Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Analytics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Predicting diagnostic error in radiology via eye-tracking and image analytics: Preliminary investigation in mammography

Purpose: The primary aim of the present study was to test the feasibility of predicting diagnostic errors in mammography by merging radiologists’ gaze behavior and image characteristics. A secondary aim was to investigate group-based and personalized predictive models for radiologists of variable experience levels.Methods: The study was performed for the clinical task of assessing the likelihood of malignancy of mammographic masses. Eye-tracking data and diagnostic decisions for 40 cases were acquired from four Radiology residents and two breast imaging experts as part of an IRB-approved pilot study. Gaze behavior features were extracted from the eye-tracking data. Computer-generated and BIRADS images features were extracted from the images. Finally, machine learning algorithms were used to merge gaze and image features for predicting human error. Feature selection was thoroughly explored to determine the relative contribution of the various features. Group-based and personalized user modeling was also investigated.Results: Machine learning can be used to predict diagnostic error by merging gaze behavior characteristics from the radiologist and textural characteristics from the image under review. Leveraging data collected from multiple readers produced a reasonable group model [area under the ROC curve (AUC) = 0.792 ± 0.030]. Personalized user modeling was far more accurate for the more experienced readers (AUC = 0.837 ± 0.029) than for the less experienced ones (AUC = 0.667 ± 0.099). The best performing group-based and personalized predictive models involved combinations of both gaze and image features.Conclusions: Diagnostic errors in mammography can be predicted to a good extent by leveraging the radiologists’ gaze behavior and image content.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospects for in vivo estimation of photon linear attenuation coefficients using postprocessing dual-energy CT imaging on a commercial scanner: Comparison of analytic and polyenergetic statistical reconstruction algorithms

Purpose: Accurate patient-specific photon cross-section information is needed to support more accurate model-based dose calculation for low energy photon-emitting modalities in medicine such as brachytherapy and kilovoltage x-ray imaging procedures. A postprocessing dual-energy CT (pDECT) technique for noninvasivein vivo estimation of photon linear attenuation coefficients has been experimentally implemented on a commercial CT scanner and its accuracy assessed in idealized phantom geometries. Methods: Eight test materials of known composition and density were used to compare pDECT-estimated linear attenuation coefficients to NIST reference values over an energy range from 10 keV to 1 MeV. As statistical image reconstruction (SIR) has been shown to reconstruct images with less random and systematic error than conventional filtered backprojection (FBP), the pDECT technique was implemented with both an in-house polyenergetic SIR algorithm, alternating minimization (AM), as well as a conventional FBP reconstruction algorithm. Improvement from increased spectral separation was also investigated by filtering the high-energy beam with an additional 0.5 mm of tin. The law of propagated uncertainty was employed to assess the sensitivity of the pDECT process to errors in reconstructed images. Results: Mean pDECT-estimated linear attenuation coefficients for the eight test materials agreed within 1% of NIST reference values for energies from 1 MeV down to 30 keV, with mean errors rising to between 3% and 6% at 10 keV, indicating that the method is unbiased when measurement and calibration phantom geometries are matched. Reconstruction with FBP and AM algorithms conferred similar mean pDECT accuracy. However, single-voxel pDECT estimates reconstructed on a 1 × 1 × 3 mm{sup 3} grid are shown to be highly sensitive to reconstructed image uncertainty; in some cases pDECT attenuation coefficient estimates exhibited standard deviations on the order of 20% around the mean. Reconstruction with the statistical AM algorithm led to standard deviations roughly 40% to 60% less than FBP reconstruction. Additional tin filtration of the high energy beam exhibits similar pDECT estimation accuracy as the unfiltered beam, even when scanning with only 25% of the dose. Using the law of propagated uncertainty, low Z materials are found to be more sensitive to image reconstruction errors than high Z materials. Furthermore, it is estimated that reconstructed CT image uncertainty must be limited to less than 0.25% to achieve a target linear-attenuation coefficient estimation uncertainty of 3% at 28 keV. Conclusions: That pDECT supports mean linear attenuation coefficient measurement accuracies of 1% of reference values for energies greater than 30 keV is encouraging. However, the sensitivity of the pDECT measurements to noise and systematic errors in reconstructed CT images warrants further investigation in more complex phantom geometries. The investigated statistical reconstruction algorithm, AM, reduced random measurement uncertainty relative to FBP owing to improved noise performance. These early results also support efforts to increase DE spectral separation, which can further reduce the pDECT sensitivity to measurement uncertainty.

