Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Apertures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Notes on Synthetic Aperture Radar Image Quality

Synthetic Aperture Radar (SAR) creates an image of a target scene by coherently processing radar echo returns collected along a flightpath. The quality of the SAR image is inextricably linked to the utility of the image for exploitation supporting the task at hand. Aspects of quality include the fidelity with which it can render the scene being imaged, to include the system’s Impulse Response (IPR) and underlying noise levels/characteristics. Other factors also impact utility.

47 OTHER INSTRUMENTATION↗

Optimization of a 123 mm Aperture Nb3Sn Dipole Coil with Stress Management

A 123 mm aperture Nb3Sn cos-theta (CT) dipole coil with stress management (SM) was developed at Fermilab to demonstrate and test the SM concept. Additive Manufacturing technology was used to produce the coil mandrel. Several changes were made to the SMCT coil design and technology based on the analysis of post-production and two cold tests of the first SMCT coil. This article describes the differences in coil design, fabrication steps, and final parameters of the second SMCT coil and its components.

Novitski, Igor [Fermilab]↗

Dynamic Aperture Studies at the Fermilab Recycler Ring

As part of the Proton Improvement Plan II (PIP-II), Fermilab aims to increase beam intensity delivered to neutrino experiments. In this context, higher intensity injection into the Recycler Ring enhances space charge effects, pushing operations closer to third-order resonances. These resonances reduce the Dynamic Aperture (DA), leading to increased beam loss. This study presents simulations of DA as a function of tune in the Recycler Ring, incorporating chaos indicators such as the Reversibility Error Method (REM). The effectiveness of existing resonance mitigation strategies is evaluated by quantifying their ability to delay DA degradation. Additionally, the study examines how space charge detuning and DA limitations dictate viable operational tune points for the Recycler Ring.

Gonzalez-Ortiz, Cristhian Eduardo [Fermilab]↗

Proliferated Resilient Economical Half-Meter Aperture Space Telescopes (PREEMPT)

The PREEMPT LDRD was motivated by a major national need for better space-based imaging systems that are both high performing and affordable for the US Government. Current optical payloads for intelligence, surveillance and reconnaissance (ISR) and space domain awareness (SDA) missions can cost hundreds of millions of dollars and take years to develop, which makes it difficult to build the large constellations required for persistent, world-wide coverage. To address this, the team aimed to advance a different kind of large-aperture (>25 cm) telescope, called a monolithic telescope, in which key optical surfaces are built into a single piece of fused silica. This design greatly reduces payload and spacecraft complexity, the need for precision focus actuators, improves mechanical and thermal robustness, and lowers cost when compared with traditional Cassegrain telescopes that rely on many precisely aligned components. The project focused on five primary thrusts. The first thrust was to advance the concept of a V10, 25 cm, monolithic telescope forward from optical design to flight-ready stage. This was accomplished in partnership with Optimax, who delivered the first test unit in the early stages of the LDRD. The team developed several technologies necessary for this optic to be integrated into a flight demonstration. These include carbon fiber housings, highly detailed structural and thermal models and stress-reducing elastic averaging Hirth groove designs. These technologies resulted in a successful maturation of the optic, which is now slated to fly in late 2026/early 2027 for a demonstration mission. The second thrust was to advance the manufacturability of these optics. In collaboration with NIF’s optical manufacturing shop, we reduced polishing time from 480 hours to 65 hours through the implementation of optimized processes and new tools. The NIF team utilized a conceptual V8 (18 cm) optic to demonstrate this optimization, though it can be applied to the rest of the monolithic optic portfolio. Third, the team developed the first conceptual V20 (50 cm) payload, which is slated to be the next generation of LLNL optical payload systems. A set of structural, dynamic and thermal simulations were performed to identify potential challenges in the future development of this payload. Early-stage simulations suggest the payload is feasible, though thermal management will be the key focus area to maintain optimal performance. Fourth, a non-linear model of Viton was developed, to further enhance the reliability of our structural and dynamic models for future payloads. Viton acts as the primary interface material between the optic and its housing. Lastly, the team focused on successfully displaying the feasibility of using additively manufactured metal composites for optical space payloads. The team successfully demonstrated layer by layer deposition of Al-SiC composites, which have highly tunable structural and coefficient of thermal expansion (CTE) properties. These are crucial for optical payloads because CTE mismatch is one of the causes for degraded optical performance for telescopes in orbit. Overall, the work showed that monolithic telescopes could become a practical, lower-cost path to high-resolution space imaging for both national security and scientific missions.

