Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Anonymization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

SU-C-213-01: 3D Printed Patient Specific Phantom Composed of Bone and Soft Tissue Substitute Plastics for Radiation Therapy

Purpose: 3D printed phantoms constructed of multiple tissue approximating materials could be useful in both clinical and research aspects of radiotherapy. This work describes a 3D printed phantom constructed with tissue substitute plastics for both bone and soft tissue; air cavities were included as well. Methods: 3D models of an anonymized nasopharynx patient were generated for air cavities, soft tissues, and bone, which were segmented by Hounsfield Unit (HU) thresholds. HU thresholds were chosen to define air-to-soft tissue boundaries of 0.65 g/cc and soft tissue-to-bone boundaries of 1.18 g/cc based on clinical HU to density tables. After evaluation of several composite plastics, a bone tissue substitute was identified as an acceptable material for typical radiotherapy x-ray energies, composed of iron and PLA plastic. PET plastic was determined to be an acceptable soft tissue substitute. 3D printing was performed on a consumer grade dual extrusion fused deposition model 3D printer. Results: MVCT scans of the 3D printed heterogeneous phantom were acquired. Rigid image registration of the patient and the 3D printed phantom scans was performed. The average physical density of the soft tissue and bone regions was 1.02 ± 0.08 g/cc and 1.39 ± 0.14 g/cc, respectively, for the patient kVCT scan. In the 3D printed phantom MVCT scan, the average density of the soft tissue and bone was 1.01 ± 0.09 g/cc and 1.44 ± 0.12 g/cc, respectively. Conclusion: A patient specific phantom, constructed of heterogeneous tissue substitute materials was constructed by 3D printing. MVCT of the 3D printed phantom showed realistic tissue densities were recreated by the 3D printing materials. Funding provided by intra-department grant by University of Minnesota Department of Radiation Oncology.

60 APPLIED LIFE SCIENCES↗

SU-E-J-251: Incorporation of Pre-Therapy 18F-FDG Uptake with CT Texture Features in a Predictive Model for Radiation Pneumonitis Development

Purpose: To determine whether the addition of standardized uptake value (SUV) statistical variables to CT lung texture features can improve a predictive model of radiation pneumonitis (RP) development in patients undergoing radiation therapy. Methods: Anonymized data from 96 esophageal cancer patients (18 RP-positive cases of Grade ≥ 2) were retrospectively collected including pre-therapy PET/CT scans, pre-/posttherapy diagnostic CT scans and RP status. Twenty texture features (firstorder, fractal, Laws’ filter and gray-level co-occurrence matrix) were calculated from diagnostic CT scans and compared in anatomically matched regions of the lung. The mean, maximum, standard deviation, and 50th–95th percentiles of the SUV values for all lung voxels in the corresponding PET scans were acquired. For each texture feature, a logistic regression-based classifier consisting of (1) the average change in that texture feature value between the pre- and post-therapy CT scans and (2) the pre-therapy SUV standard deviation (SUV{sub SD}) was created. The RP-classification performance of each logistic regression model was compared to the performance of its texture feature alone by computing areas under the receiver operating characteristic curves (AUCs). T-tests were performed to determine whether the mean AUC across texture features changed significantly when SUV{sub SD} was added to the classifier. Results: The AUC for single-texturefeature classifiers ranged from 0.58–0.81 in high-dose (≥ 30 Gy) regions of the lungs and from 0.53–0.71 in low-dose (< 10 Gy) regions. Adding SUVSD in a logistic regression model using a 50/50 data partition for training and testing significantly increased the mean AUC by 0.08, 0.06 and 0.04 in the low-, medium- and high-dose regions, respectively. Conclusion: Addition of SUVSD from a pre-therapy PET scan to a single CT-based texture feature improves RP-classification performance on average. These findings demonstrate the potential for more accurate prediction of RP using information from multiple imaging modalities. Supported, in part, by the National Institute of Biomedical Imaging and Bioengineering of the National Institutes of Health under grant number T32 EB002103; SGA receives royalties and licensing fees through the University of Chicago for computer-aided diagnosis technology. HA receives royalties through the University of Chicago for computer-aided diagnosis technology.