61 RADIATION PROTECTION AND DOSIMETRY↗

User-Centered Evaluation of Visual Analytics

Visual analytics systems are becoming very popular. More domains now use interactive visualizations to analyze the ever-increasing amount and heterogeneity of data. More novel visualizations are being developed for more tasks and users. We need to ensure that these systems can be evaluated to determine that they are both useful and usable. A user-centered evaluation for visual analytics needs to be developed for these systems. While many of the typical human-computer interaction (HCI) evaluation methodologies can be applied as is, others will need modification. Additionally, new functionality in visual analytics systems needs new evaluation methodologies. There is a difference between usability evaluations and user-centered evaluations. Usability looks at the efficiency, effectiveness, and user satisfaction of users carrying out tasks with software applications. User-centered evaluation looks more specifically at the utility provided to the users by the software. This is reflected in the evaluations done and in the metrics used. In the visual analytics domain this is very challenging as users are most likely experts in a particular domain, the tasks they do are often not well defined, the software they use needs to support large amounts of different kinds of data, and often the tasks last for months. These difficulties are discussed more in the section on User-centered Evaluation. Our goal is to provide a discussion of user-centered evaluation practices for visual analytics, including existing practices that can be carried out and new methodologies and metrics that need to be developed and agreed upon by the visual analytics community. The material provided here should be of use for both researchers and practitioners in the field of visual analytics. Researchers and practitioners in HCI and interested in visual analytics will find this information useful as well as a discussion on changes that need to be made to current HCI practices to make them more suitable to visual analytics. A history of analysis and analysis techniques and problems is provided as well as an introduction to user-centered evaluation and various evaluation techniques for readers from different disciplines. The understanding of these techniques is imperative if we wish to support analysis in the visual analytics software we develop. Currently the evaluations that are conducted and published for visual analytics software are very informal and consist mainly of comments from users or potential users. Our goal is to help researchers in visual analytics to conduct more formal user-centered evaluations. While these are time-consuming and expensive to carryout, the outcomes of these studies will have a defining impact on the field of visual analytics and help point the direction for future features and visualizations to incorporate. While many researchers view work in user-centered evaluation as a less-than-exciting area to work, the opposite is true. First of all, the goal is user-centered evaluation is to help visual analytics software developers, researchers, and designers improve their solutions and discover creative ways to better accommodate their users. Working with the users is extremely rewarding as well. While we use the term “users” in almost all situations there are a wide variety of users that all need to be accommodated. Moreover, the domains that use visual analytics are varied and expanding. Just understanding the complexities of a number of these domains is exciting. Researchers are trying out different visualizations and interactions as well. And of course, the size and variety of data are expanding rapidly. User-centered evaluation in this context is rapidly changing. There are no standard processes and metrics and thus those of us working on user-centered evaluation must be creative in our work with both the users and with the researchers and developers.

intelligence analysis↗

Validation of an Analytical Model for Therapeutic and Stray Dose Calculations of 6 MV Photon Beams