42 ENGINEERING↗

Factors Controlling a Synthetic Aperture Radar (SAR) Derived Root-Zone Soil Moisture Product over The Seward Peninsula of Alaska

Root-zone soil moisture exerts a fundamental control on vegetation, energy balance, and the carbon cycle in Arctic ecosystems, but it is still not well understood in vast, remote, and understudied regions of discontinuous permafrost. The root-zone soil moisture product (30 m resolution) used in this analysis was retrieved from a time-series P-Band (420–440 MHz) synthetic aperture radar (SAR) backscatter observations (August 2017 & October 2017). While similar approaches have been taken to retrieve surface (0 cm to 5 cm) soil moisture from L-Band (1.2 GHz) SAR backscatter, this is one of the first known attempts at reaching the root-zone in permafrost regions. Here, we analyze secondary factors (excluding primary factors, such as precipitation) controlling summer (August) soil moisture at depths of 6 cm, 12 cm, and 20 cm over a 4500 km2 area on the Seward Peninsula of Alaska. Using a random forest model, we quantify the impact of topography, vegetation, and meteorological factors on soil moisture distributions. In developing the random forest model, we explore a variety of feature scales (30 m, 60 m, 90 m, 120 m, 180 m, and 240 m), tune hyperparameters (the structure of individual decision trees making up the ensemble including the number and depth of trees), and perform the final feature selection using cross-validated recursive feature elimination. Results suggest that root-zone soil moisture on the Seward Peninsula is primarily controlled by vegetation at 6 cm, but deeper in the soil column topography and meteorological factors, such as predominant winter wind direction and summer insolation, play a larger role. The random forest model accounts for 40% to 60% of the variation observed (R2 = 0.44 at 6 cm, R2 = 0.52 at 12 cm, R2 = 0.58 at 20 cm). These results indicate that vegetation is the dominant control on soil moisture shallow in the soil column, but the impact of vegetation does not extend to deeper layers retrieved from P-Band SAR backscatter.

Dann, Julian↗

The Simons Observatory: Beam Characterization for the Small Aperture Telescopes

Abstract We use time-domain simulations of Jupiter observations to test and develop a beam reconstruction pipeline for the Simons Observatory Small Aperture Telescopes. The method relies on a mapmaker that estimates and subtracts correlated atmospheric noise and a beam fitting code designed to compensate for the bias caused by the mapmaker. We test our reconstruction performance for four different frequency bands against various algorithmic parameters, atmospheric conditions, and input beams. We additionally show the reconstruction quality as a function of the number of available observations and investigate how different calibration strategies affect the beam uncertainty. For all of the cases considered, we find good agreement between the fitted results and the input beam model within an ∼1.5% error for a multipole range ℓ = 30–700 and an ∼0.5% error for a multipole range ℓ = 50–200. We conclude by using a harmonic-domain component separation algorithm to verify that the beam reconstruction errors and biases observed in our analysis do not significantly bias the Simons Observatory r -measurement

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DMTN-190: Consistent galaxy colors with Gaussian-Aperture and PSF photometry

Gaussian-Aperture and PSF photometry algorithm measures consistent colors for extended sources such as galaxies that are largely independent of seeing. This technote briefly presents the mathematical description of the algorithm and focuses on its implementation in the Rubin Science Pipelines. This document also serves as a reference for several of the analytical calculations that are tested in the unit tests.

79 ASTRONOMY AND ASTROPHYSICS↗

Apparatus, system and method for highlighting activity-induced change in multi-pass synthetic aperture radar imagery

Described herein are various technologies relating to constructing a differenced change product (DCP) image. A plurality of synthetic aperture radar (SAR) images of a scene are generated based upon radar signals directed towards and reflected off of the scene, and a plurality of coherence change detection (CCD) images of the scene are generated based upon the SAR images. The CCD images are registered with one another, and their pixel values re-scaled according to a monotonic mapping function. The DCP image is generated based upon a computed pixel-wise difference between a pair of the re-scaled CCD images. The DCP image identifies locations in the scene where human activity-induced change is likely to have occurred between a pair of SAR passes of the scene.