60 APPLIED LIFE SCIENCES↗

SU-E-T-622: Planning Technique for Passively-Scattered Involved-Node Proton Therapy of Mediastinal Lymphoma with Consideration of Cardiac Motion

Purpose: To develop a treatment planning method for passively-scattered involved-node proton therapy of mediastinal lymphoma robust to breathing and cardiac motions. Methods: Beam-specific planning treatment volumes (bsPTV) are calculated for each proton field to incorporate pertinent uncertainties. Geometric margins are added laterally to each beam while margins for range uncertainty due to setup errors, breathing, and calibration curve uncertainties are added along each beam. The calculation of breathing motion and deformation effects on proton range includes all 4DCT phases. The anisotropic water equivalent margins are translated to distances on average 4DCT. Treatment plans are designed so each beam adequately covers the corresponding bsPTV. For targets close to the heart, cardiac motion effects on dosemaps are estimated by using a library of anonymous ECG-gated cardiac CTs (cCT). The cCT, originally contrast-enhanced, are partially overridden to allow meaningful proton dose calculations. Targets similar to the treatment targets are drawn on one or more cCT sets matching the anatomy of the patient. Plans based on the average cCT are calculated on individual phases, then deformed to the average and accumulated. When clinically significant dose discrepancies occur between planned and accumulated doses, the patient plan is modified to reduce the cardiac motion effects. Results: We found that bsPTVs as planning targets create dose distributions similar to the conventional proton planning distributions, while they are a valuable tool for visualization of the uncertainties. For large targets with variability in motion and depth, integral dose was reduced because of the anisotropic margins. In most cases, heart motion has a clinically insignificant effect on target coverage. Conclusion: A treatment planning method was developed and used for proton therapy of mediastinal lymphoma. The technique incorporates bsPTVs compensating for all common sources of uncertainties and estimation of the effects of cardiac motion not commonly performed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-CD-304-11: Veritas 2.0: A Cloud-Based Tool to Facilitate Research and Innovation

Purpose: We introduce Veritas 2.0, a cloud-based, non-clinical research portal, to facilitate translation of radiotherapy research ideas to new delivery techniques. The ecosystem of research tools includes web apps for a research beam builder for TrueBeam Developer Mode, an image reader for compressed and uncompressed XIM files, and a trajectory log file based QA/beam delivery analyzer. Methods: The research beam builder can generate TrueBeam readable XML file either from scratch or from pre-existing DICOM-RT plans. DICOM-RT plan is first converted to XML format and then researcher can interactively modify or add control points to them. Delivered beam can be verified via reading generated images and analyzing trajectory log files. Image reader can read both uncompressed and HND-compressed XIM images. The trajectory log analyzer lets researchers plot expected vs. actual values and deviations among 30 mechanical axes. The analyzer gives an animated view of MLC patterns for the beam delivery. Veritas 2.0 is freely available and its advantages versus standalone software are i) No software installation or maintenance needed, ii) easy accessibility across all devices iii) seamless upgrades and iv) OS independence. Veritas is written using open-source tools like twitter bootstrap, jQuery, flask, and Python-based modules. Results: In the first experiment, an anonymized 7-beam DICOM-RT IMRT plan was converted to XML beam containing 1400 control points. kV and MV imaging points were inserted into this XML beam. In another experiment, a binary log file was analyzed to compare actual vs expected values and deviations among axes. Conclusions: Veritas 2.0 is a public cloud-based web app that hosts a pool of research tools for facilitating research from conceptualization to verification. It is aimed at providing a platform for facilitating research and collaboration. I am full time employee at Varian Medical systems, Palo Alto.

