreline were offset by inland aboveground carbon gains associated with natural succession and forestry activities like planting (2.46 ± 0.25 TgC net aboveground carbon across study area). Our study highlights the combined effects of saltwater intrusion and land use on aboveground carbon dynamics of temperate coastal forests in North America. By quantifying the effects of multiple interacting disturbances, our measurement and mapping methods should be applicable to other coastal landscapes experiencing saltwater intrusion. As sea level rise increases the landward extent of inundation and saltwater exposure, investigations at these large scales are requisite for effective resource allocation for climate adaptation. In this changing environment, human intervention, whether through land preservation, restoration, or reforestation, may be necessary to prevent aboveground carbon loss.

ghost forests↗