42 ENGINEERING↗

The Simons Observatory: Modeling Optical Systematics in the Large Aperture Telescope

We present geometrical and physical optics simulation results for the Simons Observatory Large Aperture Telescope. This work was developed as part of the general design process for the telescope; allowing us to evaluate the impact of various design choices on performance metrics and potential systematic effects. The primary goal of the simulations was to evaluate the final design of the reflectors and the cold optics which are now being built. We describe non-sequential ray tracing used to inform the design of the cold optics, including absorbers internal to each optics tube. We discuss ray tracing simulations of the telescope structure that allow us to determine geometries that minimize detector loading and mitigate spurious near-field effects that have not been resolved by the internal baffling. We also describe physical optics simulations, performed over a range of frequencies and field locations, that produce estimates of monochromatic far field beam patterns which in turn are used to gauge general optical performance. Finally, we describe simulations that shed light on beam sidelobes from panel gap diffraction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A full-ring variable-aperture cadmium zinc telluride system for whole-body single photon emission computed tomography: realistic simulations with phantoms

Single photon emission computed tomography (SPECT) is an imaging modality that has demonstrated its utility in a number of clinical indications. Despite this progress, a high sensitivity, high spatial resolution, multi-tracer SPECT with a large field of view suitable for whole-body imaging of a broad range of radiotracers for theranostics is not available. Purpose We have designed a cadmium zinc telluride (CZT) variable-aperture full-ring SPECT scanner instrumented with a broad-energy tungsten collimator intended to fill this technological gap. The final purpose is to provide a multi-tracer solution for brain and whole-body imaging. Our static SPECT scanner breaks the paradigm of the standard dual- and triple-head rotational SPECT systems, utilizing a larger detector area in each scan increasing the sensitivity. We provide a demonstration of the performance of our design using a realistic model of our detector with simulated body-sized 99mTc phantoms. Methods We developed a realistic model of our detector by using a combination of a Geant4 Monte Carlo simulation and a CZT detector response model based on a finite element model. Our approach models the characteristic low-energy tail effect in CZT that noticeably affects the sensitivity and the quality of the scatter correction in CZT detectors. We implement a modified dual energy window scatter correction adapted to include the CZT low-energy tail effect. A dedicated correction is also developed to eliminate the undesirable truncation observed in images given the presence of detector edges and gaps between detectors, due to the non-rotational nature of our device. Corrections for the attenuation, detector response and the presence of collimators are also included. The images are reconstructed using the maximum-likelihood expectation-maximization algorithm implemented in the reconstruction open software STIR. Detector and reconstruction performance are characterized with a Derenzo phantom and a body-sized National Electrical Manufacturers Association (NEMA) Image Quality (IQ) phantom containing 99mTc. Results Our SPECT design can resolve 6.4mm rods in a Derenzo phantom and obtain a good image contrast with the IQ phantom. Explicit testing of the gap and edge correction is provided, showing an excellent performance in eliminating the image truncation artifacts. Our modified scatter correction shows no overestimation of the contrast-recovery ratio for our realistic CZT detector model, as opposed to the cases without correction and with a standard dual-energy window scatter correction. Conclusions In this paper, we further demonstrate the performance of our design for whole-body imaging purposes. This adds to our previous demonstration of improved qualitative and quantitative 99mTc imaging for brain perfusion and 123I imaging for dopamine transport with respect to state-of-the-art NaI dual-head cameras. We show that our design performs similarly to the VERITON SPECT from Spectrum Dynamics, a commercial full-ring CZT SPECT camera, with the potential advantage of the broader energy range of application given by our custom-design tungsten collimators. Here, our device combines high sensitivity and image resolution with a broad-energy imaging application for the purpose of clinical imaging and theranostics of emerging radionuclides.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantitative Holdup Determinations Using Coded-Aperture Gamma-Ray Imaging

Passive gamma-ray imaging can be used to create images of distributed nuclear materials. Inherently quantitative, the images provide a means to directly determine the amount of nuclear material in the imager’s field of view. However, to take advantage of quantitative imaging, one must correct for changes to the imager’s efficiency across the image. This paper presents work on detailed calibration of a coded-aperture imager based on a portable, mechanically cooled, high-purity germanium detector. This enables the use of gamma-ray imaging as a tool to determine nuclear holdup. By applying the calibrations to images of small amounts of distributed 235U, quantity estimates within a few percent of the actual amounts present were obtained, validating the approach.