60 APPLIED LIFE SCIENCES↗

WE-G-BRA-01: Patient Safety and Treatment Quality Improvement Through Incident Learning: Experience of a Non-Academic Proton Therapy Center

Purpose: Incident learning has been proven to improve patient safety and treatment quality in conventional radiation therapy. However, its application in proton therapy has not been reported yet to our knowledge. In this study, we report our experience in developing and implementation of an in-house incident learning system. Methods: An incident learning system was developed based on published principles and tailored for our clinical practice and available resource about 18 months ago. The system includes four layers of error detection and report: 1) dosimetry peer review; 2) physicist plan quality assurance (QA); 3) treatment delivery issue on call and record; and 4) other incident report. The first two layers of QA and report were mandatory for each treatment plan through easy-to-use spreadsheets that are only accessible by the dosimetry and physicist departments. The treatment delivery issues were recorded case by case by the on call physicist. All other incidents were reported through an online incident report system, which can be anonymous. The incident report includes near misses on planning and delivery, process deviation, machine issues, work flow and documentation. Periodic incident reviews were performed. Results: In total, about 116 errors were reported through dosimetry review, 137 errors through plan QA, 83 treatment issues through physics on call record, and 30 through the online incident report. Only 8 incidents (2.2%) were considered to have a clinical impact to patients, and the rest of errors were either detected before reaching patients or had negligible dosimetric impact (<5% dose variance). Personnel training & process improvements were implemented upon periodic incident review. Conclusion: An incident learning system can be helpful in personnel training, error reduction, and patient safety and treatment quality improvement. The system needs to be catered for each clinic’s practice and available resources. Incident and knowledge sharing among proton centers are encouraged.

60 APPLIED LIFE SCIENCES↗

WE-G-204-09: Medical Physics 2.0 in Practice: Automated QC Assessment of Clinical Chest Images

Purpose: To determine whether a proposed suite of objective image quality metrics for digital chest radiographs is useful for monitoring image quality in our clinical operation. Methods: Seventeen gridless AP Chest radiographs from a GE Optima portable digital radiography (DR) unit (Group 1), seventeen (routine) PA Chest radiographs from a GE Discovery DR unit (Group 2), and sixteen gridless (non-routine) PA Chest radiographs from the same Discovery DR unit (Group 3) were chosen for analysis. Groups were selected to represent “sub-standard” (Group 1), “standard-of-care” (Group 2), and images with a gross technical error (Group 3). Group 1 images were acquired with lower kVp (90 vs. 125), shorter source-to-image distance (127cm vs 183cm) and were expected to have lower quality than images in Group 2. Group 3 was expected to have degraded contrast versus Group 2.This evaluation was approved by the institutional Quality Improvement Assurance Board (QIAB). Images were anonymized and securely transferred to the Duke University Clinical Imaging Physics Group for analysis using software previously described{sup 1} and validated{sup 2}. Image quality for individual images was reported in terms of lung grey level(Lgl); lung noise(Ln); rib-lung contrast(RLc); rib sharpness(Rs); mediastinum detail(Md), noise(Mn), and alignment(Ma); subdiaphragm-lung contrast(SLc); and subdiaphragm area(Sa). Metrics were compared across groups. Results: Metrics agreed with published Quality Consistency Ranges with three exceptions: higher Lgl, lower RLc, and SDc. Higher bit depth (16 vs 12) accounted for higher Lgl values in our images. Values were most internally consistent for Group 2. The most sensitive metric for distinguishing between groups was Mn followed closely by Ln. The least sensitive metrics were Md and RLc. Conclusion: The software appears promising for objectively and automatically identifying substandard images in our operation. The results can be used to establish local quality consistency ranges and action limits per facility preferences.