Cancer is one of the most significant health care problems today. It is estimated that 1 in 2 men and women will be diagnosed with some form of cancer in their lifetime. Nearly two thirds of cancer patients will receive radiation therapy at some point in their care and the vast majority of these radiotherapy treatments will be performed with megavoltage photon therapy. Photon treatment techniques typically devote considerable attention to limiting the exposure of healthy tissues outside of the intended treatment volume. Nonetheless, small levels of unwanted stray radiation are incident upon the patient's whole body, which can increase the risk for numerous late effects, including second malignancies. When one considers that second cancers account for approximately 15% of all cancers and that it is projected that by the year 2020, there will be almost 20 million cancer survivors in the United States and four million in the UK, the need for improved accuracy in stray dose calculations appears likely to increase dramatically. Despite the obvious benefits this capability would afford, contemporary commercial treatment planning systems (TPSs) lack the ability to accurately predict stray dose outside the treatment field, e.g., beyond the 5% isodose surface. Thus, there is a large, variable, and systematic underestimation of stray radiation exposures by commonly used clinical TPSs for photon therapy. To overcome this problem, in a companion paper we proposed a simple, physics-based analytical model that calculates the total therapeutic and stray dose from photon treatment fields. The purpose of this work was to evaluate the accuracy of the basic physics in the analytical absorbed dose model for several simple treatment fields. We assessed the performance of the basic physics in an analytical model that calculates the total absorbed dose deposited by primary, leakage, and scattered photons both inside and outside of square treatment fields of 6 MV photon conventional radiotherapy. The assessment was accomplished by comparing model predictions of total dose with measured dose profiles in a water-phantom. The major finding of this study is that the physics-based model performed well, predicting dose in water within 11.5% dose difference or 5 mm distance to agreement with measured values in the therapeutic region and within 1.1 mGy/Gy or 0.5 mm distance to agreement with measured values in the out-of-field region at 90% of the locations considered. Contemporary external-beam photon TPSs do not include the capability to accurately predict the absorbed dose beyond a few centimeters outside of the treatment field. Our work suggests that it is feasible to improve dosimetric accuracy in the out-of-field region using a simple and computationally fast, physics-based analytical algorithm. This is demonstrated by the measured absorbed dose as well as the corresponding values calculated by two contemporary commercial TPSs (Pinnacle, Philips Health care, Andover, MA and Eclipse, Varian Medical Systems, Inc., Palo Alto, CA) and the analytical model considered in this work. It is apparent that both TPSs underestimated the absorbed dose by greater than 3 mGy/Gy at locations outside of the 0.5% relative dose level. In contrast, the analytical model evaluated in this work calculated absorbed dose in the same region within 0.4 mGy/Gy of measured values. The physics-based analytical dose model could prove useful in a number of different applications. The accurate knowledge of absorbed dose deposited outside of the treatment field is especially important for predicting radiation late effects, such as second cancer, fertility complications, and cardiac toxicity. It may also facilitate predictions of the effects of in utero exposure. We conclude that it is possible to accurately calculate the therapeutic and stray absorbed dose from a conventional radiotherapy treatment field of 6 MV photons using a physics-based analytical model. This was demonstrated by the agreement between measured and calculated doses in water within 11.5% relative dose difference or 5 mm distance to agreement in the therapeutic region, and within 1.1 mGy/Gy absolute dose difference or 0.5 mm distance to agreement in the out-of-field region at 90% of positions for all of the fields considered in this work. This is also illustrated by Figure 4 which plots dose values from analytical model predictions and measurements at five representative irradiation conditions and shows that the analytical model agreement is good in all cases. Furthermore, the model validated in this work evidently can predict dose values with better accuracy at out-of-field locations than contemporary TPSs. This and previous works, taken together, suggest that analytical physics-based models will offer advantages over TPSs or Monte Carlo models for whole-body dose calculations for several radiotherapy applications.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-517: Analytic Formalism to Compute in Real Time Dose Distributions Delivered by HDR Units