Ziock, Klaus-Peter↗

Overview of the Optical Design of the CMB-S4 Large Aperture Telescopes and Camera Optics

CMB-S4, the next-generation CMB observatory, will deploy hundreds of thousands of detectors to enable mapping the millimeter-wavelength sky with unprecedented speed. The large aperture telescopes for CMB-S4 consist of six-meter diameter crossed Dragone designs and a five-meter diameter three-mirror anastigmat. The two-mirror crossed Dragone design requires astigmatism corrections in the refractive optics to achieve diffraction-limited performance. We present biconic lens corrections for the CMB-S4 crossed Dragone camera optics and compare these designs to the camera optics for the three mirror anastigmat, as the optical designs of the cameras for these telescopes are being prototyped.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detailed Characterization of CZT Detector Response for Improved Coded-Aperture Imaging Performance

Gamma-ray imaging is a powerful method for locating and quantifying sources of radiation. The coded-aperture technique demonstrates superior angular resolution in comparison to other methods (e.g., Compton reconstruction). In this method, a mask constructed of highly attenuating material encodes the scene as a shadow pattern on a position-sensitive detector; this pattern can then be used to recreate the origin(s) of incident radiation. This is typically done through convolution of the mask and shadow patterns. Iterative methods which attempt to reconstruct the observed shadow pattern using a weighted combination of simulated patterns may also be employed. In either case, errors in event position reconstruction due to detector imperfections alter the shadow pattern and will therefore degrade system performance and may introduce imaging artifacts. These effects can be mitigated with a detailed understanding of such errors – allowing for the generation of representative simulations that include the errors and/or correction of raw imager data to remove the errors. We present a calibration process for a commercially available cadmium zinc telluride (CZT) gamma imager which provides a comprehensive characterization of the spatial and energy dependence of event reconstruction. By illuminating a mask featuring a regular grid of pinholes with a calibration source, the localized response of the detector can be measured with fine granularity. These local responses are combined to generate a full detector response map which can be used to distort simulations in a manner that is representative of the observed detector data. Details of the calibration procedure and an assessment of the impact of its end products on the performance of iterative imaging methods will be presented.

Ziock, Klaus-Peter↗

Whole-scene, one-sided backscatter x-ray imaging with coded apertures

X-ray radiography can be an important diagnostic for emergency response, providing timely diagnostic information about a suspect object. However, there are situations where similar information would be better obtained with a one-sided imaging technique. X-ray backscatter imaging is a proven technology that could provide such information, but current implementations have drawbacks that render it unsuitable for emergency response. We are exploring the use of coded-aperture imaging to create one-sided images, targeting a key benefit: implementation requiring minimal additional resources, bypassing logistics issues. We present results demonstrating the feasibility of this approach.

Ziock, Klaus-Peter [ORNL]↗

Large aperture and durable glass-engraved optical metasurfaces using nanoparticle etching masks: prospects and future directions

Abstract Metasurfaces (MSs), or surfaces consisting of engineered spatially oriented sub-wavelength elements—also known as meta-atoms—are quickly becoming a burgeoning field of interest due to their seemingly unparalleled control over the propagation of light. This article will discuss the emergence of a MS technology that is based on dewetting thin metal films to form dry etching masks for MS fabrication. The novelty this process presents is the ability to spatially vary mask features—which translates into spatially varying index of the finished surface—in a way that, rather than writing subwavelength elements one-by-one, writes entire areas at once to provide a route to easily scale the process up to meter-sized optics. Glass-engraved MSs have shown to be laser damage resistant, with damage thresholds close to the parent substrate damage thresholds. Furthermore, these surfaces have proven to be mechanically durable and capable of handling normal loads two orders of magnitude higher than that of an average fingerprint pressure. This indicates that accidental handling contact is not detrimental to the MS optical performance. Also discussed are the foreseeable technological challenges, potential solutions for those obstacles, and some currently unexplored directions for future efforts.

47 OTHER INSTRUMENTATION↗

Design of B1pF-A Large Aperture Dipole Magnet for EIC

The design of interaction region (IR) magnets for the Electron Ion Collider (EIC), demands tight boundary conditions on the magnet design given by the high field requirements and the proximity of electron and hadron beams within a common yoke and resultant crosstalk. Here, this article discusses the electromagnetic design of the superconducting collared magnet B1pF. The magnet will be built as the prototype for several collared magnets (dipoles and quadrupoles) for the hadron beam in the forward direction of the IR. The magnet design is based on a single layer coil with an inner diameter of 300 mm over a slot length of 3 m. The magnet produces an integral field of 10.34 T.m at a current of 11.9 kA to produce a nominal field of about 3.96 T at its center. Given by the common Rutherford cable parameters, the magnet will be used as a baseline for optimization of all the collared magnets. The article further discusses yoke optimizations, quench analysis, coil end design and efforts on fine tuning of field quality.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