60 APPLIED LIFE SCIENCES↗

Upper limits of the photon fluence rate on CT detectors: Case study on a commercial scanner

Purpose: The highest photon fluence rate that a computed tomography (CT) detector must be able to measure is an important parameter. The authors calculate the maximum transmitted fluence rate in a commercial CT scanner as a function of patient size for standard head, chest, and abdomen protocols. Methods: The authors scanned an anthropomorphic phantom (Kyoto Kagaku PBU-60) with the reference CT protocols provided by AAPM on a GE LightSpeed VCT scanner and noted the tube current applied with the tube current modulation (TCM) system. By rescaling this tube current using published measurements on the tube current modulation of a GE scanner [N. Keat, “CT scanner automatic exposure control systems,” MHRA Evaluation Report 05016, ImPACT, London, UK, 2005], the authors could estimate the tube current that these protocols would have resulted in for other patient sizes. An ECG gated chest protocol was also simulated. Using measured dose rate profiles along the bowtie filters, the authors simulated imaging of anonymized patient images with a range of sizes on a GE VCT scanner and calculated the maximum transmitted fluence rate. In addition, the 99th and the 95th percentiles of the transmitted fluence rate distribution behind the patient are calculated and the effect of omitting projection lines passing just below the skin line is investigated. Results: The highest transmitted fluence rates on the detector for the AAPM reference protocols with centered patients are found for head images and for intermediate-sized chest images, both with a maximum of 3.4 ⋅ 10{sup 8} mm{sup −2} s{sup −1}, at 949 mm distance from the source. Miscentering the head by 50 mm downward increases the maximum transmitted fluence rate to 5.7 ⋅ 10{sup 8} mm{sup −2} s{sup −1}. The ECG gated chest protocol gives fluence rates up to 2.3 ⋅ 10{sup 8} − 3.6 ⋅ 10{sup 8} mm{sup −2} s{sup −1} depending on miscentering. Conclusions: The fluence rate on a CT detector reaches 3 ⋅ 10{sup 8} − 6 ⋅ 10{sup 8} mm{sup −2} s{sup −1} in standard imaging protocols, with the highest rates occurring for ECG gated chest and miscentered head scans. These results will be useful to developers of CT detectors, in particular photon counting detectors.

60 APPLIED LIFE SCIENCES↗

SU-C-207B-05: Tissue Segmentation of Computed Tomography Images Using a Random Forest Algorithm: A Feasibility Study

Purpose: Develop an automated Random Forest algorithm for tissue segmentation of CT examinations. Methods: Seven materials were classified for segmentation: background, lung/internal gas, fat, muscle, solid organ parenchyma, blood/contrast, and bone using Matlab and the Trainable Weka Segmentation (TWS) plugin of FIJI. The following classifier feature filters of TWS were investigated: minimum, maximum, mean, and variance each evaluated over a pixel radius of 2n, (n = 0–4). Also noise reduction and edge preserving filters, Gaussian, bilateral, Kuwahara, and anisotropic diffusion, were evaluated. The algorithm used 200 trees with 2 features per node. A training data set was established using an anonymized patient’s (male, 20 yr, 72 kg) chest-abdomen-pelvis CT examination. To establish segmentation ground truth, the training data were manually segmented using Eclipse planning software, and an intra-observer reproducibility test was conducted. Six additional patient data sets were segmented based on classifier data generated from the training data. Accuracy of segmentation was determined by calculating the Dice similarity coefficient (DSC) between manual and auto segmented images. Results: The optimized autosegmentation algorithm resulted in 16 features calculated using maximum, mean, variance, and Gaussian blur filters with kernel radii of 1, 2, and 4 pixels, in addition to the original CT number, and Kuwahara filter (linear kernel of 19 pixels). Ground truth had a DSC of 0.94 (range: 0.90–0.99) for adult and 0.92 (range: 0.85–0.99) for pediatric data sets across all seven segmentation classes. The automated algorithm produced segmentation with an average DSC of 0.85 ± 0.04 (range: 0.81–1.00) for the adult patients, and 0.86 ± 0.03 (range: 0.80–0.99) for the pediatric patients. Conclusion: The TWS Random Forest auto-segmentation algorithm was optimized for CT environment, and able to segment seven material classes over a range of body habitus and CT protocol parameters with an average DSC of 0.86 ± 0.04 (range: 0.80–0.99).