Purpose: Develop an analytical algorithm to compute the dose delivered by Ir-192 dwell positions with high accuracy using the 3-dimensional (3D) dose distribution of an HDR source. Using our analytical function, the dose delivered by an HDR unit as treatment progresses can be determined using the actual delivered temporal and positional data of each individual dwell. Consequently, true delivered dose can be computed when each catheter becomes active. We hypothesize that the knowledge of such analytical formulation will allow developing HDR systems with a real time treatment evaluation tool to avoid mistreatments. Methods: In our analytic formulation, the dose is computed by using the full anisotropic function data of the TG 43 formalism with 3D ellipsoidal function. The discrepancy between the planned dose and the delivered dose is computed using an analytic perturbation method over the initial dose distribution. This methodology speeds up the computation because only changes in dose discrepancies originated by spatial and temporal deviations are computed. A dose difference map at the point of interest is obtained from these functions and this difference can be shown during treatment in real time to examine the treatment accuracy. Results: We determine the analytical solution and a perturbation function for the 3 translational 3 rotational, and 1D temporal errors in source distributions. The analytic formulation is a sequence of simple equations that can be processed in any modern computer in few seconds. Because computations are based in an analytical solution, small deviations of the dose when sub-millimeter positional changes occur can be detected. Conclusions: We formulated an analytical method to compute 4D dose distributions and dose differences based on an analytical solution and perturbations to the original dose. This method is highly accurate and can be.

60 APPLIED LIFE SCIENCES↗

A Visual Analytics Approach to Structured Data Analysis to Enhance Nonproliferation and Arms Control Verification Activities

Analysis activities for Nonproliferation and Arms Control verification require the use of many types of data. Tabular structured data, such as Excel spreadsheets and relational databases, have traditionally been used for data mining activities, where specific queries are issued against data to look for matching results. The application of visual analytics tools to structured data enables further exploration of datasets to promote discovery of previously unknown results. This paper discusses the application of a specific visual analytics tool to datasets related to the field of Arms Control and Nonproliferation to promote the use of visual analytics more broadly in this domain. Visual analytics focuses on analytical reasoning facilitated by interactive visual interfaces (Wong and Thomas 2004). It promotes exploratory analysis of data, and complements data mining technologies where known patterns can be mined for. Also with a human in the loop, they can bring in domain knowledge and subject matter expertise. Visual analytics has not widely been applied to this domain. In this paper, we will focus on one type of data: structured data, and show the results of applying a specific visual analytics tool to answer questions in the Arms Control and Nonproliferation domain. We chose to use the T.Rex tool, a visual analytics tool developed at PNNL, which uses a variety of visual exploration patterns to discover relationships in structured datasets, including a facet view, graph view, matrix view, and timeline view. The facet view enables discovery of relationships between categorical information, such as countries and locations. The graph tool visualizes node-link relationship patterns, such as the flow of materials being shipped between parties. The matrix visualization shows highly correlated categories of information. The timeline view shows temporal patterns in data. In this paper, we will use T.Rex with two different datasets to demonstrate how interactive exploration of the data can aid an analyst with arms control and nonproliferation verification activities. Using a dataset from PIERS (PIERS 2014), we will show how container shipment imports and exports can aid an analyst in understanding the shipping patterns between two countries. We will also use T.Rex to examine a collection of research publications from the IAEA International Nuclear Information System (IAEA 2014) to discover collaborations of concern. We hope this paper will encourage the use of visual analytics structured data analytics in the field of nonproliferation and arms control verification. Our paper outlines some of the challenges that exist before broad adoption of these kinds of tools can occur and offers next steps to overcome these challenges.

arms control↗

Homogenized blocked arcs for multicriteria optimization of radiotherapy: Analytical and numerical solutions