60 APPLIED LIFE SCIENCES↗

SU-F-J-84: Comparison of Quantitative Deformable Image Registration Evaluation Tools: Application to Prostate IGART

Purpose: Errors in displacement vector fields (DVFs) generated by Deformable Image Registration (DIR) algorithms can give rise to significant uncertainties in contour propagation and dose accumulation in Image-Guided Adaptive Radiotherapy (IGART). The purpose of this work is to assess the accuracy of two DIR algorithms using a variety of quality metrics for prostate IGART. Methods: Pelvic CT images were selected from an anonymized database of nineteen prostate patients who underwent 8–12 serial scans during radiotherapy. Prostate, bladder, and rectum were contoured on 34 image-sets for three patients by the same physician. The planning CT was deformably-registered to daily CT using three variants of the Small deformation Inverse Consistent Linear Elastic (SICLE) algorithm: Grayscale-driven (G), Contour-driven (C, which utilizes segmented structures to drive DIR), combined (G+C); and also grayscale ITK demons (Gd). The accuracy of G, C, G+C SICLE and Gd registrations were evaluated using a new metric Edge Gradient Distance to Agreement (EGDTA) and other commonly-used metrics such as Pearson Correlation Coefficient (PCC), Dice Similarity Index (DSI) and Hausdorff Distance (HD). Results: C and G+C demonstrated much better performance at organ boundaries, revealing the lowest HD and highest DSI, in prostate, bladder and rectum. G+C demonstrated the lowest mean EGDTA (1.14 mm), which corresponds to highest registration quality, compared to G and C DVFs (1.16 and 2.34 mm). However, demons DIR showed the best overall performance, revealing lowest EGDTA (0.73 mm) and highest PCC (0.85). Conclusion: As expected, both C- and C+G SICLE more accurately reproduce manually-contoured target datasets than G-SICLE or Gd using HD and DSI metrics. In general, the Gd appears to have difficulty reproducing large daily position and shape changes in the rectum and bladder. However, Gd outperforms SICLE in terms of EGDTA and PCC metrics, possibly at the expense of topological quality of the estimated DVFs.

60 APPLIED LIFE SCIENCES↗

SU-F-T-115: Uncertainty in the Esophagus Dose in Retrospective Epidemiological Study of Breast Cancer Radiotherapy Patients

Purpose: Epidemiological studies of second cancer risks in breast cancer radiotherapy patients often use generic patient anatomy to reconstruct normal tissue doses when CT images of patients are not available. To evaluate the uncertainty involved in the dosimetry approach, we evaluated the esophagus dose in five sample patients by simulating breast cancer treatments. Methods: We obtained the diagnostic CT images of five anonymized adult female patients in different Body Mass Index (BMI) categories (16– 36kg/m2) from National Institutes of Health Clinical Center. We contoured the esophagus on the CT images and imported them into a Treatment Planning System (TPS) to create treatment plans and calculate esophagus doses. Esophagus dose was calculated once again via experimentally-validated Monte Carlo (MC) transport code, XVMC under the same geometries. We compared the esophagus doses from TPS and the MC method. We also investigated the degree of variation in the esophagus dose across the five patients and also the relationship between the patient characteristics and the esophagus doses. Results: Eclipse TPS using Analytical Anisotropic Algorithm (AAA) significantly underestimates the esophagus dose in breast cancer radiotherapy compared to MC. In the worst case, the esophagus dose from AAA was only 40% of the MC dose. The Coefficient of Variation across the patients was 48%. We found that the maximum esophagus dose was up to 2.7 times greater than the minimum. We finally observed linear relationship (Dose = 0.0218 × BMI – 0.1, R2=0.54) between patient’s BMI and the esophagus doses. Conclusion: We quantified the degree of uncertainty in the esophagus dose in five sample breast radiotherapy patients. The results of the study underscore the importance of individualized dose reconstruction for the study cohort to avoid misclassification in the risk analysis of second cancer. We are currently extending the number of patients up to 30.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-TeP1-04: Pseudo-In-Vivo Dose Verification of a New Mono-Isocentric Technique for the Treatment of Multiple Brain Metastases

Purpose: To validate dose calculation and delivery accuracy of a recently introduced mono-isocentric technique for the treatment of multiple brain metastases in a realistic clinical case. Methods: Anonymized CT scans of a patient were used to model a hollow phantom that duplicates anatomy of the skull. A 3D printer was used to construct the phantom of a radiologically bone-equivalent material. The hollow phantom was subsequently filled with a polymer gel 3D dosimeter which also acted as a water-equivalent material. Irradiation plan consisted of 5 targets and was identical to the one delivered to the specific patient except for the prescription dose which was optimized to match the gel dose-response characteristics. Dose delivery was performed using a single setup isocenter dynamic conformal arcs technique. Gel dose read-out was carried out by a 1.5 T MRI scanner. All steps of the corresponding patient’s treatment protocol were strictly followed providing an end-to-end quality assurance test. Pseudo-in-vivo measured 3D dose distribution and calculated one were compared in terms of spatial agreement, dose profiles, 3D gamma indices (5%/2mm, 20% dose threshold), DVHs and DVH metrics. Results: MR-identified polymerized areas and calculated high dose regions were found to agree within 1.5 mm for all targets, taking into account all sources of spatial uncertainties involved (i.e., set-up errors, MR-related geometric distortions and registration inaccuracies). Good dosimetric agreement was observed in the vast majority of the examined profiles. 3D gamma index passing rate reached 91%. DVH and corresponding metrics comparison resulted in a satisfying agreement between measured and calculated datasets within targets and selected organs-at-risk. Conclusion: A novel, pseudo-in-vivo QA test was implemented to validate spatial and dosimetric accuracy in treatment of multiple metastases. End-to-end testing demonstrated that our gel dosimetry phantom is suited for such QA procedures, allowing for 3D analysis of both targeting placement and dose.

60 APPLIED LIFE SCIENCES↗

TU-FG-209-07: Medical Physics 1.0 Versus Medical Physics 2.0: A Case Study

Purpose: To illustrate how performance analytics can identify performance decrement in digital radiography systems. Methods: Subsequent to a radiologist’s image quality complaint, four different advanced methods contributed to root cause analysis. Our system was a GE Revolution XQi digital radiography unit. Initially, we reviewed weekly GE Quality Assurance Procedures (QAP) results in a database dating from 2001. Next, we evaluated objective image quality metrics of individual PA Chest radiographs acquired. These images were anonymized, securely transferred, and analyzed by the Duke University Clinical Imaging Physics Group with software previously described{sup 1} and validated{sup 2}. Third, we compared the exposure-dependent SNR{sup 2} (NEQ) of the unit with previously established confidence limits{sup 3}. Finally, we explored our service database to reveal events that might affect detector performance. Results: QAP reported a decrease in CNR reflected in a significant increase in lung noise(Ln), mediastinum noise(Mn), and subdiaphragm-lung contrast(Slc) with a significant decrease in lung grey level(Lgl) after detector replacement. Most change occurred during week 1, before the QAP indicated one-half the ultimate decrease in CNR. After detector recalibration, QAP CNR improved, but was not restored to previous levels. Lgl and Slc were no longer significantly different from before, however Ln and Mn remained significantly different. Exposure-dependent SNR2 show the detector to be operating within limits in October 2006 but subsequently became miscalibrated sometime before acquisition of the 2011–2014 data. Service records revealed catastrophic failure of the Image Detection Controller that contained the 2007 calibration. Traditional metrics did not indicate that the system was performing outside of normal limits. Conclusion: Performance analytics are powerful tools whose proper application could allow early intervention in degraded system performance. The image-quality metrics appear to be highly sensitive to system performance and are reported with every acquisition rather than at arbitrary intervals. Confidence intervals may require customization for individual systems or detectors.