Purpose: Homogenized blocked arcs are intuitively appealing as basis functions for multicriteria optimization of rotational radiotherapy. Such arcs avoid an organ-at-risk (OAR), spread dose out well over the rest-of-body (ROB), and deliver homogeneous doses to a planning target volume (PTV) using intensity modulated fluence profiles, obtainable either from closed-form solutions or iterative numerical calculations. Here, the analytic and iterative arcs are compared. Methods: Dose-distributions have been calculated for nondivergent beams, both including and excluding scatter, beam penumbra, and attenuation effects, which are left out of the derivation of the analytic arcs. The most straightforward analytic arc is created by truncating the well-known Brahme, Roos, and Lax (BRL) solution, cutting its uniform dose region down from an annulus to a smaller nonconcave region lying beyond the OAR. However, the truncation leaves behind high dose hot-spots immediately on either side of the OAR, generated by very high BRL fluence levels just beyond the OAR. These hot-spots can be eliminated using alternative analytical solutions ''C'' and ''L,'' which, respectively, deliver constant and linearly rising fluences in the gap region between the OAR and PTV (before truncation). Results: Measured in terms of PTV dose homogeneity, ROB dose-spread, and OAR avoidance, C solutions generate better arc dose-distributions than L when scatter, penumbra, and attenuation are left out of the dose modeling. Including these factors, L becomes the best analytical solution. However, the iterative approach generates better dose-distributions than any of the analytical solutions because it can account and compensate for penumbra and scatter effects. Using the analytical solutions as starting points for the iterative methodology, dose-distributions almost as good as those obtained using the conventional iterative approach can be calculated very rapidly. Conclusions: The iterative methodology is appropriate and useful for computing homogenized blocked arcs, as it produces better dose-distributions than the analytic approaches and their obvious extensions, and can more straightforwardly be used to generate homogenized arcs for concave OARs. However, the analytical solutions provide promising starting points for the iterative algorithm, leading to fast convergence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization techniques for TRU waste from the Analytical Laboratory Hot Cells at Idaho National Laboratory

Characterization techniques for TRU waste from the Analytical Laboratory Hot Cells at Idaho National Laboratory Since the first reactor went hot in 1942, there has been a never ending desire to improve the nuclear reactor and the fuel that it burns. The Idaho National Laboratory has been a key player in reactor and fuel development. As more research projects begin, the spectrum of waste parameters grows. Over the years, the Analytical Laboratory (AL) at the Materials and Fuels Complex (MFC) at Idaho National Laboratory (INL) has supported a large range of various research projects. Each project brings its own challenge and analytical technique that, in turn, yields its own unique waste parameters. The AL Hot Cells at INL consist of 6 small cells that can support around 12 different fuel research projects at a time along with infrastructure and environmental samples. Each different project yields different levels of transuranic (TRU) material, RCRA constituents, dose, and contamination levels. The waste parameters from each project dictate a path forward for the waste Low-Level Waste (LLW), Contact Handled TRU (CH-TRU), Mixed Contact Handled TRU (M-CH-TRU), Remote Handled TRU (RH-TRU), or Mixed Remote Handled TRU (M-RH-TRU). With visual examination techniques and process knowledge as an aid, there have been waste handling methods developed that allow debris and sample material to be segregated. Unique characterization mechanisms have been applied for each debris and sample material that are generally more accurate than smear and surface contamination data. For debris found in the Hot Cells, analytical data is gathered and conservatively summarized for each fuel type and research method. This consists of data from Quadrupole Inductively Coupled Plasma Mass Spectrometry (Q-ICP-MS), Gamma Spectroscopy, and some data verification through Thermal Ionization Mass Spectrometry (TIMS) and Multi-Collector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS). This data gives a range of TRU isotope concentrations. Fuel age is taken into account to determine the dominant TRU activity isotopes. Cesium concentrations are also gathered. Each parameter/fuel type then ties a measured Cesium number to TRU content based on historical analytical data. Debris in the hot cells is segregated by project and packaged in individual 2 gallon metal paint cans. Each can is counted by gamma spectroscopy in a calculated and measured geometry. Using process knowledge to determine the fuel or project type, newly counted cesium numbers can be applied to the historic analytical data and TRU content can be estimated. The TRU content allows waste debris to be segregated between CH-TRU and RH-TRU. Packaging techniques can allow for the minimization if RH-TRU waste. Sample material received into the AL must be dissolved into a liquid matrix in order to be analyzed in most cases. When analysis is complete, these liquids go through a consolidation, complexation, neutralization, and solidification process where real time analytical data can be used to calculate TRU content and RCRA constitutes. These calculations allow for no further analytical data to be gathered. The waste matrix is considered stable and acceptable by all AK [define AK] documents. The unique techniques used in characterizing and handling the Analytical Laboratories Hot Cell waste can be applied to various situations and various laboratories. They allow for more accurate data for waste constituents and also for the minimization of RH-TRU waste.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