60 APPLIED LIFE SCIENCES↗

Sci-Fri AM: Quality, Safety, and Professional Issues 06: An Evaluation of Incident Reporting and Learning using the Canadian National System for Incident Reporting – Radiation Treatment

We report on the development and clinical deployment of an in-house incident reporting and learning system that implements the taxonomy of the Canadian National System for Incident Reporting – Radiation Treatment (NSIR-RT). In producing our new system, we aimed to: Analyze actual incidents, as well as potentially dangerous latent conditions. Produce recommendations on the NSIR-RT taxonomy. Incorporate features to divide reporting responsibility among clinical staff and expedite incident categorization within the NSIR-RT framework. Share anonymized incident data with the national database. Our multistep incident reporting workflow is focused around an initial report and a detailed follow-up investigation. An investigator, chosen at the time of reporting, is tasked with performing the investigation. The investigation feature is connected to our electronic medical records database to allow automatic field population and quick reference of patient and treatment information. Additional features include a robust visualization suite, as well as the ability to flag incidents for discussion at monthly Risk Management meetings and task ameliorating actions to staff. Our system was deployed into clinical use in January 2016. Over the first three months of use, 45 valid incidents were reported; 31 of which were reported as actual incidents as opposed to near-misses or reportable circumstances. However, we suspect there is ambiguity within our centre in determining the appropriate event type, which may be arising from the taxonomy itself. Preliminary trending analysis aided in revealing workflow issues pertaining to storage of treatment accessories and treatment planning delays. Extensive analysis will be undertaken as more data are accrued.

60 APPLIED LIFE SCIENCES↗

Using AI tools to analyze periodic phenomena

Here, in this report, we describe how students can use natural language to prompt ChatGPT to conduct the analysis of complex periodic acceleration data collected using their smartphones. Students may use this approach to characterize human physiological tremor frequency. Students can choose to use their own data, or, for privacy purposes, use an anonymized set of data provided to them.

Klay, Jennifer L. [California Polytechnic State Un↗

The price of privately releasing contingency tables, and the spectra of random matrices with correlated rows

Contingency tables are the method of choice of government agencies for releasing statistical summaries of categorical data. In this paper, we consider lower bounds on how much distortion (noise) is necessary in these tables to provide privacy guarantees when the data being summarized is sensitive. We extend a line of recent work on lower bounds on noise for private data analysis [10, 13. 14, 15] to a natural and important class of functionalities. Our investigation also leads to new results on the spectra of random matrices with correlated rows. Consider a database D consisting of n rows (one per individual), each row comprising d binary attributes. For any subset of T attributes of size |T| = k, the marginal table for T has 2{sup k} entries; each entry counts how many times in the database a particular setting of these attributes occurs. Imagine an agency that wishes to release all (d/k) contingency tables for a given database. For constant k, previous work showed that distortion {tilde {Omicron}}(min{l_brace}n, (n{sup 2}d){sup 1/3}, {radical}d{sup k}{r_brace}) is sufficient for satisfying differential privacy, a rigorous definition of privacy that has received extensive recent study. Our main contributions are: (1) For {epsilon}- and ({epsilon}, {delta})-differential privacy (with {epsilon} constant and {delta} = 1/poly(n)), we give a lower bound of {tilde {Omega}}(min{l_brace}{radical}n, {radical}d{sup k}{r_brace}), which is tight for n = {tilde {Omega}}(d{sup k}). Moreover, for a natural and popular class of mechanisms based on additive noise, our bound can be strengthened to {Omega}({radical}d{sup k}), which is tight for all n. Our bounds extend even to non-constant k, losing roughly a factor of {radical}2{sup k} compared to the best known upper bounds for large n. (2) We give efficient polynomial time attacks which allow an adversary to reconstruct sensitive infonnation given insufficiently perturbed contingency table releases. For constant k, we obtain a lower bound of {tilde {Omega}}(min{l_brace}{radical}n, {radical}d{sup k}{r_brace}) that applies to a large class of privacy notions, including K-anonymity (along with its variants) and differential privacy. In contrast to our bounds for differential privacy, this bound (a) is shown only for constant k, but (b) is tight for all values of n when k is constant. (3) Our reconstruction-based attacks require a new lower bound on the least singular values of random matrices with correlated rows. For a constant k, consider a matrix M with (d/k) rows which are formed by taking all possible k-way entry-wise products of an underlying set of d random vectors. We show that even for nearly square matrices with d{sup k}/log d columns, the least singular value is {Omega}({radical}d{sup k}) with high probability - asymptotically, the same bound as one gets for a matrix with independent rows. The proof requires several new ideas for analyzing random matrices and could be of independent interest.

97 MATHEMATICS AND COMPUTING↗

Safe and Private Forward-trading Platform for Transactive Microgrids

Power grids are evolving at an unprecedented pace due to the rapid growth of distributed energy resources (DER) in communities. These resources are very different from traditional power sources, as they are located closer to loads and thus can significantly reduce transmission losses and carbon emissions. However, their intermittent and variable nature often results in spikes in the overall demand on distribution system operators (DSO). To manage these challenges, there has been a surge of interest in building decentralized control schemes, where a pool of DERs combined with energy storage devices can exchange energy locally to smooth fluctuations in net demand. Building a decentralized market for transactive microgrids is challenging, because even though a decentralized system provides resilience, it also must satisfy requirements such as privacy, efficiency, safety, and security, which are often in conflict with each other. As such, existing implementations of decentralized markets often focus on resilience and safety but compromise on privacy. In this article, we describe our platform, called TRANSAX, which enables participants to trade in an energy futures market, which improves efficiency by finding feasible matches for energy trades, enabling DSOs to plan their energy needs better. TRANSAX provides privacy to participants by anonymizing their trading activity using a distributed mixing service, while also enforcing constraints that limit trading activity based on safety requirements, such as keeping planned energy flow below line capacity. We show that TRANSAX can satisfy the seemingly conflicting requirements of efficiency, safety, and privacy. We also provide an analysis of how much trading efficiency is lost. Trading efficiency is improved through the problem formulation, which accounts for temporal flexibility, and system efficiency is improved using a hybrid-solver architecture. Lastly, we describe a testbed to run experiments and demonstrate its performance using simulation results.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Tomopy: A Python toolbox to perform X-Ray data proessing and image reconstruction.

Tomopy is a Python toolbox to perform x-ray data processing, image reconstruction and data exchange tasks at synchrotron facilities. The dependencies of the software are currently as follows: -Python related python standard library (http://docs.python.org/2/library/) numpy (http://www.numpy.org/) scipy (http://scipy.org/) matplotlib (http://matplotlip.org/) sphinx (http://sphinx-doc.org) pil (http://www.pythonware.com/products/pil/) pyhdf (http://pysclint.sourceforge.net/pyhdf/) h5py (http://www.h5py.org) pywt (http://www.pybytes.com/pywavelets/) file.py (https://pyspec.svn.sourceforge.net/svnroot/pyspec/trunk/pyspec/ccd/files.py) -C/C++ related: gridec (anonymous?? C-code written back in 1997 that uses standard C library) fftw (http://www.fftw.org/) tomoRecon (multi-threaded C++ verion of gridrec. Author: Mark Rivers from APS. http://cars9.uchicago.edu/software/epics/tomoRecon.html) epics (http://www.aps.anl.gov/epics/)

Source record↗

Concurrent Relaxation through Accelerated Deep Learning

CRADL captures performance metrics of machine learning algorithms operating on mesh data from multiphysics codes This proxy application is a tool to explore scalability of inference on HPC platforms, and also gather performance metrics for inference on new machine learning specific hardware. CRADL is designed to give users as fine a control as possible over an inference simulation. Users may select the number of cycles, amount of data, and batch size to pass to the accelerator of choice. Additionally the user may select a number of performance optimization libraries and flags. CRADL comes packaged with a repository of anonymized multi-physics simulation data, as well as a pretrained model for inference. The code allows a user to load their own pre-trained model and data if they wish. The code can operate in multiple parallelization schemes, with performance enhancing options such as half-precision libraries, PyTorch benchmarking, and pinned memory with non-blocking data transfers.

Zieb, KristoferJ.↗